# # Example configuration for module HMCCU # # Define device (hostname of CCU is "homematic") define d_ccu HMCCU homematic # Generate readings for values read from CCU attr d_ccu ccureadings 1 # Parameterfile with channel/datapoints to be read from CCU # by command get parfile attr d_ccu parfile /opt/fhem/scripts/hmvalues.pat # If CCU systemvariable name ends with a ":" this character # will be removed. Applies to command set devstate only. # Helpful if CCU variable should be set as a reaction on an # event. attr d_ccu stripchar : # Substitute values read from CCU before storing them in a # reading. attr d_ccu substitute false:closed,true:open # Do not append units to values read from CCU attr d_ccu units 0