stylesheetPrefix, menuEntries added, Extend devStateIcon, js setting of attr
values in detail screen, live slider update in detail and room view
git-svn-id: https://svn.fhem.de/fhem/trunk@2786 2b470e98-0d58-463d-a4d8-8e2adae1ed80
- contains ExtJS Library 4.1.1a, together with css and images
- is related to the module 93_DbLog.pm, which holds some functions used by the frontend
git-svn-id: https://svn.fhem.de/fhem/trunk@2767 2b470e98-0d58-463d-a4d8-8e2adae1ed80
00_MAXLAN.pm: update doc
10_MAX.pm: update doc
00_MAXLAN.pm: Fix syntax error
00_MAXLAN.pm: remove reference to hmId
00_MAXLAN.pm: also dispatch define events from metadata, because shutter does not have configdata
10_MAX.pm: allow setting temp to "on" and "off"
10_MAX.pm: fix doc formatting
00_MAXLAN.pm: Add two set commands: raw and clock
00_MAXLAN.pm: parse current until time
00_MAXLAN.pm: send quit in Undef
00_MAXLAN.pm: beautifying
Display ctrl mode (auto/manual/temporary)
Allow setting a temporary temperature
MAX: change event delimiter to handle time
Fix bug where only one room could be handled
MAX: parse "S:" response
List roomid, send correct roomid with desired-temp
MAX: show roomname for devices
MAX: add troubleshooting when device send temperature 0
00_MAXLAN: Fix parsing of "until" date: time and month were broken
00_MAXLAN: show time offset on start
Show more state info
Set timezone to floating because local cannot be determined on fritzbox
dispatch CubeClockState only if rfaddr is known
Read valve position of HeatingThermostat by gaggi (g.sturm@sturm-busse.de)
MAX: notify if 1% percent rule is oversteped and if queue is full
Do not crash on empty Metadata response
change inital label from "initalized" to "waiting for data"
Auto reconnect if connecting failed
defer setting clock until after complete hello
cleanup
Lower polling interval to 10 seconds
Remove ReadyFn, we already got a FD
really defer setting the clock
valveposition is in percent
rename serialNr to serial
check for matching magic/version, be more robust while parsing metadata
implement SendMetadata
Add missing devices during C: response
Fill SetRoomId
Make ReadAnswer really wait for one
Make valveposition a reading/show possible settings in WebUI (by wollet42, wton1@gmx.de)
Remove DateTime module
rename room to group: fhem already has a room concept
Set temperature individually, not for the whole group
Implement setting of groupid
Remove display of groupname, it does not say anything
generate events for HeatingThermostat's readings
Switched to ReadingsBulkUpdate (thanks to tobias.faust, tobias.faust@gmx.net)
Implement interfaces: this changes the setter desired-temp to desiredTemperature
Correct some Log messages
doc: make clear that MAXLAN uses the cube exclusively
Fix webinterface showing old name for desiredTemperature
add temp4valve4.gplot for Max! HeatingThermostats
Move SetTemperature to backend, allow eco/comfort
Show eco/comfort temperature from device
Support event-on-{update,change}-reading
Correct computation of time difference (thanks Andy Fuchs)
gplot: Corrected axis range
Allow configuring of a lot of device parameters
Add optional pollintervall to define (thanks to wollet42)
Return message up to UI
Minor fixes
Fix setting desiredTemperature
Allow cancel of pairmode
gplot: better scaling (by wollet42) and steps instead of interpolation
Continue even if L: is empty
add factoryReset
request config after new device paired
Updated CUL_MAX
Correct parsing of flags
parse measured(!) temperature
Unify logic for MAXLAN and CUL_MAX into MAX
Show some unused bits
Correctly show until time only in temporary mode
Fix measured temp
Fix checks for existance
Return list of valid values for desiredTemperature
Require a value with desiredTemperature and don't show (manual)
Update doc text
Update CUL_MAX
MAXLAN: dispatch define before configuration event
Update plot to show measured temperature, too
git-svn-id: https://svn.fhem.de/fhem/trunk@2144 2b470e98-0d58-463d-a4d8-8e2adae1ed80
Critics:
- the smile of the new one is weird
- the house was not a complete one