# Vaillant_routines.pl ===> Insert into 99_myUtils.pm
|
|
#
|
|
# Collection of various routines for Vaillant heating systems
|
|
#
|
|
# KEEP THE NAME AND COPYRIGHT
|
|
#
|
|
# Prof. Dr. Peter A. Henning
|
|
#
|
|
# $Id: 99_myUtils.pm 2014-12 - pahenning $
|
|
#
|
|
########################################################################################
|
|
#
|
|
# This programm is free software; you can redistribute it and/or modify
|
|
# it under the terms of the GNU General Public License as published by
|
|
# the Free Software Foundation; either version 2 of the License, or
|
|
# (at your option) any later version.
|
|
#
|
|
# The GNU General Public License can be found at
|
|
# http://www.gnu.org/copyleft/gpl.html.
|
|
# A copy is found in the textfile GPL.txt and important notices to the license
|
|
# from the author is found in LICENSE.txt distributed with these scripts.
|
|
#
|
|
# This script is distributed in the hope that it will be useful,
|
|
# but WITHOUT ANY WARRANTY; without even the implied warranty of
|
|
# MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
|
|
# GNU General Public License for more details.
|
|
#
|
|
########################################################################################
|
|
|
|
###############################################################################
|
|
#
|
|
# Vaillant_HWC_mode_postproc
|
|
#
|
|
# postprocessing of
|
|
# "get HWC OperatingMode\n\000get HWC Param1"
|
|
# "read HWC Status2\n\000read SOL Status2"
|
|
#
|
|
###############################################################################
|
|
|
|
sub Vaillant_HWC_mode_postproc($$){
|
|
|
|
my ($name,$str)=@_;
|
|
my $hash = $defs{"$name"};
|
|
my (@values,$day,$night,$off,$min,$max,$mode,$zval);
|
|
|
|
if( $str =~ /.*;.*/){
|
|
# target;mode target;0;0;0;131;22;0;min;max;0
|
|
@values = split(/[; \n]/,$str);
|
|
$day = sprintf("%4.1f",$values[0]);
|
|
$mode = $values[1];
|
|
$night = sprintf("%4.1f",$values[6]);
|
|
$off = sprintf("%4.1f",$values[7]);
|
|
$min = sprintf("%4.1f",$values[9]);
|
|
$max = sprintf("%4.1f",$values[10]);
|
|
} else {
|
|
@values = split(' ',$str);
|
|
$day = sprintf("%4.1f",$values[0]);
|
|
$night = sprintf("%4.1f",$values[4]);
|
|
$off = sprintf("%4.1f",$values[5]);
|
|
$min = sprintf("%4.1f",$values[6]);
|
|
$max = sprintf("%4.1f",$values[7]);
|
|
if( $values[1]==0 ){
|
|
$mode="disabled"
|
|
}elsif( $values[1]==1 ){
|
|
$mode="on"
|
|
}elsif( $values[1]==2 ){
|
|
$mode="off"
|
|
}elsif( $values[1]==3 ){
|
|
$mode="auto"
|
|
}elsif( $values[1]==4 ){
|
|
$mode="eco"
|
|
}elsif( $values[1]==5 ){
|
|
$mode="low"
|
|
}
|
|
}
|
|
readingsBeginUpdate($hash);
|
|
readingsBulkUpdate($hash, "postproc", $str);
|
|
readingsBulkUpdate($hash, "mode", $mode);
|
|
readingsBulkUpdate($hash, "Storage.day", $day);
|
|
readingsBulkUpdate($hash, "Storage.min", $min);
|
|
readingsBulkUpdate($hash, "Storage.max", $max);
|
|
readingsEndUpdate($hash,1);
|
|
$mode;
|
|
}
|
|
|
|
###############################################################################
|
|
#
|
|
# Vaillant_HWC_state_postproc
|
|
#
|
|
# postprocessing of
|
|
# "get HWC Status2\n\000get SOL Status2"
|
|
# "read HWC Status2\n\000read SOL Status2"
|
|
#
|
|
