<a name="OWX"></a>
|
|
<h3>OWX</h3>
|
|
<ul>
|
|
FHEM module to commmunicate with 1-Wire bus devices
|
|
<ul>
|
|
<li>via an active DS2480/DS2482/DS2490/DS9097U bus master
|
|
interface attached to an USB port or</li>
|
|
<li>via a passive DS9097 interface attached to an USB port or</li>
|
|
<li>via a network-attached CUNO</li>
|
|
</ul>
|
|
Internally these interfaces are vastly different, read the
|
|
corresponding
|
|
<a href="http://fhemwiki.de/wiki/Interfaces_f%C3%BCr_1-Wire"> Wiki
|
|
pages </a>
|
|
<br />
|
|
<br />
|
|
<b>Example</b>
|
|
<br />
|
|
<ul>
|
|
<code>define OWio OWX /dev/ttyUSB1</code>
|
|
<br />
|
|
</ul>
|
|
<br />
|
|
<a name="OWXdefine"> <b>Define</b></a>
|
|
<ul>
|
|
<code>define <name> OWX <serial-device></code>
|
|
or
|
|
<br />
|
|
<code>define <name> OWX <cuno-device></code>
|
|
<br />
|
|
<br /> Define a 1-Wire interface to communicate with a 1-Wire bus.
|
|
<br />
|
|
<br />
|
|
<li><code><serial-device></code> The serial device (e.g.
|
|
USB port) to which the 1-Wire bus is attached.</li>
|
|
<li><code><cuno-device></code> The previously defined CUNO
|
|
to which the 1-Wire bus is attached.</li>
|
|
</ul>
|
|
<br />
|
|
<a name="OWXset"> <b>Set</b></a>
|
|
<ul>
|
|
<li><a name="owx_interval"> <code>set <name>
|
|
interval <value></code>
|
|
</a> <br />
|
|
<br /> sets the time period in seconds for "kicking" the 1-Wire bus
|
|
(default is 300 seconds). This means:
|
|
<ul>
|
|
<li>With 1-Wire bus interfaces that do not supply power to the
|
|
1-Wire bus (attr buspower parasitic), the 1-Wire bus is reset at
|
|
these intervals.</li>
|
|
<li>With 1-Wire bus interfaces that supply power to the 1-Wire
|
|
bus (attr buspower = real), all temperature measurement devices on
|
|
the bus receive the command to start a temperature conversion
|
|
(saves a lot of time when reading)</li>
|
|
<li>With 1-Wire bus interfaces that contain a busmaster chip,
|
|
the response to a reset pulse contains information about alarms.</li>
|
|
</ul>
|
|
<br /></li>
|
|
<li><a name="owx_followAlarms"> <code>set
|
|
<name> followAlarms on|off</code>
|
|
</a> <br />
|
|
<br /> instructs the module to start an alarm search in case a reset
|
|
pulse discovers any 1-Wire device which has the alarm flag set.</li>
|
|
</ul>
|
|
<br />
|
|
<a name="OWXget"> <b>Get</b></a>
|
|
<ul>
|
|
<li><a name="owx_alarms"></a> <code>get <name>
|
|
alarms</code> <br />
|
|
<br /> performs an "alarm search" for devices on the 1-Wire bus and,
|
|
if found, generates an event in the log (not with CUNO).</li>
|
|
<br />
|
|
<li><a name="owx_devices"></a> <code>get <name>
|
|
devices</code> <br />
|
|
<br /> redicovers all devices on the 1-Wire bus. If a device found
|
|
has a previous definition, this is automatically used. If a device
|
|
is found but has no definition, it is autocreated. If a defined
|
|
device is not on the 1-Wire bus, it is autodeleted.</li>
|
|
<br />
|
|
<br />
|
|
</ul>
|
|
<a name="OWXattr"> <b>Attributes</b></a>
|
|
<ul>
|
|
<li><a name="OWXbuspower"><code>attr <name>
|
|
buspower real|parasitic</code></a> <br />tells FHEM whether power is
|
|
supplied to the 1-Wire bus or not.</li>
|
|
<li>Standard attributes alias, comment, eventMap, logLevel,
|
|
webCmd</li>
|
|
</ul>
|
|
</ul>
|
|
<!--+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++-->
|
|
<a name="OWAD"></a>
|
|
<h3>OWAD</h3>
|
|
<ul>
|
|
FHEM module to commmunicate with 1-Wire A/D converters
|
|
<br />
|
|
<br /> Note:
|
|
<br /> This 1-Wire module so far works only with the OWX interface
|
|
module. Please define an
|
|
<a href="#OWX">OWX</a> device first.
