mirror of
https://github.com/fhem/fhem-mirror.git
synced 2025-01-31 18:59:33 +00:00
Luxtronik2: returnTemperatureSetBack eingeführt
git-svn-id: https://svn.fhem.de/fhem/trunk@5381 2b470e98-0d58-463d-a4d8-8e2adae1ed80
This commit is contained in:
parent
bf79073e97
commit
fc2c5af587
@ -46,7 +46,7 @@ sub LUXTRONIK2_storeReadings ($$$$$);
|
||||
sub LUXTRONIK2_doStatisticDelta ($$$$) ;
|
||||
|
||||
# Modul Version for remote debugging
|
||||
my $modulVersion = "2014-03-03";
|
||||
my $modulVersion = "2014-03-31";
|
||||
|
||||
#List of firmware versions that are known to be compatible with this modul
|
||||
my $testedFirmware = "#V1.54C#V1.60#V1.69#";
|
||||
@ -266,7 +266,8 @@ LUXTRONIK2_Set($$@)
|
||||
return $resultStr;
|
||||
} elsif(int(@_)==4 &&
|
||||
($cmd eq 'hotWaterTemperatureTarget'
|
||||
|| $cmd eq 'opModeHotWater')) {
|
||||
|| $cmd eq 'opModeHotWater'
|
||||
|| $cmd eq 'returnTemperatureSetBack')) {
|
||||
$hash->{LOCAL} = 1;
|
||||
$resultStr = LUXTRONIK2_SetParameter ($hash, $cmd, $val);
|
||||
$hash->{LOCAL} = 0;
|
||||
@ -276,6 +277,7 @@ LUXTRONIK2_Set($$@)
|
||||
my $list = "statusRequest:noArg"
|
||||
." resetStatistics:all,statBoilerGradientCoolDownMin"
|
||||
." hotWaterTemperatureTarget:slider,30.0,0.5,65.0"
|
||||
." returnTemperatureSetBack:slider,-5,0.5,5"
|
||||
." opModeHotWater:Auto,Party,Off"
|
||||
." synchronizeClockHeatPump:noArg"
|
||||
." INTERVAL:slider,30,30,1800";
|
||||
@ -539,7 +541,7 @@ LUXTRONIK2_DoUpdate($)
|
||||
# 18 - returnTemperatureExtern
|
||||
$return_str .= "|".($heatpump_visibility[24]==1 ? $heatpump_values[13] : "no");
|
||||
# 19 - flowRate
|
||||
$return_str .= "|".$heatpump_values[155];
|
||||
$return_str .= "|".($heatpump_visibility[240]==1 ? $heatpump_values[155] : "no");
|
||||
# 20 - firmware
|
||||
my $fwvalue = "";
|
||||
for(my $fi=81; $fi<91; $fi++) {
|
||||
@ -612,6 +614,8 @@ LUXTRONIK2_DoUpdate($)
|
||||
$return_str .= "|". ($heatpump_visibility[248]==1 ? $heatpump_values[161] : "no");
|
||||
# 53 - Number of visibility attributes
|
||||
$return_str .= "|".$countVisibAttr;
|
||||
# 54 - returnTemperatureSetBack
|
||||
$return_str .= "|".$heatpump_parameters[1];
|
||||
return $return_str;
|
||||
}
|
||||
|
||||
@ -855,8 +859,9 @@ LUXTRONIK2_UpdateDone($)
|
||||
readingsBulkUpdate( $hash, "flowTemperature", $flowTemperature);
|
||||
readingsBulkUpdate( $hash, "returnTemperature", $returnTemperature);
|
||||
readingsBulkUpdate( $hash, "returnTemperatureTarget",LUXTRONIK2_CalcTemp($a[17]));
|
||||
if ($a[18] !~ /no/) {readingsBulkUpdate( $hash, "returnTemperatureExtern",LUXTRONIK2_CalcTemp($a[18]))};
|
||||
readingsBulkUpdate( $hash, "flowRate",$a[19]);
|
||||
readingsBulkUpdate( $hash, "returnTemperaturSetBack",LUXTRONIK2_CalcTemp($a[54]));
|
||||
if ($a[18] !~ /no/) {readingsBulkUpdate( $hash, "returnTemperatureExtern",LUXTRONIK2_CalcTemp($a[18]));}
|
||||
if ($a[19] !~ /no/) {readingsBulkUpdate( $hash, "flowRate",$a[19]);}
|
||||
readingsBulkUpdate( $hash, "heatSourceIN",$heatSourceIN);
|
||||
readingsBulkUpdate( $hash, "heatSourceOUT",LUXTRONIK2_CalcTemp($a[24]));
|
||||
readingsBulkUpdate( $hash, "hotGasTemperature",LUXTRONIK2_CalcTemp($a[26]));
|
||||