###############################################################################
|
|
|
|
sub Vaillant_HWC_state_postproc($$){
|
|
|
|
my ($name,$str)=@_;
|
|
my $hash = $defs{"$name"};
|
|
my (@values,$rval,$tval,$bval,$pval,$xval,$zval,$sp2,$sp3);
|
|
|
|
if( $str =~ /.*;.*/){
|
|
# status;ladung;SP1;target SP1;SP2;SP3
|
|
@values = split(/[; \n]/,$str);
|
|
$rval = sprintf("%5.2f",$values[2]);
|
|
$tval = sprintf("%4.1f",$values[3]);
|
|
$bval = ($values[0] == 80) ? "ON (WW)" : "OFF";
|
|
$pval = ($values[1] == 1) ? "ON" : "OFF";
|
|
$xval = sprintf("%5.2f %5.2f %5.2f %d %d", $values[2],0.0,$values[3],$values[0],$values[1]);
|
|
$zval = sprintf("SP1.T %5.2f °C, %s", $values[2],$pval);
|
|
$sp2 = sprintf("%5.2f",$values[5]);
|
|
$sp3 = sprintf("%5.2f",$values[6]);
|
|
|
|
}else{
|
|
# SP1 target status ladung SP1 SP2 SP3
|
|
@values = split(' ',$str);
|
|
$rval = sprintf("%5.2f",$values[0]);
|
|
$tval = sprintf("%4.1f",$values[1]);
|
|
$bval = ($values[2] == 80) ? "ON (WW)" : "OFF";
|
|
$pval = ($values[3] == 1) ? "ON" : "OFF";
|
|
$xval = sprintf("%5.2f %5.2f %5.2f %d %d", $values[0],0.0,$values[1],$values[2],$values[3]);
|
|
$zval = sprintf("SP1.T %5.2f °C, %s", $values[0],$pval);
|
|
$sp2 = sprintf("%5.2f",$values[5]);
|
|
$sp3 = sprintf("%5.2f",$values[6]);
|
|
|
|
}
|
|
readingsBeginUpdate($hash);
|
|
readingsBulkUpdate($hash, "postproc", $str);
|
|
readingsBulkUpdate($hash, "Storage.SP1.T", $rval);
|
|
readingsBulkUpdate($hash, "Storage.SP2.T", $sp2);
|
|
readingsBulkUpdate($hash, "Storage.SP3.T", $sp3);
|
|
readingsBulkUpdate($hash, "Storage.target", $tval);
|
|
readingsBulkUpdate($hash, "Burner", $bval);
|
|
readingsBulkUpdate($hash, "Pump", $pval);
|
|
readingsBulkUpdate($hash, "reading", $xval);
|
|
readingsEndUpdate($hash,1);
|
|
$zval;
|
|
}
|
|
|
|
|
|
###############################################################################
|
|
#
|
|
# Vaillant_HWC_broadcast_postproc
|
|
#
|
|
# postprocessing of
|
|
# "get cyc broad StatusHWC\n"
|
|
# "read broad StatusHWC
|
|
#
|
|
###############################################################################
|
|
|
|
sub Vaillant_HWC_broadcast_postproc($$){
|
|
|
|
my ($name,$str)=@_;
|
|
my $hash = $defs{"$name"};
|
|
my (@values,$rval,$tval,$bval,$pval,$xval,$zval);
|
|
|
|
if( ($str eq "")||($str eq "no data stored") ){
|
|
$rval = "err";
|
|
$tval = "err";
|
|
$bval = "err";
|
|
$pval = "err";
|
|
$xval = "err";
|
|
$zval = "err";
|
|
} elsif( $str =~ /.*;.*/){
|
|
# status;ladung;SP1;target
|
|
@values = split(';',$str);
|
|
$rval = sprintf("%5.2f",$values[2]);
|
|
$tval = sprintf("%4.1f",$values[3]);
|
|
$bval = ($values[0] == 80) ? "ON (WW)" : "OFF";
|
|
$pval = ($values[1] == 1) ? "ON" : "OFF";
|
|
$xval = sprintf("%5.2f %5.2f %5.2f %d %d", $values[2],0.0,$values[3],$values[0],$values[1]);
|
|
$zval = sprintf("SP1.T %5.2f °C, %s", $values[2],$pval);
|
|
} else {
|
|
@values=split(' ',$str);
|
|
if( $values[1] < 15 ){
|
|
$rval = "err";
|
|
$tval = "err";
|
|
$bval = "err";
|
|
$pval = "err";
|
|
$xval = "err";
|
|
$zval = "err";
|
|
}else {
|
|
$rval = sprintf("%5.2f",$values[0]);
|
|
$tval = sprintf("%4.1f",$values[1]);
|
|
$bval = ($values[2] == 80) ? "ON (WW)" : "OFF";
|
|
$pval = ($values[3] == 1) ? "ON" : "OFF";