|
|
<br />
|
|
<br />
|
|
<b>Example</b>
|
|
<br />
|
|
<ul>
|
|
<code>define OWX_AD OWAD 724610000000 45</code>
|
|
<br />
|
|
<code>attr OWX_AD DAlarm high</code>
|
|
<br />
|
|
<code>attr OWX_AD DFactor 31.907097</code>
|
|
<br />
|
|
<code>attr OWX_AD DHigh 50.0</code>
|
|
<br />
|
|
<code>attr OWX_AD DName RelHumidity|humidity</code>
|
|
<br />
|
|
<code>attr OWX_AD DOffset -0.8088</code>
|
|
<br />
|
|
<code>attr OWX_AD DUnit percent|%</code>
|
|
<br />
|
|
</ul>
|
|
<br />
|
|
<a name="OWADdefine"></a>
|
|
<b>Define</b>
|
|
<ul>
|
|
<code>define <name> OWAD [<model>] <id>
|
|
[<interval>]</code>
|
|
<br />
|
|
<br /> Define a 1-Wire A/D converter.
|
|
<br />
|
|
<br />
|
|
<li><code>[<model>]</code><br /> Defines the A/D
|
|
converter model (and thus 1-Wire family id), currently the following
|
|
values are permitted:
|
|
<ul>
|
|
<li>model DS2450 with family id 20 (default if the model
|
|
parameter is omitted)</li>
|
|
</ul></li>
|
|
<li><code><id></code> <br />12-character unique ROM id of
|
|
the converter device without family id and CRC code</li>
|
|
<li><code><interval></code> <br />Measurement interval in
|
|
seconds. The default is 300 seconds.</li>
|
|
<br />
|
|
</ul>
|
|
<br />
|
|
<a name="OWADset"> <b>Set</b></a>
|
|
<ul>
|
|
<li><a name="owad_interval"> <code>set <name>
|
|
interval <int></code></a><br /> Measurement interval in seconds. The
|
|
default is 300 seconds.</li>
|
|
</ul>
|
|
<br />
|
|
<a name="OWADget"> <b>Get</b></a>
|
|
<ul>
|
|
<li><a name="owad_id"> <code>get <name> id</code></a> <br />
|
|
Returns the full 1-Wire device id OW_FAMILY.ROM_ID.CRC</li>
|
|
<li><a name="owad_present"> <code>get <name>
|
|
present</code>
|
|
</a> <br /> Returns 1 if this 1-Wire device is present, otherwise 0.</li>
|
|
<li><a name="owad_interval2"> <code>get <name>
|
|
interval</code></a><br />Returns measurement interval in seconds.</li>
|
|
<li><a name="owad_reading"> <code>get <name>
|
|
reading</code></a><br />Obtain the measuement values.</li>
|
|
<li><a name="owad_alarm"> <code>get <name>
|
|
alarm</code></a><br />Obtain the alarm values.</li>
|
|
<li><a name="owad_status"> <code>get <name>
|
|
status</code></a><br />Obtain the i/o status values.</li>
|
|
</ul>
|
|
<br />
|
|
<a name="OWADattr"> <b>Attributes</b></a>
|
|
<ul>
|
|
<li><a name="owad_stateAL0"><code>attr <name>
|
|
stateAL0 <string></code></a> <br />character string for denoting low
|
|
normal condition, default is green down triangle, e.g. the code
|
|
<span style="color:green">&#x25BE;</span> leading to
|
|
the sign <span style="color: green">▾</span></li>
|
|
<li><a name="owad_stateAH0"><code>attr <name>
|
|
stateAH0 <string></code></a> <br />character string for denoting high
|
|
alarm condition, default is green upward triangle, e.g. the code
|
|
<span style="color:green">&#x25B4;</span> leading to
|
|
the sign <span style="color: green">▴</span></li>
|
|
<li><a name="owad_stateAL1"><code>attr <name>
|
|
stateAL1 <string></code></a> <br />character string for denoting low
|
|
alarm condition, default is red down triangle, e.g. the code
|
|
<span style="color:red">&#x25BE;</span> leading to
|
|
the sign <span style="color: red">▾</span></li>
|
|
<li><a name="owad_stateAH1"><code>attr <name>
|
|
stateAH1 <string></code></a> <br />character string for denoting high
|
|
alarm condition, default is red upward triangle, e.g. the code
|
|
<span style="color:red">&#x25B4;</span> leading to
|
|
the sign <span style="color: red">▴</span></li>
|
|
</ul>
|
|
For each of the following attributes, the channel identification
|
|
A,B,C,D may be used.
