<!DOCTYPE html PUBLIC "-//W3C//DTD XHTML 1.0 Strict//EN" "http://www.w3.org/TR/xhtml1/DTD/xhtml1-strict.dtd">
|
|
|
|
<html xmlns="http://www.w3.org/1999/xhtml">
|
|
|
|
<head>
|
|
<title>fhem.pl command reference</title>
|
|
</head>
|
|
|
|
<body style="background-color: white;">
|
|
|
|
<h2>fhem.pl command reference</h2>
|
|
|
|
<a href="#intro">Introduction</a><br>
|
|
<a href="#help">?,help</a><br>
|
|
<a href="#attr">attr</a><br>
|
|
<a href="#defattr">defattr</a><br>
|
|
<a href="#define">define</a><br>
|
|
<a href="#delattr">delattr</a><br>
|
|
<a href="#delete">delete</a><br>
|
|
<a href="#get">get</a><br>
|
|
<a href="#include">include</a><br>
|
|
<a href="#inform">inform</a><br>
|
|
<a href="#list">list</a><br>
|
|
<a href="#modify">modify</a><br>
|
|
<a href="#quit">quit</a><br>
|
|
<a href="#reload">reload</a><br>
|
|
<a href="#rereadcfg">rereadcfg</a><br>
|
|
<a href="#save">save</a><br>
|
|
<a href="#set">set</a><br>
|
|
<a href="#setstate">setstate</a><br>
|
|
<a href="#shutdown">shutdown</a><br>
|
|
<a href="#trigger">trigger</a><br>
|
|
<a href="#sleep">sleep</a><br>
|
|
<a href="#xmllist">xmllist</a><br>
|
|
<a href="#perl">Perl specials</a><br>
|
|
|
|
<a name="intro"></a>
|
|
<h3>Introduction</h3>
|
|
You can use all of the following commands in in two ways:
|
|
<ul>
|
|
<li>In the configuration file, which must be specified if you startup the
|
|
server. Example:<br>
|
|
<ul>
|
|
<code>fhem.pl ~/.fhem</code>
|
|
</ul>
|
|
<br>
|
|
A minimal configuration file would look like:
|
|
<pre>
|
|
attr global <a href="#logfile">logfile</a> /tmp/fhem.log
|
|
attr global <a href="#statefile">statefile</a> /tmp/fhem.save
|
|
attr global <a href="#verbose">verbose</a> 3
|
|
attr global <a href="#port">port</a> 7072
|
|
attr global <a href="#modpath">modpath</a> /usr/local/lib
|
|
<a href="#define">define</a> FHZ FHZ /dev/tts/USB0
|
|
|
|
<a href="#define">define</a> lamp FS20 8765 01</pre>
|
|
For other configuration files see the examples subdirectory.<br>
|
|
<br>
|
|
</li>
|
|
|
|
<li>Through the TCP/IP connection, which you can either use in a "session"
|
|
(via telnet) or single client command (via fhem.pl). Example:
|
|
<ul>
|
|
<code>telnet localhost 7072<br>
|
|
<NL> </code>(This newline switches into "prompt" mode)<code><br>
|
|
<command>...<br>
|
|
quit</code><br>
|
|
</ul>
|
|
or
|
|
<ul>
|
|
<code>fhem.pl 7072 "set lamp off"</code>
|
|
</ul>
|
|
</li>
|
|
</ul>
|
|
|
|
There are three types of commands: "fhem" commands (described in this document),
|
|
shell commands (they must be enclosed in double quotes ") and perl expressions
|
|
(enclosed in curly brackets {}). shell commands or perl expressions are needed for
|
|
complex <a href="#at">at</a> or <a href="#notify">notify</a> arguments.<br><br>
|
|
|
|
Shell commands will be executed in the
|
|
background, the perl program and the fhem commands will be executed in the main
|
|
"thread".
|
|
In order to make perl expressions easier to write, some special functions and
|
|
variables are available. See the section <a href="#perl">Perl special</a> for a
|
|
description.
|
|
To trigger "fhem" commands from a shell script, use the client form of
|
|
fhem.pl (described above).<br><br>
|
|
|
|
Multiple fhem commands are separated by semicolon (;). In order to use semicolon
|
|
in perl code or shell programs, they have to be escaped by the double semicolon
|
|
(;;).<br><br>
|
|
|
|
Commands can be either typed in plain, or read from a file (e.g. the
|
|
configuration file at startup). The commands are either executed directly, or
|
|
later if they are arguments to the <a href="#at">at</a> and <a
|
|
href="#notify">notify</a> fhem commands.<br><br>
|
|
|
|
If commands are read from a file, then a line ending with \ will be
|
|
concatenated with the next one, so long lines (e.g. perl oneliners) can be
|
|
split in multiple lines<br><br>
|
|
|
|
|
|
<a name="help"></a>
|
|
<h3>?, help</h3>
|
|
<ul>
|
|
<code>?</code><br>
|
|
<code>help</code><br>
|
|
<br>
|
|
Get a list of all commands and short description for each one
|
|
</ul>
|
|
|
|
|
|
|
|
<a name="attr"></a>
|
|
<h3>attr</h3>
|
|
<ul>
|
|
<code>attr <name> <attrname> [<value>] </code><br>
|
|
or <br>
|
|
<code>attr at <at-spec-regexp> <attribute> </code><br>
|
|
|
|
<br>Set an attribute to something defined by <a href="#define">define</a>.
|
|
There are some special attributes used by the fhem.pl itself or the
|
|
web-frontends, but you can define your own to use them in other applications.
|
|
You have to define them first with <a href="#userattr">userattr</a>, see
|
|
below.<br>
|
|
|
|
Use "attr <name> ?" to get a list of possible attributes.
|
|
<br><br>
|
|
|
|
Following are attributes of the global device:<br>
|
|
|
|
<ul>
|
|
|
|
<a name="configfile"></a>
|
|
<li>configfile<br>
|
|
Contains the name of the configuration file. If <a
|
|
href="#save">save</a> is called without argument, then the output will
|
|
be written to this file.
|
|
</li><br>
|
|
|
|
<a name="lastinclude"></a>
|
|
<li>lastinclude<br>
|
|
If this attribute is set, then the last command of the generated
|
|
configfile (see the <a href="#save">save</a> command) will be<br>
|
|
include <lastinclude-value><br>
|
|
This file is needed, as the save command will write only defines and
|
|
attributes to the config file, any other commands / includes will be
|
|
lost. E.g. it makes sense to set the <a href="FHZset">FHTcode</a> in
|
|
this file or the coordinates of your house via
|
|
<a href="#at">sunrise_coord</at>
|
|
</li><br>
|
|
|
|
<a name="logfile"></a>
|
|
<li>logfile<br>
|
|
Specify the logfile to write. You can use "-" for
|
|
stdout, in this case the server won't background itself.<br>
|
|
The logfile name can also take wildcards for easier logfile rotation,
|
|
see the <a href="#FileLog">FileLog</a> section.
|
|
</li><br>
|
|
|
|
<a name="modpath"></a>
|
|
<li>modpath<br>
|
|
Specify the path to the modules directory <code>FHEM</code>. The path
|
|
should <b>not</b> contain the directory FHEM. Every file there with the
|
|
name pattern <number>_<name>.pm will be loaded in the order
|
|
of the number.
|
|
</li><br>
|
|
|
|
<a name="pidfilename"></a>
|
|
<li>pidfilename<br>
|
|
Write the process id of the perl process to the specified file. The
|
|
server runs as a daemon, and some distributions would like to check by
|
|
the pid if we are still running. The file will be deleted upon
|
|
shutdown.
|
|
</li><br>
|
|
|
|
<a name="pidfilename"></a>
|
|
<li>pidfilename<br>
|
|
Works for the global "device"<br>
|
|
</li><br>
|
|
|
|
<a name="port"></a>
|
|
<li>port<br>
|
|
Listen on the TCP/IP port <code><number></code> for incoming
|
|
connections. To offer at least a little bit of security, the server
|
|
will only listen for connections from the localhost per default. If
|
|
there is a second value "global" then the server will listen for
|
|
non-localhost connections too.
|
|
</li><br>
|
|
|
|
<a name="statefile"></a>
|
|
<li>statefile<br>
|
|
Set the filename where the state and certain <a href="#at">at</a>
|
|
information will be saved before shutdown. If it is not specified, then
|
|
no information will be saved.
|
|
</li><br>
|
|
|
|
<a name="title"></a>
|
|
<li>title<br>
|
|
Used by the web frontend fhemweb.pl (webpgm2) as a Page title.
|
|
</li><br>
|
|
|
|
<a name="userattr"></a>
|
|
<li>userattr<br>
|
|
A space separated list which contains the names of additional
|
|
attributes. Without specifying them you will not be able to set them
|
|
(in order to prevent typos).
|
|
</li><br>
|
|
|
|
<a name="verbose"></a>
|
|
<li>verbose<br>
|
|
Set the verbosity level. Possible values:
|
|
<ul>
|
|
<li>0 - it will only tell you when the server was started, or
|
|
stopped</li>
|
|
<li>1 - it logs all error messages or unknown packets</li>
|
|
<li>2 - it logs all signals received or sent in a "digested"
|
|
format,</li>
|
|
<li>3 - it logs the signals for undefined devices,</li>
|
|
<li>4 - it logs the TCP/IP connections and the called programs with
|
|
parameters,</li>
|
|
<li>5 - is for debugging.</li>
|
|
</ul>
|
|
Recommended level is 3 for normal use.