|
|
$xval = sprintf("%5.2f %5.2f %5.2f %d %d",$values[0],0.0,$values[1],$values[2],$values[3]);
|
|
$zval = sprintf("SP1.T %5.2f °C, %s",$values[0],$pval);
|
|
}
|
|
}
|
|
readingsBeginUpdate($hash);
|
|
readingsBulkUpdate($hash, "postproc", $str);
|
|
readingsBulkUpdate($hash, "Storage.SP1.T", $rval);
|
|
readingsBulkUpdate($hash, "Storage.target", $tval);
|
|
readingsBulkUpdate($hash, "Burner", $bval);
|
|
readingsBulkUpdate($hash, "Pump", $pval);
|
|
readingsBulkUpdate($hash, "reading", $xval);
|
|
readingsEndUpdate($hash,1);
|
|
$zval;
|
|
}
|
|
|
|
###############################################################################
|
|
#
|
|
# Vaillant_HC_mode_postproc
|
|
#
|
|
# postprocessing of
|
|
# "get HC OperatingMode\n\000get HC Param1\n\000get vrs620 NameHC"
|
|
# "read HC OperatingMode\n\000read HC Param1\n\000read vrs620 NameHC"
|
|
#
|
|
###############################################################################
|
|
|
|
sub Vaillant_HC_mode_postproc($$$){
|
|
|
|
my ($name,$str,$circuit)=@_;
|
|
my $hash = $defs{"$name"};
|
|
my (@values,$room,$night,$off,$add,$min,$max,$pre,$cname,$mode);
|
|
|
|
$circuit=""
|
|
if ( $circuit == 1);
|
|
|
|
if( $str =~ /.*;.*/){
|
|
# room;mode room;night;off;add;min;max;pre cname
|
|
@values = split(/[; \n]/,$str);
|
|
$room = sprintf("%4.1f",$values[0]);
|
|
$mode = $values[1];
|
|
$night = sprintf("%4.1f",$values[3]);
|
|
$off = sprintf("%4.1f",$values[4]);
|
|
$add = sprintf("%4.1f",$values[5]);
|
|
$min = sprintf("%4.1f",$values[6]);
|
|
$max = sprintf("%4.1f",$values[7]);
|
|
$pre = sprintf("%4.1f",$values[8]);
|
|
$cname = sprintf("%s",$values[9]);
|
|
} else {
|
|
@values = split(' ',$str);
|
|
$room = sprintf("%4.1f",$values[0]);
|
|
$night = sprintf("%4.1f",$values[4]);
|
|
$off = sprintf("%4.1f",$values[5]);
|
|
$add = sprintf("%4.1f",$values[6]);
|
|
$min = sprintf("%4.1f",$values[7]);
|
|
$max = sprintf("%4.1f",$values[8]);
|
|
$pre = sprintf("%4.1f",$values[9]);
|
|
$cname = sprintf("%s",$values[10]);
|
|
if( $values[1]==0 ){
|
|
$mode="disabled"
|
|
}elsif( $values[1]==1 ){
|
|
$mode="on"
|
|
}elsif( $values[1]==2 ){
|
|
$mode="off"
|
|
}elsif( $values[1]==3 ){
|
|
$mode="auto"
|
|
}elsif( $values[1]==4 ){
|
|
$mode="eco"
|
|
}elsif( $values[1]==5 ){
|
|
$mode="low"
|
|
}
|
|
}
|
|
readingsBeginUpdate($hash);
|
|
readingsBulkUpdate($hash, "postproc", $str);
|
|
readingsBulkUpdate($hash, "mode".$circuit, $mode);
|
|
readingsBulkUpdate($hash, "mode".$circuit.".off", $off);
|
|
readingsBulkUpdate($hash, "Room".$circuit.".T", $room);
|
|
readingsBulkUpdate($hash, "Room".$circuit.".night", $night);
|
|
readingsBulkUpdate($hash, "Room".$circuit.".add", $add);
|
|
readingsBulkUpdate($hash, "VL".$circuit.".T.min", $min);
|
|
readingsBulkUpdate($hash, "VL".$circuit.".T.max", $max);
|
|
readingsBulkUpdate($hash, "name".$circuit, $cname);
|
|
readingsEndUpdate($hash,1);
|
|
$mode;
|
|
}
|
|
|
|
###############################################################################
|
|
#
|
|
# Vaillant_HC_mode_postproc
|
|
#
|
|
# postprocessing of
|
|
# "read HC Status1\n\000read HC Status2a\n\000read broad StatusHC"
|
|
#
|
|
#
|
|
###############################################################################
