fix winOpnSensitifity
This commit is contained in:
parent
7976891249
commit
ef45e0f9d5
@ -45,7 +45,7 @@ package main;
|
||||
use strict;
|
||||
use warnings;
|
||||
|
||||
my $version = "0.2.1";
|
||||
my $version = "0.2.2";
|
||||
|
||||
sub CometBlueBTLE_Initialize($) {
|
||||
|
||||
@ -120,6 +120,7 @@ my %gatttChar = (
|
||||
'devicename' => '0x3',
|
||||
'battery' => '0x41',
|
||||
'payload' => '0x3f',
|
||||
# 'payload2' => '0x3d',
|
||||
'firmware' => '0x18',
|
||||
'pin' => '0x47',
|
||||
'date' => '0x1d',
|
||||
@ -173,7 +174,7 @@ my %CallBatteryAge = (
|
||||
);
|
||||
|
||||
# declare prototype
|
||||
sub ExecGatttool_Run($);
|
||||
#sub ExecGatttool_Run($);
|
||||
|
||||
sub Define($$) {
|
||||
|
||||
@ -191,7 +192,7 @@ sub Define($$) {
|
||||
|
||||
$hash->{BTMAC} = $mac;
|
||||
$hash->{VERSION} = $version;
|
||||
$hash->{INTERVAL} = 150;
|
||||
$hash->{INTERVAL} = 300;
|
||||
$hash->{helper}{writePin} = 0;
|
||||
$hash->{helper}{CallBattery} = 0;
|
||||
$hash->{NOTIFYDEV} = "global,$name";
|
||||
@ -415,7 +416,7 @@ sub Set($$@) {
|
||||
if ( $cmd eq 'desired-temp' or $cmd eq 'controlManu' ) {
|
||||
return
|
||||
'CometBlueBTLE: desired-temp requires <temperature> in degrees celsius as additional parameter'
|
||||
if ( @args < 1 );
|
||||
if ( @args != 1 );
|
||||
|
||||
#return 'CometBlueBTLE: desired-temp supports temperatures from 6.0 - 28.0 degrees' if($args[0]<8.0 or $args[0]>28.0 or $args[0] ne 'on' or $args[0] ne 'off');
|
||||
|
||||
@ -426,7 +427,7 @@ sub Set($$@) {
|
||||
elsif ( $cmd eq 'tempEco' ) {
|
||||
return
|
||||
'CometBlueBTLE: tempEco requires <temperature> in degrees celsius as additional parameter'
|
||||
if ( @args < 1 );
|
||||
if ( @args != 1 );
|
||||
return
|
||||
'CometBlueBTLE: tempEco supports temperatures from 6.0 to 28.0 degrees'
|
||||
if ( $args[0] < 12.0 or $args[0] > 23.0 );
|
||||
@ -438,7 +439,7 @@ sub Set($$@) {
|
||||
elsif ( $cmd eq 'tempComfort' ) {
|
||||
return
|
||||
'CometBlueBTLE: tempComfort requires <temperature> in degrees celsius as additional parameter'
|
||||
if ( @args < 1 );
|
||||
if ( @args != 1 );
|
||||
return
|
||||
'CometBlueBTLE: tempComfort supports temperatures from 6.0 to 28.0 degrees'
|
||||
if ( $args[0] < 12.0 or $args[0] > 23.0 );
|
||||
@ -449,7 +450,7 @@ sub Set($$@) {
|
||||
}
|
||||
elsif ( $cmd eq 'tempOffset' ) {
|
||||
return 'CometBlueBTLE: tempOffset requires an additional parameter'
|
||||
if ( @args < 1 );
|
||||
if ( @args != 1 );
|
||||
return 'CometBlueBTLE: tempOffset supports values from -5.0 to 5.0'
|
||||
if ( $args[0] < -5.0 or $args[0] > 5.0 );
|
||||
|
||||
@ -460,10 +461,7 @@ sub Set($$@) {
|
||||
elsif ( $cmd eq 'winOpnSensitivity' ) {
|
||||
return
|
||||
'CometBlueBTLE: winOpnSensitivity requires an additional parameter high, medium or low'
|
||||
if ( @args < 1
|
||||
or $args[0] ne 'high'
|
||||
or $args[0] ne 'medium'
|
||||
or $args[0] ne 'low' );
|
||||
if ( @args != 1 );
|
||||
|
||||