@ -869,9 +874,9 @@ LUXTRONIK2_UpdateDone($)
|
||||
LUXTRONIK2_storeReadings $hash, "counterHoursHeatPump", $a[33], 3600, $doStatistic;
|
||||
LUXTRONIK2_storeReadings $hash, "counterHoursHeating", $a[34], 3600, $doStatistic;
|
||||
LUXTRONIK2_storeReadings $hash, "counterHoursHotWater", $a[35], 3600, $doStatistic;
|
||||
LUXTRONIK2_storeReadings $hash, "counterHeatQHeating", $a[36], 10, $doStatistic;
|
||||
LUXTRONIK2_storeReadings $hash, "counterHeatQHotWater", $a[37], 10, $doStatistic;
|
||||
LUXTRONIK2_storeReadings $hash, "counterHeatQTotal", $a[36] + $a[37], 10, $doStatistic;
|
||||
LUXTRONIK2_storeReadings $hash, "counterHeatQHeating", $a[36], 10, $a[19] !~ /no/ ? $doStatistic : 0;
|
||||
LUXTRONIK2_storeReadings $hash, "counterHeatQHotWater", $a[37], 10, $a[19] !~ /no/ ? $doStatistic : 0;
|
||||
LUXTRONIK2_storeReadings $hash, "counterHeatQTotal", $a[36] + $a[37], 10, $a[19] !~ /no/ ? $doStatistic : 0;
|
||||
|
||||
|
||||
# Input / Output status
|
||||
@ -1027,9 +1032,19 @@ LUXTRONIK2_SetParameter($$$)
|
||||
if (! exists($opMode{$realValue})) {
|
||||
return "$name Error: Wrong parameter given for opModeHotWater, use Automatik,Party,Off"
|
||||
}
|
||||
$setParameter = 4;
|
||||
$setParameter = 4;
|
||||
$setValue = $opMode{$realValue};
|
||||
}
|
||||
elsif ($parameterName eq "returnTemperatureSetBack") {
|
||||
#parameter number
|
||||
$setParameter = 1;
|
||||
#limit temperature range
|
||||
$realValue = -5 if( $realValue < -5 );
|
||||
$realValue = 5 if( $realValue > 5 );
|
||||
#Allow only integer temperature or with decimal .5
|
||||
$setValue = int($realValue * 2) * 5;
|
||||
$realValue = $setValue / 10;
|
||||
}
|
||||
else {
|
||||
return "$name LUXTRONIK2_SetParameter-Error: unknown parameter $parameterName";
|
||||
}
|
||||
@ -1625,6 +1640,10 @@ LUXTRONIK2_doStatisticDelta ($$$$)
|
||||
<li><code>hotWaterTemperatureTarget <temperature></code><br>
|
||||
Target temperature of domestic hot water boiler in °C
|
||||
</li><br>
|
||||
<li><code>returnTemperatureSetBack <Temperatur></code>
|
||||
<br>
|
||||
Decreasing or increasing of the returnTemperatureTarget by -5°C till + 5°C
|
||||
</li><br>
|
||||
<li><code>INTERVAL <polling interval></code><br>
|
||||
Polling interval in seconds
|
||||
</li><br>
|
||||
@ -1694,7 +1713,7 @@ LUXTRONIK2_doStatisticDelta ($$$$)
|
||||
<br>
|
||||
<i>Das Modul wurde bisher mit folgender Steuerungs-Firmware getestet: V1.54C, V1.60, V1.69.</i>
|
||||
<br>
|
||||
Mehr Infos unter im entsprechenden <a href="http://www.fhemwiki.de/wiki/Luxtronik_2.0">Artikel der FHEM-Wiki</a>.
|
||||
Mehr Infos im entsprechenden <u><a href="http://www.fhemwiki.de/wiki/Luxtronik_2.0">Artikel der FHEM-Wiki</a></u>.
|
||||
<br>
|
||||
<br>
|
||||
<a name="LUXTRONIK2define"></a>
|
||||
@ -1721,6 +1740,10 @@ LUXTRONIK2_doStatisticDelta ($$$$)
|
||||
<br>
|
||||
Soll-Temperatur des Heißwasserboilers in °C
|
||||
</li><br>
|
||||
<li><code>returnTemperatureSetBack <Temperatur></code>
|
||||
<br>
|
||||
Absenkung oder Anhebung der Rücklauftemperatur um -5°C - + 5°C
|
||||
</li><br>
|
||||
<li><code>INTERVAL <Abfrageinterval></code>
|
||||
<br>
|
||||
Abfrageinterval in Sekunden
|
||||
|
Loading…
Reference in New Issue