|
|
</li>
|
|
</ul>
|
|
|
|
<br>
|
|
Attributes used by all devices:
|
|
<ul>
|
|
<a name="comment"></a>
|
|
<li>comment<br>
|
|
Add an arbitrary comment.
|
|
|
|
<a name="room"></a>
|
|
<li>room<br>
|
|
Filter/group devices. Recognized by web-pgm2 and web-pgm3.
|
|
Devices in the room hidden will not appear in the web output.</li><br>
|
|
|
|
<a name="showtime"></a>
|
|
<li>showtime<br>
|
|
Used in the webfrontend pgm2 to show the time of last activity
|
|
instead of the state in the summary view. Useful e.g. for FS20 PIRI
|
|
devices.
|
|
</li>
|
|
</ul>
|
|
|
|
<br>
|
|
Attributes used by some device types:
|
|
<ul>
|
|
<a name="archivedir"></a> <a name="archivecmd"></a> <a name="nrarchive"></a>
|
|
<li>archivecmd / archivedir / nrarchive<br>
|
|
Can be applied to FileLog devices.<br>
|
|
When a new FileLog file is opened, the FileLog archiver wil be called.
|
|
This happens only, if the name of the logfile has changed (due to
|
|
time-specific wildcards, see the <a href="#FileLog">FileLog</a>
|
|
section), and there is a new entry to be written into the file.
|
|
<br>
|
|
|
|
If the attribute archivecmd is specified, then it will be started as a
|
|
shell command (no enclosing " is needed), and each % in the command
|
|
will be replaced with the name of the old logfile.<br>
|
|
|
|
If this attribute is not set, but nrarchive and/or archivecmd is set,
|
|
then all superfluous logfiles will be moved to archivedir (or deleted if
|
|
archivedir is not set).</li><br>
|
|
|
|
<a name="disable"></a>
|
|
<li>disable<br>
|
|
Can be applied to at/notify/FileLog devices.<br>
|
|
Disables the corresponding at/notify or FileLog device. Note:
|
|
If applied to an <a href="#at">at</a>, the command will not be executed,
|
|
but the next time will be computed.</li><br>
|
|
|
|
<a name="do_not_notify"></a>
|
|
<li>do_not_notify<br>
|
|
Can be applied to FHZ/FS20/FHT/HMS/KS300/WS300 devices.<br>
|
|
Disable FileLog/notify/inform notification for a device. This affects
|
|
the received signal, the set and trigger commands.</li><br>
|
|
|
|
<a name="dummy"></a>
|
|
<li>dummy<br>
|
|
Can be applied to FS20/FHT devices.<br>
|
|
Set the device attribute dummy to define devices which should not
|
|
output any radio signals. Associated notifys will be executed if
|
|
the signal is received. Used e.g. to react to a code from a sender, but
|
|
it will not emit radio signal if triggered in the web frontend.
|
|
Implemented for FS20 and FHT devices.</li><br>
|
|
|
|
<a name="filtertimeout"></a>
|
|
<li>filtertimeout<br>
|
|
Can be applied to FHZ devices.<br>
|
|
Ignore duplicate messages for this amount of time. The time is in
|
|
seconds, fractions are allowed. It affects installations with more then
|
|
one FHZ device or repeater, see the <a href="#repeater">repeater</a>
|
|
entry.
|
|
</li><br>
|
|
|
|
<a name="follow-on-for-timer"></a>
|
|
<li>follow-on-for-timer<br>
|
|
Can be applied to FS20 devices.<br>
|
|
the program automatically schedules a "setstate off" for the time
|
|
specified as argument to the on-for-timer command (for the specified
|
|
device only).
|
|
</li><br>
|
|
|
|
<a name="loglevel"></a>
|
|
<li>loglevel<br>
|
|
Can be applied to FHZ/FS20/FHT/HMS/KS300/WS300 devices.<br>
|
|
Set the device loglevel to e.g. 6 if you do not wish messages from a
|
|
given device to appear in the global logfile (FHZ/FS20/FHT). E.g. to
|
|
set the FHT time, you should schedule "set FHZ time" every minute, but
|
|
this in turn makes your logfile unreadable. These messages will not be
|
|
generated if the FHZ attribute loglevel is set to 6.</li><br>
|
|
|
|
<a name="logtype"></a>
|
|
<li>logtype<br>
|
|
Can be applied to FileLog devices.<br>
|
|
Used by the pgm2 webfrontend to offer gnuplot images made from the
|
|
logs. The string is made up of tokens separated by comma (,), each
|
|
token specifies a different gnuplot program. The token may contain a
|
|
colon (:), the part before the colon defines the name of the program,
|
|
the part after is the string displayed in the web frontend. Currently
|
|
following types of gnuplot programs are implemented:<br>
|
|
<ul>
|
|
<li>fs20<br>
|
|
Plots on as 1 and off as 0. The corresponding filelog definition
|
|
for the device fs20dev is:<br>
|
|
define FileLog fslog fs20dev /var/log/fs20dev-%Y-%U.log
|
|
</li>
|
|
<li>fht<br>
|
|
Plots the measured-temp/desired-temp/actuator lines. The
|
|
corresponding filelog definitions (for the FHT device named
|
|
fht1) looks like:<br>
|
|
define FileLog fhtlog1 fht1:.*(temp|actuator).*
|
|
/var/log/fht1-%Y-%U.log
|
|
</li>
|
|
<li>ks300_1<br>
|
|
Plots the temperature and rain (per hour and per day) of a
|
|
ks300. The corresponding filelog definitions (for the KS300
|
|
device named ks300) looks like:<br>
|
|
define FileLog ks300log ks300:.*H:.*
|
|
/var/log/ks300-%Y-%U.log
|
|
</li>
|
|
<li>ks300_2<br>
|
|
Plots the humidity and wind values of a
|
|
ks300. The corresponding filelog definition is the same as
|
|
above, both programs evaluate the same log.
|
|
</li>
|
|
<li>text<br>
|
|
Shows the logfile as it is (plain text).
|
|
</li>
|
|
</ul>
|
|
The corresponding gnuplot files (up to the "text" one) must be
|
|
installed, see the fhemweb.pl configuration for the destination
|
|
directory.<br>
|
|
|
|
Example:<br>
|
|
attr fhtlog1 logtype ks300_1:Temp/Rain,ks300_2:Hum/Wind,text:Raw-data
|
|
</li><br>
|
|
|
|
|
|
<a name="model"></a>
|
|
<li>model<br>
|
|
Can be applied to FHZ/FS20/FHT/HMS/KS300/WS300 devices.<br>
|
|
The model attribute denotes the model type of the device.
|
|
The attributes will (currently) not be used by the fhem.pl directly.
|
|
It can be used by e.g. external programs or web interfaces to
|
|
distinguish classes of devices and send the appropriate commands
|
|
(e.g. "on" or "off" to a fs20st, "dim..%" to fs20du etc.).
|
|
The spelling of the model names are as quoted on the printed
|
|
documentation which comes which each device. This name is used
|
|
without blanks in all lower-case letters. Valid characters should be
|
|
<code>a-z 0-9</code> and <code>-</code> (dash),
|
|
other characters should be ommited. Here is a list of "official"
|
|
devices:<br>
|
|
<ul>
|
|
<li>FHT: fht80b</li>
|
|
<li>FS20:
|
|
fs20hgs
|
|
fs20pira
|
|
fs20piri
|
|
fs20s20
|
|
fs20s8
|
|
fs20s4
|
|
fs20s4a
|
|
fs20s4m
|
|
fs20s4u
|
|
fs20s4ub
|
|
fs20sd
|
|
fs20sn
|
|
fs20sr
|
|
fs20ss
|
|
fs20str
|
|
fs20tfk
|
|
fs20tfk
|
|
fs20tk
|
|
fs20uts
|
|
fs20ze
|
|
|
|
fs20as1
|
|
fs20as4
|
|
fs20di
|
|
fs20du
|
|
fs20ms2
|
|
fs20rst
|
|
fs20sa
|
|
fs20sig
|
|
fs20st
|
|
fs20sv
|
|
fs20sv
|
|
fs20usr
|
|
|
|
</li>
|
|
|
|
<li>HMS: hms100-t hms100-tf hms100-wd hms100-mg hms100-tfk rm100-2</li>
|
|
<li>KS300: ks300</li>
|
|
<li>WS300: ws300pc</li>
|
|
<li>EM1010: em1010pc</li>
|
|
</ul>
|
|
</li><br>
|
|
|
|
<a name="repeater"></a>
|
|
<li>repeater<br>
|
|
Can be applied to FHZ devices.<br>
|
|
Set the attribute "repeater" for an FHZ device to 1 to ignore events
|
|
received from a FS20 repeater. In fact we are not sure that they are
|
|
repeater messages, we just ignore messages which were sent out by our
|
|
device for the next 3 seconds (see the next attribute)
|
|
</li><br>
|
|
|
|
<a name="skip_next"></a>
|
|
<li>skip_next<br>
|
|
Can be applied to at devices.<br>
|
|
Used for at commands: skip the execution of the command the next
|
|
time.</li><br>
|
|
|
|
<a name="softbuffer"></a>
|
|
<li>softbuffer<br />
|
|
Can be applied to FHZ devices.<br />
|
|
As the FHZ command buffer for FHT devices is limited, and commands
|
|
are only sent to the FHT devices every 150 seconds, the hardware
|
|
buffer may overflow and FHT commands get lost. Setting this attribute
|
|
to 1 implements an "unlimited" software buffer<br>
|
|
Default is disabled (i.e. not set or set to 0).</li><br>
|
|
|
|
<a name="retrycount"></a>
|
|
<li>retrycount<br />
|
|
Can be applied to FHT devices.<br />
|
|
If the <a href="#softbuffer">softbuffer</a> attribute is set, then
|
|
resend commands <code>retrycount</code> times if after 240 seconds
|
|
no confirmation message is rececived from the corresponding FHT
|
|
device.<br>
|
|
Default is 3.</li><br>
|
|
</li>
|
|
</ul>
|
|
|
|
Examples:
|
|
<ul>
|
|
<code>attr global verbose 3</code><br>
|
|
<code>attr lamp room kitchen</code><br>
|
|
<code>attr lamp dummy</code><br>
|
|
<code>attr lamp loglevel 6</code><br />
|
|
<br>
|
|
<code>attr FHZ softbuffer 0 # disable the softbuffer for FHT devices</code><br />
|
|
<code>attr FHZ softrepeat 300 # resend failed commands to FHT devices after 300 seconds </code><br />
|
|
<code>attr FHZ softmaxretry 4 # stop resending failed commands to FHT devices after 4 retries.</code> </ul>
|
|
<br>
|
|
|
|
Notes:<br>
|
|
<ul>
|
|
<li>See <a href="#delattr">delattr</a> to delete attributes.</li>
|
|
</ul>
|
|
</ul>
|
|
|
|
<a name="defattr"></a>
|
|
<h3>defattr</h3>
|
|
<ul>
|
|
<code>defattr [<attrname> [<value>]] </code><br>
|
|
|
|
<br>Set the default attribute. Each device defined from now on will receive
|
|
this attribute (see the <a href="#attr">attr</a> entry for details on
|
|
attribute names and values).<br>
|
|
If no attrname is specified, then the default attribute list will be deleted.