|
|
<ul>
|
|
<li><a name="owad_cname"><code>attr <name>
|
|
<channel>Name <string>|<string></code></a> <br />name for
|
|
the channel | a type description for the measured value.</li>
|
|
<li><a name="owad_cunit"><code>attr <name>
|
|
<channel>Unit <string>|<string></code></a> <br />unit of
|
|
measurement for this channel | its abbreviation.</li>
|
|
<li><a name="owad_coffset"><code>attr <name>
|
|
<channel>Offset <float></code></a> <br />offset added to the
|
|
reading in this channel.</li>
|
|
<li><a name="owad_cfactor"><code>attr <name>
|
|
<channel>Factor <float></code></a> <br />factor multiplied to
|
|
(reading+offset) in this channel.</li>
|
|
<li><a name="owad_calarm"><code>attr <name>
|
|
<channel>Alarm <string></code></a> <br />alarm setting in this
|
|
channel, either both, low, high or none (default).</li>
|
|
<li><a name="owad_clow"><code>attr <name>
|
|
<channel>Low <float></code></a> <br />measurement value (on the
|
|
scale determined by offset and factor) for low alarm.</li>
|
|
<li><a name="owad_chigh"><code>attr <name>
|
|
<channel>High <float></code></a> <br />measurement value (on the
|
|
scale determined by offset and factor) for high alarm.</li>
|
|
<li>Standard attributes alias, comment, eventMap, logLevel,
|
|
webCmd</li>
|
|
</ul>
|
|
</ul>
|
|
<!--+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++-->
|
|
<a name="OWCOUNT"></a>
|
|
<h3>OWCOUNT</h3>
|
|
<ul>
|
|
FHEM module to commmunicate with 1-Wire Counter/RAM DS2423 #
|
|
<br />
|
|
<br /> Note:
|
|
<br /> This 1-Wire module so far works only with the OWX interface
|
|
module. Please define an
|
|
<a href="#OWX">OWX</a> device first.
|
|
<br />
|
|
<br />
|
|
<b>Example</b>
|
|
<br />
|
|
<ul>
|
|
<code>define OWX_C OWCOUNT DS2423 CE780F000000 300</code>
|
|
<br />
|
|
<code>attr OWX_C AName Water|volume</code>
|
|
<br />
|
|
<code>attr OWX_C AUnit liters|l</code>
|
|
<br />
|
|
<code>attr OWX_CAMode daily</code>
|
|
<br />
|
|
</ul>
|
|
<br />
|
|
<a name="OWCOUNTdefine"></a>
|
|
<b>Define</b>
|
|
<ul>
|
|
<code>define <name> OWCOUNT [<model>] <id>
|
|
[<interval>]</code>
|
|
<br />
|
|
<br /> Define a 1-Wire counter.
