add support for Mijia LYWSD03MMC
This commit is contained in:
parent
7c2327104d
commit
739ff29cbc
@ -186,6 +186,14 @@ my %XiaomiModels = (
|
||||
'firmware' => '0x2a',
|
||||
'devicename' => '0x3'
|
||||
},
|
||||
mijiaLYWSD03MMC => {
|
||||
'wdata' => '0x38',
|
||||
'wdataValue' => '0100',
|
||||
'wdatalisten' => 3,
|
||||
'battery' => '0x1b',
|
||||
'firmware' => '0x12',
|
||||
'devicename' => '0x3'
|
||||
},
|
||||
);
|
||||
|
||||
my %CallBatteryAge = (
|
||||
@ -222,7 +230,7 @@ sub Initialize {
|
||||
. 'maxLux '
|
||||
. 'sshHost '
|
||||
. 'psCommand '
|
||||
. 'model:flowerSens,thermoHygroSens,clearGrassSens '
|
||||
. 'model:flowerSens,thermoHygroSens,clearGrassSens,mijiaLYWSD03MMC '
|
||||
. 'blockingCallLoglevel:2,3,4,5 '
|
||||
. $readingFnAttributes;
|
||||
$hash->{parseParams} = 1;
|
||||
@ -413,7 +421,10 @@ sub Notify {
|
||||
CreateParamGatttool( $hash, 'read',
|
||||
$XiaomiModels{ AttrVal( $name, 'model', '' ) }{devicename} )
|
||||
if (
|
||||
AttrVal( $name, 'model', 'thermoHygroSens' ) eq 'thermoHygroSens'
|
||||
(
|
||||
AttrVal( $name, 'model', 'thermoHygroSens' ) eq 'thermoHygroSens'
|
||||
|| AttrVal( $name, 'model', 'mijiaLYWSD03MMC' ) eq 'mijiaLYWSD03MMC'
|
||||
)
|
||||
&& $devname eq $name
|
||||
&& grep /^$name.firmware.+/,
|
||||
@{$events}
|
||||
@ -506,10 +517,11 @@ sub stateRequestTimer {
|
||||
}
|
||||
|
||||
sub Set($$@) {
|
||||
my $hash = shift;
|
||||
my $arg_ref = shift;
|
||||
my $name = shift @$arg_ref;
|
||||
my $cmd = shift @$arg_ref // return qq{"set $name" needs at least one argument};
|
||||
my $hash = shift;
|
||||
my $arg_ref = shift;
|
||||
my $name = shift @$arg_ref;
|
||||
my $cmd = shift @$arg_ref
|
||||
// return qq{"set $name" needs at least one argument};
|
||||
|
||||
my $mod;
|
||||
my $handle;
|
||||
@ -536,8 +548,14 @@ sub Set($$@) {
|
||||
if ( AttrVal( $name, 'model', 'none' ) ne 'none' );
|
||||
$list .= ' devicename'
|
||||
if (
|
||||
AttrVal( $name, 'model', 'thermoHygroSens' ) eq 'thermoHygroSens'
|
||||
&& AttrVal( $name, 'model', 'none' ) ne 'none' );
|
||||
(
|
||||
AttrVal( $name, 'model', 'thermoHygroSens' ) eq
|
||||
'thermoHygroSens'
|
||||
|| AttrVal( $name, 'model', 'mijiaLYWSD03MMC' ) eq
|
||||
'mijiaLYWSD03MMC'
|
||||
)
|
||||
&& AttrVal( $name, 'model', 'none' ) ne 'none'
|
||||
);
|
||||
|
||||
return "Unknown argument $cmd, choose one of $list";
|
||||
}
|
||||
@ -548,10 +566,11 @@ sub Set($$@) {
|
||||
}
|
||||
|
||||
sub Get {
|
||||
my $hash = shift;
|
||||
my $arg_ref = shift;
|
||||
my $name = shift @$arg_ref;
|
||||
my $cmd = shift @$arg_ref // return qq{"set $name" needs at least one argument};
|
||||
my $hash = shift;
|
||||
my $arg_ref = shift;
|
||||
my $name = shift @$arg_ref;
|
||||
my $cmd = shift @$arg_ref
|
||||
// return qq{"set $name" needs at least one argument};
|
||||
|
||||
my $mod = 'read';
|
||||
my $handle;
|
||||
@ -582,8 +601,14 @@ sub Get {
|
||||
if ( AttrVal( $name, 'model', 'none' ) ne 'none' );
|
||||
$list .= ' devicename:noArg'
|
||||
if (
|
||||
AttrVal( $name, 'model', 'thermoHygroSens' ) eq 'thermoHygroSens'
|
||||
&& AttrVal( $name, 'model', 'none' ) ne 'none' );
|
||||
(
|
||||
AttrVal( $name, 'model', 'thermoHygroSens' ) eq
|
||||
'thermoHygroSens'
|
||||
