# $Id$
|
|
# fhem Modul für Viessmann API. Based on investigation of "thetrueavatar"
|
|
# (https://github.com/thetrueavatar/Viessmann-Api)
|
|
#
|
|
# This file is part of fhem.
|
|
#
|
|
# Fhem is free software: you can redistribute it and/or modify
|
|
# it under the terms of the GNU General Public License as published by
|
|
# the Free Software Foundation, either version 2 of the License, or
|
|
# (at your option) any later version.
|
|
#
|
|
# Fhem is distributed in the hope that it will be useful,
|
|
# but WITHOUT ANY WARRANTY; without even the implied warranty of
|
|
# MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
|
|
# GNU General Public License for more details.
|
|
#
|
|
# You should have received a copy of the GNU General Public License
|
|
# along with fhem. If not, see <http://www.gnu.org/licenses/>.
|
|
#
|
|
##############################################################################
|
|
# Changelog:
|
|
#
|
|
# 2018-11-24 initial version
|
|
# 2018-12-11 non-blocking
|
|
# Reading "status" in "state" umbenannt
|
|
# 2018-12-23 Neue Werte in der API werden unter ihrem JSON Name als Reading eingetragen
|
|
# Neue Readings:
|
|
# heating.boiler.sensors.temperature.commonSupply.status error
|
|
# heating.boiler.temperature.value 48.1
|
|
# heating.burner.modulation.value 11
|
|
# heating.burner.statistics.hours 933.336666666667
|
|
# heating.burner.statistics.starts 2717
|
|
# heating.circuits.0.circulation.pump.status on
|
|
# heating.dhw.charging.active 0
|
|
# heating.dhw.pumps.circulation.schedule.active 1
|
|
# heating.dhw.pumps.circulation.schedule.entries sun mode:on end:22:30 start:04:30 position:0, fri end:22:30 mode:on position:0 start:04:30,
|
|
# mon mode:on end:22:30 start:04:30 position:0,
|
|
# wed start:04:30 position:0 end:22:30 mode:on, thu mode:on end:22:30 position:0 start:04:30, sat end:22:30 mode:on position:0 start:04:30,
|
|
# tue position:0 start:04:30 end:22:30 mode:on,
|
|
# heating.dhw.pumps.circulation.status on
|
|
# heating.dhw.pumps.primary.status off
|
|
# heating.dhw.sensors.temperature.outlet.status error
|
|
# heating.dhw.temperature.main.value 53
|
|
# 2018-12-30 initial offical release
|
|
# remove special characters from readings
|
|
# some internal improvements suggested by CoolTux
|
|
# 2019-01-01 "disabled" implemented
|
|
# "set update implemented
|
|
# renamed "WW-onTimeCharge_aktiv" into "WW-einmaliges_Aufladen_aktiv"
|
|
# Attribute vitoconnect_raw_readings:0,1 " and ."vitoconnect_actions_active:0,1 " implemented
|
|
# "set clearReadings" implemented
|
|
# 2019-01-05 Passwort wird im KeyValue gespeichert statt im Klartext
|
|
# Action "oneTimeCharge" implemented
|
|
# 2019-01-14 installation, code and gw in den Internals unsichtbar gemacht
|
|
# Reading "counter" entfernt (ist weiterhin in Internals sichtbar)
|
|
# Reading WW-einmaliges_Aufladen_active umbenannt in WW-einmaliges_Aufladen
|
|
# Befehle zum setzen von
|
|
# HK1-Betriebsart
|
|
# HK2-Betriebsart
|
|
# HK1-Solltemperatur_normal
|
|
# HK2-Solltemperatur_normal
|
|
# HK1-Solltemperatur_reduziert
|
|
# HK2-Solltemperatur_reduziert
|
|
# WW-einmaliges_Aufladen
|
|
# Bedienfehler (z.B. Ausführung einer Befehls für HK2, wenn die Hezung nur einen Heizkreis hat)
|
|
# führen zu einem "Bad Gateway" Fehlermeldung in Logfile
|
|
# Achtung: Keine Prüfung ob Befehle sinnvoll und oder erlaubt sind! Nutzung auf eigene Gefahr!
|
|
# 2019-01-15 Fehler bei der Befehlsausführung gefixt
|
|
# 2019-01-22 Klartext für Readings für HK3 und heating.dhw.charging.level.* hinzugefügt
|
|
# set's für HK2 implementiert
|
|
# set für Slope und Shift implementiert
|
|
# set WW-Haupttemperatur und WW-Solltemperatur implementiert
|
|
# set HK1-Solltemperatur_comfort_aktiv HK1-Solltemperatur_comfort implementiert
|
|
# set HK1-Solltemperatur_eco implementiert (set HK1-Solltemperatur_eco_aktiv scheint es nicht zu geben?!)
|
|
# vor einem set vitoconnect update den alten Timer löschen
|
|
# set vitoconnect logResponseOnce implementiert (eventuell werden zusätzliche perl Pakete benötigt?)
|
|
# 2019-01-26 Fehler, dass HK3 Readings auf HK2 gemappt wurden gefixt
|
|
# 2019-02-17 Readings für den Stromverbrauch (heating.power.consumption.*) und
|
|
# Raumtemperatur (heating.circuits.?.sensors.temperature.room.value) ergänzt
|
|
# set-Befehle für HKs werden nur noch angezeigt, wenn der HK auch aktiv ist
|
|
# Wiki aktualisiert
|
|
# 2019-02-27 stacktrace-Fehler (hoffentlich) behoben
|
|
# Betriebsarten "heating" und "active" ergänzt
|
|
# 2019-03-02 Readings für heating.boiler.sensors.temperature.commonSupply.value und
|
|
# heating.circuits.1.operating.modes.heating.active hinzugefügt
|
|
# Typo fixed ("Brenner_Be-t-riebsstunden")
|
|
# 2019-03-29 neue Readings:
|
|
# heating.circuits.1.operating.modes.dhwAndHeatingCooling.active 1
|
|
# heating.circuits.1.operating.modes.normalStandby.active 0
|
|
# heating.circuits.1.operating.programs.fixed.active 0
|
|
# heating.compressor.active 0
|
|
# heating.dhw.temperature.hysteresis.value 5
|
|
# heating.dhw.temperature.temp2.value 60
|
|
# Passwort wird bei "define" nur noch gesetzt, wenn noch kein Passwort gespeichert war
|
|
# Attribut "model" implementiert
|
|
# 2019-04-26 neue Readings für
|
|
# heating.gas.consumption.dhw.unit kilowattHour
|
|
# heating.gas.consumption.heating.unit kilowattHour
|
|
# heating.power.consumption.unit kilowattHour
|
|
# Typo in WW-Zirkulationspumpe_Zeitsteuerung_aktiv fixt
|
|
# 2019-06-01 neue Readings für
|
|
# heating.solar.power.production.day 3.984,3.797,5.8,5.5,6.771,5.77,5.441,9.477
|
|
# heating.solar.power.production.month
|
|
# heating.solar.power.production.unit kilowattHour
|
|
# heating.solar.power.production.week
|
|
# heating.solar.power.production.year
|
|
# heating.circuits.X.name (wird im Moment noch nicht von der API gefüllt!)
|
|
# Format der "Schedule" Readings in JSON geändert
|
|
# das Format von HKx-Urlaub_Start und _Ende ist jetzt YYYY-MM-TT.
|
|
# Wenn noch kein Urlaub aktiviert wurde, wird bei
|
|
# HKx-Urlaub_Start das Datum für _Ende auf den Folgetag gesetzt
|
|
# Dafür werden die Perl Module DateTime, Time:Piece und Time::Seconds
|
|
# benötigt (installieren mit apt install libdatetime-perl!)
|
|
#
|
|
# 2019-08-11 Dokumentation aktualisiert
|
|
# Das Reading 'stat' zeigt jetzt den "aggregatedStatus" an, der von der API geliefert wird
|
|
# Bsp: "Offline", "WorksProperly"
|
|
# Readings werden nur noch aktualisiert (und ein entsprechendes Event erzeugt),
|
|
# wenn sich ihr Wert geändert hat. "state" wird immer aktualisiert.
|
|
# Reading für Solarunterstützung hinzugefügt:
|
|
# "heating.solar.active" => "Solar_aktiv",
|
|
# "heating.solar.pumps.circuit.status" => "Solar_Pumpe_Status",
|
|
# "heating.solar.rechargeSuppression.status" => "Solar_Aufladeunterdrueckung_Status",
|
|
# "heating.solar.sensors.power.status" => "Solar_Sensor_Power_Status",
|
|
# "heating.solar.sensors.power.value" => "Solar_Sensor_Power",
|
|
# "heating.solar.sensors.temperature.collector.status" => "Solar_Sensor_Temperatur_Kollektor_Status",
|
|
# "heating.solar.sensors.temperature.collector.value" => "Solar_Sensor_Temperatur_Kollektor",
|
|
# "heating.solar.sensors.temperature.dhw.status" => "Solar_Sensor_Temperatur_WW_Status",
|
|
# "heating.solar.sensors.temperature.dhw.value" => "Solar_Sensor_Temperatur_WW",
|
|
# "heating.solar.statistics.hours" => "Solar_Sensor_Statistik_Stunden"
|
|
# ErrorListChanges (Fehlereintraege_Historie und Fehlereintraege_aktive) werden jetzt im JSON
|
|
# JSON Format ausgegeben (z.B.: "{"new":[],"current":[],"gone":[]}")
|
|
#
|
|
# 2019-09-07 Readings werden wieder erzeugt auch wenn sich der Wert nicht ändert
|
|
#
|
|
# 2019-11-23 Readings für "heating.power.consumption.total.*" hinzugefügt. Scheint identisch mit "heating.power.consumption.*"
|
|
# Behoben: Readings wurden nicht mehr aktualisiert, wenn in getResourceCallback die Resource nicht als JSON interpretiert werden konnte (Forum: #390)
|
|
# Behoben: vitoconnect bringt FHEM zum Absturz in Zeile 1376 (Forum: #391)
|
|
# Überwachung der Aktualität: Zeitpunkt des letzten Updates wird in State angezeigt (Forum #397)
|
|
#
|
|
# 2019-12-25 heating.solar.power.cumulativeProduced.value, heating.circuits.X.geofencing.active, heating.circuits.X.geofencing.status hinzugefügt
|
|
# Behoben: Readings wurden nicht mehr aktualisiert, wenn Resource an weiteren Stellen nicht als JSON interpretiert werden konnte(Forum: #390)