$handle = $gatttChar{ AttrVal( $name, 'model', '' ) }{'payload'};
|
||||
$value = join( " ", @args );
|
||||
@ -472,7 +470,7 @@ sub Set($$@) {
|
||||
elsif ( $cmd eq 'winOpnPeriod' ) {
|
||||
return
|
||||
'CometBlueBTLE: winOpnSensitivity requires an additional parameter in minutes'
|
||||
if ( @args < 1 );
|
||||
if ( @args != 1 );
|
||||
|
||||
$handle = $gatttChar{ AttrVal( $name, 'model', '' ) }{'payload'};
|
||||
$value = join( " ", @args );
|
||||
@ -495,7 +493,7 @@ sub Set($$@) {
|
||||
$list .=
|
||||
" tempComfort:12.0,12.5,13.0,13.5,14.0,14.5,15.0,15.5,16.0,16.5,17.0,17.5,18.0,18.5,19.0,19.5,20.0,20.5,21.0,21.5,22.0,22.5,23.0";
|
||||
$list .=
|
||||
" tempOffset:-5,-4.5,-4,-3.5,-3,-2.5,-2,-1.5,-1,-0.5,0,0.5,1,1.5,2,2.5,3,3.5,4,4.5,5 winOpnSensitivity:high,medium,low winOpnPeriod:slider,5,5,30";
|
||||
" tempOffset:-5,-4.5,-4,-3.5,-3,-2.5,-2,-1.5,-1,-0.5,0,0.5,1,1.5,2,2.5,3,3.5,4,4.5,5 winOpnSensitivity:high,medium,low winOpnPeriod:slider,5,5,30 resetBatteryTimestamp:noArg";
|
||||
|
||||
return "Unknown argument $cmd, choose one of $list";
|
||||
}
|
||||
@ -524,6 +522,15 @@ sub Get($$@) {
|
||||
return StateRequest($hash);
|
||||
|
||||
}
|
||||
# elsif ( $cmd eq 'temperatures2' ) {
|
||||
# return 'usage: temperatures2' if ( @args != 0 );
|
||||
#
|
||||
# return 'another process is running, try again later'
|
||||
# if ( $hash->{helper}{writePin} == 1 );
|
||||
# return CreateParamGatttool( $hash, 'read',
|
||||
# $gatttChar{ AttrVal( $name, 'model', '' ) }{'payload2'} )
|
||||
#
|
||||
# }
|
||||
elsif ( $cmd eq 'firmware' ) {
|
||||
return 'usage: firmware' if ( @args != 0 );
|
||||
|
||||
@ -1376,24 +1383,96 @@ sub CmdlinePreventGrepFalsePositive($) {
|
||||
1;
|
||||
|
||||
=pod
|
||||
|
||||
=item device
|
||||
=item summary
|
||||
=item summary_DE
|
||||
=item summary
|
||||
=item summary_DE CometBlueBTLE ist ein Modul zum Steuern diverser BTLE Thermostate
|
||||
|
||||
=begin html
|
||||
|
||||
<a name=""></a>
|
||||
<h3></h3>
|
||||
|
||||
|
||||
=end html
|
||||
|
||||
=begin html_DE
|
||||
|
||||
<a name=""></a>
|
||||
<h3></h3>
|
||||
|
||||
<a name="CometBlueBTLE"></a>
|
||||
<h3>CometBlueBTLE - BTLE Thermostate</h3>
|
||||
<ul>
|
||||
Das Modul steuert diverse BTLE Thermostate. Unterstützt werden derzeit Xavax Hama,Sygonix HT100 BT,Comet Blue,SilverCrest und THERMy blue.
|
||||
<br><br>
|
||||
<a name="CometBlueBTLEdefine"></a>
|
||||
<b>Define</b>
|
||||
<ul><br>
|
||||
<code>define <name> CometBlueBTLE <BT-MAC></code>
|
||||
<br><br>
|
||||
Example:
|
||||
<ul><br>
|
||||
<code>define HeizungsThermostatKueche CometBlueBTLE C4:7C:8D:62:42:6F</code><br>
|
||||
</ul>
|
||||
<br>
|
||||
Der Befehl legt ein Device vom Typ CometBlueBTLE mit dem Namen HeizungsThermostatKueche und der Bluetooth MAC C4:7C:8D:62:42:6F an.<br />
|
||||
Nach dem Anlegen des Device und setzen des korrekten model Attributes werden umgehend und automatisch die aktuellen Daten vom betroffenen Thermostat gelesen.
