mirror of
https://github.com/fhem/fhem-mirror.git
synced 2025-03-09 20:57:11 +00:00
30_HUEBridge: added set inactive/active commands, create event for lastError reading
git-svn-id: https://svn.fhem.de/fhem/trunk@15123 2b470e98-0d58-463d-a4d8-8e2adae1ed80
This commit is contained in:
parent
3782465fa0
commit
fe83da85ad
@ -1,5 +1,7 @@
|
||||
# Add changes at the top of the list. Keep it in ASCII, and 80-char wide.
|
||||
# Do not insert empty lines here, update check depends on it.
|
||||
- changed: 30_HUEBridge: added set inactive/active commands
|
||||
create event for lastError reading
|
||||
- change: 93_DbLog: V2.22.6 commandref revised
|
||||
- new: 73_UpsPico: New module for UpsPico UPS from pimodules
|
||||
- feature: LightScene: added traversalOrder attribute
|
||||
|
@ -139,7 +139,7 @@ HUEBridge_Notify($$)
|
||||
return if(!grep(m/^INITIALIZED|REREADCFG$/, @{$dev->{CHANGED}}));
|
||||
|
||||
if( IsDisabled($name) > 0 ) {
|
||||
readingsSingleUpdate($hash, 'state', 'disabled', 1 ) if( ReadingsVal($name,'state','' ) ne 'disabled' );
|
||||
readingsSingleUpdate($hash, 'state', 'inactive', 1 ) if( ReadingsVal($name,'inactive','' ) ne 'disabled' );
|
||||
return undef;
|
||||
}
|
||||
|
||||
@ -624,9 +624,19 @@ HUEBridge_Set($@)
|
||||
|
||||
return undef;
|
||||
|
||||
} elsif($cmd eq 'active') {
|
||||
return "can't activate disabled bridge." if(AttrVal($name, "disable", undef));
|
||||
|
||||
readingsSingleUpdate($hash, 'state', 'active', 1 );
|
||||
HUEBridge_OpenDev($hash);
|
||||
return undef;
|
||||
|
||||
} elsif($cmd eq 'inactive') {
|
||||
readingsSingleUpdate($hash, 'state', 'inactive', 1 );
|
||||
return undef;
|
||||
|
||||
} else {
|
||||
my $list = "delete creategroup deletegroup savescene deletescene modifyscene scene createrule updaterule deleterule createsensor deletesensor configsensor setsensor deletewhitelist touchlink:noArg checkforupdate:noArg autodetect:noArg autocreate:noArg statusRequest:noArg";
|
||||
my $list = "active inactive delete creategroup deletegroup savescene deletescene modifyscene scene createrule updaterule deleterule createsensor deletesensor configsensor setsensor deletewhitelist touchlink:noArg checkforupdate:noArg autodetect:noArg autocreate:noArg statusRequest:noArg";
|
||||
$list .= " swupdate:noArg" if( defined($hash->{updatestate}) && $hash->{updatestate} =~ '^2' );
|
||||
return "Unknown argument $cmd, choose one of $list";
|
||||
}
|
||||
@ -948,7 +958,7 @@ sub HUEBridge_ProcessResponse($$)
|
||||
{
|
||||
my $error = $obj->[0]->{error}->{'description'};
|
||||
|
||||
readingsSingleUpdate($hash, 'lastError', $error, 0 );
|
||||
readingsSingleUpdate($hash, 'lastError', $error, 1 );
|
||||
}
|
||||
|
||||
if( !AttrVal( $name,'queryAfterSet', 1 ) ) {
|
||||
@ -1029,7 +1039,7 @@ HUEBridge_Call($$$$;$)
|
||||
my $name = $hash->{NAME};
|
||||
|
||||
if( IsDisabled($name) ) {
|
||||
readingsSingleUpdate($hash, 'state', 'disabled', 1 ) if( ReadingsVal($name,'state','' ) ne 'disabled' );
|
||||
readingsSingleUpdate($hash, 'state', 'inactive', 1 ) if( ReadingsVal($name,'state','' ) ne 'inactive' );
|
||||
return undef;
|
||||
}
|
||||
|
||||
@ -1234,7 +1244,7 @@ HUEBridge_dispatch($$$;$)
|
||||
{
|
||||
my $error = $json->[0]->{error}->{'description'};
|
||||
|
||||
readingsSingleUpdate($hash, 'lastError', $error, 0 );
|
||||
readingsSingleUpdate($hash, 'lastError', $error, 1 );
|
||||
|
||||
Log3 $name, 3, $error;
|
||||
}
|
||||
@ -1593,6 +1603,15 @@ HUEBridge_Attr($$$)
|
||||
available (indicated by updatestate with a value of 2. The version and release date is shown in the reading swupdate.<br>
|
||||
A notify of the form <code>define HUEUpdate notify bridge:swupdate.* {...}</code>
|
||||
can be used to be informed about available firmware updates.<br></li>
|
||||
<li>inactive<br>
|
||||
inactivates the current device. note the slight difference to the
|
||||
disable attribute: using set inactive the state is automatically saved
|
||||
to the statefile on shutdown, there is no explicit save necesary.<br>
|
||||
this command is intended to be used by scripts to temporarily
|
||||
deactivate the harmony device.<br>
|
||||
the concurrent setting of the disable attribute is not recommended.</li>
|
||||
<li>active<br>
|
||||
activates the current device (see inactive).</li>
|
||||
</ul><br>
|
||||
|
||||
<a name="HUEBridge_Attr"></a>
|
||||
|
Loading…
x
Reference in New Issue
Block a user