|
|
<br><br>
|
|
|
|
Example to set the attribute "room kitchen" and "loglevel 4" to
|
|
each of the lamps:
|
|
<ul>
|
|
<code>defattr room kitchen</code><br>
|
|
<code>defattr loglevel 4</code><br>
|
|
<code>define lamp1 FS20 1234 11</code><br>
|
|
<code>define lamp2 FS20 1234 12</code><br>
|
|
<code>define lamp3 FS20 1234 13</code><br>
|
|
<code>defattr</code><br>
|
|
</ul>
|
|
<br>
|
|
|
|
Notes:<br>
|
|
<ul>
|
|
<li>There is no way to delete a single default-attribute from the list</li>
|
|
</ul>
|
|
</ul>
|
|
|
|
|
|
|
|
<a name="define"></a>
|
|
<h3>define</h3>
|
|
<ul>
|
|
<code>define <name> <type> <type-specific></code><br>
|
|
<br>
|
|
Define a device. You need devices if you want to manipulate them (e.g.
|
|
set on/off), and the logfile is also more readable if it contains e.g.
|
|
"lamp off" instead of "Device 5673, Button 00, Code 00 (off)". <br>
|
|
Use "define <name> ?" to get a list of possible types.
|
|
<br>
|
|
|
|
<a name="FHZ"></a>
|
|
<h4>Type FHZ</h4>
|
|
<ul>
|
|
<code>define <name> FHZ <serial-device></code> <br>
|
|
<br>
|
|
Specifies the serial port to communicate with the FHZ 1000 PC. The name(s)
|
|
of the serial-device(s) depends on your distribution. The program can
|
|
service multiple devices, FS20 and FHT device commands will be sent out
|
|
through the last FHZ device defined before the definition of the FS20/FHT
|
|
device. To change the association, use the <a href="#set">set</a> command
|
|
activefor. <b>Important:</b> this definition must occur after the
|
|
modpath command but before any other (FHZ related) device definition,
|
|
else you'll see "no I/O device found" messages.<br>
|
|
If the serial-device is called none, then no device will be opened, so you
|
|
can experiment without hardware attached.<br>
|
|
|
|
Set the attribute "repeater" for this device to 1 to ignore events received
|
|
from a FS20 repeater. In fact we are not sure that they are repeater
|
|
messages, we just ignore messages which were sent out by our device for the
|
|
next 3 seconds (or configured otherwise by filtertimeout).
|
|
<br>
|
|
For GNU/Linux you may want to read our <a href="linux.html">hints for
|
|
GNU/Linux</a> about <a href="linux.html#multipledevices">multiple USB
|
|
devices</a>.<br>
|
|
|
|
<b>Note:</b>The firmware of the FHZ1x00 will drop commands if the airtime
|
|
for the last hour would exceed 1% (which corresponds roughly to 163
|
|
commands). For this purpose there is a command counter for the last hour
|
|
(see list FHZDEVICE), which triggers with "TRANSMIT LIMIT EXCEEDED" if
|
|
there were more than 163 commands in the last hour.<br>
|
|
|
|
</ul>
|
|
<br>
|
|
|
|
<a name="FS20"></a>
|
|
<h4>Type FS20</h4>
|
|
<ul>
|
|
<code>define <name> FS20 <housecode> <button>
|
|
[fg <fgaddr>] [lm <lmaddr>] [gm FF] </code>
|
|
<br><br>
|
|
|
|
The values of housecode, button, fg, lm, and gm can be either defined as
|
|
hexadecimal value or as ELV-like "quad-decimal" value with digits 1-4. We
|
|
will reference this ELV-like notation as ELV4 later in this document. You
|
|
may even mix both hexadecimal and ELV4 notations, because FHEM can detect
|
|
the used notation automatically by counting the digits.<br>
|
|
|
|
<ul>
|
|
<li><code><housecode></code> is a 4 digit hex or 8 digit ELV4 number,
|
|
corresponding to the housecode address.</li>
|
|
<li><code><button></code> is a 2 digit hex or 4 digit ELV4 number,
|
|
corresponding to a button of the transmitter.</li>
|
|
<li>The optional <code><fgaddr></code> specifies the function group.
|
|
It is a 2 digit hex or 4 digit ELV address. The first digit of the hex
|
|
adress must be F or the first 2 digits of the ELV4 address must be
|
|
44.</li>
|
|
<li>The optional <code><lmaddr></code> specifies the local
|
|
master. It is a 2 digit hex or 4 digit ELV address. The last digit of the
|
|
hex address must be F or the last 2 digits of the ELV4 address must be
|
|
44.</li>
|
|
<li>The optional gm specifies the global master, the adress must be FF if
|
|
defined as hex value or 4444 if defined as ELV4 value.</li>
|
|
</ul>
|
|
<br>
|
|
|
|
Examples:
|
|
<ul>
|
|
<code>define lamp FS20 7777 00 fg F1 gm F</code><br>
|
|
<code>define roll1 FS20 7777 01</code><br>
|
|
<code>define otherlamp FS20 24242424 1111 fg 4412 gm 4444</code><br>
|
|
<code>define otherroll1 FS20 24242424 1114</code>
|
|
</ul>
|
|
</ul>
|
|
<br>
|
|
|
|
<a name="FHT"></a>
|
|
<h4>Type FHT</h4>
|
|
<ul>
|
|
<code>define <name> FHT <housecode></code>
|
|
<br><br>
|
|
|
|
<code><housecode></code> is a four digit hex number,
|
|
corresponding to the adress of the FHT80b device.
|
|
<br>
|
|
|
|
Examples:
|
|
<ul>
|
|
<code>define wz FHT 3232</code><br>
|
|
</ul>
|
|
<br>
|
|
See the section <a href="#set">set</a> for more.
|
|
</ul>
|
|
<br>
|
|
|
|
<a name="HMS"></a>
|
|
<h4>Type HMS</h4>
|
|
<ul>
|
|
<code>define <name> HMS <housecode></code>
|
|
<br><br>
|
|
|
|
<code><housecode></code> is a four digit hex number,
|
|
corresponding to the adress of the HMS device.
|
|
<br>
|
|
|
|
Examples:
|
|
<ul>
|
|
<code>define temp HMS 1234</code><br>
|
|
</ul>
|
|
Notes:<br>
|
|
<ul>
|
|
<li>There is _NO_ guarantee that the code will work as expected in all
|
|
circumstances, the authors are not liable for any damage occuring as a
|
|
result of incomplete or buggy code</li>
|
|
|
|
<li>Currently supported devices are the HMS100T, HMS100TF, HMS100WD and
|
|
the RM100-2.</li>
|
|
|
|
<li>The housecode of the HMS devices may change if the battery is renewed.
|
|
In order to make life easier, you can define a "wildcard" device for each
|
|
type of HMS device. First the real device-id will be checked, then the
|
|
wildcard device id. The wildcards are:
|
|
<ul>
|
|
<li>1000 for the HMS100TF</li>
|
|
<li>1001 for the HMS100T</li>
|
|
<li>1002 for the HMS100WD</li>
|
|
<li>1003 for the RM100-2</li>
|
|
<li>1006 for the HMS100MG</li>
|
|
</ul>
|
|
</li>
|
|
|
|
<li>Some battery low notifications are not yet implemented (RM100, HMS100WD).</li>
|
|
<li>Please test your installation before relying on the functionality.</li>
|
|
</ul>
|
|
<br>
|
|
</ul>
|
|
<br>
|
|
|
|
<a name="KS300"></a>
|
|
<h4>Type KS300</h4>
|
|
<ul>
|
|
<code>define <name> KS300 <housecode> [ml/raincounter [wind-factor]]</code>
|
|
<br><br>
|
|
|
|
<code><housecode></code> is a four digit hex number,
|
|
corresponding to the adress of the KS300 device, right now it is ignored.