|
|
#
|
|
# 2020-03-02 Bei Aktionen wird nicht mehr auf defined($data) sondern auf ne "" getestet.
|
|
# 2020-04-05 s.o. 2. Versuch
|
|
#
|
|
# 2020-04-09 my $dir = path(AttrVal("global","logdir","log"));
|
|
#
|
|
# 2020-04-17 "Viessmann" Tippfehler gefixt
|
|
# Prototypen und "undef"s entfernt
|
|
#
|
|
# 2020-04-22 Reading heating.boiler.temperature.unit heating.operating.programs.holiday.active
|
|
# heating.operating.programs.holiday.end heating.operating.programs.holiday.start
|
|
# set Befehle hinzugefügt: Urlaub_Start, Urlaub_Ende, Urlaub_unschedule
|
|
# HKx-Name, HKx-Zeitsteuerung_Heizung, WW-Zeitplan, WW-Zirkulationspumpe_Zeitplan
|
|
#
|
|
# 2020-04-23 Refactoring (kein Einloggen mehr beim Ausführen einer Aktion)
|
|
# 2020-05-20 Neue Readings:
|
|
# heating.boiler.sensors.temperature.main.unit celsius
|
|
# heating.circuits.0.sensors.temperature.supply.unit celsius
|
|
# heating.dhw.sensors.temperature.hotWaterStorage.unit celsius
|
|
# heating.dhw.sensors.temperature.outlet.unit celsius
|
|
# heating.sensors.temperature.outside.unit celsius
|
|
# Fehlerbehandlung verbessert
|
|
# nur noch einloggen, wenn nötig (Token läuft nach 1h aus.)
|
|
#
|
|
# 2020-06-25 Fehlerbehandlung für API (statusCode 401 (UNAUTHORIZED), 404 (DEVICE_NOT_FOUND)
|
|
# und 429 (RATE_LIMIT_EXCEEDED) und 502 (DEVICE_COMMUNICATION_ERROR)
|
|
# Neue Readings für Vitodens 200-W B2HF-19 und Brennstoffzelle von Viessmann (PA2)
|
|
# Information aus dem GW auslesen (Attribut "vitoconnect_gw_readings" auf "1" setzen;
|
|
# noch unvollständig!)
|
|
#
|
|
# 2020-07-06 readings for heating.power.production.demandCoverage.* fixed
|
|
# bei logResponseOnce wird bei getCode angefangen damit auch gw.json neu erzeugt wird
|
|
#
|
|
# 2020-11-26 Bugfix für einige "set"-Kommandos für HK2 und HK3
|
|
#
|
|
# 2020-12-21 Neue Readings "heating.power.production.current.status" => "Stromproduktion_aktueller_Status",
|
|
# "heating.power.production.current.value" => "Stromproduktion",
|
|
# "heating.sensors.power.output.status" => "Sensor_Stromproduktion_Status",
|
|
# "heating.sensors.power.output.value" => "Sensor_Stromproduktion" und
|
|
# "heating.circuits.X.operating.programs.Y.demand" =>
|
|
# "HK(X+1)-Solltemperatur_Y_Anforderung" (X=0,1,2 und Y=normal,reduced,comfort)
|
|
# 2021-02-21 Umstieg auf Endpoint v2 zur Authorization
|
|
# *experimentell* Attribut vitoconnect_device
|
|
# Workaround für Forum #561
|
|
# Neue Readings für "*ValueReadAt"
|
|
#
|
|
# 2021-07-19 Anpassungen für privaten apiKey. Redirect URIs muss "http://localhost:4200/" sein.
|
|
# Nutzung des refresh_token
|
|
#
|
|
# 2021-07-19 neue Readings für heating.burners.0.*
|
|
#
|
|
# ToDo: timeout, intervall konfigurierbar machen
|
|
# Attribute implementieren und dokumentieren
|
|
# Mehrsprachigkeit
|
|
# Auswerten der Readings in getCode usw.
|
|
# devices/0 ? Was, wenn es mehrere Devices gibt?
|
|
# nach einem set Befehl Readings aktualisieren, vorher alten Timer löschen
|
|
# heating.circuits.0.operating.programs.holiday.changeEndDate action: end implementieren?
|
|
#
|
|
|
|
package main;
|
|
use strict;
|
|
use warnings;
|
|
use Time::HiRes qw(gettimeofday);
|
|
use JSON;
|
|
use HttpUtils;
|
|
use Encode qw(decode encode);
|
|
use Data::Dumper;
|
|
use Path::Tiny;
|
|
use DateTime;
|
|
use Time::Piece;
|
|
use Time::Seconds;
|
|
|
|
my $client_secret = "2e21faa1-db2c-4d0b-a10f-575fd372bc8c-575fd372bc8c";
|
|
my $callback_uri = "http://localhost:4200/";
|
|
my $apiURLBase = "https://api.viessmann-platform.io/iot/v1/equipment/";
|
|
my $apiURL = "https://api.viessmann.com/iot/v1/equipment/";
|
|
|
|
my $RequestList = {
|
|
"heating.boiler.serial.value" => "Kessel_Seriennummer",
|
|
"heating.boiler.temperature.value" => "Kessel_Solltemperatur",
|
|
"heating.boiler.sensors.temperature.commonSupply.status" =>
|
|
"Kessel_Common_Supply",
|
|
"heating.boiler.sensors.temperature.commonSupply.unit" =>
|
|
"Kessel_Common_Supply_Temperatur/Einheit",
|
|
"heating.boiler.sensors.temperature.commonSupply.value" =>
|
|
"Kessel_Common_Supply_Temperatur",
|
|
"heating.boiler.sensors.temperature.main.status" => "Kessel_Status",
|
|
"heating.boiler.sensors.temperature.main.unit" =>
|
|
"Kesseltemperatur/Einheit",
|
|
"heating.boiler.sensors.temperature.main.value" => "Kesseltemperatur",
|
|
"heating.boiler.temperature.unit" => "Kesseltemperatur/Einheit",
|
|
|
|
"heating.burner.active" => "Brenner_aktiv",
|
|
"heating.burner.automatic.status" => "Brenner_Status",
|
|
"heating.burner.automatic.errorCode" => "Brenner_Fehlercode",
|
|
"heating.burner.current.power.value" => "Brenner_Leistung",
|
|
"heating.burner.modulation.value" => "Brenner_Modulation",
|
|
"heating.burner.statistics.hours" => "Brenner_Betriebsstunden",
|
|
"heating.burner.statistics.starts" => "Brenner_Starts",
|
|
|
|
"heating.burners.0.active" => "Brenner_1_aktiv",
|
|
"heating.burners.0.modulation.unit" => "Brenner_1_Modulation/Einheit",
|
|
"heating.burners.0.modulation.value" => "Brenner_1_Modulation",
|
|
"heating.burners.0.statistics.hours" => "Brenner_1_Betriebsstunden",
|
|
"heating.burners.0.statistics.starts" => "Brenner_1_Starts",
|
|
|
|
"heating.circuits.enabled" => "Aktive_Heizkreise",
|
|
"heating.circuits.0.active" => "HK1-aktiv",
|
|
"heating.circuits.0.type" => "HK1-Typ",
|
|
"heating.circuits.0.circulation.pump.status" => "HK1-Zirkulationspumpe",
|
|
"heating.circuits.0.circulation.schedule.active" =>
|
|
"HK1-Zeitsteuerung_Zirkulation_aktiv",
|
|
"heating.circuits.0.circulation.schedule.entries" =>
|
|
"HK1-Zeitsteuerung_Zirkulation",
|
|
"heating.circuits.0.frostprotection.status" => "HK1-Frostschutz_Status",
|
|
"heating.circuits.0.geofencing.active" => "HK1-Geofencing",
|
|
"heating.circuits.0.geofencing.status" => "HK1-Geofencing_Status",
|
|
"heating.circuits.0.heating.curve.shift" => "HK1-Heizkurve-Niveau",
|
|
"heating.circuits.0.heating.curve.slope" => "HK1-Heizkurve-Steigung",
|
|
"heating.circuits.0.heating.schedule.active" =>
|
|
"HK1-Zeitsteuerung_Heizung_aktiv",
|
|
"heating.circuits.0.heating.schedule.entries" =>
|
|
"HK1-Zeitsteuerung_Heizung",
|
|
"heating.circuits.0.name" => "HK1-Name",
|
|
"heating.circuits.0.operating.modes.active.value" => "HK1-Betriebsart",
|
|
"heating.circuits.0.operating.modes.dhw.active" => "HK1-WW_aktiv",
|
|
"heating.circuits.0.operating.modes.dhwAndHeating.active" =>
|
|
"HK1-WW_und_Heizen_aktiv",
|
|
"heating.circuits.0.operating.modes.dhwAndHeatingCooling.active" =>
|
|
"HK1-WW_und_Heizen_Kuehlen_aktiv",
|
|
"heating.circuits.0.operating.modes.forcedNormal.active" =>
|
|
"HK1-Solltemperatur_erzwungen",
|
|
"heating.circuits.0.operating.modes.forcedReduced.active" =>
|
|
"HK1-Reduzierte_Temperatur_erzwungen",
|
|
"heating.circuits.0.operating.modes.heating.active" => "HK1-heizen_aktiv",
|
|
"heating.circuits.0.operating.modes.normalStandby.active" =>
|
|
"HK1-Normal_Standby_aktiv",
|
|
"heating.circuits.0.operating.modes.standby.active" => "HK1-Standby_aktiv",
|
|
"heating.circuits.0.operating.programs.active.value" =>
|
|
"HK1-Programmstatus",
|
|
"heating.circuits.0.operating.programs.comfort.active" =>
|
|
"HK1-Solltemperatur_comfort_aktiv",
|
|
"heating.circuits.0.operating.programs.comfort.demand" =>
|
|
"HK1-Solltemperatur_comfort_Anforderung",
|
|
"heating.circuits.0.operating.programs.comfort.temperature" =>
|
|
"HK1-Solltemperatur_comfort",
|
|
"heating.circuits.0.operating.programs.eco.active" =>
|
|
"HK1-Solltemperatur_eco_aktiv",
|
|
"heating.circuits.0.operating.programs.eco.temperature" =>
|
|
"HK1-Solltemperatur_eco",
|
|
"heating.circuits.0.operating.programs.external.active" =>
|
|
"HK1-External_aktiv",
|
|
"heating.circuits.0.operating.programs.external.temperature" =>
|
|
"HK1-External_Temperatur",
|
|
"heating.circuits.0.operating.programs.fixed.active" => "HK1-Fixed_aktiv",
|
|
"heating.circuits.0.operating.programs.forcedLastFromSchedule.active" =>
|
|
"HK1-forcedLastFromSchedule_aktiv",
|
|
"heating.circuits.0.operating.programs.holidayAtHome.active" =>
|
|
"HK1-HolidayAtHome_aktiv",
|
|
"heating.circuits.0.operating.programs.holidayAtHome.end" =>
|
|
"HK1-HolidayAtHome_Ende",
|
|
"heating.circuits.0.operating.programs.holidayAtHome.start" =>
|
|
"HK1-HolidayAtHome_Start",
|
|
"heating.circuits.0.operating.programs.holiday.active" =>
|
|
"HK1-Urlaub_aktiv",
|
|
"heating.circuits.0.operating.programs.holiday.start" => "HK1-Urlaub_Start",
|
|
"heating.circuits.0.operating.programs.holiday.end" => "HK1-Urlaub_Ende",
|
|
"heating.circuits.0.operating.programs.normal.active" =>
|
|
"HK1-Solltemperatur_aktiv",
|
|
"heating.circuits.0.operating.programs.normal.demand" =>
|
|
"HK1-Solltemperatur_Anforderung",
|
|
"heating.circuits.0.operating.programs.normal.temperature" =>
|
|
"HK1-Solltemperatur_normal",
|
|
"heating.circuits.0.operating.programs.reduced.active" =>
|
|
"HK1-Solltemperatur_reduziert_aktiv",
|
|
"heating.circuits.0.operating.programs.reduced.demand" =>
|
|
"HK1-Solltemperatur_reduziert_Anforderung",
|
|
"heating.circuits.0.operating.programs.reduced.temperature" =>
|
|
"HK1-Solltemperatur_reduziert",
|
|
"heating.circuits.0.operating.programs.summerEco.active" =>
|
|
"HK1-Solltemperatur_SummerEco_aktiv",
|
|
"heating.circuits.0.operating.programs.standby.active" =>
|
|
"HK1-Standby_aktiv",
|
|
"heating.circuits.0.zone.mode.active" => "HK1-ZoneMode_aktive",
|
|
"heating.circuits.0.sensors.temperature.room.status" => "HK1-Raum_Status",
|
|
"heating.circuits.0.sensors.temperature.room.value" =>
|
|
"HK1-Raum_Temperatur",
|
|
"heating.circuits.0.sensors.temperature.supply.status" =>
|
|
"HK1-Vorlauftemperatur_aktiv",
|
|
"heating.circuits.0.sensors.temperature.supply.unit" =>
|
|
"HK1-Vorlauftemperatur/Einheit",
|
|
"heating.circuits.0.sensors.temperature.supply.value" =>
|
|
"HK1-Vorlauftemperatur",
|
|
"heating.circuits.0.zone.mode.active" => "HK1-ZoneMode_aktive",
|
|
|
|
"heating.circuits.1.active" => "HK2-aktiv",
|
|
"heating.circuits.1.type" => "HK2-Typ",
|
|
"heating.circuits.1.circulation.pump.status" => "HK2-Zirkulationspumpe",
|
|
"heating.circuits.1.circulation.schedule.active" =>
|
|
"HK2-Zeitsteuerung_Zirkulation_aktiv",
|
|
"heating.circuits.1.circulation.schedule.entries" =>
|
|
"HK2-Zeitsteuerung_Zirkulation",
|
|
"heating.circuits.1.frostprotection.status" => "HK2-Frostschutz_Status",
|
|
"heating.circuits.1.geofencing.active" => "HK2-Geofencing",
|
|
"heating.circuits.1.geofencing.status" => "HK2-Geofencing_Status",
|
|
"heating.circuits.1.heating.curve.shift" => "HK2-Heizkurve-Niveau",
|
|
"heating.circuits.1.heating.curve.slope" => "HK2-Heizkurve-Steigung",
|
|
"heating.circuits.1.heating.schedule.active" =>
|
|
"HK2-Zeitsteuerung_Heizung_aktiv",
|
|
"heating.circuits.1.heating.schedule.entries" =>
|
|
"HK2-Zeitsteuerung_Heizung",
|
|
"heating.circuits.1.name" => "HK2-Name",
|
|
"heating.circuits.1.operating.modes.active.value" => "HK2-Betriebsart",
|
|
"heating.circuits.1.operating.modes.dhw.active" => "HK2-WW_aktiv",
|
|
"heating.circuits.1.operating.modes.dhwAndHeating.active" =>
|
|
"HK2-WW_und_Heizen_aktiv",
|
|
"heating.circuits.1.operating.modes.dhwAndHeatingCooling.active" =>
|
|
"HK2-WW_und_Heizen_Kuehlen_aktiv",
|
|
"heating.circuits.1.operating.modes.forcedNormal.active" =>
|
|
"HK2-Solltemperatur_erzwungen",
|
|
"heating.circuits.1.operating.modes.forcedReduced.active" =>
|
|
"HK2-Reduzierte_Temperatur_erzwungen",
|
|
"heating.circuits.1.operating.modes.heating.active" => "HK2-heizen_aktiv",
|
|
"heating.circuits.1.operating.modes.normalStandby.active" =>
|
|
"HK2-Normal_Standby_aktiv",
|
|
"heating.circuits.1.operating.modes.standby.active" => "HK2-Standby_aktiv",
|
|
"heating.circuits.1.operating.programs.active.value" =>
|
|
"HK2-Programmstatus",
|
|
"heating.circuits.1.operating.programs.comfort.active" =>
|
|
"HK2-Solltemperatur_comfort_aktiv",
|
|
"heating.circuits.1.operating.programs.comfort.demand" =>
|
|
"HK2-Solltemperatur_comfort_Anforderung",
|
|
"heating.circuits.1.operating.programs.comfort.temperature" =>
|
|
"HK2-Solltemperatur_comfort",
|
|
"heating.circuits.1.operating.programs.eco.active" =>
|
|
"HK2-Solltemperatur_eco_aktiv",
|
|
"heating.circuits.1.operating.programs.eco.temperature" =>
