LUXTRONIK2: set hotWaterCirculationPumpExtern on|off
git-svn-id: https://svn.fhem.de/fhem/trunk@9153 2b470e98-0d58-463d-a4d8-8e2adae1ed80
This commit is contained in:
parent
8a33212be5
commit
f82cd2a14a
@ -147,47 +147,47 @@ LUXTRONIK2_Notify(@) {
|
||||
my ($hash,$dev) = @_;
|
||||
my $name = $hash->{NAME};
|
||||
|
||||
if ($dev->{NAME} eq "global" && grep (m/^INITIALIZED|REREADCFG$/,@{$dev->{CHANGED}})){
|
||||
# if ($dev->{NAME} eq "global" && grep (m/^INITIALIZED|REREADCFG$/,@{$dev->{CHANGED}})){
|
||||
# housekeeping
|
||||
my %cleanUp = (
|
||||
delayDeviceTime => "delayDeviceTimeCalc",
|
||||
deviceTimeStartReadings => "deviceTimeCalc",
|
||||
heatingSummerMode => "heatingLimit",
|
||||
thresholdTemperatureSummerMode => "thresholdHeatingLimit",
|
||||
lastDeviceClockSynch => "deviceTimeLastSync",
|
||||
operatingHoursHeatPump => "counterHoursHeatPump",
|
||||
operatingHoursSecondHeatSource1 => "counterHours2ndHeatSource1",
|
||||
operatingHoursSecondHeatSource2 => "counterHours2ndHeatSource2",
|
||||
operatingHoursSecondHeatSource3 => "counterHours2ndHeatSource3",
|
||||
operatingHoursHeating => "counterHoursHeating",
|
||||
operatingHoursHotWater => "counterHoursHotWater",
|
||||
heatQuantityHeating => "counterHeatQHeating",
|
||||
heatQuantityHotWater => "counterHeatQHotWater",
|
||||
heatQuantityTotal => "counterHeatQTotal",
|
||||
currentOperatingStatus1 => "opStateHeatPump1",
|
||||
currentOperatingState1 => "opStateHeatPump1",
|
||||
currentOperatingStatus2 => "opStateHeatPump3",
|
||||
currentOperatingState2 => "opStateHeatPump2",
|
||||
currentOperatingState3 => "opStateHeatPump3",
|
||||
heatingOperatingMode => "opModeHeating",
|
||||
heatingOperatingState => "opStateHeating",
|
||||
hotWaterOperatingMode => "opModeHotWater",
|
||||
hotWaterStatus => "opStateHotWater",
|
||||
hotWaterState => "opStateHotWater",
|
||||
heatingSystemCirculationPump => "heatingSystemCircPump",
|
||||
hotWaterCirculationPumpExtern => "hotWaterCircPumpExtern",
|
||||
currentThermalOutput => "thermalPower",
|
||||
returnTemperaturSetBack => "returnTemperatureSetBack",
|
||||
statGradientBoilerTempLoss => "statBoilerGradientHeatUp' and 'statBoilerGradientCoolDown" );
|
||||
my $oldReading;
|
||||
my $newReading;
|
||||
while (($oldReading, $newReading) = each(%cleanUp)) {
|
||||
if ( exists( $hash->{READINGS}{$oldReading} ) ) {
|
||||
delete($hash->{READINGS}{$oldReading});
|
||||
LUXTRONIK2_Log $name,2,"!!! Change/fix in LUXTRONIK2-Modul: '$oldReading' is now '$newReading'";
|
||||
}
|
||||
}
|
||||
}
|
||||
# my %cleanUp = (
|
||||
# delayDeviceTime => "delayDeviceTimeCalc",
|
||||
# deviceTimeStartReadings => "deviceTimeCalc",
|
||||
# heatingSummerMode => "heatingLimit",
|
||||
# thresholdTemperatureSummerMode => "thresholdHeatingLimit",
|
||||
# lastDeviceClockSynch => "deviceTimeLastSync",
|
||||
# operatingHoursHeatPump => "counterHoursHeatPump",
|
||||
# operatingHoursSecondHeatSource1 => "counterHours2ndHeatSource1",
|
||||
# operatingHoursSecondHeatSource2 => "counterHours2ndHeatSource2",
|
||||