|
|
<br />
|
|
<br />
|
|
<li><code>[<model>]</code><br /> Defines the counter
|
|
model (and thus 1-Wire family id), currently the following values
|
|
are permitted:
|
|
<ul>
|
|
<li>model DS2423 with family id 1D (default if the model
|
|
parameter is omitted)</li>
|
|
</ul></li>
|
|
<li><code><id></code> <br />12-character unique ROM id of
|
|
the converter device without family id and CRC code</li>
|
|
<li><code><interval></code> <br />Measurement interval in
|
|
seconds. The default is 300 seconds.</li>
|
|
</ul>
|
|
<br />
|
|
<a name="OWCOUNTset"> <b>Set</b></a>
|
|
<ul>
|
|
<li><a name="owcount_interval"> <code>set
|
|
<name> interval <int></code></a><br /> Measurement interval in
|
|
seconds. The default is 300 seconds.</li>
|
|
<li><a name="owcount_memory"> <code>set <name>
|
|
memory <page></code></a><br />Write 32 bytes to memory page 0..13</li>
|
|
<li><a name="owcount_midnight"> <code>set
|
|
<name> midnight <channel-name></code></a><br />Write the day's
|
|
starting value for counter <channel> (A, B or named channel,
|
|
see below)</li>
|
|
</ul>
|
|
<br />
|
|
<a name="OWCOUNTget"> <b>Get</b></a>
|
|
<ul>
|
|
<li><a name="owcount_id"> <code>get <name> id</code></a> <br />
|
|
Returns the full 1-Wire device id OW_FAMILY.ROM_ID.CRC</li>
|
|
<li><a name="owcount_present"> <code>get <name>
|
|
present</code>
|
|
</a> <br /> Returns 1 if this 1-Wire device is present, otherwise 0.</li>
|
|
<li><a name="owcount_interval2"> <code>get
|
|
<name> interval</code></a><br />Returns measurement interval in
|
|
seconds.</li>
|
|
<li><a name="owcount_memory2"> <code>get <name>
|
|
memory <page></code></a><br />Obtain 32 bytes from memory page 0..13</li>
|
|
<li><a name="owcount_midnight2"> <code>get
|
|
<name> midnight <channel-name></code></a><br />Obtain the day's
|
|
starting value for counter <channel> (A, B or named channel,
|
|
see below)</li>
|
|
<li><a name="owcount_counter"> <code>get <name>
|
|
counter <channel-name></code></a><br />Obtain the current value for
|
|
counter <channel> (A, B or named channel, see below)</li>
|
|
<li><a name="owcount_counters"> <code>get
|
|
<name> counters</code></a><br />Obtain the current value both counters</li>
|
|
</ul>
|
|
<br />
|
|
<a name="OWCOUNTattr"> <b>Attributes</b></a>
|
|
<ul>
|
|
For each of the following attributes, the channel identification A,B
|
|
may be used.
|
|
<li><a name="owcount_cname"><code>attr <name>
|
|
<channel>Name <string>|<string></code></a> <br />name for
|
|
the channel | a type description for the measured value.</li>
|
|
<li><a name="owcount_cunit"><code>attr <name>
|
|
<channel>Unit <string>|<string></code></a> <br />unit of
|
|
measurement for this channel | its abbreviation.</li>
|
|
<li><a name="owcount_coffset"><code>attr <name>
|
|
<channel>Offset <float></code></a> <br />offset added to the
|
|
reading in this channel.</li>
|
|
<li><a name="owcount_cfactor"><code>attr <name>
|
|
<channel>Factor <float></code></a> <br />factor multiplied to
|
|
(reading+offset) in this channel.</li>
|
|
<li><a name="owcount_cmode"><code>attr <name>
|
|
<channel>Mode daily | normal</code></a> <br />factor multiplied to
|
|
(reading+offset) in this channel.</li>
|
|
<li>Standard attributes alias, comment, eventMap, logLevel,
|
|
webCmd</li>
|
|
</ul>
|
|
</ul>
|
|
<!--+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++-->
|
|
<a name="OWID"></a>
|
|
<h3>OWID</h3>
|
|
<ul>
|
|
FHEM module for 1-Wire devices that know only their unique ROM ID
|
|
<br />
|
|
<br />Note:
|
|
<br /> This 1-Wire module so far works only with the OWX interface
|
|
module. Please define an
|
|
<a href="#OWX">OWX</a> device first.