|
|
"HK2-Solltemperatur_eco",
|
|
"heating.circuits.1.operating.programs.external.active" =>
|
|
"HK2-External_aktiv",
|
|
"heating.circuits.1.operating.programs.external.temperature" =>
|
|
"HK2-External_Temperatur",
|
|
"heating.circuits.1.operating.programs.fixed.active" => "HK2-Fixed_aktiv",
|
|
"heating.circuits.1.operating.programs.forcedLastFromSchedule.active" =>
|
|
"HK2-forcedLastFromSchedule_aktiv",
|
|
"heating.circuits.1.operating.programs.holidayAtHome.active" =>
|
|
"HK2-HolidayAtHome_aktiv",
|
|
"heating.circuits.1.operating.programs.holidayAtHome.end" =>
|
|
"HK2-HolidayAtHome_Ende",
|
|
"heating.circuits.1.operating.programs.holidayAtHome.start" =>
|
|
"HK2-HolidayAtHome_Start",
|
|
"heating.circuits.1.operating.programs.holiday.active" =>
|
|
"HK2-Urlaub_aktiv",
|
|
"heating.circuits.1.operating.programs.holiday.start" => "HK2-Urlaub_Start",
|
|
"heating.circuits.1.operating.programs.holiday.end" => "HK2-Urlaub_Ende",
|
|
"heating.circuits.1.operating.programs.normal.active" =>
|
|
"HK2-Solltemperatur_aktiv",
|
|
"heating.circuits.1.operating.programs.normal.demand" =>
|
|
"HK2-Solltemperatur_Anforderung",
|
|
"heating.circuits.1.operating.programs.normal.temperature" =>
|
|
"HK2-Solltemperatur_normal",
|
|
"heating.circuits.1.operating.programs.reduced.active" =>
|
|
"HK2-Solltemperatur_reduziert_aktiv",
|
|
"heating.circuits.1.operating.programs.reduced.demand" =>
|
|
"HK2-Solltemperatur_reduziert_Anforderung",
|
|
"heating.circuits.1.operating.programs.reduced.temperature" =>
|
|
"HK2-Solltemperatur_reduziert",
|
|
"heating.circuits.1.operating.programs.summerEco.active" =>
|
|
"HK2-Solltemperatur_SummerEco_aktiv",
|
|
"heating.circuits.1.operating.programs.standby.active" =>
|
|
"HK2-Standby_aktiv",
|
|
"heating.circuits.1.sensors.temperature.room.status" => "HK2-Raum_Status",
|
|
"heating.circuits.1.sensors.temperature.room.value" =>
|
|
"HK2-Raum_Temperatur",
|
|
"heating.circuits.1.sensors.temperature.supply.status" =>
|
|
"HK2-Vorlauftemperatur_aktiv",
|
|
"heating.circuits.1.sensors.temperature.supply.unit" =>
|
|
"HK2-Vorlauftemperatur/Einheit",
|
|
"heating.circuits.1.sensors.temperature.supply.value" =>
|
|
"HK2-Vorlauftemperatur",
|
|
"heating.circuits.1.zone.mode.active" => "HK2-ZoneMode_aktive",
|
|
|
|
"heating.circuits.2.active" => "HK3-aktiv",
|
|
"heating.circuits.2.type" => "HK3-Typ",
|
|
"heating.circuits.2.circulation.pump.status" => "HK3-Zirkulationspumpe",
|
|
"heating.circuits.2.circulation.schedule.active" =>
|
|
"HK3-Zeitsteuerung_Zirkulation_aktiv",
|
|
"heating.circuits.2.circulation.schedule.entries" =>
|
|
"HK3-Zeitsteuerung_Zirkulation",
|
|
"heating.circuits.2.frostprotection.status" => "HK3-Frostschutz_Status",
|
|
"heating.circuits.2.geofencing.active" => "HK3-Geofencing",
|
|
"heating.circuits.2.geofencing.status" => "HK3-Geofencing_Status",
|
|
"heating.circuits.2.heating.curve.shift" => "HK3-Heizkurve-Niveau",
|
|
"heating.circuits.2.heating.curve.slope" => "HK3-Heizkurve-Steigung",
|
|
"heating.circuits.2.heating.schedule.active" =>
|
|
"HK3-Zeitsteuerung_Heizung_aktiv",
|
|
"heating.circuits.2.heating.schedule.entries" =>
|
|
"HK3-Zeitsteuerung_Heizung",
|
|
"heating.circuits.2.name" => "HK3-Name",
|
|
"heating.circuits.2.operating.modes.active.value" => "HK3-Betriebsart",
|
|
"heating.circuits.2.operating.modes.dhw.active" => "HK3-WW_aktiv",
|
|
"heating.circuits.2.operating.modes.dhwAndHeating.active" =>
|
|
"HK3-WW_und_Heizen_aktiv",
|
|
"heating.circuits.2.operating.modes.dhwAndHeatingCooling.active" =>
|
|
"HK3-WW_und_Heizen_Kuehlen_aktiv",
|
|
"heating.circuits.2.operating.modes.forcedNormal.active" =>
|
|
"HK3-Solltemperatur_erzwungen",
|
|
"heating.circuits.2.operating.modes.forcedReduced.active" =>
|
|
"HK3-Reduzierte_Temperatur_erzwungen",
|
|
"heating.circuits.2.operating.modes.heating.active" => "HK3-heizen_aktiv",
|
|
"heating.circuits.2.operating.modes.normalStandby.active" =>
|
|
"HK3-Normal_Standby_aktiv",
|
|
"heating.circuits.2.operating.modes.standby.active" => "HK3-Standby_aktiv",
|
|
"heating.circuits.2.operating.programs.active.value" =>
|
|
"HK3-Programmstatus",
|
|
"heating.circuits.2.operating.programs.comfort.active" =>
|
|
"HK3-Solltemperatur_comfort_aktiv",
|
|
"heating.circuits.2.operating.programs.comfort.demand" =>
|
|
"HK3-Solltemperatur_comfort_Anforderung",
|
|
"heating.circuits.2.operating.programs.comfort.temperature" =>
|
|
"HK3-Solltemperatur_comfort",
|
|
"heating.circuits.2.operating.programs.eco.active" =>
|
|
"HK3-Solltemperatur_eco_aktiv",
|
|
"heating.circuits.2.operating.programs.eco.temperature" =>
|
|
"HK3-Solltemperatur_eco",
|
|
"heating.circuits.2.operating.programs.external.active" =>
|
|
"HK3-External_aktiv",
|
|
"heating.circuits.2.operating.programs.external.temperature" =>
|
|
"HK3-External_Temperatur",
|
|
"heating.circuits.2.operating.programs.fixed.active" => "HK3-Fixed_aktiv",
|
|
"heating.circuits.2.operating.programs.forcedLastFromSchedule.active" =>
|
|
"HK3-forcedLastFromSchedule_aktiv",
|
|
"heating.circuits.2.operating.programs.holidayAtHome.active" =>
|
|
"HK3-HolidayAtHome_aktiv",
|
|
"heating.circuits.2.operating.programs.holidayAtHome.end" =>
|
|
"HK3-HolidayAtHome_Ende",
|
|
"heating.circuits.2.operating.programs.holidayAtHome.start" =>
|
|
"HK3-HolidayAtHome_Start",
|
|
"heating.circuits.2.operating.programs.holiday.active" =>
|
|
"HK3-Urlaub_aktiv",
|
|
"heating.circuits.2.operating.programs.holiday.start" => "HK3-Urlaub_Start",
|
|
"heating.circuits.2.operating.programs.holiday.end" => "HK3-Urlaub_Ende",
|
|
"heating.circuits.2.operating.programs.normal.active" =>
|
|
"HK3-Solltemperatur_aktiv",
|
|
"heating.circuits.2.operating.programs.normal.demand" =>
|
|
"HK3-Solltemperatur_Anforderung",
|
|
"heating.circuits.2.operating.programs.normal.temperature" =>
|
|
"HK3-Solltemperatur_normal",
|
|
"heating.circuits.2.operating.programs.reduced.active" =>
|
|
"HK3-Solltemperatur_reduziert_aktiv",
|
|
"heating.circuits.2.operating.programs.reduced.demand" =>
|
|
"HK3-Solltemperatur_reduziert_Anforderung",
|
|
"heating.circuits.2.operating.programs.reduced.temperature" =>
|
|
"HK3-Solltemperatur_reduziert",
|
|
"heating.circuits.2.operating.programs.summerEco.active" =>
|
|
"HK3-Solltemperatur_SummerEco_aktiv",
|
|
"heating.circuits.2.operating.programs.standby.active" =>
|
|
"HK3-Standby_aktiv",
|
|
"heating.circuits.2.sensors.temperature.room.status" => "HK3-Raum_Status",
|
|
"heating.circuits.2.sensors.temperature.room.value" =>
|
|
"HK3-Raum_Temperatur",
|
|
"heating.circuits.2.sensors.temperature.supply.status" =>
|
|
"HK3-Vorlauftemperatur_aktiv",
|
|
"heating.circuits.2.sensors.temperature.supply.unit" =>
|
|
"HK3-Vorlauftemperatur/Einheit",
|
|
"heating.circuits.2.sensors.temperature.supply.value" =>
|
|
"HK3-Vorlauftemperatur",
|
|
"heating.circuits.2.zone.mode.active" => "HK2-ZoneMode_aktive",
|
|
|
|
"heating.circuits.3.geofencing.active" => "HK4-Geofencing",
|
|
"heating.circuits.3.geofencing.status" => "HK4-Geofencing_Status",
|
|
"heating.circuits.3.operating.programs.summerEco.active" =>
|
|
"HK4-Solltemperatur_SummerEco_aktiv",
|
|
"heating.circuits.3.zone.mode.active" => "HK4-ZoneMode_aktive",
|
|
|
|
"heating.compressor.active" => "Kompressor_aktiv",
|
|
"heating.configuration.multiFamilyHouse.active" => "Mehrfamilenhaus_aktiv",
|
|
"heating.configuration.regulation.mode" => "Regulationmode",
|
|
"heating.controller.serial.value" => "Controller_Seriennummer",
|
|
"heating.device.time.offset.value" => "Device_Time_Offset",
|
|
"heating.dhw.active" => "WW-aktiv",
|
|
"heating.dhw.status" => "WW-Status",
|
|
"heating.dhw.charging.active" => "WW-Aufladung",
|
|
|
|
"heating.dhw.charging.level.bottom" => "WW-Speichertemperatur_unten",
|
|
"heating.dhw.charging.level.middle" => "WW-Speichertemperatur_mitte",
|
|
"heating.dhw.charging.level.top" => "WW-Speichertemperatur_oben",
|
|
"heating.dhw.charging.level.value" => "WW-Speicherladung",
|
|
|
|
"heating.dhw.oneTimeCharge.active" => "WW-einmaliges_Aufladen",
|
|
"heating.dhw.pumps.circulation.schedule.active" =>
|
|
"WW-Zirkulationspumpe_Zeitsteuerung_aktiv",
|
|
"heating.dhw.pumps.circulation.schedule.entries" =>
|
|
"WW-Zirkulationspumpe_Zeitplan",
|
|
"heating.dhw.pumps.circulation.status" => "WW-Zirkulationspumpe_Status",
|
|
"heating.dhw.pumps.primary.status" => "WW-Zirkulationspumpe_primaer",
|
|
"heating.dhw.sensors.temperature.outlet.status" =>
|
|
"WW-Sensoren_Auslauf_Status",
|
|
"heating.dhw.sensors.temperature.outlet.unit" =>
|
|
"WW-Sensoren_Auslauf_Wert/Einheit",
|
|
"heating.dhw.sensors.temperature.outlet.value" =>
|
|
"WW-Sensoren_Auslauf_Wert",
|
|
"heating.dhw.temperature.main.value" => "WW-Haupttemperatur",
|
|
"heating.dhw.temperature.hysteresis.value" => "WW-Hysterese",
|
|
"heating.dhw.temperature.temp2.value" => "WW-Temperatur_2",
|
|
"heating.dhw.sensors.temperature.hotWaterStorage.status" =>
|
|
"WW-Temperatur_aktiv",
|
|
"heating.dhw.sensors.temperature.hotWaterStorage.unit" =>
|
|
"WW-Isttemperatur/Einheit",
|
|
"heating.dhw.sensors.temperature.hotWaterStorage.value" =>
|
|
"WW-Isttemperatur",
|
|
"heating.dhw.temperature.value" => "WW-Solltemperatur",
|
|
"heating.dhw.schedule.active" => "WW-zeitgesteuert_aktiv",
|
|
"heating.dhw.schedule.entries" => "WW-Zeitplan",
|
|
|
|
"heating.errors.active.entries" => "Fehlereintraege_aktive",
|
|
"heating.errors.history.entries" => "Fehlereintraege_Historie",
|
|
|
|
"heating.flue.sensors.temperature.main.status" => "Abgassensor_Status",
|
|
"heating.flue.sensors.temperature.main.unit" =>
|
|
"Abgassensor_Temperatur/Einheit",
|
|
"heating.flue.sensors.temperature.main.value" => "Abgassensor_Temperatur",
|
|
|
|
"heating.fuelCell.operating.modes.active.value" => "Brennstoffzelle_Mode",
|
|
"heating.fuelCell.operating.modes.ecological.active" =>
|
|
"Brennstoffzelle_Mode_Ecological",
|
|
"heating.fuelCell.operating.modes.economical.active" =>
|
|
"Brennstoffzelle_Mode_Economical",
|
|
"heating.fuelCell.operating.modes.heatControlled.active" =>
|
|
"Brennstoffzelle_wärmegesteuert",
|
|
"heating.fuelCell.operating.modes.maintenance.active" =>
|
|
"Brennstoffzelle_Wartung",
|
|
"heating.fuelCell.operating.modes.standby.active" =>
|
|
"Brennstoffzelle_Standby",
|
|
"heating.fuelCell.operating.phase.value" => "Brennstoffzelle_Phase",
|
|
"heating.fuelCell.power.production.day" =>
|
|
"Brennstoffzelle_Stromproduktion/Tag",
|
|
"heating.fuelCell.power.production.month" =>
|
|
"Brennstoffzelle_Stromproduktion/Monat",
|
|
"heating.fuelCell.power.production.unit" =>
|
|
"Brennstoffzelle_Stromproduktion/Einheit",
|
|
"heating.fuelCell.power.production.week" =>
|
|
"Brennstoffzelle_Stromproduktion/Woche",
|
|
"heating.fuelCell.power.production.year" =>
|
|
"Brennstoffzelle_Stromproduktion/Jahr",
|
|
"heating.fuelCell.sensors.temperature.return.status" =>
|
|
"Brennstoffzelle_Temperatur_Ruecklauf_Status",
|
|
"heating.fuelCell.sensors.temperature.return.unit" =>
|
|
"Brennstoffzelle_Temperatur_Ruecklauf/Einheit",
|
|
"heating.fuelCell.sensors.temperature.return.value" =>
|
|
"Brennstoffzelle_Temperatur_Ruecklauf",
|
|
"heating.fuelCell.sensors.temperature.supply.status" =>
|
|
"Brennstoffzelle_Temperatur_Vorlauf_Status",
|
|
"heating.fuelCell.sensors.temperature.supply.unit" =>
|
|
"Brennstoffzelle_Temperatur_Vorlauf/Einheit",
|
|
"heating.fuelCell.sensors.temperature.supply.value" =>
|
|
"Brennstoffzelle_Temperatur_Vorlauf",
|
|
"heating.fuelCell.statistics.availabilityRate" =>
|
|
"Brennstoffzelle_Statistic_Verfügbarkeit",
|
|
"heating.fuelCell.statistics.insertions" =>
|
|
"Brennstoffzelle_Statistic_Einschub",
|
|
"heating.fuelCell.statistics.operationHours" =>
|
|
"Brennstoffzelle_Statistic_Bestriebsstunden",
|
|
"heating.fuelCell.statistics.productionHours" =>
|
|
"Brennstoffzelle_Statistic_Produktionsstunden",
|
|
"heating.fuelCell.statistics.productionStarts" =>
|
|
"Brennstoffzelle_Statistic_Produktionsstarts",
|
|
|
|
"heating.gas.consumption.dhw.day" => "Gasverbrauch_WW/Tag",
|
|
"heating.gas.consumption.dhw.week" => "Gasverbrauch_WW/Woche",
|
|
"heating.gas.consumption.dhw.month" => "Gasverbrauch_WW/Monat",
|
|