|
|
The ml/raincounter defaults to 255 ml, but it must be specified if you wish
|
|
to set the wind factor, which defaults to 1.0.
|
|
|
|
<br>
|
|
|
|
Examples:
|
|
<ul>
|
|
<code>define ks1 KS300 1234</code><br>
|
|
</ul>
|
|
<br>
|
|
</ul>
|
|
<br>
|
|
|
|
<a name="WS300"></a>
|
|
<h4>Type WS300</h4>
|
|
<ul>
|
|
<code>define WS300Device WS300 <serial device></code><br>
|
|
or<br>
|
|
<code>define <devname> WS300 [0-9]</code><br>
|
|
<br>
|
|
The first line is mandatory if you have a WS300 device: it defines the
|
|
input device with its USB port. The name of this device is fixed and must
|
|
be WS300Device. It must be the first defined WS300 device.<br>
|
|
|
|
For each additional device (with number 0 to 9) you have to define another
|
|
WS300 device, with an arbitrary name. The WS300 device which reports the
|
|
readings will be defined with the port number 9, an optional KS300 with the
|
|
port number 8.<br><br>
|
|
|
|
Examples:
|
|
<pre>
|
|
define WS300Device WS300 /dev/ttyUSB1
|
|
define ash2200.1 WS300 0
|
|
define ks300 WS300 8
|
|
define ws300 WS300 9
|
|
</pre>
|
|
</ul>
|
|
<br>
|
|
|
|
<a name="EM"></a>
|
|
<h4>Type EM</h4>
|
|
<ul>
|
|
<code>define <name> EM <em1010pc-device></code>
|
|
<br><br>
|
|
|
|
Define a EM1010PC USB device. From the software point of view there should
|
|
be no problems if you attach/define more than one EM1010PC, but it is
|
|
unknown if the low-level radio protocol supports this.<br> Currently there
|
|
is no way to read the internal log of the EM1010PC, use the program
|
|
em1010.pl in the contrib directory for this purpose.<br><br>
|
|
|
|
Examples:
|
|
<ul>
|
|
<code>define em EM /dev/elv_em1010pc</code><br>
|
|
</ul>
|
|
<br>
|
|
</ul>
|
|
|
|
<a name="EMWZ"></a>
|
|
<h4>Type EMWZ</h4>
|
|
<ul>
|
|
<code>define <name> EMWZ <device-number></code>
|
|
<br><br>
|
|
|
|
Define up to 4 EM1000WZ attached to the EM1010PC. The device number must
|
|
be between 1 and 4 (else you have a differnt device connected to the
|
|
EM1010PC). Defining an EMWZ will schedule an internal task, which reads the
|
|
status of the device every 5 minutes, and triggers notify/filelog commands.
|
|
<br><br>
|
|
|
|
Example:
|
|
<ul>
|
|
<code>define emwz EMWZ 1</code><br>
|
|
</ul>
|
|
<br>
|
|
</ul>
|
|
|
|
<a name="EMEM"></a>
|
|
<h4>Type EMEM</h4>
|
|
<ul>
|
|
<code>define <name> EMEM <device-number></code>
|
|
<br><br>
|
|
|
|
Define up to 4 EM1000EM attached to the EM1010PC. The device number must
|
|
be between 5 and 8.
|
|
Defining an EMEM will schedule an internal task, which reads the
|
|
status of the device every 5 minutes, and triggers notify/filelog commands.
|
|
<br>Note: Currently this device does not support a "set" function.
|
|
<br><br>
|
|
|
|
Example:
|
|
<ul>
|
|
<code>define emem EMEM 5</code><br>
|
|
</ul>
|
|
<br>
|
|
</ul>
|
|
|
|
<a name="EMGZ"></a>
|
|
<h4>Type EMGZ</h4>
|
|
<ul>
|
|
<code>define <name> EMGZ <device-number></code>
|
|
<br><br>
|
|
|
|
Define up to 4 EM1000GZ attached to the EM1010PC. The device number must
|
|
be 9.
|
|
Defining an EMGZ will schedule an internal task, which reads the
|
|
status of the device every 5 minutes, and triggers notify/filelog commands.
|
|
<br><br>
|
|
|
|
Example:
|
|
<ul>
|
|
<code>define emgz EMGZ 9</code><br>
|
|
</ul>
|
|
<br>
|
|
</ul>
|
|
|
|
|
|
<a name="M232"></a>
|
|
<h4>Type M232</h4>
|
|
<ul>
|
|
<code>define <name> M232 <m232-device></code>
|
|
<br><br>
|
|
|
|
Define a M232 device. You can attach as many M232 devices as you like. A
|
|
M232 device provides 6 analog inputs (voltage 0..5V with 10 bit resolution)
|
|
and 8 bidirectional digital ports. The eighth digital port can be used as a
|
|
16 bit counter (maximum frequency 3kHz). The M232 device needs to be
|
|
connected to a 25pin sub-d RS232 serial port. A USB-to-serial converter
|
|
works fine if no serial port is available.<br><br>
|
|
|
|
Examples:
|
|
<ul>
|
|
<code>define m232 M232 /dev/ttyUSB2</code><br>
|
|
</ul>
|
|
<br>
|
|
</ul>
|
|
|
|
<a name="M232Counter"></a>
|
|
<h4>Type M232Counter</h4>
|
|
<ul>
|
|
<code>define <name> M232Counter [unit [factor]]</code>
|
|
<br><br>
|
|
|
|
Define at most one M232Counter for a M232 device. Defining a M232Counter
|
|
will schedule an internal task, which reads the status of the counter every
|
|
minute, and triggers notify/filelog commands. <code>unit</code> is the unit
|
|
name, <code>factor</code> is used to calculate the reading of the counter
|
|
from number of ticks. <br><br> <br>Note: the unit defaults to the string
|
|
"ticks", but it must be specified if you wish to set the factor, which
|
|
defaults to 1.0. In the second example below one tick equals 1/1250th kWh.
|
|
Do not forget to start the counter (with <code>set .. start</code> for
|
|
M232) or to start the counter and set the reading to a specified value
|
|
(with <code>set ... value</code> for M232Counter). <br><br>
|
|
Example:
|
|
<ul>
|
|
<code>define counter M232Counter turns</code><br>
|
|
<code>define counter M232Counter kWh 0.0008</code><br>
|
|
</ul>
|
|
<br>
|
|
</ul>
|
|
|
|
|
|
<a name="SCIVT"></a>
|
|
<h4>Type SCIVT</h4>
|
|
<ul>
|
|
<code>define <name> SCIVT <SCD-device></code>
|
|
<br><br>
|
|
|
|
Define a SCD series solar controler device. Details see <a
|
|
href="http://english.ivt-hirschau.de/content.php?parent_id=CAT_64&doc_id=DOC_118">here</a>.
|
|
You probably need a Serial to USB controller like the PL2303.
|
|
<br>
|
|
Defining an SCIVT device will schedule an internal task, which reads the
|
|
status of the device every 5 minutes, and triggers notify/filelog commands.
|
|
<br>Note: Currently this device does not support a "set" function, only
|
|
a single get function which reads the device status immediately.
|
|
<br><br>
|
|
|
|
Example:
|
|
<ul>
|
|
<code>define scd SCIVT /dev/ttyUSB2</code><br>
|
|
</ul>
|
|
<br>
|
|
</ul>
|
|
|
|
<a name="FileLog"></a>
|
|
<h4>Type FileLog</h4>
|
|
<ul>
|
|
<code>define <name> FileLog <filename> <regexp></code>
|
|
<br><br>
|
|
|
|
Log events to <code><filename></code>. The log format is
|
|
<pre>
|
|
YYYY:MM:DD_HH:MM:SS <device> <event></pre>
|
|
The regexp will be checked against the (complete!) device name
|
|
or against the (complete!) devicename:event combination.
|
|
<br>
|
|
<code><filename></code> may contain one or more of the following
|
|
wildcards (a subset of the Unix date command arguments):
|
|
<ul>
|
|
<li><code>%d</code> day of month (01..31)</li>
|
|
<li><code>%m</code> month (01..12)</li>
|
|
<li><code>%Y</code> year (1970...)
|
|
<li><code>%w</code> day of week (0..6); 0 represents Sunday
|
|
<li><code>%j</code> day of year (001..366)
|
|
<li><code>%U</code> week number of year with Sunday as first day of week (00..53)
|
|
<li><code>%V</code> week number of year with Monday as first day of week (01..53)
|
|
</ul>
|
|
|
|
Examples:
|
|
<ul>
|
|
<code>define lamplog FileLog /var/tmp/lamp.log lamp</code><br>
|
|
<code>define wzlog FileLog /var/tmp/wz-%Y-%U.log
|
|
wz:(measured-temp|actuator).*</code><br>
|
|
</ul>
|
|
<br>
|
|
</ul>
|
|
|
|
<a name="at"></a>
|
|
<h4>Type at</h4>
|
|
<ul>
|
|
<code>define <name> at <timespec> <command></code><br>
|
|
<br>
|
|
Start an arbitrary fhem.pl command at a later time.<br>
|
|
<code><timespec></code> format: [+][*{N}]<timedet><br>
|
|
<ul>
|
|
The optional <code>+</code> indicates that the specification is
|
|
<i>relative</i>(i.e. it will be added to the current time).<br>
|
|
The optional <code>*</code> indicates that the command should be
|
|
executed <i>repeatedly</i>.<br>
|
|
The optional <code>{N}</code> after the * indicates,that the command
|
|
should be repeated <i>N-times</i> only.<br>
|
|
<timedet> is either HH:MM, HH:MM:SS or {perlfunc()}, where perlfunc
|
|
must return a HH:MM or HH:MM:SS date.