# operatingHoursSecondHeatSource3 => "counterHours2ndHeatSource3",
|
||||
# operatingHoursHeating => "counterHoursHeating",
|
||||
# operatingHoursHotWater => "counterHoursHotWater",
|
||||
# heatQuantityHeating => "counterHeatQHeating",
|
||||
# heatQuantityHotWater => "counterHeatQHotWater",
|
||||
# heatQuantityTotal => "counterHeatQTotal",
|
||||
# currentOperatingStatus1 => "opStateHeatPump1",
|
||||
# currentOperatingState1 => "opStateHeatPump1",
|
||||
# currentOperatingStatus2 => "opStateHeatPump3",
|
||||
# currentOperatingState2 => "opStateHeatPump2",
|
||||
# currentOperatingState3 => "opStateHeatPump3",
|
||||
# heatingOperatingMode => "opModeHeating",
|
||||
# heatingOperatingState => "opStateHeating",
|
||||
# hotWaterOperatingMode => "opModeHotWater",
|
||||
# hotWaterStatus => "opStateHotWater",
|
||||
# hotWaterState => "opStateHotWater",
|
||||
# heatingSystemCirculationPump => "heatingSystemCircPump",
|
||||
# hotWaterCirculationPumpExtern => "hotWaterCircPumpExtern",
|
||||
# currentThermalOutput => "thermalPower",
|
||||
# returnTemperaturSetBack => "returnTemperatureSetBack",
|
||||
# statGradientBoilerTempLoss => "statBoilerGradientHeatUp' and 'statBoilerGradientCoolDown" );
|
||||
# my $oldReading;
|
||||
# my $newReading;
|
||||
# while (($oldReading, $newReading) = each(%cleanUp)) {
|
||||
# if ( exists( $hash->{READINGS}{$oldReading} ) ) {
|
||||
# delete($hash->{READINGS}{$oldReading});
|
||||
# LUXTRONIK2_Log $name,2,"!!! Change/fix in LUXTRONIK2-Modul: '$oldReading' is now '$newReading'";
|
||||
# }
|
||||
# }
|
||||
# }
|
||||
return;
|
||||
}
|
||||
|
||||
@ -296,7 +296,8 @@ LUXTRONIK2_Set($$@)
|
||||
LUXTRONIK2_Log $name, 3, $resultStr;
|
||||
return $resultStr;
|
||||
|
||||
} elsif(int(@_)==4 &&
|
||||
}
|
||||
elsif(int(@_)==4 &&
|
||||
($cmd eq 'hotWaterTemperatureTarget'
|
||||
|| $cmd eq 'opModeHotWater'
|
||||
|| $cmd eq 'returnTemperatureSetBack')) {
|
||||
@ -306,11 +307,23 @@ LUXTRONIK2_Set($$@)
|
||||
$hash->{LOCAL} = 0;
|
||||
return $resultStr;
|
||||
}
|
||||
elsif( int(@_)==4 && $cmd eq 'hotWaterCircPumpExtern' ) { # Einstellung->Entlüftung
|
||||
Log3 $name, 3, "LUXTRONIK2: set $name $cmd $val";
|
||||
return "$name Error: Wrong parameter given for opModeHotWater, use Automatik,Party,Off"
|
||||
if $val !~ /on|off/;
|
||||
$hash->{LOCAL} = 1;
|
||||
$resultStr = LUXTRONIK2_SetParameter ($hash, $cmd, $val);
|
||||
if ($val eq "on" ) { $resultStr .= LUXTRONIK2_SetParameter ($hash, "confirmDegasing", 1); }
|
||||
else { $resultStr .= LUXTRONIK2_SetParameter ($hash, "confirmDegasing", 0); } # only send if no degasing checkbox is selected at all.
|
||||
$hash->{LOCAL} = 0;
|
||||
return $resultStr;
|
||||
}
|
||||
|
||||
my $list = "statusRequest:noArg"
|
||||
." activeTariff:0,1,2,3,4,5,6,7,8,9"
|
||||
." resetStatistics:all,statBoilerGradientCoolDownMin,statAmbientTemp...,statElectricity...,statHours...,statHeatQ..."
|
||||
." hotWaterCircPumpExtern:on,off"
|
||||
." hotWaterTemperatureTarget "
|
||||
." resetStatistics:all,statBoilerGradientCoolDownMin,statAmbientTemp...,statElectricity...,statHours...,statHeatQ..."
