*** HMCCU - Module for FHEM - Homematic CCU integration ***
|
|
=============================================================
|
|
|
|
|
|
------------------------------------
|
|
Content:
|
|
------------------------------------
|
|
|
|
1 HMCCU Introduction
|
|
1.1 HMCCU Description
|
|
1.2 HMCCU Requirements
|
|
|
|
2 HMCCU Usage
|
|
2.1 HMCCU Set Commands
|
|
2.2 HMCCU Get Commands
|
|
2.3 HMCCU Attributes
|
|
2.4 HMCCU Parameter File
|
|
|
|
3 Executing FHEM commands on CCU
|
|
|
|
|
|
------------------------------------
|
|
1 HMCCU Introduction
|
|
------------------------------------
|
|
------------------------------------
|
|
1.1 HMCCU Description
|
|
------------------------------------
|
|
|
|
The modules HMCCU and HMCCUDEV provide a simple interface between FHEM and
|
|
a Homematic CCU2. HMCCU is the IO device for the communication with the CCU.
|
|
HMCCUDEV is used to define client devices.
|
|
The states and values of CCU devices and variables are not updated automatically
|
|
in FHEM. You have to define an AT device to ensure a continuous update of CCU
|
|
values in FHEM.
|
|
|
|
------------------------------------
|
|
1.2 HMCCU Requirements
|
|
------------------------------------
|
|
|
|
The module HMCCU requires the XML-API CCU addon (version >= 1.10). The FHEM
|
|
module requires the package XML::Simple. Note: not all HMCCU commands use the
|
|
XML-API.
|
|
|
|
|
|
------------------------------------
|
|
2 HMCCU Usage
|
|
------------------------------------
|
|
|
|
Define a new IO device for communication with Homematic CCU:
|
|
|
|
define <name> HMCCU <hostname_or_IP>
|
|
|
|
The only parameter is the name or the IP address of the Homematic CCU. All
|
|
other adjustments are done by setting attributes.
|
|
|
|
------------------------------------
|
|
2.1 HMCCU Set commands
|
|
------------------------------------
|
|
|
|
If attribute 'stateval' is set the specified string substitutions are applied
|
|
before setting the device state, a variable or a datapoint value. This is
|
|
important because CCU states are often 'true' or 'false' while in FHEM one like
|
|
to use 'on' or 'off'. So setting 'stateval' to 'on:true,off:false' will ensure
|
|
that FHEM commands 'on' and 'off' are replaced by 'true' and 'false' before
|
|
transmitting them to the CCU.
|
|
The commands markes with a '*' don't use the XML-API of the CCU.
|
|
|
|
Set state of a CCU device (*):
|
|
|
|
set <name> devstate <ccudev>:<channel> <value> [...]
|
|
|
|
Parameter <ccudev> is the name of a device in CCU. <channel> specifies a
|
|
CCU device channel number. If more than one <value> is specified the
|
|
values are concatinated by blanks to one value.
|
|
|
|
Set value of a CCU device datapoint (*):
|
|
|
|
set <name> datapoint <ccudev>:<channel>.<datapoint> <value> [...]
|
|
|
|
Parameters are the same as with 'devstate' command. In addition the name
|
|
of a CCU device datapoint must be specified.
|
|
|
|
Set value of a CCU system variable (*):
|
|
|
|
set <name> var <variable> <value> [...]
|
|
|
|
The variable must exist in CCU. It's not created automatically.
|
|
|
|
Execute CCU program:
|
|
|
|
set <name> execute <program>
|
|
|
|
The program is executed even it's deactivated in CCU.
|
|
|
|
Clear CCU alarms:
|
|
|
|
set <name> clearmsg
|
|
|
|
|
|
------------------------------------
|
|
2.2 HMCCU Get commands
|
|
------------------------------------
|
|
|
|
If attribute 'ccureadings' is set to 1 (default) the results of the get
|
|
commands are stored in readings. The reading names correspond to the CCU
|
|
datapoints, including device and channel. The format of the reading names
|
|
is device:channel.datapoint.
|
|
If attribute 'ccureadings' is set to 0 the results of the get commands
|
|
are displayed in the browser window. No readings will be set in this case.
|
|
Some get commands allow an optional parameter <reading>. If this parameter
|
|
is specified the CCU value is stored using this reading name.