"heating.gas.consumption.dhw.year" => "Gasverbrauch_WW/Jahr",
|
|
"heating.gas.consumption.dhw.dayValueReadAt" =>
|
|
"Gasverbrauch_WW/Tag_gelesen_am",
|
|
"heating.gas.consumption.dhw.weekValueReadAt" =>
|
|
"Gasverbrauch_WW/Woche_gelesen_am",
|
|
"heating.gas.consumption.dhw.monthValueReadAt" =>
|
|
"Gasverbrauch_WW/Monat_gelesen_am",
|
|
"heating.gas.consumption.dhw.yearValueReadAt" =>
|
|
"Gasverbrauch_WW/Jahr_gelesen_am",
|
|
"heating.gas.consumption.dhw.unit" => "Gasverbrauch_WW/Einheit",
|
|
|
|
"heating.gas.consumption.heating.day" => "Gasverbrauch_Heizung/Tag",
|
|
"heating.gas.consumption.heating.week" => "Gasverbrauch_Heizung/Woche",
|
|
"heating.gas.consumption.heating.month" => "Gasverbrauch_Heizung/Monat",
|
|
"heating.gas.consumption.heating.year" => "Gasverbrauch_Heizung/Jahr",
|
|
"heating.gas.consumption.heating.dayValueReadAt" =>
|
|
"Gasverbrauch_Heizung/Tag_gelesen_am",
|
|
"heating.gas.consumption.heating.weekValueReadAt" =>
|
|
"Gasverbrauch_Heizung/Woche_gelesen_am",
|
|
"heating.gas.consumption.heating.monthValueReadAt" =>
|
|
"Gasverbrauch_Heizung/Monat_gelesen_am",
|
|
"heating.gas.consumption.heating.yearValueReadAt" =>
|
|
"Gasverbrauch_Heizung/Jahr_gelesen_am",
|
|
"heating.gas.consumption.heating.unit" => "Gasverbrauch_Heizung/Einheit",
|
|
"heating.gas.consumption.total.day" => "Gasverbrauch_Total/Tag",
|
|
"heating.gas.consumption.total.month" => "Gasverbrauch_Total/Monat",
|
|
"heating.gas.consumption.total.unit" => "Gasverbrauch_Total/Einheit",
|
|
"heating.gas.consumption.total.week" => "Gasverbrauch_Total/Woche",
|
|
"heating.gas.consumption.total.year" => "Gasverbrauch_Total/Jahr",
|
|
"heating.gas.consumption.total.dayValueReadAt" =>
|
|
"Gasverbrauch_Total/Tag_gelesen_am",
|
|
"heating.gas.consumption.total.monthValueReadAt" =>
|
|
"Gasverbrauch_Total/Woche_gelesen_am",
|
|
"heating.gas.consumption.total.weekValueReadAt" =>
|
|
"Gasverbrauch_Total/Woche_gelesen_am",
|
|
"heating.gas.consumption.total.yearValueReadAt" =>
|
|
"Gasverbrauch_Total/Jahr_gelesen_am",
|
|
|
|
"heating.gas.consumption.fuelCell.day" =>
|
|
"Gasverbrauch_Brennstoffzelle/Tag",
|
|
"heating.gas.consumption.fuelCell.week" =>
|
|
"Gasverbrauch_Brennstoffzelle/Woche",
|
|
"heating.gas.consumption.fuelCell.month" =>
|
|
"Gasverbrauch_Brennstoffzelle/Monat",
|
|
"heating.gas.consumption.fuelCell.year" =>
|
|
"Gasverbrauch_Brennstoffzelle/Jahr",
|
|
"heating.gas.consumption.fuelCell.unit" =>
|
|
"Gasverbrauch_Brennstoffzelle/Einheit",
|
|
|
|
"heating.heat.production.day" => "Wärmeproduktion/Tag",
|
|
"heating.heat.production.month" => "Wärmeproduktion/Woche",
|
|
"heating.heat.production.unit" => "Wärmeproduktion/Einheit",
|
|
"heating.heat.production.week" => "Wärmeproduktion/Woche",
|
|
"heating.heat.production.year" => "Wärmeproduktion/Jahr",
|
|
|
|
"heating.operating.programs.holiday.active" => "Urlaub_aktiv",
|
|
"heating.operating.programs.holiday.end" => "Urlaub_Ende",
|
|
"heating.operating.programs.holiday.start" => "Urlaub_Start",
|
|
|
|
"heating.operating.programs.holidayAtHome.active" => "holidayAtHome_aktiv",
|
|
"heating.operating.programs.holidayAtHome.end" => "holidayAtHome_Ende",
|
|
"heating.operating.programs.holidayAtHome.start" => "holidayAtHome_Start",
|
|
|
|
"heating.power.consumption.day" => "Stromverbrauch/Tag",
|
|
"heating.power.consumption.month" => "Stromverbrauch/Monat",
|
|
"heating.power.consumption.week" => "Stromverbrauch/Woche",
|
|
"heating.power.consumption.year" => "Stromverbrauch/Jahr",
|
|
"heating.power.consumption.unit" => "Stromverbrauch/Einheit",
|
|
|
|
"heating.power.consumption.dhw.day" => "Stromverbrauch_WW/Tag",
|
|
"heating.power.consumption.dhw.month" => "Stromverbrauch_WW/Monat",
|
|
"heating.power.consumption.dhw.week" => "Stromverbrauch_WW/Woche",
|
|
"heating.power.consumption.dhw.year" => "Stromverbrauch_WW/Jahr",
|
|
"heating.power.consumption.dhw.unit" => "Stromverbrauch_WW/Einheit",
|
|
|
|
"heating.power.consumption.heating.day" => "Stromverbrauch_Heizung/Tag",
|
|
"heating.power.consumption.heating.month" => "Stromverbrauch_Heizung/Monat",
|
|
"heating.power.consumption.heating.week" => "Stromverbrauch_Heizung/Woche",
|
|
"heating.power.consumption.heating.year" => "Stromverbrauch_Heizung/Jahr",
|
|
"heating.power.consumption.heating.unit" =>
|
|
"Stromverbrauch_Heizung/Einheit",
|
|
|
|
"heating.power.consumption.total.day" => "Stromverbrauch_Total/Tag",
|
|
"heating.power.consumption.total.month" => "Stromverbrauch_Total/Monat",
|
|
"heating.power.consumption.total.week" => "Stromverbrauch_Total/Woche",
|
|
"heating.power.consumption.total.year" => "Stromverbrauch_Total/Jahr",
|
|
"heating.power.consumption.total.dayValueReadAt" =>
|
|
"Stromverbrauch_Total/Tag_gelesen_am",
|
|
"heating.power.consumption.total.monthValueReadAt" =>
|
|
"Stromverbrauch_Total/Monat_gelesen_am",
|
|
"heating.power.consumption.total.weekValueReadAt" =>
|
|
"Stromverbrauch_Total/Woche_gelesen_am",
|
|
"heating.power.consumption.total.yearValueReadAt" =>
|
|
"Stromverbrauch_Total/Jahr_gelesen_am",
|
|
"heating.power.consumption.total.unit" => "Stromverbrauch_Total/Einheit",
|
|
|
|
"heating.power.production.current.status" =>
|
|
"Stromproduktion_aktueller_Status",
|
|
"heating.power.production.current.value" => "Stromproduktion",
|
|
|
|
"heating.power.production.demandCoverage.current.unit" =>
|
|
"Stromproduktion_Bedarfsabdeckung/Einheit",
|
|
"heating.power.production.demandCoverage.current.value" =>
|
|
"Stromproduktion_Bedarfsabdeckung",
|
|
"heating.power.production.demandCoverage.total.day" =>
|
|
"Stromproduktion_Bedarfsabdeckung_total/Tag",
|
|
"heating.power.production.demandCoverage.total.month" =>
|
|
"Stromproduktion_Bedarfsabdeckung_total/Monat",
|
|
"heating.power.production.demandCoverage.total.unit" =>
|
|
"Stromproduktion_Bedarfsabdeckung_total/Einheit",
|
|
"heating.power.production.demandCoverage.total.week" =>
|
|
"Stromproduktion_Bedarfsabdeckung_total/Woche",
|
|
"heating.power.production.demandCoverage.total.year" =>
|
|
"Stromproduktion_Bedarfsabdeckung_total/Jahr",
|
|
|
|
"heating.power.production.day" => "Stromproduktion_Total/Tag",
|
|
"heating.power.production.month" => "Stromproduktion_Total/Monat",
|
|
"heating.power.production.productionCoverage.current.unit" =>
|
|
"Stromproduktion_Produktionsabdeckung/Einheit",
|
|
"heating.power.production.productionCoverage.current.value" =>
|
|
"Stromproduktion_Produktionsabdeckung",
|
|
"heating.power.production.productionCoverage.total.day" =>
|
|
"Stromproduktion_Produktionsabdeckung_Total/Tag",
|
|
"heating.power.production.productionCoverage.total.month" =>
|
|
"Stromproduktion_Produktionsabdeckung_Total/Monat",
|
|
"heating.power.production.productionCoverage.total.unit" =>
|
|
"Stromproduktion_Produktionsabdeckung_Total/Einheit",
|
|
"heating.power.production.productionCoverage.total.week" =>
|
|
"Stromproduktion_Produktionsabdeckung_Total/Woche",
|
|
"heating.power.production.productionCoverage.total.year" =>
|
|
"Stromproduktion_Produktionsabdeckung_Total/Jahr",
|
|
"heating.power.production.unit" => "Stromproduktion_Total/Einheit",
|
|
"heating.power.production.week" => "Stromproduktion_Total/Woche",
|
|
"heating.power.production.year" => "Stromproduktion_Total/Jahr",
|
|
|
|
"heating.power.purchase.current.unit" => "Stromkauf/Einheit",
|
|
"heating.power.purchase.current.value" => "Stromkauf",
|
|
"heating.power.sold.current.unit" => "Stromverkauf/Einheit",
|
|
"heating.power.sold.current.value" => "Stromverkauf",
|
|
"heating.power.sold.day" => "Stromverkauf/Tag",
|
|
"heating.power.sold.month" => "Stromverkauf/Monat",
|
|
"heating.power.sold.unit" => "Stromverkauf/Einheit",
|
|
"heating.power.sold.week" => "Stromverkauf/Woche",
|
|
"heating.power.sold.year" => "Stromverkauf/Jahr",
|
|
|
|
"heating.sensors.pressure.supply.status" => "Drucksensor_Vorlauf_Status",
|
|
"heating.sensors.pressure.supply.unit" => "Drucksensor_Vorlauf/Einheit",
|
|
"heating.sensors.pressure.supply.value" => "Drucksensor_Vorlauf",
|
|
|
|
"heating.sensors.power.output.status" => "Sensor_Stromproduktion_Status",
|
|
"heating.sensors.power.output.value" => "Sensor_Stromproduktion",
|
|
|
|
"heating.sensors.temperature.outside.status" => "Aussen_Status",
|
|
"heating.sensors.temperature.outside.statusWired" => "Aussen_StatusWired",
|
|
"heating.sensors.temperature.outside.statusWireless" =>
|
|
"Aussen_StatusWireless",
|
|
"heating.sensors.temperature.outside.unit" => "Aussentemperatur/Einheit",
|
|
"heating.sensors.temperature.outside.value" => "Aussentemperatur",
|
|
|
|
"heating.service.timeBased.serviceDue" => "Service_faellig",
|
|
"heating.service.timeBased.serviceIntervalMonths" =>
|
|
"Service_Intervall_Monate",
|
|
"heating.service.timeBased.activeMonthSinceLastService" =>
|
|
"Service_Monate_aktiv_seit_letzten_Service",
|
|
"heating.service.timeBased.lastService" => "Service_Letzter",
|
|
"heating.service.burnerBased.serviceDue" =>
|
|
"Service_fällig_brennerbasiert",
|
|
"heating.service.burnerBased.serviceIntervalBurnerHours" =>
|
|
"Service_Intervall_Betriebsstunden",
|
|
"heating.service.burnerBased.activeBurnerHoursSinceLastService" =>
|
|
"Service_Betriebsstunden_seit_letzten",
|
|
"heating.service.burnerBased.lastService" =>
|
|
"Service_Letzter_brennerbasiert",
|
|
|
|
"heating.solar.active" => "Solar_aktiv",
|
|
"heating.solar.pumps.circuit.status" => "Solar_Pumpe_Status",
|
|
"heating.solar.rechargeSuppression.status" =>
|
|
"Solar_Aufladeunterdrueckung_Status",
|
|
"heating.solar.sensors.power.status" => "Solar_Sensor_Power_Status",
|
|
"heating.solar.sensors.power.value" => "Solar_Sensor_Power",
|
|
"heating.solar.sensors.temperature.collector.status" =>
|
|
"Solar_Sensor_Temperatur_Kollektor_Status",
|
|
"heating.solar.sensors.temperature.collector.value" =>
|
|
"Solar_Sensor_Temperatur_Kollektor",
|
|
"heating.solar.sensors.temperature.dhw.status" =>
|
|
"Solar_Sensor_Temperatur_WW_Status",
|
|
"heating.solar.sensors.temperature.dhw.value" =>
|
|
"Solar_Sensor_Temperatur_WW",
|
|
"heating.solar.statistics.hours" => "Solar_Sensor_Statistik_Stunden",
|
|
|
|
"heating.solar.power.cumulativeProduced.value" =>
|
|
"Solarproduktion_Gesamtertrag",
|
|
"heating.solar.power.production.month" => "Solarproduktion/Monat",
|
|
"heating.solar.power.production.day" => "Solarproduktion/Tag",
|
|
"heating.solar.power.production.unit" => "Solarproduktion/Einheit",
|
|
"heating.solar.power.production.week" => "Solarproduktion/Woche",
|
|
"heating.solar.power.production.year" => "Solarproduktion/Jahr"
|
|
};
|
|
|
|
sub vitoconnect_Initialize {
|
|
my ($hash) = @_;
|
|
$hash->{DefFn} = \&vitoconnect_Define;
|
|
$hash->{UndefFn} = \&vitoconnect_Undef;
|
|
$hash->{SetFn} = \&vitoconnect_Set;
|
|
$hash->{GetFn} = \&vitoconnect_Get;
|
|
$hash->{AttrFn} = \&vitoconnect_Attr;
|
|
$hash->{ReadFn} = \&vitoconnect_Read;
|
|
$hash->{AttrList} =
|
|
"disable:0,1 "
|
|
. "mapping:textField-long "
|
|
. "model:Vitodens_200-W_(B2HB),Vitodens_200-W_(B2KB),"
|
|
. "Vitotronic_200_(HO1),Vitotronic_200_(HO1A),Vitotronic_200_(HO1B),Vitotronic_200_(HO1D),"
|
|
. "Vitotronic_200_(HO2B),"
|
|
. "Vitotronic_200_RF_(HO1C),Vitotronic_200_RF_(HO1E),"
|
|
. "Vitotronic_200_(KO1B),Vitotronic_200_(KO2B),Vitotronic_200_(KW6),Vitotronic_200_(KW6A),"
|
|
. "Vitotronic_200_(KW6B),Vitotronic_200_(KW1),Vitotronic_200_(KW2),Vitotronic_200_(KW4),"
|
|
. "Vitotronic_200_(KW5),"
|
|
. "Vitotronic_300_(KW3),Vitotronic_200_(WO1A),Vitotronic_200_(WO1B),Vitotronic_200_(WO1C),"
|
|
. "Vitoligno_300-C,Vitoligno_200-S,Vitoligno_300-P_mit_Vitotronic_200_(FO1),Vitoligno_250-S,"
|
|
. "Vitoligno_300-S "
|
|
. "vitoconnect_raw_readings:0,1 "
|
|
. "vitoconnect_gw_readings:0,1 "
|
|
. "vitoconnect_actions_active:0,1 "
|
|
. "vitoconnect_device:0,1 "
|
|
. "vitoconnect_timeout:selectnumbers,10,1.0,30,0,lin "
|
|
. $readingFnAttributes;
|
|
return;
|
|
}
|
|
|
|
sub vitoconnect_Define {
|
|
my ( $hash, $def ) = @_;
|
|
my $name = $hash->{NAME};
|
|
my @param = split( '[ \t]+', $def );
|
|
|
|
if ( int(@param) < 5 ) {
|
|
return "too few parameters: "
|
|
. "define <name> vitoconnect <user> <passwd> <intervall>";
|
|
}
|
|
|
|
$hash->{user} = $param[2];
|
|