|
|
</ul>
|
|
<br>
|
|
|
|
Examples:
|
|
<PRE>
|
|
# absolute ones:
|
|
define a1 at 17:00:00 set lamp on # fhem command
|
|
define a2 at 17:00:00 { Log 1, "Teetime" } # Perl command
|
|
define a3 at 17:00:00 "/bin/echo "Teetime" > /dev/console" # shell command
|
|
define a4 at *17:00:00 set lamp on # every day
|
|
|
|
# relative ones
|
|
define a5 at +00:00:10 set lamp on # switch the lamp on in 10 seconds
|
|
define a6 at +00:00:02 set lamp on-for-timer 1 # Blink once in 2 seconds
|
|
define a7 at +*{3}00:00:02 set lamp on-for-timer 1 # Blink 3 times
|
|
|
|
# Blink 3 times if the piri sends a command
|
|
define n1 notify piri:on.* define a8 at +*{3}00:00:02 set lamp on-for-timer 1
|
|
|
|
# Switch the lamp on from sunset to 11 PM
|
|
# Copy 99_SUNRISE_EL.pm in the FHEM directory to have sunset_rel()
|
|
{ sunrise_coord("8.686", "50.112", "") }
|
|
define a9 at +*{sunset_rel()} set lamp on
|
|
define a10 at *23:00:00 set lamp off
|
|
|
|
# More elegant version, works for sunset > 23:00 too
|
|
define a11 at +*{sunset_rel()} set lamp on-till 23:00
|
|
|
|
# Only do this on weekend
|
|
define a12 at +*{sunset_rel()} { fhem("set lamp on-till 23:00") if($we) }
|
|
|
|
# Switch lamp1 and lamp2 on from 7:00 till 10 minutes after sunrise
|
|
define a13 at *07:00 set lamp1,lamp2 on-till {sunrise_abs(+600)}
|
|
|
|
# Switch the lamp off 2 minutes after sunrise each day
|
|
define a14 at +*{sunrise_rel(+120)} set lamp on
|
|
</PRE>
|
|
|
|
Notes:<br>
|
|
<ul>
|
|
<li>if no <code>*</code> is specified, then a command will be executed
|
|
only once, and then the <code>at</code> entry will be deleted. In
|
|
this case the command will be saved to the statefile (as it
|
|
considered volatile, i.e. entered by cronjob) and not to the
|
|
configfile (see the <a href="#save">save</a> command.)
|
|
</li>
|
|
|
|
<li>if the current time is greater then the time specified, then the
|
|
command will be executed tomorrow. This is why the relative forms
|
|
of the sunset/sunrise functions should be used with the relative
|
|
(+) flag</li>
|
|
|
|
<li>In order to use the sunrise_rel()/sunset_rel() functions, copy the
|
|
99_SUNRISE_EL.pm file from the contrib into the modules (FHEM)
|
|
directory, and put { sunrise_coord(long, lat, "") } into your
|
|
<a href="#lastinclude">lastinclude</a> file, as in the above example.
|
|
If you are not using sunrise_coord, then the coordinates for
|
|
Frankfurt am Main, Germany will be used.
|
|
</li>
|
|
|
|
<li>For even more complex date handling you either have to call fhem from
|
|
cron or filter the date in a perl expression, see the last example and
|
|
the section <a href="#perl">Perl special</a>.
|
|
</li>
|
|
</ul>
|
|
<br>
|
|
</ul>
|
|
|
|
<a name="notify"></a>
|
|
<h4>Type notify</h4>
|
|
<ul>
|
|
<code>define <name> notify <pattern> <command></code>
|
|
<br><br>
|
|
Execute a command when received an event for the <a
|
|
|
|
href="#define">definition</a> <code><pattern></code>. If
|
|
<command> is enclosed in {}, then it is a perl expression, if it is
|
|
enclosed in "", then it is a shell command, else it is a "plain" fhem.pl
|
|
command (chain). See the <a href="#trigger">trigger</a> command for
|
|
testing it.
|
|
|
|
Examples:
|
|
<ul>
|
|
<code>define b3lampV1 notify btn3 set lamp %</code><br>
|
|
<code>define b3lampV2 notify btn3 { fhem "set lamp %" }</code><br>
|
|
<code>define b3lampV3 notify btn3 "/usr/local/bin/setlamp "%""</code><br>
|
|
<code>define b3lampV3 notify btn3 set lamp1 %;;set lamp2 %</code><br>
|
|
<code>define wzMessLg notify wz:measured.* "/usr/local/bin/logfht @ "%""</code><br>
|
|
<code>define LogHToDB notify .*H:.* {DbLog("@","%")}</code><br>
|
|
<code>define LogUndef notify UNDEFINED "send-me-mail.sh "%""</code><br>
|
|
</ul>
|
|
<br>
|
|
|
|
Notes:
|
|
<ul>
|
|
<li>The character <code>%</code> will be replaced with the received event,
|
|
e.g. with <code>on</code> or <code>off</code> or <code>measured-temp: 21.7
|
|
(Celsius)</code><br> It is advisable to put the <code>%</code> into double
|
|
quotes, else the shell may get a syntax error.<br>
|
|
To use % or @ in the text itself, use the double mode (%% or @@)</li>
|
|
|
|
<li>The character <code>@</code> will be replaced with the device
|
|
name.</li>
|
|
|
|
<li><code><pattern></code> may also be a compound of
|
|
<code>definition:event</code> to filter for events.</li>
|
|
|
|
<li><code><pattern></code> must completely (!)
|
|
match either the device name, or the compound of the device name and the
|
|
event. The event is either the string you see in the <a
|
|
href="#list">list</a> output in paranthesis after the device name, or the
|
|
string you see when you do a detailed list of the device.</li>
|
|
|
|
<li>To use database logging, copy the file contrib/91_DbLog.p into your
|
|
modules directory, and change the $dbconn parameter in the file.</li>
|
|
|
|
<li>Each undefined device (FS20, HMS, FHT) will be reported with the
|
|
device name "UNDEFINED". The % parameter will contain the type (FS20,
|
|
HMS100T, etc) and device number, separated by a space.</li>
|
|
|
|
</ul>
|
|
</ul>
|
|
|
|
<a name="weblink"></a>
|
|
<h4>Type weblink</h4>
|
|
<ul>
|
|
<code>define <name> weblink [link|fileplot] <argument></code>
|
|
<br><br>
|
|
This is a placeholder used with webpgm2 to be able to integrate links
|
|
into it, and to be able to put more than one gnuplot picture on one page.
|
|
It has no set or get methods.
|
|
|
|
Examples:
|
|
<ul>
|
|
<code>define wl_1 weblink link http://www.fhem.de</code><br>
|
|
<code>define wl_2 weblink fileplot <logdevice>:<gnuplot-file>:<logfile></code><br>
|
|
</ul>
|
|
<br>
|
|
|
|
Notes:
|
|
<ul>
|
|
<li>Normally you won't have to define fileplot weblinks manually, as
|
|
fhemweb.pl (webpgm2) makes it easy for you, just plot a logfile (see
|
|
<a href="#logtype">logtype</a>) and convert it to weblink. Now you
|
|
can group these weblinks by putting them into rooms. If you convert
|
|
the current logfile to a weblink, it will always refer to the current
|
|
file (and not the one you originally specified).</li>
|
|
<li>The <b>99_weblink.pm</b> module is in the contrib directory, you have
|
|
to "install" it manually by copying it into the FHEM directory. </li>
|
|
</ul>
|
|
</ul>
|
|
|
|
<a name="dummy"></a>
|
|
<h4>Type dummy</h4>
|
|
<ul>
|
|
<code>define <name> dummy</code>
|
|
<br><br>
|
|
|
|
Define a dummy. A dummy can take via <a href="#set">set</a> any values.
|
|
Used for programming.
|
|
Example:
|
|
<ul>
|
|
<code>define myvar dummy</code><br>
|
|
<code>set myvar 7</code><br>
|
|
</ul>
|
|
Notes:
|
|
<ul>
|
|
<li>The <b>99_dummy.pm</b> module is in the contrib directory, you have
|
|
to "install" it manually by copying it into the FHEM directory.</li>
|
|
</ul>>
|
|
</ul>
|
|
|
|
</ul>
|
|
|
|
|
|
<a name="delattr"></a>
|
|
<h3>delattr</h3>
|
|
<ul>
|
|
<code>delattr <name> [<attrname>]</code> <br>
|
|
<br>
|
|
Delete either a single attribute (see the <a href="#attr">attr</a> command)
|
|
or all attributes for a device (if no <attrname> is defined).<br>
|
|
|
|
Examples:
|
|
<ul>
|
|
<code>delattr lamp follow-on-for-timer</code><br>
|
|
<code>delattr lamp</code><br>
|
|
</ul>
|
|
<br>
|
|
</ul>
|
|
|
|
<a name="delete"></a>
|
|
<h3>delete</h3>
|
|
<ul>
|
|
<code>delete <name></code> <br>
|
|
<br>
|
|
Delete something created with the <a href="#define">define</a> command.
