ModbusTrovis5576: Add new values for circular water pump

git-svn-id: https://svn.fhem.de/fhem/trunk@14589 2b470e98-0d58-463d-a4d8-8e2adae1ed80
This commit is contained in:
Reinerlein 2017-06-28 13:52:56 +00:00
parent de5e87d9fe
commit 865e45e379

View File

@ -26,6 +26,8 @@
#
##############################################################################
# Changelog
# 28.06.2017
# Zwei neue Register hinzugefügt: "Wasser_Zirkulationspumpe" und das entsprechende Ebenen-Bit "Wasser_Zirkulationspumpe_EBN" dazu.
# 14.03.2016
# Initial Release
#
@ -211,6 +213,18 @@ my %Trovis5576ParseInfo = (
poll => 1,
set => 1
},
'c60' => { reading => 'Wasser_Zirkulationspumpe',
name => 'BinärausgBA5',
map => '0:Aus, 1:An',
poll => 1,
set => 1
},
'c99' => { reading => 'Wasser_Zirkulationspumpe_EBN',
name => 'EBNBinärBA5',
map => '0:GLT, 1:Autark',
poll => 1,
set => 1
},
'c1837' => {reading => 'Wasser_ThermischeDesinfektion',
name => 'FB14ThermDes',
map => '0:Aus, 1:An',
@ -292,6 +306,8 @@ sub ModbusTrovis5576_Initialize($) {
1;
=pod
=item summary Module to work with Heatung Control System Samson Trovis 5576
=item summary_DE Modul für Heizungssteuerungen vom Typ Samson Trovis 5576.
=begin html
<a name="ModbusTrovis5576"></a>
@ -359,13 +375,15 @@ sub ModbusTrovis5576_Initialize($) {
<li><b>Wasser_Betriebsart_EBN</b>: The Ebenen-Bit according to the Operating Mode. Possible values are GLT or Autark.</li>
<li><b>Wasser_Speicherladepumpe</b>: The on/off state of the reservoir loading pump. Possible values are An or Aus.</li>
<li><b>Wasser_Speicherladepumpe_EBN</b>: The Ebenen-Bit according to the Speicherladepumpe. Possible values are GLT or Autark.</li>
<li><b>Wasser_Zirkulationspumpe</b>: The on/off state of the circular pump. Possible values are An or Aus.</li>
<li><b>Wasser_Zirkulationspumpe_EBN</b>: The Ebenen-Bit according to the circular pump. Possible values are GLT or Autark.</li>
<li><b>Wasser_ThermischeDesinfektion</b>: On/off state of the thermal disinfection. Possible values are An or Aus.</li>
<li><b>Wasser_Temp_Soll</b>: The desired temperature for the drinkabke water reservoir.</li>
<li><b>Wasser_Temp_Minimum</b>: The lowest temperature for the drinkabke water reservoir.</li>
<li><b>Wasser_Temp_Minimum</b>: The lowest temperature for the drinkable water reservoir.</li>
<li><b>Wasser_Temp_Desinfektion</b>: The desired temperature of the thermal disinfection system.</li>
</ul></li>
</ul><br />
All other Readings (along with there Meanings) which can only be read:<br />
All other Readings (along with their Meanings) which can only be read:<br />
<ul>
<li>Common Data:<ul>
<li><b>Modellnummer</b>: Shows the modelnumber. Should be "5576".</li>
@ -479,6 +497,8 @@ sub ModbusTrovis5576_Initialize($) {
<li><b>Wasser_Betriebsart_EBN</b>: Das Ebenen-Bit zur Betriebsart. Kann GLT oder Autark sein, und gibt an, ob die Heizungssteuerung Autark läuft, oder übersteuert wurde.</li>
<li><b>Wasser_Speicherladepumpe</b>: Der Zustand der Speicherladepumpe. Kann An oder Aus sein.</li>
<li><b>Wasser_Speicherladepumpe_EBN</b>: Das Ebenen-Bit zur Speicherladepumpe. Kann GLT oder Autark sein, und gibt an, ob die Pumpe Autark läuft, oder übersteuert wurde.</li>
<li><b>Wasser_Zirkulationspumpe</b>: Der Zustand der Zirkulationspumpe. Kann An oder Aus sein.</li>
<li><b>Wasser_Zirkulationspumpe_EBN</b>: Das Ebenen-Bit zur Zirkulationspumpe. Kann GLT oder Autark sein, und gibt an, ob die Pumpe Autark läuft, oder übersteuert wurde.</li>
<li><b>Wasser_ThermischeDesinfektion</b>: Gibt an, ob gerade eine thermische Desinfektion läuft (=An) oder nicht (=Aus). </li>
<li><b>Wasser_Temp_Soll</b>: Die Solltemperatur des Trinkwasserspeichers.</li>
<li><b>Wasser_Temp_Minimum</b>: Die Minimaltemperatur des Trinkwasserspeichers.</li>