|
||||
</ul>
|
||||
<br><br>
|
||||
<a name="CometBlueBTLEreadings"></a>
|
||||
<b>Readings</b>
|
||||
<ul>
|
||||
<li>0_tempListSat - Schaltzeiten für Samstag im automatik Betrieb, 8 Schaltzeiten je 4 für Start und Ende</li>
|
||||
<li>1_tempListSun - Schaltzeiten für Sonntag im automatik Betrieb, 8 Schaltzeiten je 4 für Start und Ende</li>
|
||||
<li>2_tempListMon - Schaltzeiten für Montag im automatik Betrieb, 8 Schaltzeiten je 4 für Start und Ende</li>
|
||||
<li>3_tempListTue - Schaltzeiten für Dienstag im automatik Betrieb, 8 Schaltzeiten je 4 für Start und Ende</li>
|
||||
<li>4_tempListWed - Schaltzeiten für Mittwoch im automatik Betrieb, 8 Schaltzeiten je 4 für Start und Ende</li>
|
||||
<li>5_tempListThu - Schaltzeiten für Donnerstag im automatik Betrieb, 8 Schaltzeiten je 4 für Start und Ende</li>
|
||||
<li>6_tempListFri - Schaltzeiten für Freitag im automatik Betrieb, 8 Schaltzeiten je 4 für Start und Ende</li>
|
||||
<li>batteryPercent - aktueller Ladewert der Batterie in Prozent</li>
|
||||
<li>batteryState - ok/low aktueller Status der Batterie, unter 16 Prozent low</li>
|
||||
<li>desired-temp - Wunschtemperatur welche erreicht werden soll</li>
|
||||
<li>devicename - Name des Thermostaten</li>
|
||||
<li>firmware - Firmwareversion</li>
|
||||
<li>lastChangeBy - wer hat den letzten Status geädert, FHEM oder das Thermostat (manuell am Thermostat)</li>
|
||||
<li>lastGattError - Fehlermeldung vom gatttool wenn ein Fehler auf trat</li>
|
||||
<li>measured-temp - am Thermostat gemessene Temperatur</li>
|
||||
<li>state - Status des Thermostat</li>
|
||||
<li>tempComfort - eingestellte Komforttemperatur (Tag)</li>
|
||||
<li>tempEco - eingestellt Spartemperatur (Nacht)</li>
|
||||
<li>tempOffset - Offset zur Temperaturmessung, gemessende Temperatur minus das Offset ergibt measured-temp</li>
|
||||
<li>winOpnPeriod - wie lange soll die desired-temp gesenkt werden wenn Fenster offen erkannt wurde</li>
|
||||
<li>winOpnSensitivity - wie sensibel soll Fenster offen erkannt werden</li>
|
||||
</ul>
|
||||
<br>
|
||||
<a name="CometBlueBTLEset"></a>
|
||||
<b>get</b>
|
||||
<ul>
|
||||
<li>desired-temp - setzen der Wunschtemperatur</li>
|
||||
<li>tempComfort - einstellen der Komforttemperatur (Tag)</li>
|
||||
<li>controlManu - einstellen der Temperatur im manuellen Modus</li>
|
||||
<li>tempEco - einstellen der Spartemperatur (Nacht)</li>
|
||||
<li>tempOffset - einstellen des Offset Wertes von der gemessenen Temperatur</li>
|
||||
<li>winOpnSensitivity - wie sennsibel soll der Fenster offen Status erkannt werden</li>
|
||||
<li>winOpnPeriod - wie lange soll der Fenster offen Status und somit die gesenkte Temperatur gelten</li>
|
||||
</ul>
|
||||
<br>
|
||||
<a name="CometBlueBTLEget"></a>
|
||||
<b>get</b>
|
||||
<ul>
|
||||
<li>devicename - Devicename lesen</li>
|
||||
<li>firmware - Firmware version lesen</li>
|
||||
<li>tempList - Temperaturlisten lesen</li>
|
||||
<li>temperatures - eingestellte desired-temp und measured-temp lesen</li>
|
||||
</ul>
|
||||
<br>
|
||||
<a name="CometBlueBTLEattribute"></a>
|
||||
<b>Attribute</b>
|
||||
<ul>
|
||||
<li>interval - ändert das Abrufinterval</li>
|
||||
<li>disable - deaktiviert das Device</li>
|
||||
<li>disabledForIntervals - deaktiviert das Device für den entsprechenden Zeitraum</li>
|
||||
<li>hciDevice - gibt das HCI Device an über das die BTLE Verbindung stattfinden soll</li>
|
||||
<li>batteryFirmwareAge - max alter für den Batteriestatus bevor wieder abgerufen werden soll</li>
|
||||
<li>sshHost - IP / FQDN zum SSH Zieldevice</li>
|
||||
<li>blockingCallLoglevel - loglevel für BlockingCall</li>
|
||||
<li>pin - PIN des Thermostats zum abrufen der Daten</li>
|
||||
<li>model - Thermostatmodel</li>
|
||||
</ul>
|
||||
</ul>
|
||||
|
||||
=end html_DE
|
||||
|
||||
=cut
|
||||
|