|
|
With attribute 'substitute' you can define expressions which are substituted
|
|
by strings before CCU values are stored in readings. For example if CCU
|
|
reports device states as 'true' or 'false' these values can be replaced with
|
|
'open' or 'closed' by setting 'substitute' to 'true:open,false:closed'.
|
|
The attribute 'substitute' is ignored if the same attribute is defined
|
|
in a client device.
|
|
|
|
Get values of channel datapoints:
|
|
|
|
get <name> channel <channel>[.<datapoint_exp>]
|
|
|
|
If datapoint is not specified all datapoints will be read. The
|
|
command accepts a regular expression as parameter datapoint.
|
|
|
|
Get value of datapoint (*):
|
|
|
|
get <name> datapoint <ccudevice>:<channel>.<datapoint> [<reading>]
|
|
|
|
Get state of channel (*):
|
|
|
|
get <name> devstate <ccudevice>:<channel> [<reading>]
|
|
|
|
Specified channel must contain a datapoint 'STATE'.
|
|
|
|
Get multiple devices / channels / datapoints:
|
|
|
|
get <name> parfile [<parfile>]
|
|
|
|
If attribute 'parfile' is set parameter <parfile> can be omitted.
|
|
See parameter file description below.
|
|
|
|
Get CCU variable values:
|
|
|
|
get <name> vars <varname_exp>
|
|
|
|
Variable name can be a regular expression. Variables are stored
|
|
as readings with same name as in CCU.
|
|
|
|
|
|
------------------------------------
|
|
2.3 HMCCU Attributes
|
|
------------------------------------
|
|
|
|
Control reading creation (default is 1):
|
|
|
|
attr <name> ccureadings { 0 | 1 }
|
|
|
|
Remove character from CCU device or variable specification in set
|
|
commands:
|
|
|
|
attr <name> stripchar <character>
|
|
|
|
If a variable name ends with the specified character this
|
|
character will be removed.
|
|
|
|
Specify name of parameter file for command 'get parfile':
|
|
|
|
attr <name> parfile <parfile>
|
|
|
|
Specify text substitutions for values in set commands:
|
|
|
|
attr <name> stateval <text1>:<subtext1>[,...]
|
|
|
|
Specify text substitutions for values returned by get commands:
|
|
|
|
attr <name> substitute <regexp1>:<text1>[,...]
|
|
|
|
|
|
------------------------------------
|
|
2.4 HMCCU Parameter files
|
|
------------------------------------
|
|
|
|
A parameter file contain a list of CCU device channel or datapoint
|
|
definitions. Each line can contain a text substitution rule. A parameter
|
|
file is used by command 'get parfile'.
|
|
The format of a parfile entry is:
|
|
|
|
<ccudevice>:<channel>[.<datapoint_exp>] [<regexp1>:<subtext1>[,...]]
|
|
|
|
Empty lines and lines starting with a '#' are ignored.
|
|
|
|
|
|
------------------------------------
|
|
3 Executing FHEM commands on CCU
|
|
------------------------------------
|
|
|
|
It's possible to execute FHEM commands from CCU via the FHEM telnet port.
|
|
The following shell script encapsulates the necessary commands. It can
|
|
be placed somewhere under /etc/config/addons directory in CCU. The script
|
|
requires the installation of the netcat command (nc) on CCU (search for
|
|
the binary in google and install it somewhere in /etc/config/addons).
|
|
|
|
--- Script ---
|
|
#!/bin/sh
|
|
|
|
# Set name or IP address and port of FHEM server
|
|
FHEM_SERVER="myfhem"
|
|
FHEM_PORT=7072
|
|
|
|
# Set path to nc command
|
|
NCCMD="/etc/config/addons/scripts"
|
|
|
|
if [ $# -ne 1 ]; then
|
|
echo "Usage: $0 Command"
|
|
exit 1
|
|
fi
|
|
|
|
echo -e "$1\nquit\n" | $NCCMD/nc $FHEM_SERVER $FHEM_PORT
|
|
|
|
--- End of script ---
|
|
|
|
The script should be called from a CCU program by using the CUXD exec object.
|
|
If FHEM command contains blanks it should be enclosed in double quotes.
|
|
|
|
|
|
*** Have fun! zap ***
|
|
|