|
|
<br />
|
|
<br />
|
|
<b>Example</b>
|
|
<br />
|
|
<ul>
|
|
<code>define ROM1 OWX_ID OWCOUNT CE780F000000</code>
|
|
<br />
|
|
</ul>
|
|
<br />
|
|
<a name="OWIDdefine"></a>
|
|
<b>Define</b>
|
|
<ul>
|
|
<code>define <name> OWID <id> </code>
|
|
<br />
|
|
<br /> Define a 1-Wire device.
|
|
<br />
|
|
<br />
|
|
<li><code><id></code> <br />12-character unique ROM id of
|
|
the converter device without family id and CRC code</li>
|
|
</ul>
|
|
<br />
|
|
<a name="OWIDget"> <b>Get</b></a>
|
|
<ul>
|
|
<li><a name="owid_id"> <code>get <name> id</code></a> <br />
|
|
Returns the full 1-Wire device id OW_FAMILY.ROM_ID.CRC</li>
|
|
<li><a name="owid_present"> <code>get <name>
|
|
present</code>
|
|
</a> <br /> Returns 1 if this 1-Wire device is present, otherwise 0.</li>
|
|
</ul>
|
|
<br />
|
|
</ul>
|
|
<!--+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++-->
|
|
<a name="OWLCD"></a>
|
|
<h3>OWLCD</h3>
|
|
<ul>
|
|
FHEM module to commmunicate with the
|
|
<a href="http://www.louisswart.co.za/1-Wire_Overview.html">1-Wire
|
|
LCD controller</a> from Louis Swart (1-Wire family id FF). See also the
|
|
corresponding
|
|
<a href="http://fhemwiki.de/wiki/1-Wire_Textdisplay">Wiki page.</a>
|
|
<br />
|
|
<br /> Note:
|
|
<br /> This 1-Wire module so far works only with the OWX interface
|
|
module. Please define an
|
|
<a href="#OWX">OWX</a> device first.
|
|
<br />
|
|
<br />
|
|
<b>Example</b>
|
|
<br />
|
|
<ul>
|
|
<code>define OWX_LCD OWLCD 9F0700000100</code>
|
|
<br />
|
|
</ul>
|
|
<br />
|
|
<a name="OWLCDdefine"></a>
|
|
<b>Define</b>
|
|
<ul>
|
|
<code>define <name> OWLCD <id></code>
|
|
<br />
|
|
<br /> Define a 1-Wire LCD device.
|
|
<br />
|
|
<br />
|
|
<li><code><id></code> <br />12-character unique ROM id of
|
|
the converter device without family id and CRC code</li>
|
|
</ul>
|
|
<br />
|
|
<a name="OWLCDset"> <b>Set</b></a>
|
|
<ul>
|
|
<li><a name="owlcd_icon"> <code>set <name> icon
|
|
<int> on|off|blink</code></a><br /> Set one of the icons 0..14 on, off
|
|
or blinking</li>
|
|
<li><a name="owlcd_icon2"> <code>set <name>
|
|
icon 15 0..6</code></a><br /> Set icon 15 to one of its values</li>
|
|
<li><a name="owlcd_icon3"> <code>set <name>
|
|
icon none</code></a><br /> Set all icons off</li>
|
|
<li><a name="owlcd_line"> <code>set <name> line
|
|
<int> <string></code></a><br /> Write LCD line 0..3 with some
|
|
content</li>
|
|
<li><a name="owlcd_memory"> <code>set <name>
|
|