$hash->{intervall} = $param[4];
|
|
$hash->{counter} = 0;
|
|
$hash->{timeout} = 15;
|
|
$hash->{".access_token"} = "";
|
|
$hash->{".installation"} = "";
|
|
$hash->{".gw"} = "";
|
|
$hash->{"Redirect_URI"} = $callback_uri;
|
|
|
|
my $isiwebpasswd = vitoconnect_ReadKeyValue( $hash, "passwd" );
|
|
if ( $isiwebpasswd eq "" ) {
|
|
my $err = vitoconnect_StoreKeyValue( $hash, "passwd", $param[3] );
|
|
return $err if ($err);
|
|
}
|
|
else {
|
|
Log3 $name, 3, "$name - Passwort war bereits gespeichert";
|
|
}
|
|
$hash->{apiKey} = vitoconnect_ReadKeyValue( $hash, "apiKey" );
|
|
InternalTimer( gettimeofday() + 10, "vitoconnect_GetUpdate", $hash );
|
|
return;
|
|
}
|
|
|
|
sub vitoconnect_Undef {
|
|
my ( $hash, $arg ) = @_;
|
|
RemoveInternalTimer($hash);
|
|
return;
|
|
}
|
|
|
|
sub vitoconnect_Get {
|
|
my ( $hash, $name, $opt, @args ) = @_;
|
|
return "get $name needs at least one argument" unless ( defined($opt) );
|
|
return;
|
|
}
|
|
|
|
sub vitoconnect_Set {
|
|
my ( $hash, $name, $opt, @args ) = @_;
|
|
return "set $name needs at least one argument" unless ( defined($opt) );
|
|
if ( $opt eq "update" ) {
|
|
RemoveInternalTimer($hash);
|
|
vitoconnect_GetUpdate($hash);
|
|
return;
|
|
}
|
|
elsif ( $opt eq "logResponseOnce" ) {
|
|
$hash->{".logResponseOnce"} = 1;
|
|
RemoveInternalTimer($hash);
|
|
vitoconnect_getCode($hash);
|
|
return;
|
|
}
|
|
elsif ( $opt eq "clearReadings" ) {
|
|
AnalyzeCommand( $hash, "deletereading $name .*" );
|
|
return;
|
|
}
|
|
elsif ( $opt eq "password" ) {
|
|
my $err = vitoconnect_StoreKeyValue( $hash, "passwd", $args[0] );
|
|
return $err if ($err);
|
|
vitoconnect_getCode($hash);
|
|
return;
|
|
}
|
|
elsif ( $opt eq "apiKey" ) {
|
|
$hash->{apiKey} = $args[0];
|
|
my $err = vitoconnect_StoreKeyValue( $hash, "apiKey", $args[0] );
|
|
RemoveInternalTimer($hash);
|
|
vitoconnect_getCode($hash);
|
|
return;
|
|
}
|
|
elsif ( $opt eq "HK1-Heizkurve-Niveau" ) {
|
|
my $slope = ReadingsVal( $name, "HK1-Heizkurve-Steigung", "" );
|
|
vitoconnect_action(
|
|
$hash,
|
|
"heating.circuits.0.heating.curve/commands/setCurve",
|
|
"{\"shift\":$args[0],\"slope\":$slope}",
|
|
$name, $opt, @args
|
|
);
|
|
return;
|
|
}
|
|
elsif ( $opt eq "HK2-Heizkurve-Niveau" ) {
|
|
my $slope = ReadingsVal( $name, "HK2-Heizkurve-Steigung", "" );
|
|
vitoconnect_action(
|
|
$hash,
|
|
"heating.circuits.1.heating.curve/commands/setCurve",
|
|
"{\"shift\":$args[0],\"slope\":$slope}",
|
|
$name, $opt, @args
|
|
);
|
|
return;
|
|
}
|
|
elsif ( $opt eq "HK3-Heizkurve-Niveau" ) {
|
|
my $slope = ReadingsVal( $name, "HK3-Heizkurve-Steigung", "" );
|
|
vitoconnect_action(
|
|
$hash,
|
|
"heating.circuits.2.heating.curve/commands/setCurve",
|
|
"{\"shift\":$args[0],\"slope\":$slope}",
|
|
$name, $opt, @args
|
|
);
|
|
return;
|
|
}
|
|
elsif ( $opt eq "HK1-Heizkurve-Steigung" ) {
|
|
my $shift = ReadingsVal( $name, "HK1-Heizkurve-Niveau", "" );
|
|
vitoconnect_action(
|
|
$hash,
|
|
"heating.circuits.0.heating.curve/commands/setCurve",
|
|
"{\"shift\":$shift,\"slope\":$args[0]}",
|
|
$name, $opt, @args
|
|
);
|
|
return;
|
|
}
|
|
elsif ( $opt eq "HK2-Heizkurve-Steigung" ) {
|
|
my $shift = ReadingsVal( $name, "HK2-Heizkurve-Niveau", "" );
|
|
vitoconnect_action(
|
|
$hash,
|
|
"heating.circuits.1.heating.curve/commands/setCurve",
|
|
"{\"shift\":$shift,\"slope\":$args[0]}",
|
|
$name, $opt, @args
|
|
);
|
|
return;
|
|
}
|
|
elsif ( $opt eq "HK3-Heizkurve-Steigung" ) {
|
|
my $shift = ReadingsVal( $name, "HK3-Heizkurve-Niveau", "" );
|
|
vitoconnect_action(
|
|
$hash,
|
|
"heating.circuits.2.heating.curve/commands/setCurve",
|
|
"{\"shift\":$shift,\"slope\":$args[0]}",
|
|
$name, $opt, @args
|
|
);
|
|
return;
|
|
}
|
|
elsif ( $opt eq "HK1-Urlaub_Start" ) {
|
|
my $end = ReadingsVal( $name, "HK1-Urlaub_Ende", "" );
|
|
if ( $end eq "" ) {
|
|
my $t = Time::Piece->strptime( $args[0], "%Y-%m-%d" );
|
|
$t += ONE_DAY;
|
|
$end = $t->strftime("%Y-%m-%d");
|
|
}
|
|
vitoconnect_action(
|
|
$hash,
|
|
"heating.circuits.0.operating.programs.holiday/commands/schedule",
|
|
"{\"start\":\"$args[0]\",\"end\":\"$end\"}",
|
|
$name,
|
|
$opt,
|
|
@args
|
|
);
|
|
return;
|
|
}
|
|
elsif ( $opt eq "HK2-Urlaub_Start" ) {
|
|
my $end = ReadingsVal( $name, "HK2-Urlaub_Ende", "" );
|
|
if ( $end eq "" ) {
|
|
my $t = Time::Piece->strptime( $args[0], "%Y-%m-%d" );
|
|
$t += ONE_DAY;
|
|
$end = $t->strftime("%Y-%m-%d");
|
|
}
|
|
vitoconnect_action(
|
|
$hash,
|
|
"heating.circuits.1.operating.programs.holiday/commands/schedule",
|
|
"{\"start\":\"$args[0]\",\"end\":\"$end\"}",
|
|
$name,
|
|
$opt,
|
|
@args
|
|
);
|
|
return;
|
|
}
|
|
elsif ( $opt eq "HK3-Urlaub_Start" ) {
|
|
my $end = ReadingsVal( $name, "HK3-Urlaub_Ende", "" );
|
|
if ( $end eq "" ) {
|
|
my $t = Time::Piece->strptime( $args[0], "%Y-%m-%d" );
|
|
$t += ONE_DAY;
|
|
$end = $t->strftime("%Y-%m-%d");
|
|
}
|
|
vitoconnect_action(
|
|
$hash,
|
|
"heating.circuits.2.operating.programs.holiday/commands/schedule",
|
|
"{\"start\":\"$args[0]\",\"end\":\"$end\"}",
|
|
$name,
|
|
$opt,
|
|
@args
|
|
);
|
|
return;
|
|
}
|
|
elsif ( $opt eq "HK1-Urlaub_Ende" ) {
|
|
my $start = ReadingsVal( $name, "HK1-Urlaub_Start", "" );
|
|
vitoconnect_action(
|
|
$hash,
|
|
"heating.circuits.0.operating.programs.holiday/commands/schedule",
|
|
"{\"start\":\"$start\",\"end\":\"$args[0]\"}",
|
|
$name,
|
|
$opt,
|
|
@args
|
|
);
|
|
return;
|
|
}
|
|
elsif ( $opt eq "HK2-Urlaub_Ende" ) {
|
|
my $start = ReadingsVal( $name, "HK2-Urlaub_Start", "" );
|
|
vitoconnect_action(
|
|
$hash,
|
|
"heating.circuits.1.operating.programs.holiday/commands/schedule",
|
|
"{\"start\":\"$start\",\"end\":\"$args[0]\"}",
|
|
$name,
|
|
$opt,
|
|
@args
|
|
);
|
|
return;
|
|
}
|
|
elsif ( $opt eq "HK3-Urlaub_Ende" ) {
|
|
my $start = ReadingsVal( $name, "HK3-Urlaub_Start", "" );
|
|
vitoconnect_action(
|
|
$hash,
|
|
"heating.circuits.2.operating.programs.holiday/commands/schedule",
|
|
"{\"start\":\"$start\",\"end\":\"$args[0]\"}",
|
|
$name,
|
|
$opt,
|
|
@args
|
|
);
|
|
return;
|
|
}
|
|
elsif ( $opt eq "HK1-Urlaub_unschedule" ) {
|
|
vitoconnect_action(
|
|
$hash,
|
|
"heating.circuits.0.operating.programs.holiday/commands/unschedule",
|
|
"{}",
|
|
$name,
|
|
$opt,
|
|
@args
|
|
);
|
|
return;
|
|
}
|
|
elsif ( $opt eq "HK2-Urlaub_unschedule" ) {
|
|
vitoconnect_action(
|
|
$hash,
|
|
"heating.circuits.1.operating.programs.holiday/commands/unschedule",
|
|
"{}",
|
|
$name,
|
|
$opt,
|
|
@args
|
|
);
|
|
return;
|
|
}
|
|
elsif ( $opt eq "HK3-Urlaub_unschedule" ) {
|
|
vitoconnect_action(
|
|
$hash,
|
|
"heating.circuits.2.operating.programs.holiday/commands/unschedule",
|
|
"{}",
|
|
$name,
|
|
$opt,
|
|
@args
|
|
);
|
|
return;
|
|
}
|
|
elsif ( $opt eq "HK1-Zeitsteuerung_Heizung" ) {
|
|
vitoconnect_action( $hash,
|
|
"heating.circuits.0.heating.schedule/commands/setSchedule",
|
|
"{\"newSchedule\":@args}", $name, $opt, @args );
|
|
return;
|
|
}
|
|
elsif ( $opt eq "HK2-Zeitsteuerung_Heizung" ) {
|
|
vitoconnect_action( $hash,
|
|
"heating.circuits.1.heating.schedule/commands/setSchedule",
|
|
"{\"newSchedule\":@args}", $name, $opt, @args );
|
|
return;
|
|
}
|
|
elsif ( $opt eq "HK3-Zeitsteuerung_Heizung" ) {
|
|
vitoconnect_action( $hash,
|
|
"heating.circuits.2.heating.schedule/commands/setSchedule",
|
|
"{\"newSchedule\":@args}", $name, $opt, @args );
|
|
return;
|
|
}
|
|
elsif ( $opt eq "HK1-Betriebsart" ) {
|
|
vitoconnect_action( $hash,
|
|
"heating.circuits.0.operating.modes.active/commands/setMode",
|
|
"{\"mode\":\"$args[0]\"}", $name, $opt, @args );
|
|
return;
|
|
}
|
|
elsif ( $opt eq "HK2-Betriebsart" ) {
|
|
vitoconnect_action( $hash,
|
|
"heating.circuits.1.operating.modes.active/commands/setMode",
|
|
"{\"mode\":\"$args[0]\"}", $name, $opt, @args );
|
|
return;
|
|
}
|
|
elsif ( $opt eq "HK3-Betriebsart" ) {
|
|
vitoconnect_action( $hash,
|
|
"heating.circuits.2.operating.modes.active/commands/setMode",
|
|
"{\"mode\":\"$args[0]\"}", $name, $opt, @args );
|
|
return;
|
|
}
|
|
elsif ( $opt eq "HK1-Solltemperatur_comfort_aktiv" ) {
|
|
vitoconnect_action( $hash,
|
|
"heating.circuits.0.operating.programs.comfort/commands/$args[0]",
|
|
"{}", $name, $opt, @args );
|
|
return;
|
|
}
|
|
elsif ( $opt eq "HK2-Solltemperatur_comfort_aktiv" ) {
|
|
vitoconnect_action( $hash,
|
|
"heating.circuits.1.operating.programs.comfort/commands/$args[0]",
|
|
"{}", $name, $opt, @args );
|
|
return;
|
|
}
|
|
elsif ( $opt eq "HK3-Solltemperatur_comfort_aktiv" ) {
|
|
vitoconnect_action( $hash,
|
|
"heating.circuits.2.operating.programs.comfort/commands/$args[0]",
|
|
"{}", $name, $opt, @args );
|
|
return;
|
|
}
|
|
elsif ( $opt eq "HK1-Solltemperatur_comfort" ) {
|
|
vitoconnect_action($hash,
|
|
"heating.circuits.0.operating.programs.comfort/commands/setTemperature",
|
|
"{\"targetTemperature\":$args[0]}",
|
|
$name,
|
|
$opt,
|
|
@args
|
|
);
|
|
return;
|
|
}
|
|
elsif ( $opt eq "HK2-Solltemperatur_comfort" ) {
|
|
vitoconnect_action($hash,
|
|
"heating.circuits.1.operating.programs.comfort/commands/setTemperature",
|
|
"{\"targetTemperature\":$args[0]}",
|
|
$name,
|
|
$opt,
|
|
@args
|
|
);
|
|
return;
|
|
}
|
|
elsif ( $opt eq "HK3-Solltemperatur_comfort" ) {
|
|
vitoconnect_action($hash,
|
|
"heating.circuits.2.operating.programs.comfort/commands/setTemperature",
|
|
"{\"targetTemperature\":$args[0]}",
|
|
$name,
|
|
$opt,
|
|
@args
|
|
);
|
|
return;
|
|
}
|
|
elsif ( $opt eq "HK1-Solltemperatur_eco_aktiv" ) {
|
|
vitoconnect_action( $hash,
|
|
"heating.circuits.0.operating.programs.eco/commands/$args[0]",
|
|
"{}", $name, $opt, @args );
|
|
return;
|
|
|
|
}
|
|
elsif ( $opt eq "HK2-Solltemperatur_eco_aktiv" ) {
|
|
vitoconnect_action( $hash,
|
|
"heating.circuits.1.operating.programs.eco/commands/$args[0]",
|
|
"{}", $name, $opt, @args );
|
|
return;
|
|
}
|
|
elsif ( $opt eq "HK3-Solltemperatur_eco_aktiv" ) {
|
|
vitoconnect_action( $hash,
|
|
"heating.circuits.2.operating.programs.eco/commands/$args[0]",
|
|
"{}", $name, $opt, @args );
|
|
return;
|
|
}
|
|
elsif ( $opt eq "HK1-Solltemperatur_normal" ) {
|
|
vitoconnect_action($hash,
|
|
"heating.circuits.0.operating.programs.normal/commands/setTemperature",
|
|
"{\"targetTemperature\":$args[0]}",
|
|
$name,
|
|
$opt,
|
|
@args
|
|
);
|
|
return;
|
|
}
|
|
elsif ( $opt eq "HK2-Solltemperatur_normal" ) {
|
|
vitoconnect_action($hash,
|
|
"heating.circuits.1.operating.programs.normal/commands/setTemperature",
|
|
"{\"targetTemperature\":$args[0]}",
|
|
$name,
|
|
$opt,
|
|
@args
|
|
);
|
|
return;
|
|
}
|
|
elsif ( $opt eq "HK3-Solltemperatur_normal" ) {
|
|
vitoconnect_action($hash,
|
|
"heating.circuits.2.operating.programs.normal/commands/setTemperature",
|
|
"{\"targetTemperature\":$args[0]}",
|
|
$name,
|
|
$opt,
|
|
@args
|
|
);
|
|
return;
|
|
}
|
|
elsif ( $opt eq "HK1-Solltemperatur_reduziert" ) {
|
|
vitoconnect_action($hash,
|
|
"heating.circuits.0.operating.programs.reduced/commands/setTemperature",
|
|
"{\"targetTemperature\":$args[0]}",
|
|
$name,
|
|
$opt,
|
|
@args
|
|
);
|
|
return;
|
|
}
|
|
elsif ( $opt eq "HK2-Solltemperatur_reduziert" ) {
|
|
vitoconnect_action($hash,
|
|
"heating.circuits.1.operating.programs.reduced/commands/setTemperature",
|
|
"{\"targetTemperature\":$args[0]}",
|
|
$name,
|
|
$opt,
|
|
@args
|
|
);
|
|
return;
|
|
}
|
|
elsif ( $opt eq "HK3-Solltemperatur_reduziert" ) {
|
|
vitoconnect_action($hash,
|
|
"heating.circuits.2.operating.programs.reduced/commands/setTemperature",
|
|
"{\"targetTemperature\":$args[0]}",
|
|
$name,
|
|
$opt,
|
|
@args
|
|
);
|
|
return;
|
|
}
|
|
elsif ( $opt eq "HK1-Name" ) {
|
|
vitoconnect_action( $hash, "heating.circuits.0/commands/setName",
|
|
"{\"name\":\"@args\"}", $name, $opt, @args );
|
|
return;
|
|
}
|
|
elsif ( $opt eq "HK2-Name" ) {
|
|
vitoconnect_action( $hash, "heating.circuits.1/commands/setName",
|
|
"{\"name\":\"@args\"}", $name, $opt, @args );
|
|
return;
|
|
}
|
|
elsif ( $opt eq "HK3-Name" ) {
|
|
vitoconnect_action( $hash, "heating.circuits.2/commands/setName",
|
|
"{\"name\":\"@args\"}", $name, $opt, @args );
|
|
return;
|
|
}
|
|
elsif ( $opt eq "WW-einmaliges_Aufladen" ) {
|
|
vitoconnect_action( $hash,
|
|
"heating.dhw.oneTimeCharge/commands/$args[0]",
