fix ASC_BlockingTime_beforNightClose wird bei Regen(-schutz) ignoriert
This commit is contained in:
@ -133,11 +133,13 @@ sub _RainProtected {
|
||||
|
||||
$FHEM::Automation::ShuttersControl::shutters->setLastDrive(
|
||||
'rain protected');
|
||||
$FHEM::Automation::ShuttersControl::shutters->setDriveCmd(
|
||||
$FHEM::Automation::ShuttersControl::ascDev
|
||||
->getRainSensorShuttersClosedPos);
|
||||
$FHEM::Automation::ShuttersControl::shutters
|
||||
->setRainProtectionStatus('protected');
|
||||
|
||||
$FHEM::Automation::ShuttersControl::shutters->setDriveCmd(
|
||||
$FHEM::Automation::ShuttersControl::ascDev
|
||||
->getRainSensorShuttersClosedPos);
|
||||
|
||||
$FHEM::Automation::ShuttersControl::shutters
|
||||
->setRainProtectionStatus('protected');
|
||||
}
|
||||
|
||||
sub _RainUnprotected {
|
||||
@ -168,10 +170,11 @@ sub _RainUnprotected {
|
||||
->getClosedPos
|
||||
)
|
||||
)
|
||||
);
|
||||
)
|
||||
if (IsAfterShuttersTimeBlocking($shuttersDev));
|
||||
|
||||
$FHEM::Automation::ShuttersControl::shutters
|
||||
->setRainProtectionStatus('unprotected');
|
||||
$FHEM::Automation::ShuttersControl::shutters
|
||||
->setRainProtectionStatus('unprotected');
|
||||
}
|
||||
|
||||
|
||||
|
Reference in New Issue
Block a user