*** HMCCU - Module for FHEM - Homematic CCU integration ***
=============================================================
------------------------------------
Content:
------------------------------------
1 HMCCU Introduction
1.1 HMCCU Description
1.2 HMCCU Requirements
2 HMCCU Usage
2.1 HMCCU Set Commands
2.2 HMCCU Get Commands
2.3 HMCCU Attributes
2.4 HMCCU Parameter File
3 Executing FHEM commands on CCU
------------------------------------
1 HMCCU Introduction
------------------------------------
------------------------------------
1.1 HMCCU Description
------------------------------------
The modules HMCCU and HMCCUDEV provide a simple interface between FHEM and
a Homematic CCU2. HMCCU is the IO device for the communication with the CCU.
HMCCUDEV is used to define client devices.
The states and values of CCU devices and variables are not updated automatically
in FHEM. You have to define an AT device to ensure a continuous update of CCU
values in FHEM.
------------------------------------
1.2 HMCCU Requirements
------------------------------------
The module HMCCU requires the XML-API CCU addon (version >= 1.10). The FHEM
module requires the package XML::Simple. Note: not all HMCCU commands use the
XML-API.
------------------------------------
2 HMCCU Usage
------------------------------------
Define a new IO device for communication with Homematic CCU:
define <name> HMCCU <hostname_or_IP>
The only parameter is the name or the IP address of the Homematic CCU. All
other adjustments are done by setting attributes.
------------------------------------
2.1 HMCCU Set commands
------------------------------------
If attribute 'stateval' is set the specified string substitutions are applied
before setting the device state, a variable or a datapoint value. This is
important because CCU states are often 'true' or 'false' while in FHEM one like
to use 'on' or 'off'. So setting 'stateval' to 'on:true,off:false' will ensure
that FHEM commands 'on' and 'off' are replaced by 'true' and 'false' before
transmitting them to the CCU.
The commands markes with a '*' don't use the XML-API of the CCU.
Set state of a CCU device (*):
set <name> devstate <ccudev>:<channel> <value> [...]
Parameter <ccudev> is the name of a device in CCU. <channel> specifies a
CCU device channel number. If more than one <value> is specified the
values are concatinated by blanks to one value.
Set value of a CCU device datapoint (*):
set <name> datapoint <ccudev>:<channel>.<datapoint> <value> [...]
Parameters are the same as with 'devstate' command. In addition the name
of a CCU device datapoint must be specified.
Set value of a CCU system variable (*):
set <name> var <variable> <value> [...]
The variable must exist in CCU. It's not created automatically.
Execute CCU program:
set <name> execute <program>
The program is executed even it's deactivated in CCU.
Clear CCU alarms:
set <name> clearmsg
------------------------------------
2.2 HMCCU Get commands
------------------------------------
If attribute 'ccureadings' is set to 1 (default) the results of the get
commands are stored in readings. The reading names correspond to the CCU
datapoints, including device and channel. The format of the reading names
is device:channel.datapoint.
If attribute 'ccureadings' is set to 0 the results of the get commands
are displayed in the browser window. No readings will be set in this case.
Some get commands allow an optional parameter <reading>. If this parameter
is specified the CCU value is stored using this reading name.
With attribute 'substitute' you can define expressions which are substituted
by strings before CCU values are stored in readings. For example if CCU
reports device states as 'true' or 'false' these values can be replaced with
'open' or 'closed' by setting 'substitute' to 'true:open,false:closed'.
The attribute 'substitute' is ignored if the same attribute is defined
in a client device.
Get values of channel datapoints:
get <name> channel <channel>[.<datapoint_exp>]
If datapoint is not specified all datapoints will be read. The
command accepts a regular expression as parameter datapoint.
Get value of datapoint (*):
get <name> datapoint <ccudevice>:<channel>.<datapoint> [<reading>]
Get state of channel (*):
get <name> devstate <ccudevice>:<channel> [<reading>]
Specified channel must contain a datapoint 'STATE'.
Get multiple devices / channels / datapoints:
get <name> parfile [<parfile>]
If attribute 'parfile' is set parameter <parfile> can be omitted.
See parameter file description below.
Get CCU variable values:
get <name> vars <varname_exp>
Variable name can be a regular expression. Variables are stored
as readings with same name as in CCU.
------------------------------------
2.3 HMCCU Attributes
------------------------------------
Control reading creation (default is 1):
attr <name> ccureadings { 0 | 1 }
Remove character from CCU device or variable specification in set
commands:
attr <name> stripchar <character>
If a variable name ends with the specified character this
character will be removed.
Specify name of parameter file for command 'get parfile':
attr <name> parfile <parfile>
Specify text substitutions for values in set commands:
attr <name> stateval <text1>:<subtext1>[,...]
Specify text substitutions for values returned by get commands:
attr <name> substitute <regexp1>:<text1>[,...]
------------------------------------
2.4 HMCCU Parameter files
------------------------------------
A parameter file contain a list of CCU device channel or datapoint
definitions. Each line can contain a text substitution rule. A parameter
file is used by command 'get parfile'.
The format of a parfile entry is:
<ccudevice>:<channel>[.<datapoint_exp>] [<regexp1>:<subtext1>[,...]]
Empty lines and lines starting with a '#' are ignored.
------------------------------------
3 Executing FHEM commands on CCU
------------------------------------
It's possible to execute FHEM commands from CCU via the FHEM telnet port.
The following shell script encapsulates the necessary commands. It can
be placed somewhere under /etc/config/addons directory in CCU. The script
requires the installation of the netcat command (nc) on CCU (search for
the binary in google and install it somewhere in /etc/config/addons).
--- Script ---
#!/bin/sh
# Set name or IP address and port of FHEM server
FHEM_SERVER="myfhem"
FHEM_PORT=7072
# Set path to nc command
NCCMD="/etc/config/addons/scripts"
if [ $# -ne 1 ]; then
echo "Usage: $0 Command"
exit 1
fi
echo -e "$1\nquit\n" | $NCCMD/nc $FHEM_SERVER $FHEM_PORT
--- End of script ---
The script should be called from a CCU program by using the CUXD exec object.
If FHEM command contains blanks it should be enclosed in double quotes.
*** Have fun! zap ***