memory <page> <string></code></a><br />Write memory page 0..6</li>
|
|
<li><a name="owlcd_gpio"> <code>set <name> gpio
|
|
<value></code></a><br />Write state for all three gpio pins (value =
|
|
0..7, for each bit 0=ON, 1=OFF)</li>
|
|
<li><a name="owlcd_bl"> <code>set <name>
|
|
backlight ON|OFF</code></a><br />Switch backlight on or off</li>
|
|
<li><a name="owlcd_lcd"> <code>set <name> lcd
|
|
ON|OFF</code></a><br />Switch LCD power on or off</li>
|
|
<li><a name="owlcd_gpio"> <code>set <name>
|
|
reset</code></a><br />Reset the display</li>
|
|
<li><a name="owlcd_gpio"> <code>set <name> test</code></a><br />Test
|
|
the display</li>
|
|
</ul>
|
|
<br />
|
|
<a name="owlcdget"> <b>Get</b></a>
|
|
<ul>
|
|
<li><a name="owlcd_id"> <code>get <name> id</code></a> <br />
|
|
Returns the full 1-Wire device id OW_FAMILY.ROM_ID.CRC</li>
|
|
<li><a name="owlcd_present"> <code>get <name>
|
|
present</code>
|
|
</a> <br /> Returns 1 if this 1-Wire device is present, otherwise 0.</li>
|
|
<li><a name="owlcd_memory2"> <code>get <name>
|
|
memory <page></code></a><br />Read memory page 0..6</li>
|
|
<li><a name="owlcd_gpio"> <code>get <name> gpio</code></a><br />Obtain
|
|
state of all four input channels (15 = all off, 0 = all on)</li>
|
|
<li><a name="owlcd_counter"> <code>get <name>
|
|
gpio</code></a><br />Obtain state of all four input counters (4 x 16 Bit)</li>
|
|
<li><a name="owlcd_version"> <code>get <name>
|
|
version</code></a><br />Obtain firmware version of the controller</li>
|
|
</ul>
|
|
<br />
|
|
<a name="owlcdattr"> <b>Attributes</b></a>
|
|
<ul>
|
|
<li>Standard attributes alias, comment, eventMap, logLevel,
|
|
webCmd</li>
|
|
</ul>
|
|
</ul>
|
|
<!--+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++-->
|
|
<a name="OWSWITCH"></a>
|
|
<h3>OWSWITCH</h3>
|
|
<ul>
|
|
FHEM module to commmunicate with 1-Wire Programmable Switches
|
|
<br />
|
|
<br /> Note:
|
|
<br /> This 1-Wire module so far works only with the OWX interface
|
|
module. Please define an
|
|
<a href="#OWX">OWX</a> device first.
|
|
<br />
|
|
<br />
|
|
<b>Example</b>
|
|
<br />
|
|
<ul>
|
|
<code>define OWX_S OWSWITCH DS2413 B5D502000000 60</code>
|
|
<br />
|
|
<code>attr OWX_S AName Lampe|light</code>
|
|
<br />
|
|
<code>attr OWX_S AUnit AN|AUS</code>
|
|
<br />
|
|
</ul>
|
|
<br />
|
|
<a name="OWSWITCHdefine"></a>
|
|
<b>Define</b>
|
|
<ul>
|
|
<code>define <name> OWSWITCH [<model>] <id>
|
|
[<interval>]</code>
|
|
<br />
|
|
<br /> Define a 1-Wire switch.