|
|
|
|
sub Vaillant_HC_state_postproc($$){
|
|
|
|
my ($name,$str)=@_;
|
|
my $hash = $defs{"$name"};
|
|
my (@values,$vval,$rval,$bval,$pval, $qval,$xval,$zval);
|
|
|
|
if( ($str eq "")||($str eq "no data stored") ){
|
|
$vval = "err";
|
|
$rval = "err";
|
|
$bval = "err";
|
|
$pval = "err";
|
|
$qval = "err";
|
|
$xval = "err";
|
|
$zval = "err";
|
|
}elsif( $str =~ /.*;.*/){
|
|
#
|
|
@values = split(/[; \n]/,$str);
|
|
$vval = sprintf("%4.1f",$values[10]);
|
|
$rval = sprintf("%4.1f",$values[11]);
|
|
if( $values[14] == 0 ){
|
|
$pval = "OFF";
|
|
$qval = "0 0";
|
|
}elsif( $values[14] == 1 ){
|
|
$pval = "ON (HK)";
|
|
$qval = "80 0";
|
|
}elsif( $values[14] == 2 ){
|
|
$pval = "ON (WW)";
|
|
$qval = "0 80";
|
|
}else{
|
|
$pval = "unknown";
|
|
$qval = "err";
|
|
}
|
|
|
|
}else{
|
|
#
|
|
@values = split(' ',$str);
|
|
$vval = sprintf("%4.1f",$values[5]);
|
|
$rval = sprintf("%4.1f",$values[6]);
|
|
if( $values[2] == 0 ){
|
|
$pval = "OFF";
|
|
$qval = "0 0";
|
|
}elsif( $values[2] == 1 ){
|
|
$pval = "ON (HK)";
|
|
$qval = "80 0";
|
|
}elsif( $values[2] == 2 ){
|
|
$pval = "ON (WW)";
|
|
$qval = "0 80";
|
|
}else{
|
|
$pval = "unknown";
|
|
$qval = "err";
|
|
}
|
|
}
|
|
|
|
$bval = HzBedarf();
|
|
$xval = sprintf("%5.2f %5.2f %s %5.2f",$vval,$rval,$qval,$bval);
|
|
$zval = sprintf("VL.T %5.2f °C, RL.T %5.2f °C, %s",$vval,$rval,$pval);
|
|
|
|
if( ($vval < 5) ){
|
|
$vval = "err";
|
|
$rval = "err";
|
|
$bval = "err";
|
|
$pval = "err";
|
|
$qval = "err";
|
|
$xval = "";
|
|
$zval = "err";
|
|
}
|
|
|
|
readingsBeginUpdate($hash);
|
|
readingsBulkUpdate($hash, "postproc", $str);
|
|
readingsBulkUpdate($hash, "VL.T", $vval);
|
|
readingsBulkUpdate($hash, "RL.T", $rval);
|
|
readingsBulkUpdate($hash, "pump", $pval);
|
|
readingsBulkUpdate($hash, "pump.P", $qval);
|
|
readingsBulkUpdate($hash, "consumption", $bval);
|
|
readingsBulkUpdate($hash, "reading", $xval)
|
|
if( $xval ne "" );
|
|
readingsEndUpdate($hash,1);
|
|
$zval
|
|
}
|
|
|
|
###############################################################################
|
|
#
|
|
# Vaillant_SOL_mode_postproc
|
|
#
|
|
# postprocessing of
|
|
# "get HC OperatingMode\n\000get HC Param1\n\000get vrs620 NameHC"
|
|
# "read HC OperatingMode\n\000read HC Param1\n\000read vrs620 NameHC"
|
|
#
|
|
###############################################################################
|
|
|
|
sub Vaillant_SOL_state_postproc($$){
|
|
|
|
my ($name,$str)=@_;
|
|
my $hash = $defs{"$name"};
|
|
readingsBeginUpdate($hash);
|
|
readingsBulkUpdate($hash, "postproc", $str);
|
|
readingsEndUpdate($hash,1);
|
|
}
|
|
|
|
|
|
###############################################################################
|
|
#
|
|
# Vaillant_Timer
|
|
#
|
|
###############################################################################
|
|
|
|
sub Vaillant_Timer($)
|
|
{
|
|
my @values=split(/[; ]/,$_);
|
|
#-- suppress leading zero ?
|
|
for(my $i=0;$i<6;$i++){
|
|
$values[$i]=~s/^0//;
|
|
}
|
|
my $sval=sprintf("%s-%s",$values[0],$values[1]);
|
|
$sval .=sprintf(", %s-%s",$values[2],$values[3])
|
|
if($values[2] ne $values[3]);
|
|
$sval .=sprintf(", %s-%s",$values[4],$values[5])
|
|
if($values[4] ne $values[5]);
|
|
return $sval;
|
|
} |