|
|
"{}", $name, $opt, @args );
|
|
return;
|
|
}
|
|
elsif ( $opt eq "WW-Zirkulationspumpe_Zeitplan" ) {
|
|
vitoconnect_action( $hash,
|
|
"heating.dhw.pumps.circulation.schedule/commands/setSchedule",
|
|
"{\"newSchedule\":@args}", $name, $opt, @args );
|
|
return;
|
|
}
|
|
elsif ( $opt eq "WW-Zeitplan" ) {
|
|
vitoconnect_action( $hash, "heating.dhw.schedule/commands/setSchedule",
|
|
"{\"newSchedule\":@args}", $name, $opt, @args );
|
|
return;
|
|
}
|
|
elsif ( $opt eq "WW-Haupttemperatur" ) {
|
|
vitoconnect_action( $hash,
|
|
"heating.dhw.temperature.main/commands/setTargetTemperature",
|
|
"{\"temperature\":$args[0]}", $name, $opt, @args );
|
|
return;
|
|
}
|
|
elsif ( $opt eq "WW-Solltemperatur" ) {
|
|
vitoconnect_action( $hash,
|
|
"heating.dhw.temperature/commands/commands/setTargetTemperature",
|
|
"{\"temperature\":$args[0]}", $name, $opt, @args );
|
|
return;
|
|
}
|
|
elsif ( $opt eq "WW-Temperatur_2" ) {
|
|
vitoconnect_action( $hash,
|
|
"heating.dhw.temperature.temp2/commands/setTargetTemperature",
|
|
"{\"temperature\":$args[0]}", $name, $opt, @args );
|
|
return;
|
|
}
|
|
elsif ( $opt eq "Urlaub_Start" ) {
|
|
my $end = ReadingsVal( $name, "Urlaub_Ende", "" );
|
|
if ( $end eq "" ) {
|
|
my $t = Time::Piece->strptime( $args[0], "%Y-%m-%d" );
|
|
$t += ONE_DAY;
|
|
$end = $t->strftime("%Y-%m-%d");
|
|
}
|
|
vitoconnect_action(
|
|
$hash,
|
|
"heating.operating.programs.holiday/commands/schedule",
|
|
"{\"start\":\"$args[0]\",\"end\":\"$end\"}",
|
|
$name, $opt, @args
|
|
);
|
|
return;
|
|
}
|
|
elsif ( $opt eq "Urlaub_Ende" ) {
|
|
my $start = ReadingsVal( $name, "Urlaub_Start", "" );
|
|
vitoconnect_action(
|
|
$hash,
|
|
"heating.operating.programs.holiday/commands/schedule",
|
|
"{\"start\":\"$start\",\"end\":\"$args[0]\"}",
|
|
$name, $opt, @args
|
|
);
|
|
return;
|
|
}
|
|
elsif ( $opt eq "Urlaub_unschedule" ) {
|
|
vitoconnect_action( $hash,
|
|
"heating.operating.programs.holiday/commands/unschedule",
|
|
"{}", $name, $opt, @args );
|
|
return;
|
|
}
|
|
|
|
my $val =
|
|
"unknown value $opt, choose one of update:noArg clearReadings:noArg "
|
|
. "password apiKey logResponseOnce:noArg "
|
|
. "WW-einmaliges_Aufladen:activate,deactivate "
|
|
. "WW-Zirkulationspumpe_Zeitplan:textField-long "
|
|
. "WW-Zeitplan:textField-long "
|
|
. "WW-Haupttemperatur:slider,10,1,60 "
|
|
. "WW-Solltemperatur:slider,10,1,60 "
|
|
. "WW-Temperatur_2:slider,10,1,60 "
|
|
. "Urlaub_Start "
|
|
. "Urlaub_Ende "
|
|
. "Urlaub_unschedule:noArg ";
|
|
|
|
if ( ReadingsVal( $name, "HK1-aktiv", "0" ) eq "1" ) {
|
|
$val .=
|
|
"HK1-Heizkurve-Niveau:slider,-13,1,40 "
|
|
. "HK1-Heizkurve-Steigung:slider,0.2,0.1,3.5,1 "
|
|
. "HK1-Zeitsteuerung_Heizung:textField-long "
|
|
. "HK1-Urlaub_Start "
|
|
. "HK1-Urlaub_Ende "
|
|
. "HK1-Urlaub_unschedule:noArg "
|
|
. "HK1-Betriebsart:active,standby,heating,dhw,dhwAndHeating,forcedReduced,forcedNormal "
|
|
. "HK1-Solltemperatur_comfort_aktiv:activate,deactivate "
|
|
. "HK1-Solltemperatur_comfort:slider,4,1,37 "
|
|
. "HK1-Solltemperatur_eco_aktiv:activate,deactivate "
|
|
. "HK1-Solltemperatur_normal:slider,3,1,37 "
|
|
. "HK1-Solltemperatur_reduziert:slider,3,1,37 "
|
|
. "HK1-Name ";
|
|
}
|
|
if ( ReadingsVal( $name, "HK2-aktiv", "0" ) eq "1" ) {
|
|
$val .=
|
|
"HK2-Heizkurve-Niveau:slider,-13,1,40 "
|
|
. "HK2-Heizkurve-Steigung:slider,0.2,0.1,3.5,1 "
|
|
. "HK2-Zeitsteuerung_Heizung:textField-long "
|
|
. "HK2-Urlaub_Start "
|
|
. "HK2-Urlaub_Ende "
|
|
. "HK2-Urlaub_unschedule:noArg "
|
|
. "HK2-Betriebsart:active,standby,heating,dhw,dhwAndHeating,forcedReduced,forcedNormal "
|
|
. "HK2-Solltemperatur_comfort_aktiv:activate,deactivate "
|
|
. "HK2-Solltemperatur_comfort:slider,4,1,37 "
|
|
. "HK2-Solltemperatur_eco_aktiv:activate,deactivate "
|
|
. "HK2-Solltemperatur_normal:slider,3,1,37 "
|
|
. "HK2-Solltemperatur_reduziert:slider,3,1,37 "
|
|
. "HK2-Name ";
|
|
}
|
|
if ( ReadingsVal( $name, "HK3-aktiv", "0" ) eq "1" ) {
|
|
$val .=
|
|
"HK3-Heizkurve-Niveau:slider,-13,1,40 "
|
|
. "HK3-Heizkurve-Steigung:slider,0.2,0.1,3.5,1 "
|
|
. "HK3-Zeitsteuerung_Heizung:textField-long "
|
|
. "HK3-Urlaub_Start "
|
|
. "HK3-Urlaub_Ende "
|
|
. "HK3-Urlaub_unschedule:noArg "
|
|
. "HK3-Betriebsart:active,standby,heating,dhw,dhwAndHeating,forcedReduced,forcedNormal "
|
|
. "HK3-Solltemperatur_comfort_aktiv:activate,deactivate "
|
|
. "HK3-Solltemperatur_comfort:slider,4,1,37 "
|
|
. "HK3-Solltemperatur_eco_aktiv:activate,deactivate "
|
|
. "HK3-Solltemperatur_normal:slider,3,1,37 "
|
|
. "HK3-Solltemperatur_reduziert:slider,3,1,37 "
|
|
. "HK3-Name ";
|
|
}
|
|
return $val;
|
|
}
|
|
|
|
sub vitoconnect_Attr {
|
|
my ( $cmd, $name, $attr_name, $attr_value ) = @_;
|
|
if ( $cmd eq "set" ) {
|
|
if ( $attr_name eq "vitoconnect_raw_readings" ) {
|
|
if ( $attr_value !~ /^0|1$/ ) {
|
|
my $err =
|
|
"Invalid argument $attr_value to $attr_name. Must be 0 or 1.";
|
|
Log 1, "$name - " . $err;
|
|
return $err;
|
|
}
|
|
}
|
|
elsif ( $attr_name eq "vitoconnect_gw_readings" ) {
|
|
if ( $attr_value !~ /^0|1$/ ) {
|
|
my $err =
|
|
"Invalid argument $attr_value to $attr_name. Must be 0 or 1.";
|
|
Log 1, "$name - " . $err;
|
|
return $err;
|
|
}
|
|
}
|
|
elsif ( $attr_name eq "vitoconnect_actions_active" ) {
|
|
if ( $attr_value !~ /^0|1$/ ) {
|
|
my $err =
|
|
"Invalid argument $attr_value to $attr_name. Must be 0 or 1.";
|
|
Log 1, "$name - " . $err;
|
|
return $err;
|
|
}
|
|
}
|
|
elsif ( $attr_name eq "mapping" ) {
|
|
|
|
# $RequestList2 = "$attr_value";
|
|
}
|
|
elsif ( $attr_name eq "disable" ) {
|
|
}
|
|
elsif ( $attr_name eq "verbose" ) {
|
|
}
|
|
else {
|
|
# return "Unknown attr $attr_name";
|
|
}
|
|
}
|
|
return;
|
|
}
|
|
|
|
# Subs
|
|
sub vitoconnect_GetUpdate {
|
|
my ($hash) = @_;
|
|
my $name = $hash->{NAME};
|
|
Log3 $name, 4, "$name - GetUpdate called ...";
|
|
if ( IsDisabled($name) ) {
|
|
Log3 $name, 4, "$name - device disabled";
|
|
InternalTimer( gettimeofday() + $hash->{intervall},
|
|
"vitoconnect_GetUpdate", $hash );
|
|
}
|
|
else {
|
|
vitoconnect_getResource($hash);
|
|
}
|
|
return;
|
|
}
|
|
|
|
sub vitoconnect_getCode {
|
|
my ($hash) = @_;
|
|
my $name = $hash->{NAME};
|
|
my $isiwebpasswd = vitoconnect_ReadKeyValue( $hash, "passwd" );
|
|
my $client_id = $hash->{apiKey};
|
|
if ( !defined($client_id) ) {
|
|
Log3 $name, 1, "$name - set apiKey first";
|
|
readingsSingleUpdate( $hash, "state", "Set apiKey to continue", 1 );
|
|
return;
|
|
}
|
|
my $authorizeURL = 'https://iam.viessmann.com/idp/v2/authorize';
|
|
|
|
my $param = {
|
|
url => "$authorizeURL?client_id=$client_id"
|
|
. "&redirect_uri=$callback_uri&"
|
|
. "code_challenge=2e21faa1-db2c-4d0b-a10f-575fd372bc8c-575fd372bc8c&"
|
|
. "&scope=IoT%20User%20offline_access"
|
|
. "&response_type=code",
|
|
hash => $hash,
|
|
header => "Content-Type: application/x-www-form-urlencoded",
|
|
ignoreredirects => 1,
|
|
user => $hash->{user},
|
|
pwd => $isiwebpasswd,
|
|
sslargs => { SSL_verify_mode => 0 },
|
|
timeout => $hash->{timeout},
|
|
method => "POST",
|
|
callback => \&vitoconnect_getCodeCallback
|
|
};
|
|
|
|
#Log3 $name, 4, "$name - user=$param->{user} passwd=$param->{pwd}";
|
|
#Log3 $name, 5, Dumper($hash);
|
|
HttpUtils_NonblockingGet($param);
|
|
return;
|
|
}
|
|
|
|
sub vitoconnect_getCodeCallback {
|
|
my ( $param, $err, $response_body ) = @_;
|
|
my $hash = $param->{hash};
|
|
my $name = $hash->{NAME};
|
|
|
|
if ( $err eq "" ) {
|
|
Log3 $name, 4, "$name - getCodeCallback went ok";
|
|
Log3 $name, 5, "$name - Received response: $response_body";
|
|
$response_body =~ /code=(.*)"/;
|
|
$hash->{".code"} = $1;
|
|
Log3 $name, 4, "$name - code: " . $hash->{".code"};
|
|
if ( $hash->{".code"} && $hash->{".code"} ne "4" ) {
|
|
$hash->{login} = "ok";
|
|
}
|
|
else {
|
|
$hash->{login} = "failure";
|
|
}
|
|
}
|
|
else {
|
|
Log3 $name, 1, "$name - An error occured: $err";
|
|
$hash->{login} = "failure";
|
|
}
|
|
if ( $hash->{login} eq "ok" ) {
|
|
readingsSingleUpdate( $hash, "state", "login ok", 1 );
|
|
vitoconnect_getAccessToken($hash);
|
|
}
|
|
else {
|
|
readingsSingleUpdate( $hash, "state",
|
|
"Login failure. Check password and apiKey", 1 );
|
|
Log3 $name, 1, "$name - Login failure. Check password and apiKey";
|
|
}
|
|
return;
|
|
}
|
|
|
|
sub vitoconnect_getAccessToken {
|
|
my ($hash) = @_;
|
|
my $name = $hash->{NAME};
|
|
my $client_id = $hash->{apiKey};
|
|
my $param = {
|
|
url => "https://iam.viessmann.com/idp/v2/token",
|
|
hash => $hash,
|
|
header => "Content-Type: application/x-www-form-urlencoded",
|
|
data => "grant_type=authorization_code"
|
|
. "&code_verifier="
|
|
. $client_secret
|
|
. "&client_id=$client_id"
|
|
. "&redirect_uri=$callback_uri"
|
|
. "&code="
|
|
. $hash->{".code"},
|
|
sslargs => { SSL_verify_mode => 0 },
|
|
method => "POST",
|
|
timeout => $hash->{timeout},
|
|
callback => \&vitoconnect_getAccessTokenCallback
|
|
};
|
|
|
|
#Log3 $name, 1, "$name - " . $param->{"data"};
|
|
HttpUtils_NonblockingGet($param);
|
|
return;
|
|
}
|
|
|
|
sub vitoconnect_getAccessTokenCallback {
|
|
my ( $param, $err, $response_body ) = @_;
|
|
my $hash = $param->{hash};
|
|
my $name = $hash->{NAME};
|
|
|
|
if ( $err eq "" ) {
|
|
Log3 $name, 4, "$name - getAccessTokenCallback went ok";
|
|
Log3 $name, 5, "$name - Received response: $response_body\n";
|
|
my $decode_json = eval { decode_json($response_body) };
|
|
if ($@) {
|
|
Log3 $name, 1, "$name - JSON error while request: $@";
|
|
InternalTimer( gettimeofday() + $hash->{intervall},
|
|
"vitoconnect_GetUpdate", $hash );
|
|
return;
|
|
}
|
|
my $access_token = $decode_json->{"access_token"};
|
|
if ( $access_token ne "" ) {
|
|
$hash->{".access_token"} = $access_token;
|
|
$hash->{"refresh_token"} = $decode_json->{"refresh_token"};
|
|
|
|
Log3 $name, 4,
|
|
"$name - Access Token: " . substr( $access_token, 0, 20 ) . "...";
|
|
vitoconnect_getGw($hash);
|
|
}
|
|
else {
|
|
Log3 $name, 1, "$name - Access Token: nicht definiert";
|
|
Log3 $name, 5, "$name - Received response: $response_body\n";
|
|
InternalTimer( gettimeofday() + $hash->{intervall},
|
|
"vitoconnect_GetUpdate", $hash );
|
|
}
|
|
}
|
|
else {
|
|
Log3 $name, 1, "$name - getAccessToken: An error occured: $err";
|
|
InternalTimer( gettimeofday() + $hash->{intervall},
|
|
"vitoconnect_GetUpdate", $hash );
|
|
}
|
|
return;
|
|
}
|
|
|
|
sub vitoconnect_getRefresh {
|
|
my ($hash) = @_;
|
|
my $name = $hash->{NAME};
|
|
my $client_id = $hash->{apiKey};
|
|
my $param = {
|
|
url => "https://iam.viessmann.com/idp/v2/token",
|
|
hash => $hash,
|
|
header => "Content-Type: application/x-www-form-urlencoded",
|
|
data => "grant_type=refresh_token"
|
|
. "&client_id=$client_id"
|
|
. "&refresh_token="
|
|
. $hash->{"refresh_token"},
|
|
sslargs => { SSL_verify_mode => 0 },
|
|
method => "POST",
|
|
timeout => $hash->{timeout},
|
|
callback => \&vitoconnect_getRefreshCallback
|
|
};
|
|
|
|
#Log3 $name, 1, "$name - " . $param->{"data"};
|
|
HttpUtils_NonblockingGet($param);
|
|
return;
|
|
}
|
|
|
|
sub vitoconnect_getRefreshCallback {
|
|
my ( $param, $err, $response_body ) = @_;
|
|
my $hash = $param->{hash};
|
|
my $name = $hash->{NAME};
|
|
|
|
if ( $err eq "" ) {
|
|
Log3 $name, 4, "$name - getRefreshCallback went ok";
|
|
Log3 $name, 5, "$name - Received response: $response_body\n";
|
|
my $decode_json = eval { decode_json($response_body) };
|
|
if ($@) {
|
|
Log3 $name, 1, "$name - JSON error while request: $@";
|
|
InternalTimer( gettimeofday() + $hash->{intervall},
|
|
"vitoconnect_GetUpdate", $hash );
|
|
return;
|
|
}
|
|
my $access_token = $decode_json->{"access_token"};
|
|
if ( $access_token ne "" ) {
|
|
$hash->{".access_token"} = $access_token;
|
|
|
|
#$hash->{"refresh_token"} = $decode_json->{"refresh_token"};
|
|
|
|
Log3 $name, 4,
|
|
"$name - Access Token: " . substr( $access_token, 0, 20 ) . "...";
|
|
vitoconnect_getGw($hash);
|
|
}
|
|
else {
|
|
Log3 $name, 1, "$name - Access Token: nicht definiert";
|
|
Log3 $name, 5, "$name - Received response: $response_body\n";
|
|
InternalTimer( gettimeofday() + $hash->{intervall},
|
|
"vitoconnect_GetUpdate", $hash ); # zurück zu getCode?