|
|
<br />
|
|
<br />
|
|
<li><code>[<model>]</code><br /> Defines the switch model
|
|
(and thus 1-Wire family id), currently the following values are
|
|
permitted:
|
|
<ul>
|
|
<li>model DS2413 with family id 3A (default if the model
|
|
parameter is omitted)</li>
|
|
</ul></li>
|
|
<li><code><id></code> <br />12-character unique ROM id of
|
|
the converter device without family id and CRC code</li>
|
|
<li><code><interval></code> <br />Measurement interval in
|
|
seconds. The default is 300 seconds.</li>
|
|
</ul>
|
|
<br />
|
|
<a name="OWSWITCHset"> <b>Set</b></a>
|
|
<ul>
|
|
<li><a name="owswitch_interval"> <code>set
|
|
<name> interval <int></code></a><br /> Measurement interval in
|
|
seconds. The default is 300 seconds.</li>
|
|
<li><a name="owswitch_output"> <code>set <name>
|
|
output <channel-name> ON | OFF</code></a><br />Switch channel on/off
|
|
(A, B or named channel, see below)</li>
|
|
<li><a name="owswitch_gpio"> <code>set <name>
|
|
gpio <value></code></a><br />Write state for all channels (for each
|
|
bit 0=ON, 1=OFF)</li>
|
|
</ul>
|
|
<br />
|
|
<a name="OWSWITCHget"> <b>Get</b></a>
|
|
<ul>
|
|
<li><a name="owswitch_id"> <code>get <name> id</code></a>
|
|
<br /> Returns the full 1-Wire device id OW_FAMILY.ROM_ID.CRC</li>
|
|
<li><a name="owswitch_present"> <code>get
|
|
<name> present</code>
|
|
</a> <br /> Returns 1 if this 1-Wire device is present, otherwise 0.</li>
|
|
<li><a name="owswitch_interval2"> <code>get
|
|
<name> interval</code></a><br />Returns measurement interval in
|
|
seconds.</li>
|
|
<li><a name="owswitch_input"> <code>get <name>
|
|
INPUT <channel-name></code></a><br />Obtain state of channel (A, B or
|
|
named channel, see below)</li>
|
|
<li><a name="owswitch_gpio"> <code>get <name>
|
|
gpio</code></a><br />Obtain state of all channels</li>
|
|
</ul>
|
|
<br />
|
|
<a name="OWSWITCHattr"> <b>Attributes</b></a> For each of the
|
|
following attributes, the channel identification A,B may be used.
|
|
<ul>
|
|
<li><a name="owswitch_cname"><code>attr <name>
|
|
<channel>Name <string>|<string></code></a> <br />name for
|
|
the channel | a type description for the measured value.</li>
|
|
<li><a name="owswitch_cunit"><code>attr <name>
|
|
<channel>Unit <string>|<string></code></a> <br />display
|
|
for on | off condition</li>
|
|
<li>Standard attributes alias, comment, eventMap, logLevel,
|
|
webCmd</li>
|
|
</ul>
|
|
</ul>
|
|
<!--+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++-->
|
|
<a name="OWTHERM"></a>
|
|
<h3>OWTHERM</h3>
|
|
<ul>
|
|
FHEM module to commmunicate with 1-Wire bus digital thermometer
|
|
devices
|
|
<br />
|
|
<br /> Note:
|
|
<br /> This is the only 1-Wire module which so far works with both
|
|
the OWFS and the OWX interface module. Please define an
|
|
<a href="#OWFS">OWFS</a> device or an
|
|
<a href="#OWX">OWX</a> device first.
|
|
<br />
|
|
<br />
|
|
<b>Example</b>
|
|
<br />
|
|
<ul>
|
|
<code>define OWX_T OWTHERM DS18B20 E8D09B030000 300</code>
|
|
<br />
|
|
<code>attr OWX_T tempUnit Kelvin</code>
|
|
<br />
|
|
</ul>
|
|
<br />
|
|
<a name="OWTHERMdefine"></a>
|
|
<b>Define</b>
|
|
<ul>
|
|
<code>define <name> OWTHERM [<model>] <id>
|
|
[<interval>]</code>
|
|
<br />
|
|
<br /> Define a 1-Wire digital thermometer device.