|
|
<br>
|
|
Examples:
|
|
<ul>
|
|
<code>delete lamp</code><br>
|
|
</ul>
|
|
<br>
|
|
</ul>
|
|
|
|
<a name="get"></a>
|
|
<h3>get</h3>
|
|
<ul>
|
|
<code>get <name> <type-specific></code>
|
|
<br><br>
|
|
Ask a value directly from the device, and wait for an answer. In general, you
|
|
can get a list of possible commands by<br><code>get <device> ?</code>
|
|
<br>
|
|
Right now only the FHZ module supports this function.
|
|
|
|
<h4>Type FHZ:</h4>
|
|
<ul>
|
|
<code>get FHZ <value></code>
|
|
<br><br>
|
|
where <code>value</code> is one of:<br>
|
|
<pre>
|
|
init1
|
|
init2
|
|
init3
|
|
serial
|
|
fhtbuf</pre>
|
|
Notes:
|
|
<ul>
|
|
<li>The mentioned codes are needed for initializing the FHZ1X00</li>
|
|
<li>The answer for a command is also displayed by <code>list FHZ</code>
|
|
</li>
|
|
<li>
|
|
The FHZ1000PC has a message buffer for the FHT, as it
|
|
only can send messages to it every 2 (or so) minutes. If the buffer
|
|
is full, then newly issued ones will be dropped. <code>fhtbuf</code>
|
|
returns the free memory in this buffer (in hex), my maximum is 2c (42
|
|
bytes).</code></li>
|
|
</ul>
|
|
</ul>
|
|
|
|
<h4>Type EM:</h4>
|
|
<ul>
|
|
<code>get EM <value></code>
|
|
<br><br>
|
|
where <code>value</code> is either version or time.
|
|
</ul>
|
|
|
|
<h4>Type EMWZ:</h4>
|
|
<ul>
|
|
<code>get EMWZ status</code>
|
|
<br><br>
|
|
This is the same command which is scheduled every 5 minutes internally.
|
|
</ul>
|
|
|
|
<h4>Type M232:</h4>
|
|
<ul>
|
|
<code>get <name> [an0..an5]</code>
|
|
<br><br>
|
|
Gets the reading of analog input 0..5 in volts.
|
|
<br><br>
|
|
<code>get <name> [io0..io7]</code>
|
|
<br><br>
|
|
Gets the state of digital ports 0..7, result is 0 or 1.
|
|
<br><br>
|
|
<code>get <name> octet</code>
|
|
<br><br>
|
|
Gets the state of all digital ports at once, result is 0..255.
|
|
<br><br>
|
|
<code>get <name> counter</code>
|
|
<br><br>
|
|
Gets the number of ticks of the counter since the last reset. The counter
|
|
wraps around from 65535 to 0.
|
|
<br><br>
|
|
</ul>
|
|
|
|
<h4>Type M232Counter:</h4>
|
|
<ul>
|
|
<code>get <name> status</code>
|
|
<br><br>
|
|
Gets the reading of the counter multiplied by the factor from the
|
|
<code>define</code> statement. Wraparounds of the counter are accounted for
|
|
by an offset (see reading <code>basis</code> in the output of the
|
|
<code>list</code> statement for the device).
|
|
<br><br>
|
|
</ul>
|
|
|
|
</ul>
|
|
|
|
|
|
<a name="include"></a>
|
|
<h3>include</h3>
|
|
<ul>
|
|
<code>include <filename></code> <br>
|
|
<br>
|
|
Read in the file, and process every line as a fhem command. Makes
|
|
configuration files more modular and enables to reread them.
|
|
<br>
|
|
</ul>
|
|
|
|
<a name="inform"></a>
|
|
<h3>inform</h3>
|
|
<ul>
|
|
<code>inform [on|off]</code> <br>
|
|
<br>
|
|
If set to on, and a device state changes, send a notification to the current
|
|
client. This command can be used by other programs/modules to receive a
|
|
notification.
|
|
<br>
|
|
</ul>
|
|
|
|
<a name="list"></a>
|
|
<h3>list</h3>
|
|
<ul>
|
|
<code>list [name]</code>
|
|
<br><br>
|
|
Output a list of all definitions, all notify settings and all at
|
|
entries. This is one of the few commands which return a string in a
|
|
normal case.
|
|
<br><br>
|
|
Example:
|
|
<pre><code> FHZ> list
|
|
|
|
Type list <name> for detailed info.
|
|
|
|
Internal:
|
|
global (Internal)
|
|
|
|
FHZ:
|
|
FHZ (fhtbuf: 23)
|
|
|
|
FS20:
|
|
Btn4 (on-old-for-timer)
|
|
Roll1 (on)
|
|
Stehlampe (off)
|
|
|
|
FHT:
|
|
fl (measured-temp: 21.1 (Celsius))
|
|
|
|
KS300:
|
|
out1 (T: 2.9 H: 74 W: 2.2 R: 8.2 IR: no)
|
|
|
|
at:
|
|
at_rollup (Next: 07:00:00)
|
|
|
|
notify:
|
|
ntfy_btn4 (active)
|
|
|
|
FileLog:
|
|
avglog (active)
|
|
|
|
</code></pre>
|
|
If specifying <code>name</code>, then a detailed status for <code>name</code>
|
|
will be displayed, e.g.:
|
|
<pre><code> FHZ> list fl
|
|
|
|
Internals:
|
|
CODE 5102
|
|
DEF 5102
|
|
NAME fl
|
|
NR 15
|
|
STATE measured-temp: 21.1 (Celsius)
|
|
TYPE FHT
|
|
IODev FHZ
|
|
Attributes:
|
|
room Heizung
|
|
Readings:
|
|
2006-11-02 09:45:56 actuator 19%
|
|
2006-10-28 15:10:58 code_0000aa 17
|
|
2006-10-07 10:52:09 code_0000ba 0
|
|
2006-11-02 10:40:08 code_4b004b 0
|
|
2006-11-02 08:24:46 code_7e0067 0
|
|
2006-11-02 04:13:35 day-temp 21.0 (Celsius)
|
|
2006-11-02 06:03:37 desired-temp 21.0 (Celsius)
|
|
2006-11-02 04:13:31 fri-from1 06:00
|
|
2006-11-02 04:13:31 fri-to1 23:50
|
|
2006-11-02 04:11:30 init 255
|
|
2006-11-02 04:13:36 lowtemp-offset 2.0 (Celsius)
|
|
2006-11-02 10:40:06 measured-high 0
|
|
2006-11-02 10:40:06 measured-low 211
|
|
2006-11-02 10:40:06 measured-temp 21.1 (Celsius)
|
|
2006-11-02 04:13:39 mode auto
|
|
2006-11-02 04:13:25 mon-from1 06:00
|
|
2006-11-02 04:13:25 mon-to1 23:00
|
|
2006-11-02 04:13:35 night-temp 18.0 (Celsius)
|
|
2006-11-02 04:13:32 sat-from1 08:00
|
|
2006-11-02 04:13:33 sat-to1 23:50
|
|
2006-11-02 04:13:34 sun-from1 08:00
|
|
2006-11-02 04:13:34 sun-to1 23:00
|
|
2006-11-02 04:13:29 thu-from1 06:00
|
|
2006-11-02 04:13:29 thu-to1 23:00
|
|
2006-11-02 04:13:26 tue-from1 06:00
|
|
2006-11-02 04:13:26 tue-to1 23:00
|
|
2006-11-02 10:40:07 warnings Battery low
|
|
2006-11-02 04:13:27 wed-from1 06:00
|
|
2006-11-02 04:13:28 wed-to1 23:00
|
|
2006-11-02 04:13:36 windowopen-temp 12.0 (Celsius)
|
|
Send buffer:<br /> 2007-10-19 00:31:24 desired-temp 22.5
|
|
2007-10-19 00:33:20 mode auto<br />
|
|
</code></pre>
|
|
</ul>
|
|
|
|
|
|
<a name="modify"></a>
|
|
<h3>modify</h3>
|
|
<ul>
|
|
<code>modify <name> <type-dependent-options></code>
|
|
<br><br>
|
|
|
|
Used to modify some definitions. Useful for changing some <a
|
|
href="#at">at</a> or <a href="#notify">notify</a> definitions. If specifying
|
|
one argument to an at type deinition, only the time part will be changed. In
|
|
case of a notify type definition, only the regex part will be changed. All
|
|
other values (state, attributes, etc) will remain intact.
|
|
<br><br>
|
|
Example:
|
|
<ul>
|
|
<code>define lampon at 19:00 set lamp on</code><br>
|
|
<code>modify lampon *19:00</code><br>
|
|
<code>modify lampon 19:00 set lamp on-for-timer 16</code><br>
|
|
</ul>
|
|
</ul>
|
|
|
|
<a name="quit"></a>
|
|
<h3>quit</h3>
|
|
<ul>
|
|
<code>quit</code>
|
|
<br><br>
|
|
If used in a TCP/IP session, terminate the client session.<br>
|
|
If used in a script, terminate the parsing of the current script.
|
|
<br><br>
|
|
Example:
|
|
<ul>
|
|
<code>quit</code>
|
|
</ul>
|
|
</ul>
|
|
|
|
|
|
<a name="reload"></a>
|
|
<h3>reload</h3>
|
|
<ul>
|
|
<code>reload <module></code>
|
|
<br><br>
|
|
Reload the given module from the module directory. Mainly intended to reload
|
|
the 99_PRIV file (or equivalent) in order to test perl-scripts.