|
|
}
|
|
}
|
|
else {
|
|
Log3 $name, 1, "$name - getRefresh: An error occured: $err";
|
|
InternalTimer( gettimeofday() + $hash->{intervall},
|
|
"vitoconnect_GetUpdate", $hash );
|
|
}
|
|
return;
|
|
}
|
|
|
|
sub vitoconnect_getGw {
|
|
my ($hash) = @_;
|
|
my $name = $hash->{NAME};
|
|
my $access_token = $hash->{".access_token"};
|
|
my $param = {
|
|
url => $apiURL . "gateways",
|
|
hash => $hash,
|
|
header => "Authorization: Bearer $access_token",
|
|
timeout => $hash->{timeout},
|
|
sslargs => { SSL_verify_mode => 0 },
|
|
callback => \&vitoconnect_getGwCallback
|
|
};
|
|
HttpUtils_NonblockingGet($param);
|
|
return;
|
|
}
|
|
|
|
sub vitoconnect_getGwCallback {
|
|
my ( $param, $err, $response_body ) = @_;
|
|
my $hash = $param->{hash};
|
|
my $name = $hash->{NAME};
|
|
|
|
if ( $err eq "" ) {
|
|
Log3 $name, 4, "$name - getGwCallback went ok";
|
|
Log3 $name, 5, "$name - Received response: $response_body\n";
|
|
my $items = eval { decode_json($response_body) };
|
|
if ($@) {
|
|
readingsSingleUpdate( $hash, "state",
|
|
"JSON error while request: $@", 1 );
|
|
Log3 $name, 1, "$name - JSON error while request: $@";
|
|
InternalTimer( gettimeofday() + $hash->{intervall},
|
|
"vitoconnect_GetUpdate", $hash );
|
|
return;
|
|
}
|
|
if ( $hash->{".logResponseOnce"} ) {
|
|
my $dir = path( AttrVal( "global", "logdir", "log" ) );
|
|
my $file = $dir->child("gw.json");
|
|
my $file_handle = $file->openw_utf8();
|
|
$file_handle->print( Dumper($items) );
|
|
}
|
|
$hash->{".gw"} = $items->{data}[0]->{serial};
|
|
readingsSingleUpdate( $hash, "gw", $response_body, 1 );
|
|
vitoconnect_getInstallation($hash);
|
|
}
|
|
else {
|
|
Log3 $name, 1, "$name - An error occured: $err";
|
|
InternalTimer( gettimeofday() + $hash->{intervall},
|
|
"vitoconnect_GetUpdate", $hash );
|
|
}
|
|
return;
|
|
}
|
|
|
|
sub vitoconnect_getInstallation {
|
|
my ($hash) = @_;
|
|
my $name = $hash->{NAME};
|
|
my $access_token = $hash->{".access_token"};
|
|
my $param = {
|
|
url => $apiURL . "installations",
|
|
hash => $hash,
|
|
header => "Authorization: Bearer $access_token",
|
|
timeout => $hash->{timeout},
|
|
sslargs => { SSL_verify_mode => 0 },
|
|
callback => \&vitoconnect_getInstallationCallback
|
|
};
|
|
HttpUtils_NonblockingGet($param);
|
|
return;
|
|
}
|
|
|
|
sub vitoconnect_getInstallationCallback {
|
|
my ( $param, $err, $response_body ) = @_;
|
|
my $hash = $param->{hash};
|
|
my $name = $hash->{NAME};
|
|
|
|
if ( $err eq "" ) {
|
|
Log3 $name, 4, "$name - getInstallationCallback went ok";
|
|
Log3 $name, 5, "$name - Received response: $response_body";
|
|
my $items = eval { decode_json($response_body) };
|
|
if ($@) {
|
|
readingsSingleUpdate( $hash, "state",
|
|
"JSON error while request: $@", 1 );
|
|
Log3 $name, 1, "$name - JSON error while request: $@";
|
|
InternalTimer( gettimeofday() + $hash->{intervall},
|
|
"vitoconnect_GetUpdate", $hash );
|
|
return;
|
|
}
|
|
if ( $hash->{".logResponseOnce"} ) {
|
|
my $dir = path( AttrVal( "global", "logdir", "log" ) );
|
|
my $file = $dir->child("installation.json");
|
|
my $file_handle = $file->openw_utf8();
|
|
$file_handle->print( Dumper($items) );
|
|
}
|
|
my $id = $items->{data}[0]->{id};
|
|
if ( $id == "" ) {
|
|
Log3 $name, 1, "$name - Something went wrong. Will retry";
|
|
InternalTimer( gettimeofday() + $hash->{intervall},
|
|
"vitoconnect_GetUpdate", $hash );
|
|
}
|
|
else {
|
|
$hash->{".installation"} = $items->{data}[0]->{id};
|
|
readingsSingleUpdate( $hash, "installation", $response_body, 1 );
|
|
vitoconnect_getDevice($hash);
|
|
}
|
|
}
|
|
else {
|
|
Log3 $name, 1, "$name - An error occured: $err";
|
|
InternalTimer( gettimeofday() + $hash->{intervall},
|
|
"vitoconnect_GetUpdate", $hash );
|
|
}
|
|
return;
|
|
}
|
|
|
|
sub vitoconnect_getDevice {
|
|
my ($hash) = @_;
|
|
my $name = $hash->{NAME};
|
|
my $access_token = $hash->{".access_token"};
|
|
my $installation = $hash->{".installation"};
|
|
my $gw = $hash->{".gw"};
|
|
my $param = {
|
|
url => $apiURL . "installations/$installation/gateways/$gw/devices",
|
|
hash => $hash,
|
|
header => "Authorization: Bearer $access_token",
|
|
timeout => $hash->{timeout},
|
|
sslargs => { SSL_verify_mode => 0 },
|
|
callback => \&vitoconnect_getDeviceCallback
|
|
};
|
|
HttpUtils_NonblockingGet($param);
|
|
return;
|
|
}
|
|
|
|
sub vitoconnect_getDeviceCallback {
|
|
my ( $param, $err, $response_body ) = @_;
|
|
my $hash = $param->{hash};
|
|
my $name = $hash->{NAME};
|
|
|
|
if ( $err eq "" ) {
|
|
Log3 $name, 4, "$name - getDeviceCallback went ok";
|
|
Log3 $name, 5, "$name - Received response: $response_body\n";
|
|
my $items = eval { decode_json($response_body) };
|
|
if ($@) {
|
|
readingsSingleUpdate( $hash, "state",
|
|
"JSON error while request: $@", 1 );
|
|
Log3 $name, 1, "$name - JSON error while request: $@";
|
|
InternalTimer( gettimeofday() + $hash->{intervall},
|
|
"vitoconnect_GetUpdate", $hash );
|
|
return;
|
|
}
|
|
if ( $hash->{".logResponseOnce"} ) {
|
|
my $dir = path( AttrVal( "global", "logdir", "log" ) );
|
|
my $file = $dir->child("device.json");
|
|
my $file_handle = $file->openw_utf8();
|
|
$file_handle->print( Dumper($items) );
|
|
}
|
|
readingsSingleUpdate( $hash, "device", $response_body, 1 );
|
|
vitoconnect_getFeatures($hash);
|
|
vitoconnect_getResource($hash);
|
|
}
|
|
else {
|
|
Log3 $name, 1, "$name - An error occured: $err";
|
|
InternalTimer( gettimeofday() + $hash->{intervall},
|
|
"vitoconnect_GetUpdate", $hash );
|
|
}
|
|
return;
|
|
}
|
|
|
|
sub vitoconnect_getFeatures {
|
|
my ($hash) = @_;
|
|
my $name = $hash->{NAME};
|
|
my $access_token = $hash->{".access_token"};
|
|
my $installation = $hash->{".installation"};
|
|
my $gw = $hash->{".gw"};
|
|
my $dev = AttrVal( $name, 'vitoconnect_device', 0 );
|
|
|
|
Log3 $name, 4, "$name - getFeatures went ok";
|
|
|
|
# Service Documents -ToDo
|
|
|
|
# Gateway features
|
|
my $param = {
|
|
url => $apiURL . "installations/$installation/gateways/$gw/features",
|
|
hash => $hash,
|
|
header => "Authorization: Bearer $access_token",
|
|
timeout => $hash->{timeout},
|
|
sslargs => { SSL_verify_mode => 0 },
|
|
};
|
|
( my $err, my $msg ) = HttpUtils_BlockingGet($param);
|
|
my $decode_json = eval { decode_json($msg) };
|
|
if ( $err ne "" || $decode_json->{statusCode} ne "" ) {
|
|
Log3 $name, 1,
|
|
"$name - Fehler während " . "Gateway features: $err :: $msg";
|
|
}
|
|
else {
|
|
readingsSingleUpdate( $hash, "gw_features", $msg, 1 );
|
|
}
|
|
|
|
# installation features
|
|
my $param = {
|
|
url => $apiURL . "installations/$installation/features",
|
|
hash => $hash,
|
|
header => "Authorization: Bearer $access_token",
|
|
timeout => $hash->{timeout},
|
|
sslargs => { SSL_verify_mode => 0 },
|
|
};
|
|
( my $err, my $msg ) = HttpUtils_BlockingGet($param);
|
|
my $decode_json = eval { decode_json($msg) };
|
|
if ( $err ne "" || $decode_json->{statusCode} ne "" ) {
|
|
Log3 $name, 1,
|
|
"$name - Fehler während " . "installation features: $err :: $msg";
|
|
}
|
|
else {
|
|
readingsSingleUpdate( $hash, "installation_features", $msg, 1 );
|
|
}
|
|
|
|
#Events
|
|
# my $param = {
|
|
# url => "https://api.viessmann.com/iot/v1/events-history/events",
|
|
# hash => $hash,
|
|
# header => "Authorization: Bearer $access_token",
|
|
# data => "gatewaySerial=$gw",
|
|
# method => "POST",
|
|
# timeout => $hash->{timeout} ,
|
|
# sslargs => { SSL_verify_mode => 0 },
|
|
# };
|
|
# ( my $err, my $msg ) = HttpUtils_BlockingGet($param);
|
|
# my $decode_json = eval { decode_json($msg) };
|
|
# if ( $err ne "" || $decode_json->{statusCode} ne "" ) {
|
|
# Log3 $name, 1, "$name - Fehler während "
|
|
# . "events: $err :: $msg";
|
|
# }
|
|
# else {
|
|
# readingsSingleUpdate ( $hash, "events", $msg, 1);
|
|
# }
|
|
|
|
return;
|
|
}
|
|
|
|
sub vitoconnect_getResource {
|
|
my ($hash) = @_;
|
|
my $name = $hash->{NAME};
|
|
my $access_token = $hash->{".access_token"};
|
|
my $installation = $hash->{".installation"};
|
|
my $gw = $hash->{".gw"};
|
|
my $dev = AttrVal( $name, 'vitoconnect_device', 0 );
|
|
|
|
Log3 $name, 4, "$name - enter getResource";
|
|
Log3 $name, 4,
|
|
"$name - access_token: " . substr( $access_token, 0, 20 ) . "...";
|
|
Log3 $name, 4, "$name - installation: $installation";
|
|
Log3 $name, 4, "$name - gw: $gw";
|
|
if ( $access_token eq "" || $installation eq "" || $gw eq "" ) {
|
|
vitoconnect_getCode($hash);
|
|
return;
|
|
}
|
|
my $param = {
|
|
url => $apiURL
|
|
. "installations/$installation/gateways/$gw/devices/$dev/features",
|
|
hash => $hash,
|
|
header => "Authorization: Bearer $access_token",
|
|
timeout => $hash->{timeout},
|
|
sslargs => { SSL_verify_mode => 0 },
|
|
callback => \&vitoconnect_getResourceCallback
|
|
};
|
|
HttpUtils_NonblockingGet($param);
|
|
return;
|
|
}
|
|
|
|
sub vitoconnect_getResourceCallback {
|
|
my ( $param, $err, $response_body ) = @_;
|
|
my $hash = $param->{hash};
|
|
my $name = $hash->{NAME};
|
|
|
|
if ( $err eq "" ) {
|
|
Log3 $name, 4, "$name - getResourceCallback went ok";
|
|
Log3 $name, 5, "$name - Received response: "
|
|
. substr( $response_body, 0, 100 ) . "...";
|
|
my $items = eval { decode_json($response_body) };
|
|
if ($@) {
|
|
readingsSingleUpdate( $hash, "state",
|
|
"JSON error while request: $@", 1 );
|
|
Log3 $name, 1, "$name - JSON error while request: $@";
|
|
InternalTimer( gettimeofday() + $hash->{intervall},
|
|
"vitoconnect_GetUpdate", $hash );
|
|
return;
|
|
}
|
|
|
|
if ( !$items->{statusCode} eq "" ) {
|
|
Log3 $name, 4,
|
|
"$name - statusCode: $items->{statusCode} "
|
|
. "errorType: $items->{errorType} "
|
|
. "message: $items->{message} "
|
|
. "error: $items->{error}";
|
|
readingsSingleUpdate(
|
|
$hash,
|
|
"state",
|
|
"statusCode: $items->{statusCode} "
|
|
. "errorType: $items->{errorType} "
|
|
. "message: $items->{message} "
|
|
. "error: $items->{error}",
|
|
1
|
|
);
|
|
if ( $items->{statusCode} eq "401" ) {
|
|
|
|
# EXPIRED TOKEN
|
|
vitoconnect_getRefresh($hash);
|
|
return;
|
|
}
|
|
elsif ( $items->{statusCode} eq "404" ) {
|
|
|
|
# DEVICE_NOT_FOUND
|
|
Log3 $name, 1, "$name - Device not found: Optolink prüfen!";
|
|
InternalTimer( gettimeofday() + $hash->{intervall},
|
|
"vitoconnect_GetUpdate", $hash );
|
|
return;
|
|
}
|
|
elsif ( $items->{statusCode} eq "429" ) {
|
|
|
|
# RATE_LIMIT_EXCEEDED
|
|
Log3 $name, 1,
|
|
"$name - Anzahl der möglichen API Calls in überschritten!";
|
|
InternalTimer( gettimeofday() + $hash->{intervall},
|
|
"vitoconnect_GetUpdate", $hash );
|
|
return;
|
|
}
|
|
elsif ( $items->{statusCode} eq "502" ) {
|
|
|
|
# DEVICE_COMMUNICATION_ERROR error: Bad Gateway
|
|
Log3 $name, 1, "$name - temporärer API Fehler";
|
|
InternalTimer( gettimeofday() + $hash->{intervall},
|
|
"vitoconnect_GetUpdate", $hash );
|
|
return;
|
|
}
|
|
else {
|
|
Log3 $name, 1, "$name - unbekannter Fehler: "
|
|
. "Bitte den Entwickler informieren!";
|
|
Log3 $name, 1,
|
|
"$name - statusCode: $items->{statusCode} "
|
|
. "errorType: $items->{errorType} "
|
|
. "message: $items->{message} "
|
|
. "error: $items->{error}";
|
|
InternalTimer( gettimeofday() + $hash->{intervall},
|
|
"vitoconnect_GetUpdate", $hash );
|
|
return;
|
|
}
|
|
}
|
|
|
|
if ( $hash->{".logResponseOnce"} ) {
|
|
my $dir = path( AttrVal( "global", "logdir", "log" ) );
|
|
my $file = $dir->child("resource.json");
|
|
my $file_handle = $file->openw_utf8();
|
|
$file_handle->print( Dumper($items) );
|
|
}
|
|
|
|
readingsBeginUpdate($hash);
|
|
foreach ( @{ $items->{data} } ) {
|
|
my $feature = $_;