|
|
<br />
|
|
<br />
|
|
<li><code>[<model>]</code><br /> Defines the thermometer
|
|
model (and thus 1-Wire family id) currently the following values are
|
|
permitted:
|
|
<ul>
|
|
<li>model DS1820 with family id 10 (default if the model
|
|
parameter is omitted)</li>
|
|
<li>model DS1822 with family id 22</li>
|
|
<li>model DS18B20 with family id 28</li>
|
|
</ul></li>
|
|
<li><code><id></code> <br />12-character unique ROM id of
|
|
the thermometer device without family id and CRC code</li>
|
|
<li><code><interval></code> <br /> Temperature
|
|
measurement interval in seconds. The default is 300 seconds.</li>
|
|
<br /> Example:
|
|
<br />
|
|
<code>define Temp1 OWTHERM 14B598010800 300 </code>
|
|
<br />
|
|
</ul>
|
|
<br />
|
|
<a name="OWTHERMset"> <b>Set</b></a>
|
|
<ul>
|
|
<li><a name="owtherm_interval"> <code>set
|
|
<name> interval <int></code></a><br /> Temperature measurement
|
|
intervall in seconds. The default is 300 seconds.</li>
|
|
<li><a name="owtherm_tempHigh"> <code>set
|
|
<name> tempHigh <float></code></a> <br /> The high alarm
|
|
temperature (on the temperature scale chosen by the attribute value)
|
|
</li>
|
|
<li><a name="owtherm_tempLow"> <code>set <name>
|
|
tempLow <float></code></a> <br /> The low alarm temperature (on the
|
|
temperature scale chosen by the attribute value)</li>
|
|
</ul>
|
|
<br />
|
|
<a name="OWTHERMget"> <b>Get</b></a>
|
|
<ul>
|
|
<li><a name="owtherm_id"> <code>get <name> id</code></a> <br />
|
|
Returns the full 1-Wire device id OW_FAMILY.ROM_ID.CRC</li>
|
|
<li><a name="owtherm_present"> <code>get <name>
|
|
present</code></a> <br /> Returns 1 if this 1-Wire device is present,
|
|
otherwise 0.</li>
|
|
<li><a name="owtherm_interval2"> <code>get
|
|
<name> interval</code></a><br />Returns temperature measurement
|
|
interval in seconds.</li>
|
|
<li><a name="owtherm_temperature"> <code>get
|
|
<name> temperature</code></a><br />Obtain the temperature.</li>
|
|
<li><a name="owtherm_alarm"> <code>get <name>
|
|
alarm</code></a><br />Obtain the alarm temperature values.</li>
|
|
</ul>
|
|
<br />
|
|
<a name="OWTHERMattr"> <b>Attributes</b></a>
|
|
<ul>
|
|
<li><a name="owtherm_stateAL"><code>attr <name>
|
|
stateAL <string></code> </a> <br />character string for denoting low
|
|
alarm condition, default is red down triangle, e.g. the code
|
|
<span style="color:red">&#x25BE;</span> leading to
|
|
the sign <span style="color: red">▾</span></li>
|
|
<li><a name="owtherm_stateAH"><code>attr <name>
|
|
stateAH <string></code> </a> <br />character string for denoting high
|
|
alarm condition, default is red upward triangle, e.g. the code
|
|
<span style="color:red">&#x25B4;</span> leading to
|
|
the sign <span style="color: red">▴</span></li>
|
|
<li><a name="owtherm_tempOffset"><code>attr
|
|
<name> tempOffset <float></code> </a> <br />temperature offset
|
|
in °C added to the raw temperature reading.</li>
|
|
<li><a name="owtherm_tempUnit"><code>attr
|
|
<name> tempUnit Celsius|Kelvin|Fahrenheit|C|K|F</code> </a> <br />unit
|
|
of measurement (temperature scale), default is Celsius = °C</li>
|
|
<li><a name="owtherm_tempHigh2"> <code>attr
|
|
<name> tempHigh <float></code>
|
|
</a> <br /> high alarm temperature (on the temperature scale chosen by
|
|
the attribute value).</li>
|
|
<li><a name="owtherm_tempLow2"> <code>attr
|
|
<name> tempLow <float></code>
|
|
</a> <br /> low alarm temperature (on the temperature scale chosen by
|
|
the attribute value).</li>
|
|
<li>Standard attributes alias, comment, eventMap, logLevel,
|
|
webCmd</li>
|
|
</ul>
|
|
</ul>
|
|
|
|
|
|
<br />
|
|