|
|
<br><br>
|
|
Example:
|
|
<ul>
|
|
<code>reload 99_PRIV</code>
|
|
</ul>
|
|
</ul>
|
|
|
|
<a name="rereadcfg"></a>
|
|
<h3>rereadcfg</h3>
|
|
<ul>
|
|
<code>rereadcfg</code>
|
|
<br><br>
|
|
Re-read the configuration file.
|
|
Note: The statefile will be saved first, then the config file will be read
|
|
(all devices will be initialized again), and at last the statefile will be reloaded again.
|
|
<br><br>
|
|
Example:
|
|
<ul>
|
|
<code>rereadcfg</code>
|
|
</ul>
|
|
</ul>
|
|
|
|
<a name="save"></a>
|
|
<h3>save</h3>
|
|
<ul>
|
|
<code>save [<configfile>]</code>
|
|
<br><br>
|
|
Save first the <a href="#statefile">statefile</a>, then the
|
|
<a href="#configfile">configfile</a> information. If a parameter is specified,
|
|
it will be used instead the global configfile attribute.<br><br>
|
|
Notes:
|
|
<ul>
|
|
<li>save only writes out definitions and attributes, but no commands
|
|
which were previously part of the config file. Put such commands in the
|
|
<a href="#lastinclude">lastinclude</a> file.
|
|
</ul>
|
|
</ul>
|
|
|
|
|
|
<a name="set"></a>
|
|
<h3>set</h3>
|
|
<ul>
|
|
<code>set <name> <type-specific></code>
|
|
<br><br>
|
|
Set parameters of a device / send signals to a device. You can
|
|
get a list of possible commands by<br><code>set <name> ?</code>
|
|
<br>
|
|
Instead of <name> you can also use an enumeration (separated by comma)
|
|
or ranges (separated by -), see the FS20 examples.
|
|
|
|
<a name="FHZset"></a>
|
|
<h4>Type FHZ:</h4>
|
|
<ul>
|
|
<code>set FHZ <variable> [<value>]</code>
|
|
<br><br>
|
|
where <code>value</code> is one of:<br>
|
|
<pre>
|
|
initFS20
|
|
initHMS
|
|
time
|
|
FHTcode
|
|
activefor
|
|
raw</pre>
|
|
Notes:
|
|
<ul>
|
|
<li>use activefor if you have multiple FHZ devices, and you want to
|
|
change the association of an FS20 or FHT device (i.e. which device will
|
|
send out the messages).</li>
|
|
<li>raw is used to send out "raw" FS20/FHT messages. See the doc
|
|
directory for some examples</li>
|
|
<li>In order to set the time of your FHT's, schedule this command every
|
|
minute:<br>
|
|
<code>define fhz_timer at +*00:01:00 set FHZ time</code><br>
|
|
See the <a href="#loglevel">loglevel</a> to prevent logging of
|
|
this command.
|
|
</li>
|
|
<li>FHTcode is a two digit hex number (from 00 to 63?) and sets the
|
|
central FHT code, which is used by the FHT devices. After changing
|
|
it, you <b>must</b> reprogram each FHT80b with: PROG (until Sond
|
|
appears), then select CEnt, Prog, Select nA.</li>
|
|
</ul>
|
|
</ul>
|
|
|
|
|
|
<a name="FH20set"></a>
|
|
<h4>Type FS20:</h4>
|
|
<ul>
|
|
<code>set <name> <value> [<time>]</code>
|
|
<br><br>
|
|
where <code>value</code> is one of:<br>
|
|
<pre>
|
|
dim06%
|
|
dim12%
|
|
dim18%
|
|
dim25%
|
|
dim31%
|
|
dim37%
|
|
dim43%
|
|
dim50%
|
|
dim56%
|
|
dim62%
|
|
dim68%
|
|
dim75%
|
|
dim81%
|
|
dim87%
|
|
dim93%
|
|
dim100%
|
|
dimdown
|
|
dimup
|
|
dimupdown
|
|
off
|
|
off-for-timer
|
|
on # dimmer: set to value before switching it off
|
|
on-for-timer # see the note
|
|
on-old-for-timer # set to previous (before switching it on)
|
|
ramp-on-time # time to reach the desired dim value on dimmers
|
|
ramp-off-time # time to reach the off state on dimmers
|
|
reset
|
|
sendstate
|
|
timer
|
|
toggle # between off and previous dim val
|
|
on-till # Special, see the note
|
|
</pre>
|
|
|
|
Examples:
|
|
<ul>
|
|
<code>set lamp on</code><br>
|
|
<code>set lamp1,lamp2,lamp3 on</code><br>
|
|
<code>set lamp1-lamp3 on</code><br>
|
|
<code>set lamp on-for-timer 12</code><br>
|
|
</ul>
|
|
<br>
|
|
Notes:
|
|
<ul>
|
|
<li>Use reset with care: the device forgets even the housecode.
|
|
</li>
|
|
<li>As the FS20 protocol needs about 0.22 seconds to transmit a
|
|
sequence, a pause of 0.22 seconds is inserted after each command.
|
|
</li>
|
|
<li>The FS20ST switches on for dim*%, dimup. It does not respond to
|
|
sendstate.</li>
|
|
<li>If the timer is set (i.e. it is not 0) then on, dim*,
|
|
and *-for-timer will take it into account (at least by the FS20ST).
|
|
</li>
|
|
<li>The <code>time</code> argument ranges from 0.25sec to 4 hours and
|
|
16 minutes.
|
|
As the time is encoded in one byte there are only 112 distinct
|
|
values, the resolution gets coarse with larger values. The program
|
|
will report the used timeout if the specified one cannot be set
|
|
exactly. The resolution is 0.25 sec from 0 to 4 sec, 0.5 sec from 4
|
|
to 8 sec, 1 sec from 8 to 16 sec and so on. If you need better
|
|
precision for large values, use <a href="#at">at</a> which has a 1
|
|
sec resolution.</li>
|
|
<li>If the attribute follow-on-for-timer is set for the device and the
|
|
on-for-timer command is sent to the device with a time parameter,
|
|
the program automatically schedules a "setstate off" for the
|
|
specified time.</li>
|
|
<li>on-till requires an absolute time in the "at" format (HH:MM:SS, HH:MM
|
|
or {<perl-code>}, where the perl-code returns a time specification).
|
|
If the current time is greater then the specified time, then the
|
|
command is ignored, else an "on" command is generated, and for the
|
|
given "till-time" an off command is scheduleld via the at command.
|
|
</li>
|
|
</ul>
|
|
</ul>
|
|
|
|
|
|
<a name="FHTset"></a>
|
|
<h4>Type FHT:</h4>
|
|
<ul>
|
|
<code>set <name> <valuetype> <value></code>
|
|
<br><br>
|
|
where <code>value</code> is one of:<br>
|
|
<pre>
|
|
mon-from1
|
|
mon-to1
|
|
mon-from2
|
|
mon-to2
|
|
tue-from1
|
|
tue-to1
|
|
tue-from2
|
|
tue-to2
|
|
wed-from1
|
|
wed-to1
|
|
wed-from2
|
|
wed-to2
|
|
thu-from1
|
|
thu-to1
|
|
thu-from2
|
|
thu-to2
|
|
fri-from1
|
|
fri-to1
|
|
fri-from2
|
|
fri-to2
|
|
sat-from1
|
|
sat-to1
|
|
sat-from2
|
|
sat-to2
|
|
sun-from1
|
|
sun-to1
|
|
sun-from2
|
|
sun-to2
|
|
mode
|
|
holiday1
|
|
holiday2
|
|
desired-temp
|
|
day-temp
|
|
night-temp
|
|
year
|
|
month
|
|
day
|
|
hour
|
|
minute
|
|
refreshvalues
|
|
lowtemp-offset
|
|
</pre>
|
|
Notes:
|
|
<ul>
|
|
<li>All <code>*-temp</code> values need a temperature
|
|
as argument, which will be rounded to 0.5 Celsius.<br />
|
|
Temperature values
|
|
must between 5.5 and 30.5 Celsius. Value 5.5 set the actuator to OFF, value 30.5 set the actuator to ON </li>
|
|
<li><code>mode</code> is one of <code>auto, manual, holiday or
|
|
holiday_short.<br>If the mode is holiday, then
|
|
<ul>
|
|
<li>holiday1 sets the end-day of the holiday</li>
|
|
<li>holiday2 sets the end-month of the holiday</li>
|
|
</ul>
|
|
For holiday_short
|
|
<ul>
|
|
<li>holiday1 sets the time, in 10-minute steps</li>
|
|
<li>holiday2 sets number of days from now on.</li>
|
|
</ul>
|
|
</li>
|
|
<li>The <code>*-from1/*-from2/*-to1/*-to2</code> valuetypes need a time
|
|
spec as argument in the HH:MM format. They define the periods, where
|
|
the day-temp is valid. The minute (MM) will be rounded to 10, and
|
|
24:00 means off.</li>
|
|
<li><code>refreshvalues</code> does not need an argument, but sends a
|
|
plea to the FHT device, so it may send its parameters. If you want
|
|
to get these values regularly, then schedule:<br>
|
|
<code>at +*01:00:00 set <name> refreshvalues</code></li>
|
|
<li><code>lowtemp-offset</code> need a temperature
|
|
as argument, which will be rounded to 1.0 Celsius.<br />
|
|
Temperature values must between 1.0 and 5.0 Celsius.<br />
|
|
The
|
|
<code>lowtemp-offset</code> is used for temperature warning (to low temperature in a room within more than 1,5 hours after the last desired-temp changing). The low temperatur warning it relates to the actual desired temperature.<br>
|
|
</li>
|
|
<li>The FHT is very economical (or lazy), it receives messages from the
|
|
FHZ1x00 every 2 minutes (or so). Don't be surprized if your command
|
|
is accepted 10 minutes later by the device. See the related
|
|
<code>fhtbuf</code> entry in the <code><a href="#get">get</a></code>
|
|
section.<br />
|
|
<li>For FHT devices, FHEM have an internal software buffer for sending commands step by step. This buffer should prevent lost commands. In case of transmission failures FHEM tries to resend commands. You can see the queued unsent and the failed commands with the <a href="#list">list</a> command. If a command don't picked up from a FHT device within a <a href="#softrepeat">given time</a>, the command sends again until <a href="#softmaxretry">softmaxretry</a> reached. <br />
|
|
<li>To prevent long time waiting for sending important command, there is a priority list. Commands send in this importance:<br />
|
|
<code>desired-temp, mode, refreshvalues,holiday1,holiday2,day-temp,night-temp, [all other commands]</code> <br />
|
|
<br />
|
|
</ul>
|
|
</ul>
|
|
|
|
<a name="WS300set"></a>
|
|
<h4>Type WS300:</h4>
|
|
<ul>
|
|
<code>set WS300Device <interval(min.)> <height(m)> <rainvalume(ml)></code>
|
|
<br><br>
|
|
Set some WS300 configuration parameters.
