Startup ------- 1a PUT C9 - 02 01 1F 64 1.st fhz1000: C9 - 01 02 1F 02 78 05 5C 24 FF 2.nd fhz1000: C9 - 01 02 1F 02 78 05 5C 24 FF 3.rd fhz1000: C9 - 01 02 1F 02 78 05 5C 0A FF 1b PUT C9 - 02 01 1F 0A 4.th fhz1000: C9 - 01 02 1F 02 78 07 B6 22 80 1c PUT C9 - 02 01 1F 60 C9 - 01 02 1F 02 78 07 1C 22 80 2 PUT 04 - C9 01 84 57 02 08 1.st fhz1000: C9 - 01 02 84 01 08 05 FF 13 6E 21 BC 4B 1B # Serial no: 136E21BC (?) 3.rd fhz1000: C9 - 01 02 84 01 08 05 FF 13 6E 29 0E 51 18 # Serial no: 136E290E (?) 3 PUT: 04 - C9 01 86 PUT: 04 - C9 01 96 PUT: C9 - 02 01 61 04 0C 10 12 0A # Set Date to 2004-12-16 14:10 Switching FS20 device on / off ------------------------------ PUT: 04 - 020101 - HHHH BT VL HHHH: Transmitter (Hauscode) BT: Button VL: Values: 00 => off, 01 => dim06%, 02 => dim12%, 03 => dim18%, 04 => dim25%, 05 => dim31%, 06 => dim37%, 07 => dim43%, 08 => dim50%, 09 => dim56%, 0A => dim62%, 0B => dim68%, 0C => dim75%, 0D => dim81%, 0E => dim87%, 0F => dim93%, 10 => dim100%, 11 => on, # Set to previous dim value (before switching it off) 12 => toggle, # between off and previous dim val 13 => dimup, 14 => dimdown, 15 => dimupdown, 16 => timer, 17 => sendstate, 18 => off-for-timer, 19 => on-for-timer, 1a => on-old-for-timer, 1b => reset, The FSST20 switches on for dim*. When setting bit 6 (counted from 1) in the value, you can also send a further byte, the time as suggested in snippet_6. The FS20ST only respects this for the values timer, off-for-timer, on-for-timer If the timer is set, then it works for dim*, on, *-for-timer sendstate does not work for the FS20ST =================================