|
|
my $properties = $feature->{properties};
|
|
foreach my $key ( keys %$properties ) {
|
|
my $Reading =
|
|
$RequestList->{ $feature->{feature} . "." . $key };
|
|
if ( !defined($Reading)
|
|
|| AttrVal( $name, 'vitoconnect_raw_readings', 0 ) eq "1" )
|
|
{
|
|
$Reading = $feature->{feature} . "." . $key;
|
|
}
|
|
my $Type = $properties->{$key}->{type};
|
|
my $Value = $properties->{$key}->{value};
|
|
if ( $Type eq "array" ) {
|
|
if ( defined($Value) ) {
|
|
if ( ref($Value) eq 'ARRAY' ) {
|
|
my $Array = ( join( ",", @$Value ) );
|
|
readingsBulkUpdate( $hash, $Reading, $Array );
|
|
Log3 $name, 5, "$name - $Reading $Array ($Type)";
|
|
}
|
|
else {
|
|
Log3 $name, 4,
|
|
"$name - Array Workaround for Property: $Reading";
|
|
}
|
|
}
|
|
}
|
|
elsif ( $Type eq "Schedule" ) {
|
|
my $Result = encode_json($Value);
|
|
readingsBulkUpdate( $hash, $Reading, $Result );
|
|
Log3 $name, 5, "$name - $Reading: $Result ($Type)";
|
|
}
|
|
else {
|
|
readingsBulkUpdate( $hash, $Reading, $Value );
|
|
Log3 $name, 5, "$name - $Reading: $Value ($Type)";
|
|
}
|
|
}
|
|
}
|
|
readingsBulkUpdate( $hash, "state", "last update: " . TimeNow() . "" );
|
|
readingsEndUpdate( $hash, 1 );
|
|
}
|
|
else {
|
|
Log3 $name, 1, "$name - An error occured: $err";
|
|
}
|
|
InternalTimer( gettimeofday() + $hash->{intervall},
|
|
"vitoconnect_GetUpdate", $hash );
|
|
return;
|
|
}
|
|
|
|
sub vitoconnect_action {
|
|
my ( $hash, $feature, $data, $name, $opt, @args ) = @_;
|
|
my $access_token = $hash->{".access_token"};
|
|
my $installation = $hash->{".installation"};
|
|
my $gw = $hash->{".gw"};
|
|
my $dev = AttrVal( $name, 'vitoconnect_device', 0 );
|
|
my $param = {
|
|
url => $apiURLBase
|
|
. "installations/$installation/gateways/$gw/"
|
|
. "devices/$dev/features/$feature",
|
|
hash => $hash,
|
|
header => "Authorization: Bearer $access_token\r\n"
|
|
. "Content-Type: application/json",
|
|
data => $data,
|
|
timeout => $hash->{timeout},
|
|
method => "POST",
|
|
sslargs => { SSL_verify_mode => 0 },
|
|
};
|
|
Log3 $name, 4, "$name - url=$param->{url}";
|
|
Log3 $name, 4, "$name - data=$param->{data}";
|
|
( my $err, my $msg ) = HttpUtils_BlockingGet($param);
|
|
my $decode_json = eval { decode_json($msg) };
|
|
|
|
if ( $err ne "" || $decode_json->{statusCode} ne "" ) {
|
|
Log3 $name, 1, "$name - set $name $opt @args: Fehler während der "
|
|
. "Befehlsausführung: $err :: $msg";
|
|
}
|
|
else { Log3 $name, 3, "$name - set $name $opt @args"; }
|
|
return;
|
|
}
|
|
|
|
sub vitoconnect_StoreKeyValue {
|
|
###################################################
|
|
# checks and stores obfuscated keys like passwords
|
|
# based on / copied from FRITZBOX_storePassword
|
|
my ( $hash, $kName, $value ) = @_;
|
|
my $index = $hash->{TYPE} . "_" . $hash->{NAME} . "_" . $kName;
|
|
my $key = getUniqueId() . $index;
|
|
my $enc = "";
|
|
|
|
if ( eval "use Digest::MD5;1" ) {
|
|
$key = Digest::MD5::md5_hex( unpack "H*", $key );
|
|
$key .= Digest::MD5::md5_hex($key);
|
|
}
|
|
for my $char ( split //, $value ) {
|
|
my $encode = chop($key);
|
|
$enc .= sprintf( "%.2x", ord($char) ^ ord($encode) );
|
|
$key = $encode . $key;
|
|
}
|
|
my $err = setKeyValue( $index, $enc );
|
|
return "error while saving the value - $err" if ( defined($err) );
|
|
return;
|
|
}
|
|
|
|
sub vitoconnect_ReadKeyValue {
|
|
#####################################################
|
|
# reads obfuscated value
|
|
|
|
my ( $hash, $kName ) = @_;
|
|
my $name = $hash->{NAME};
|
|
|
|
my $index = $hash->{TYPE} . "_" . $hash->{NAME} . "_" . $kName;
|
|
my $key = getUniqueId() . $index;
|
|
|
|
my ( $value, $err );
|
|
|
|
Log3 $name, 5,
|
|
"$name - ReadKeyValue tries to read value for $kName from file";
|
|
( $err, $value ) = getKeyValue($index);
|
|
|
|
if ( defined($err) ) {
|
|
Log3 $name, 1,
|
|
"$name - ReadKeyValue is unable to read value from file: $err";
|
|
return;
|
|
}
|
|
|
|
if ( defined($value) ) {
|
|
if ( eval "use Digest::MD5;1" ) {
|
|
$key = Digest::MD5::md5_hex( unpack "H*", $key );
|
|
$key .= Digest::MD5::md5_hex($key);
|
|
}
|
|
my $dec = '';
|
|
for my $char ( map { pack( 'C', hex($_) ) } ( $value =~ /(..)/g ) ) {
|
|
my $decode = chop($key);
|
|
$dec .= chr( ord($char) ^ ord($decode) );
|
|
$key = $decode . $key;
|
|
}
|
|
return $dec;
|
|
}
|
|
else {
|
|
Log3 $name, 1, "$name - ReadKeyValue could not find key $kName in file";
|
|
return;
|
|
}
|
|
return;
|
|
}
|
|
|
|
1;
|
|
|
|
=pod
|
|
=item device
|
|
=item summary support for Viessmann API
|
|
=item summary_DE Unterstützung für die Viessmann API
|
|
=begin html
|
|
|
|
<a name="vitoconnect"></a>
|
|
<h3>vitoconnect</h3>
|
|
<ul>
|
|
<i>vitoconnect</i> implements a device for the Viessmann API
|
|
<a href="https://www.viessmann.de/de/viessmann-apps/vitoconnect.html">Vitoconnect100</a>
|
|
based on investigation of
|
|
<a href="https://github.com/thetrueavatar/Viessmann-Api">thetrueavatar</a><br>
|
|
|
|
You need the user and password from the ViCare App account.<br>
|
|
Attention: This module is limited to one 'installation' per account. If you have two or more heaters use one viessmann account and device for each heater.<br>
|
|
|
|
For details see: <a href="https://wiki.fhem.de/wiki/Vitoconnect">FHEM Wiki (german)</a><br><br>
|
|
|
|
vitoconnect needs the following libraries:
|
|
<ul>
|
|
<li>Path::Tiny</li>
|
|
<li>JSON</li>
|
|
<li>DateTime</li>
|
|
</ul>
|
|
|
|
Use <code>sudo apt install libtypes-path-tiny-perl libjson-perl libdatetime-perl</code> or
|
|
install the libraries via cpan.
|
|
Otherwise you will get an error message "cannot load module vitoconnect".
|
|
|
|
<br><br>
|
|
<a name="vitoconnectdefine"></a>
|
|
<b>Define</b>
|
|
<ul>
|
|
<code>define <name> vitoconnect <user> <password> <interval></code><br>
|
|
It is a good idea to use a fake password here an set the correct one later because it is
|
|
readable in the detail view of the device
|
|
<br><br>
|
|
Example:<br>
|
|
<code>define vitoconnect vitoconnect user@mail.xx fakePassword 60</code><br>
|
|
<code>set vitoconnect password correctPassword 60</code>
|
|
<br><br>
|
|
|
|
</ul>
|
|
<br>
|
|
|
|
<a name="vitoconnectset"></a>
|
|
<b>Set</b><br>
|
|
<ul>
|
|
<li><code>update</code><br>
|
|
update readings immeadiatlely</li>
|
|
<li><code>clearReadings</code><br>
|
|
clear all readings immeadiatlely</li>
|
|
<li><code>password passwd</code><br>
|
|
store password in key store</li>
|
|
<li><code>logResponseOnce</code><br>
|
|
dumps the json response of Viessmann server to entities.json,
|
|
gw.json, actions.json in FHEM log directory</li>
|
|
|
|
<li><code>HK1-Heizkurve-Niveau shift</code><br>
|
|
set shift of heating curve</li>
|
|
<li><code>HK1-Heizkurve-Steigung slope</code><br>
|
|
set slope of heating curve</li>
|
|
|
|
<li><code>HK1-Urlaub_Start start</code><br>
|
|
set holiday start time <br>
|
|
start has to look like this: 2019-02-02</li>
|
|
<li><code>HK1-Urlaub_Ende end</code><br>
|
|
set holiday end time <br>
|
|
end has to look like this: 2019-02-16</li>
|
|
<li><code>HK1-Urlaub_unschedule</code> <br>
|
|
remove holiday start and end time </li>
|
|
|
|
<li><code>HK1-Zeitsteuerung_Heizung schedule</code><br>
|
|
sets the heating schedule in JSON format <br>
|
|
e.g. {"mon":[],"tue":[],"wed":[],"thu":[],"fri":[],"sat":[],"sun":[]} is completly off
|
|
and {"mon":[{"mode":"on","start":"00:00","end":"24:00","position":0}],
|
|
"tue":[{"mode":"on","start":"00:00","end":"24:00","position":0}],
|
|
"wed":[{"mode":"on","start":"00:00","end":"24:00","position":0}],
|
|
"thu":[{"mode":"on","start":"00:00","end":"24:00","position":0}],
|
|
"fri":[{"mode":"on","start":"00:00","end":"24:00","position":0}],
|
|
"sat":[{"mode":"on","start":"00:00","end":"24:00","position":0}],
|
|
"sun":[{"mode":"on","start":"00:00","end":"24:00","position":0}]} is on 24/7</li>
|
|
|
|
<li><code>HK1-Betriebsart standby,dhw,dhwAndHeating,forcedReduced,forcedNormal</code> <br>
|
|
sets HK1-Betriebsart to standby,dhw,dhwAndHeating,forcedReduced or forcedNormal</li>
|
|
|
|
<li><code>HK1-Solltemperatur_comfort_aktiv activate,deactivate</code> <br>
|
|
activate/deactivate comfort temperature</li>
|
|
<li><code>HK1-Solltemperatur_comfort targetTemperature</code><br>
|
|
set comfort target temperatur </li>
|
|
<li><code>HK1-Solltemperatur_eco_aktiv activate,deactivate </code><br>
|
|
activate/deactivate eco temperature</li>
|
|
|
|
<li><code>HK1-Solltemperatur_normal targetTemperature</code><br>
|
|
sets the normale target temperature where targetTemperature is an
|
|
integer between 3 and 37</li>
|
|
<li><code>HK1-Solltemperatur_reduziert targetTemperature</code><br>
|
|
sets the reduced target temperature where targetTemperature is an
|
|
integer between 3 and 37 </li>
|
|
|
|
<li><code>HK1-Name name</code><br>
|
|
sets the name of the circuit </li>
|
|
|
|
<li><code>WW-einmaliges_Aufladen activate,deactivate</code><br>
|
|
activate or deactivate one time charge for hot water </li>
|
|
|
|
<li><code>WW-Zirkulationspumpe_Zeitplan schedule</code><br>
|
|
sets the schedule in JSON format for hot water circulation pump </li>
|
|
<li><code>WW-Zeitplan schedule</code> <br>
|
|
sets the schedule in JSON format for hot water </li>
|
|
|
|
<li><code>WW-Haupttemperatur targetTemperature</code><br>
|
|
targetTemperature is an integer between 10 and 60<br>
|
|
sets hot water main temperature to targetTemperature </li>
|
|
<li><code>WW-Solltemperatur targetTemperature</code><br>
|
|
targetTemperature is an integer between 10 and 60<br>
|
|
sets hot water temperature to targetTemperature </li>
|
|
|
|
<li><code>Urlaub_Start start</code><br>
|
|
set holiday start time <br>
|
|
start has to look like this: 2019-02-02</li>
|
|
<li><code>Urlaub_Ende end</code><br>
|
|
set holiday end time <br>
|
|
end has to look like this: 2019-02-16</li>
|
|
<li><code>Urlaub_unschedule</code> <br>
|
|
remove holiday start and end time </li>
|
|
|
|
</ul>
|
|
<br>
|
|
|
|
<a name="vitoconnectget"></a>
|
|
<b>Get</b><br>
|
|
<ul>
|
|
nothing to get here
|
|
</ul>
|
|
<br>
|
|
|
|
<a name="vitoconnectattr"></a>
|
|
<b>Attributes</b>
|
|
<ul>
|
|
<code>attr <name> <attribute> <value></code>
|
|
<br><br>
|
|
See <a href="http://fhem.de/commandref.html#attr">commandref#attr</a> for more info about
|
|
the attr command.
|
|
<br><br>
|
|
Attributes:
|
|
<ul>
|
|
<li><i>disable</i>:<br>
|
|
stop communication with Viessmann server
|
|
</li>
|
|
<li><i>verbose</i>:<br>
|
|
set the verbosity level
|
|
</li>
|
|
<li><i>vitoconnect_raw_readings</i>:<br>
|
|
create readings with plain JSON names like 'heating.circuits.0.heating.curve.slope'
|
|
instead of german identifiers
|
|
</li>
|
|
<li><i>vitoconnect_gw_readings</i>:<br>
|
|
create readings from the gateway
|
|
</li>
|
|
|
|
<li><i>vitoconnect_actions_active</i>:<br>
|
|
create readings for actions e.g. 'heating.circuits.0.heating.curve.setCurve'
|
|
</li>
|
|
</ul>
|
|
</ul>
|
|
|
|
<a name="vitoconnectreadings"></a>
|
|
<b>Readings</b>
|
|
<br><br>
|
|
<i>vitoconnect</i> sets one reading for every value delivered by
|
|
the API (depends on the type and the settings of your heater and the version of the API!).
|
|
Already known values will be mapped to clear names. Unknown values will added with their JSON path
|
|
(e.g. "heating.burner.modulation.value").
|
|
Please report new readings to the module maintainer. A description of the known reading
|
|
could be found <a href="https://wiki.fhem.de/wiki/Vitoconnect">here (german)</a>
|
|
|
|
</ul>
|
|
|
|
=end html
|
|
|
|
=cut
|
|
|
|
=cut
|