|
||||
." returnTemperatureSetBack "
|
||||
." opModeHotWater:Auto,Party,Off"
|
||||
." synchronizeClockHeatPump:noArg"
|
||||
@ -594,7 +607,7 @@ LUXTRONIK2_DoUpdate($)
|
||||
# 27 - heatingSystemCircPump
|
||||
$return_str .= "|".$heatpump_values[39];
|
||||
# 28 - hotWaterCircPumpExtern
|
||||
$return_str .= "|".$heatpump_values[46];
|
||||
$return_str .= "|". ($heatpump_visibility[57]==1 ? $heatpump_values[46] : "no");
|
||||
# 29 - readingFhemStartTime
|
||||
$return_str .= "|".$readingStartTime;
|
||||
# 30 - readingFhemEndTime
|
||||
@ -662,7 +675,6 @@ LUXTRONIK2_DoUpdate($)
|
||||
return $return_str;
|
||||
}
|
||||
|
||||
|
||||
sub ########################################
|
||||
LUXTRONIK2_UpdateDone($)
|
||||
{
|
||||
@ -746,10 +758,12 @@ LUXTRONIK2_UpdateDone($)
|
||||
|
||||
my $doStatistic = AttrVal($name,"doStatistics",0);
|
||||
|
||||
# Error
|
||||
if ($a[1]==0 ) {
|
||||
readingsSingleUpdate($hash,"state","Error: ".$a[2],1);
|
||||
$counterRetry = 0;
|
||||
}
|
||||
# Busy, restart update
|
||||
elsif ($a[1]==2 ) {
|
||||
if ($counterRetry <=3) {
|
||||
InternalTimer(gettimeofday() + 5, "LUXTRONIK2_GetUpdate", $hash, 0);
|
||||
@ -759,6 +773,7 @@ LUXTRONIK2_UpdateDone($)
|
||||
LUXTRONIK2_Log $hash, 2, "Device reading skipped after $counterRetry tries with parameter change on target";
|
||||
}
|
||||
}
|
||||
# Update readings
|
||||
elsif ($a[1]==1 ) {
|
||||
$counterRetry = 0;
|
||||
|
||||
@ -1048,7 +1063,6 @@ LUXTRONIK2_UpdateAborted($)
|
||||
LUXTRONIK2_Log $hash, 1, "Timeout when connecting to host $host";
|
||||
}
|
||||
|
||||
|
||||
sub ########################################
|
||||
LUXTRONIK2_CalcTemp($)
|
||||
{
|
||||
@ -1084,15 +1098,14 @@ LUXTRONIK2_SetParameter($$$)
|
||||
my $name = $hash->{NAME};
|
||||
|
||||
my %opMode = ( "Auto" => 0,
|
||||
"Party" => 2,
|
||||
"Off" => 4);
|
||||
"Party" => 2,
|
||||
"Off" => 4);
|
||||
|
||||
if(AttrVal($name, "allowSetParameter", 0) != 1) {
|
||||
return $name." Error: Setting of parameters not allowed. Please set attribut 'allowSetParameter' to 1";
|
||||
}
|
||||
|
||||
if ($parameterName eq "hotWaterTemperatureTarget")
|
||||
{
|
||||
if ($parameterName eq "hotWaterTemperatureTarget") {
|
||||
#parameter number
|
||||
$setParameter = 2;
|
||||
#limit temperature range
|
||||
@ -1103,8 +1116,7 @@ LUXTRONIK2_SetParameter($$$)
|
||||
$realValue = $setValue / 10;
|
||||
}
|
||||
|
||||
elsif ($parameterName eq "opModeHotWater")
|
||||
{
|
||||
elsif ($parameterName eq "opModeHotWater") {
|
||||
if (! exists($opMode{$realValue})) {
|
||||
return "$name Error: Wrong parameter given for opModeHotWater, use Automatik,Party,Off"
|
||||
}
|
||||
@ -1112,8 +1124,7 @@ LUXTRONIK2_SetParameter($$$)
|
||||
$setValue = $opMode{$realValue};
|
||||
}
|
||||
|
||||
elsif ($parameterName eq "returnTemperatureSetBack")
|
||||
{
|
||||
elsif ($parameterName eq "returnTemperatureSetBack") {
|
||||
#parameter number
|
||||
$setParameter = 1;
|
||||
#limit temperature range
|
||||
@ -1123,8 +1134,17 @@ LUXTRONIK2_SetParameter($$$)
|
||||
$setValue = int($realValue * 2) * 5;
|
||||
$realValue = $setValue / 10;
|
||||
}
|
||||
else
|
||||
{
|
||||
|
||||
elsif ($parameterName eq "hotWaterCircPumpExtern") { #isVisible(167)
|
||||
$setParameter = 684;
|
||||
$setValue = $realValue eq "on" ? 1 : 0;
|
||||
}
|
||||
elsif ($parameterName eq "confirmDegasing") {
|
||||
$setParameter = 158;
|
||||
$setValue = $realValue;
|