|| AttrVal( $name, 'model', 'mijiaLYWSD03MMC' ) eq
|
||||
'mijiaLYWSD03MMC'
|
||||
)
|
||||
&& AttrVal( $name, 'model', 'none' ) ne 'none'
|
||||
);
|
||||
return "Unknown argument $cmd, choose one of $list";
|
||||
}
|
||||
|
||||
@ -684,7 +709,7 @@ sub ExecGatttool_Run {
|
||||
|
||||
$cmd =
|
||||
"ssh $sshHost 'gatttool -i $hci -b $mac --char-write-req -a 0x33 -n A01F && gatttool -i $hci -b $mac --char-read -a 0x35 2>&1 '"
|
||||
if ( $sshHost ne 'none'
|
||||
if ( $sshHost ne 'none'
|
||||
&& $gattCmd eq 'write'
|
||||
&& AttrVal( $name, 'model', 'none' ) eq 'flowerSens' );
|
||||
|
||||
@ -749,11 +774,11 @@ qx(ssh $sshHost '$psCommand | grep -E "$gatttoolCmdlineStaticEscaped"')
|
||||
. join( ",", @gtResult ) );
|
||||
|
||||
$handle = '0x35'
|
||||
if ( $sshHost ne 'none'
|
||||
if ( $sshHost ne 'none'
|
||||
&& $gattCmd eq 'write'
|
||||
&& AttrVal( $name, 'model', 'none' ) eq 'flowerSens' );
|
||||
$gattCmd = 'read'
|
||||
if ( $sshHost ne 'none'
|
||||
if ( $sshHost ne 'none'
|
||||
&& $gattCmd eq 'write'
|
||||
&& AttrVal( $name, 'model', 'none' ) eq 'flowerSens' );
|
||||
|
||||
@ -818,7 +843,7 @@ sub ExecGatttool_Done {
|
||||
);
|
||||
}
|
||||
|
||||
if ( $respstate eq 'ok'
|
||||
if ( $respstate eq 'ok'
|
||||
&& $gattCmd eq 'write'
|
||||
&& AttrVal( $name, 'model', 'none' ) eq 'flowerSens' )
|
||||
{
|
||||
@ -922,6 +947,42 @@ sub ProcessingNotification {
|
||||
$readings = ThermoHygroSensHandle0x3( $hash, $notification );
|
||||
}
|
||||
}
|
||||
elsif ( AttrVal( $name, 'model', 'none' ) eq 'mijiaLYWSD03MMC' ) {
|
||||
if ( $handle eq '0x1b' ) {
|
||||
### mijiaLYWSD03MMC - Read Battery Data
|
||||
Log3( $name, 4,
|
||||
"XiaomiBTLESens ($name) - ProcessingNotification: handle 0x1b"
|
||||
);
|
||||
|
||||
$readings = mijiaLYWSD03MMC_Handle0x1b( $hash, $notification );
|
||||
}
|
||||
elsif ( $handle eq '0x38' ) {
|
||||
### mijiaLYWSD03MMC - Read Sensor Data
|
||||
Log3( $name, 4,
|
||||
"XiaomiBTLESens ($name) - ProcessingNotification: handle 0x38"
|
||||
);
|
||||
|
||||
$readings = mijiaLYWSD03MMC_Handle0x38( $hash, $notification );
|
||||
}
|
||||
elsif ( $handle eq '0x12' ) {
|
||||
### mijiaLYWSD03MMC - Read Firmware Data
|
||||
Log3( $name, 4,
|
||||
"XiaomiBTLESens ($name) - ProcessingNotification: handle 0x12"
|
||||
);
|
||||
|
||||
$readings = mijiaLYWSD03MMC_Handle0x12( $hash, $notification );
|
||||
}
|
||||
elsif ( $handle eq '0x3' ) {
|
||||
### mijiaLYWSD03MMC - Read and Write Devicename
|
||||
Log3( $name, 4,
|
||||
"XiaomiBTLESens ($name) - ProcessingNotification: handle 0x3" );
|
||||
|
||||
return CreateParamGatttool( $hash, 'read',
|
||||
$XiaomiModels{ AttrVal( $name, 'model', '' ) }{devicename} )
|
||||
unless ( $gattCmd eq 'read' );
|
||||
$readings = mijiaLYWSD03MMC_Handle0x3( $hash, $notification );
|
||||
}
|
||||
}
|
||||
elsif ( AttrVal( $name, 'model', 'none' ) eq 'clearGrassSens' ) {
|
||||
if ( $handle eq '0x3b' ) {
|
||||
### Clear Grass Sens - Read Battery Data
|
||||
@ -1085,8 +1146,7 @@ sub ThermoHygroSensHandle0x10 {
|
||||
$notification,
|
||||
(
|
||||
(
|
||||
scalar(@numberOfHex) == 14
|
||||
|| ( scalar(@numberOfHex) == 13
|
||||
scalar(@numberOfHex) == 14 || ( scalar(@numberOfHex) == 13
|
||||
&& $readings{'temperature'} > 9 )
|
||||
