diff --git a/CHANGED b/CHANGED index 80f8911..816fbc9 100644 --- a/CHANGED +++ b/CHANGED @@ -1 +1 @@ - [final] - removed debug print lines, cleanup code + [final 2] - removed debug dumper code diff --git a/FHEM/74_GardenaSmartDevice.pm b/FHEM/74_GardenaSmartDevice.pm index ab4b2bc..4e5f3b3 100644 --- a/FHEM/74_GardenaSmartDevice.pm +++ b/FHEM/74_GardenaSmartDevice.pm @@ -571,7 +571,7 @@ sub Set { if ( AttrVal( $name, 'model', 'unknown' ) eq 'electronic_pressure_pump' ); $list .= -'closeAllValves:noArg stopScheduleValve:select,'.ReadingsVal( $name, 'ic24-valves_connected', '1' ).' resumeScheduleValve:select,'.ReadingsVal( $name, 'ic24-valves_connected', '1' ) +'closeAllValves:noArg resetvalveerrors:noArg stopScheduleValve:select,'.ReadingsVal( $name, 'ic24-valves_connected', '1' ).' resumeScheduleValve:select,'.ReadingsVal( $name, 'ic24-valves_connected', '1' ) if ( AttrVal( $name, 'model', 'unknown' ) eq 'ic24' ); foreach my $valve (split(',', ReadingsVal( $name, 'ic24-valves_connected', '1'))) { @@ -1290,6 +1290,7 @@ sub ReadingLangGerman { 'n/a' => 'nicht verfügbar', 'pump_not_filled' => 'Pumpe nicht gefüllt', 'clean_fine_filter' => 'Filter reinigen', + 'concurrent_limit_reached' => 'Grenze gleichzeitig geöffneter Ventile erreicht', ); if ( @@ -1820,6 +1821,7 @@ sub SetPredefinedStartPoints {
  • manualDurationValve4 n - open valve 4 for n minutes
  • manualDurationValve5 n - open valve 5 for n minutes
  • manualDurationValve6 n - open valve 6 for n minutes
  • +
  • resetvalveerrors n - reset valve errormessage
  • resumeScheduleValve n - (re)start irrigation schedule for valve n
  • stopScheduleValve n m - stop irrigation schedule for valve n (Default: 2038-01-18T00:00:00.000Z, Gardena App reads it as "permanently")
  • @@ -2235,6 +2237,7 @@ sub SetPredefinedStartPoints {
  • manualDurationValve4 n - Ventil 4 für n Minuten öffnen
  • manualDurationValve5 n - Ventil 5 für n Minuten öffnen
  • manualDurationValve6 n - Ventil 6 für n Minuten öffnen
  • +
  • resetvalveerrors n - Ventilfehler zurücksetzen
  • resumeScheduleValve n - Zeitplan für Ventil n wieder aktivieren
  • stopScheduleValve n m - Zeitplan für Ventil n anhalten für m Stunden (Default: 2038-01-18T00:00:00.000Z, durch Gardena-App als "dauerhaft" interpretiert)
  • diff --git a/controls_GardenaSmartDevice.txt b/controls_GardenaSmartDevice.txt index 4fc77d0..2167974 100644 --- a/controls_GardenaSmartDevice.txt +++ b/controls_GardenaSmartDevice.txt @@ -1,2 +1,2 @@ UPD 2022-07-21_19:43:48 49634 FHEM/73_GardenaSmartBridge.pm -UPD 2022-08-09_15:03:22 107552 FHEM/74_GardenaSmartDevice.pm +UPD 2022-08-11_12:40:06 107803 FHEM/74_GardenaSmartDevice.pm