||||
}
|
||||
|
||||
else {
|
||||
return "$name LUXTRONIK2_SetParameter-Error: unknown parameter $parameterName";
|
||||
}
|
||||
|
||||
@ -1137,11 +1157,12 @@ LUXTRONIK2_SetParameter($$$)
|
||||
PeerPort => 8888,
|
||||
Proto => 'tcp'
|
||||
);
|
||||
if (!$socket) {
|
||||
# Socket error
|
||||
if (!$socket) {
|
||||
LUXTRONIK2_Log $name, 1, "Could not open connection to host ".$host;
|
||||
return "$name Error: Could not open connection to host ".$host;
|
||||
}
|
||||
$socket->autoflush(1);
|
||||
$socket->autoflush(1);
|
||||
|
||||
LUXTRONIK2_Log $name, 5, "Set parameter $parameterName ($setParameter) = $realValue ($setValue)";
|
||||
$socket->send(pack("N", 3002));
|
||||
@ -1170,14 +1191,13 @@ LUXTRONIK2_SetParameter($$$)
|
||||
|
||||
$socket->close();
|
||||
|
||||
readingsSingleUpdate($hash,$parameterName,$realValue,1);
|
||||
readingsSingleUpdate($hash,$parameterName,$realValue,1) unless $parameterName eq "confirmDegasing";
|
||||
|
||||
return undef;
|
||||
}
|
||||
|
||||
}
|
||||
|
||||
|
||||
sub ########################################
|
||||
LUXTRONIK2_synchronizeClock (@)
|
||||
{
|
||||
@ -1779,12 +1799,15 @@ LUXTRONIK2_doStatisticDeltaSingle ($$$$$$$)
|
||||
<li><code>INTERVAL <polling interval></code><br>
|
||||
Polling interval in seconds
|
||||
</li><br>
|
||||
<li><code>opModeHotWater <Mode></code><br>
|
||||
Operating Mode of domestic hot water boiler (Auto | Party | Off)
|
||||
</li><br>
|
||||
<li><code>hotWaterTemperatureTarget <temperature></code><br>
|
||||
Target temperature of domestic hot water boiler in °C
|
||||
</li><br>
|
||||
<li><code>hotWaterCirculationPumpExtern <on | off></code><br>
|
||||
Switches the external circulation pump for the hot water on or off. The circulation prevents a cool down of the hot water in the pipes but increases the heat consumption drastically.
|
||||
</li><br>
|
||||
<li><code>opModeHotWater <Mode></code><br>
|
||||
Operating Mode of domestic hot water boiler (Auto | Party | Off)
|
||||
</li><br>
|
||||
<li><code>resetStatistics <statReadings></code>
|
||||
<br>
|
||||
Deletes the selected statistic values <i>all, statBoilerGradientCoolDownMin, statAmbientTemp..., statElectricity..., statHours..., statHeatQ...</i>
|
||||
@ -1898,14 +1921,17 @@ LUXTRONIK2_doStatisticDeltaSingle ($$$$$$$)
|
||||
Dieser Wert muss entsprechend des vorhandenen oder geplanten Tarifes zum jeweiligen Zeitpunkt z.B. durch den FHEM-Befehl "at" gesetzt werden.<br>
|
||||
0 = tariflos
|
||||
</li><br>
|
||||
<li><code>opModeHotWater <Betriebsmodus></code>
|
||||
<br>
|
||||
Betriebsmodus des Heißwasserboilers ( Auto | Party | Off )
|
||||
<li><code>hotWaterCirculationPumpExtern <on | off></code><br>
|
||||
Schaltet die externe Warmwasser-Zirkulationspumpe an oder aus. Durch die Zirkulation wird ein Abkühlen des Warmwassers in den Hausleitungen verhindert. Der Wärmeverbrauch steigt jedoch drastisch.
|
||||
</li><br>
|
||||
<li><code>hotWaterTemperatureTarget <Temperatur></code>
|
||||
<br>
|
||||
Soll-Temperatur des Heißwasserboilers in °C
|
||||
</li><br>
|
||||
<li><code>opModeHotWater <Betriebsmodus></code>
|
||||
<br>
|
||||
Betriebsmodus des Heißwasserboilers ( Auto | Party | Off )
|
||||
</li><br>
|
||||
<li><code>resetStatistics <statWerte></code>
|
||||
<br>
|
||||
Löscht die ausgewählten statisischen Werte: <i>all, statBoilerGradientCoolDownMin, statAmbientTemp..., statElectricity..., statHours..., statHeatQ...</i>
|
||||
|