) ? 18 : 16
|
||||
),
|
||||
@ -1137,6 +1197,85 @@ sub ThermoHygroSensHandle0x3 {
|
||||
return \%readings;
|
||||
}
|
||||
|
||||
sub mijiaLYWSD03MMC_Handle0x1b($$) {
|
||||
### mijiaLYWSD03MMC - Battery Data
|
||||
my ( $hash, $notification ) = @_;
|
||||
|
||||
my $name = $hash->{NAME};
|
||||
my %readings;
|
||||
|
||||
Log3( $name, 4, "XiaomiBTLESens ($name) - mijiaLYWSD03MMC Handle0x1b" );
|
||||
|
||||
chomp($notification);
|
||||
$notification =~ s/\s+//g;
|
||||
|
||||
### neue Vereinheitlichung für Batteriereadings Forum #800017
|
||||
$readings{'batteryPercent'} = $notification; ###hex( "0x" . $notification );
|
||||
$readings{'batteryState'} =
|
||||
( hex( "0x" . $notification ) > 15 ? "ok" : "low" );
|
||||
|
||||
$hash->{helper}{CallBattery} = 1;
|
||||
CallBattery_Timestamp($hash);
|
||||
return \%readings;
|
||||
}
|
||||
|
||||
sub mijiaLYWSD03MMC_Handle0x38($$) {
|
||||
### mijiaLYWSD03MMC - Read Sensor Data
|
||||
my ( $hash, $notification ) = @_;
|
||||
|
||||
my $name = $hash->{NAME};
|
||||
my %readings;
|
||||
|
||||
Log3( $name, 4, "XiaomiBTLESens ($name) - mijiaLYWSD03MMC Handle0x38" );
|
||||
|
||||
return stateRequest($hash)
|
||||
unless ( $notification =~ /^([0-9a-f]{2}(\s?))*$/ );
|
||||
|
||||
my @splitVal = split( ' ', $notification );
|
||||
|
||||
$notification =~ s/\s+//g;
|
||||
|
||||
$readings{'temperature'} = hex( "0x" . $splitVal[1] . $splitVal[0] ) / 100;
|
||||
$readings{'humidity'} = hex( "0x" . $splitVal[2] );
|
||||
|
||||
$hash->{helper}{CallBattery} = 0;
|
||||
return \%readings;
|
||||
}
|
||||
|
||||
sub mijiaLYWSD03MMC_Handle0x12($$) {
|
||||
### mijiaLYWSD03MMC - Read Firmware Data
|
||||
my ( $hash, $notification ) = @_;
|
||||
|
||||
my $name = $hash->{NAME};
|
||||
my %readings;
|
||||
|
||||
Log3( $name, 4, "XiaomiBTLESens ($name) - mijiaLYWSD03MMC Handle0x12" );
|
||||
|
||||
$notification =~ s/\s+//g;
|
||||
|
||||
$readings{'firmware'} = pack( 'H*', $notification );
|
||||
|
||||
$hash->{helper}{CallBattery} = 0;
|
||||
return \%readings;
|
||||
}
|
||||
|
||||
sub mijiaLYWSD03MMC_Handle0x3($$) {
|
||||
### mijiaLYWSD03MMC - Read and Write Devicename
|
||||
my ( $hash, $notification ) = @_;
|
||||
|
||||
my $name = $hash->{NAME};
|
||||
my %readings;
|
||||
|
||||
Log3( $name, 4, "XiaomiBTLESens ($name) - mijiaLYWSD03MMC Handle0x3" );
|
||||
|
||||
$notification =~ s/\s+//g;
|
||||
|
||||
$readings{'devicename'} = pack( 'H*', $notification );
|
||||
|
||||
$hash->{helper}{CallBattery} = 0;
|
||||
return \%readings;
|
||||
}
|
||||
|
||||
sub ClearGrassSensHandle0x3b {
|
||||
### Clear Grass Sens - Battery Data
|
||||
my $hash = shift;
|
||||
@ -1251,6 +1390,7 @@ sub WriteReadings {
|
||||
)
|
||||
)
|
||||
if ( AttrVal( $name, 'model', 'none' ) eq 'thermoHygroSens'
|
||||
|| AttrVal( $name, 'model', 'none' ) eq 'mijiaLYWSD03MMC'
|
||||
|| AttrVal( $name, 'model', 'none' ) eq 'clearGrassSens' );
|
||||
|
||||
readingsEndUpdate( $hash, 1 );
|
||||
@ -1606,7 +1746,7 @@ sub BTLE_CmdlinePreventGrepFalsePositive {
|
||||
],
|
||||
"release_status": "stable",
|
||||
"license": "GPL_2",
|
||||
"version": "v2.9.1",
|
||||
"version": "v3.0.0",
|
||||
"author": [
|
||||
"Marko Oldenburg <leongaultier@gmail.com>"
|
||||
],
|
||||
|
Loading…