|
|
</ul>
|
|
|
|
<a name="EMWZset"></a>
|
|
<h4>Type EMWZ:</h4>
|
|
<ul>
|
|
<code>set EMWZdevice <param> <value></code><br><br>
|
|
where param is one of:
|
|
<ul>
|
|
<li>rperkw<br>
|
|
Number of rotations for a KiloWatt of the EM1000WZ device (actually
|
|
of the device where the EM1000WZ is attached to). Without setting
|
|
this correctly, all other readings will be incorrect.
|
|
<li>alarm<br>
|
|
Alarm in WATT. if you forget to set it, the default value is
|
|
rediculously low (random), and if a value above this threshold is
|
|
received, the EM1010PC will start beeping once every minute. It can
|
|
be very annoying.
|
|
<li>price<br>
|
|
The price of one KW in EURO (use e.g. 0.20 for 20 Cents). It is used
|
|
only on the EM1010PC display, it is of no interest for FHEM.
|
|
</ul>
|
|
</ul>
|
|
|
|
<h4>Type M232:</h4>
|
|
<ul>
|
|
<code>set <name> stop</code>
|
|
<br><br>
|
|
Stops the counter.
|
|
<br><br>
|
|
<code>set <name> start</code>
|
|
<br><br>
|
|
Resets the counter to zero and starts it.
|
|
<br><br>
|
|
<code>set <name> octet <value></code>
|
|
<br><br>
|
|
Sets the state of all digital ports at once, value is 0..255.
|
|
<br><br>
|
|
<code>set <name> [io0..io7] 0|1</code>
|
|
<br><br>
|
|
Turns digital port 0..7 off or on.
|
|
<br><br>
|
|
</ul>
|
|
|
|
<h4>Type M232Counter:</h4>
|
|
<ul>
|
|
<code>set <name> value <value></code>
|
|
<br><br>
|
|
Sets the reading of the counter to the given value. The counter is reset
|
|
and started and the offset is adjusted to value/unit.
|
|
<br><br>
|
|
</ul>
|
|
|
|
|
|
</ul>
|
|
|
|
|
|
<a name="setstate"></a>
|
|
<h3>setstate</h3>
|
|
<ul>
|
|
<code>setstate <name> <value></code>
|
|
<br><br>
|
|
Set the "STATE" for <code><name></code> as shown in paranthesis in the
|
|
<a href="#list">list</a> command
|
|
to <code><value></code> without sending any signals to the device
|
|
itself. This command is also used in the <a href="#statefile">statefile</a>.
|
|
<br><br>
|
|
Examples:
|
|
<ul>
|
|
<pre>
|
|
setstate lamp on
|
|
</ul>
|
|
<br>
|
|
Note:
|
|
<ul>
|
|
<li>The statefile uses another version of this command, don't be surprised.
|
|
</li>
|
|
</ul>
|
|
</ul>
|
|
|
|
|
|
<a name="shutdown"></a>
|
|
<h3>shutdown</h3>
|
|
<ul>
|
|
<code>shutdown</code>
|
|
<br><br>
|
|
Shut down the server (after saving the <a href="#statefile">state information
|
|
</a>)
|
|
<br><br>
|
|
Example:
|
|
<ul>
|
|
<code>shutdown</code>
|
|
</ul>
|
|
</ul>
|
|
|
|
|
|
<a name="trigger"></a>
|
|
<h3>trigger</h3>
|
|
<ul>
|
|
<code>trigger <dev> <state></code>
|
|
<br><br>
|
|
Trigger a <a href="#notify">notify</a> definition.
|
|
<br><br>
|
|
Example:
|
|
<ul>
|
|
<code>trigger btn3 on</code>
|
|
</ul>
|
|
</ul>
|
|
|
|
<a name="sleep"></a>
|
|
<h3>sleep</h3>
|
|
<ul>
|
|
<code>sleep <sec></code>
|
|
<br><br>
|
|
Sleep for a given amount, millisecond accuracy.
|
|
<br><br>
|
|
Example:
|
|
<ul>
|
|
<code>sleep 0.5</code><br>
|
|
<code>notify btn3 set lamp toggle;;sleep 0.5;;set lamp toggle</code>
|
|
</ul>
|
|
<br>
|
|
Note: As the server is <b>not</b> multithreaded, everything is blocked for
|
|
the given amount.<br>
|
|
|
|
</ul>
|
|
|
|
|
|
<a name="xmllist"></a>
|
|
<h3>xmllist</h3>
|
|
<ul>
|
|
<code>xmllist</code>
|
|
<br><br>
|
|
Returns an XML tree of all definitions, all notify settings and all at
|
|
entries. It is not intended for human consumption.
|
|
<br><br>
|
|
Example:
|
|
<pre> FHZ> xmllist
|
|
<FHZINFO>
|
|
<internal_LIST>
|
|
<internal name="global" state="internal" sets="" attrs="room configfile logfile modpath pidfilename port statefile userattr verbose version">
|
|
<INT key="DEF" value="<no definition>"/>
|
|
<INT key="NR" value="0"/>
|
|
<INT key="STATE" value="internal"/>
|
|
[...]
|
|
|
|
</pre>
|
|
</ul>
|
|
|
|
|
|
<a name="perl"></a>
|
|
<h3>Perl specials</h3>
|
|
<ul>
|
|
<li>To use fhem commands from the perl expression, use the function "fhem",
|
|
which takes a string argument, this string will be evaluated as an fhem
|
|
command chain.<br>
|
|
Example:
|
|
<ul>
|
|
define n1 notify piri:on { fhem "set light on" }
|
|
</ul>
|
|
</li>
|
|
<li>
|
|
To make date and time handling easier, before evaluating a perl expression
|
|
the variables $sec, $min, $hour, $mday, $month, $year, $wday, $yday, $isdst
|
|
are set (see perldoc -f localtime), with the exception that $month is in the
|
|
range of 1 to 12, and $year is also corrected by 1900 (as one would normally
|
|
expect). Additionally $we is 1 if it is weekend (i.e $wday == 0 ||
|
|
$wday == 6), and 0 otherwise.
|
|
Example:
|
|
<ul>
|
|
define n2 notify piri:on { if($hour > 18 || $hour < 5) { fhem "set light on" } }
|
|
</ul>
|
|
|
|
</li>
|
|
|
|
<li>
|
|
<b>Note</b>: do not forget to escape the semicolon (;) with two semicolons
|
|
(;;), else your perl code will be interpreted as an fhem command and you
|
|
most certainly get syntax errors.
|
|
</li>
|
|
|
|
<li>
|
|
The current value (the string you see in paranthesis in the output of the
|
|
list command) is available in the <code>value</code> hash; to access it
|
|
use $value{<devicename>}<br>
|
|
If you need the old value (and time) of the currently triggered device,
|
|
then you can access it with <code>$oldvalue{$dev}{TIME}</code> and
|
|
<code>$oldvalue{$dev}{VAL}</code>.<br>
|
|
</li>
|
|
|
|
<li>
|
|
To access the numerical value of an FS20 command (e.g. toggle), use the
|
|
hash <code>fs20_c2b</code>. E.g. { Log 2, $fs20_c2b{"toggle"} }
|
|
</li>
|
|
|
|
<li>
|
|
If you add the 99_SUNRISE_EL.pm from the contrib directory to your module
|
|
directory, then you have access to the following functions: <br>
|
|
<ul>
|
|
sunset_rel()<br>
|
|
sunset_abs()<br>
|
|
sunrise_rel()<br>
|
|
sunrise_abs()<br>
|
|
isday()<br>
|
|
</ul>
|
|
The _rel functions should be used as "at" spec, and the _abs functions as
|
|
argument to the on-till argument of the set command.<br>
|
|
isday returns 1 if the sun is visible, and 0 else.
|
|
</li>
|
|
|
|
</ul>
|
|
|
|
</body>
|
|