- bugfix: 62_EMEM.pm: changed reading energy_total_kWh to energy_kWh_w, added energy_kWh (formerly energy_total_kWh)

- changed em1010.pl accordingly, added em1000em doc for getDevStatus reply from device
 - minor changes in fhem.html


git-svn-id: https://svn.fhem.de/fhem/trunk@144 2b470e98-0d58-463d-a4d8-8e2adae1ed80
This commit is contained in:
borisneubert 2008-01-06 12:50:25 +00:00
parent 26e434aa55
commit f693a6b452
6 changed files with 76 additions and 36 deletions

View File

@ -376,6 +376,8 @@
- feature: added 93_DbLog.pm, database logging facility (Boris, 30.12.) - feature: added 93_DbLog.pm, database logging facility (Boris, 30.12.)
- feature: webfrontend/pgm2 converted to a FHEM module - feature: webfrontend/pgm2 converted to a FHEM module
- bugfix: 99_SUNRISE_EL.pm: may schedule double events - bugfix: 99_SUNRISE_EL.pm: may schedule double events
- bugfix: 62_EMEM.pl, contrib/em1010.pl: correct readings for energy_kWh
and energy_kWh_w (Boris, 06.01.08)
- TODO - TODO
emem -2.5kW / getDevData for emwz -1 emem -2.5kW / getDevData for emwz -1

View File

@ -50,22 +50,30 @@ EMEM_GetStatus($)
} }
my $pulses=w($d,13); my $pulses=w($d,13);
my $pulses_max= w($d,15);
my $iec = 1000; my $iec = 1000;
my $cur_power = $pulses / 100; my $cur_power = $pulses / 100;
my $cur_power_max = $pulses_max / 100;
if($cur_power > 30) { # 20Amp x 3 Phase if($cur_power > 30) { # 20Amp x 3 Phase
my $msg = "EMEM Bogus reading: curr. power is reported to be $cur_power setting to -1"; my $msg = "EMEM Bogus reading: curr. power is reported to be $cur_power, setting to -1";
Log GetLogLevel($name,2), $msg; Log GetLogLevel($name,2), $msg;
#return $msg; #return $msg;
$cur_power = -1.0; $cur_power = -1.0;
} }
if($cur_power_max > 30) { # 20Amp x 3 Phase
$cur_power_max = -1.0;
}
my %vals; my %vals;
$vals{"5min_pulses"} = $pulses; $vals{"5min_pulses"} = $pulses;
$vals{"5min_pulses_max"} = $pulses_max;
$vals{"energy_kWh_h"} = sprintf("%0.3f", dw($d,33) / $iec); $vals{"energy_kWh_h"} = sprintf("%0.3f", dw($d,33) / $iec);
$vals{"energy_today_kWh_d"} = sprintf("%0.3f", dw($d,37) / $iec); $vals{"energy_kWh_d"} = sprintf("%0.3f", dw($d,37) / $iec);
$vals{"energy_total_kWh"} = sprintf("%0.3f", dw($d,41) / $iec); $vals{"energy_kWh_w"} = sprintf("%0.3f", dw($d,41) / $iec);
$vals{"energy_kWh"} = sprintf("%0.3f", dw($d, 7) / $iec);
$vals{"power_kW"} = sprintf("%.3f", $cur_power); $vals{"power_kW"} = sprintf("%.3f", $cur_power);
$vals{"power_kW_max"} = sprintf("%.3f", $cur_power_max);
$vals{"alarm_PA_W"} = w($d,45); $vals{"alarm_PA_W"} = w($d,45);
$vals{"price_CF"} = sprintf("%.3f", w($d,47)/10000); $vals{"price_CF"} = sprintf("%.3f", w($d,47)/10000);
@ -84,7 +92,7 @@ EMEM_GetStatus($)
} }
$hash->{STATE} = "$cur_power kW"; $hash->{STATE} = "$cur_power kW";
Log GetLogLevel($name,4), "EMEM $name: $cur_power kW / $vals{energy_kWh_h} kWh/h"; Log GetLogLevel($name,4), "EMEM $name: $cur_power kW / $vals{energy_kWh} kWh";
return $hash->{STATE}; return $hash->{STATE};
} }

View File

@ -185,3 +185,11 @@
No more need for a webserver for basic WEB administration. For HTTPS or No more need for a webserver for basic WEB administration. For HTTPS or
password you still need apache or the like. password you still need apache or the like.
One step closer for complete fhem on the FritzBox. One step closer for complete fhem on the FritzBox.
- Boris Sun Jan 06 13:35:00 CET 2008
- bugfix: 62_EMEM.pm: changed reading energy_total_kWh to energy_kWh_w,
added energy_kWh (formerly energy_total_kWh)
- changed em1010.pl accordingly, added em1000em doc for getDevStatus reply from
device
- minor changes in fhem.html

View File

@ -105,6 +105,17 @@ DbLog_ParseEvent($$)
($type eq "M232Counter") || ($type eq "M232Counter") ||
($type eq "EMEM")) { ($type eq "EMEM")) {
} }
# FS20
elsif($type eq "FS20") {
@parts= split(/ /,$value);
my $reading= $parts[0]; if(!defined($reading)) { $reading= ""; }
$value= join(" ", shift @parts);
if($reading =~ m(^dim*%$)) {
$value= substr($reading,3,length($reading)-4);
$reading= "dim";
$unit= "%";
}
}
# FHT # FHT
elsif($type eq "FHT") { elsif($type eq "FHT") {
if($reading =~ m(-temp)) { $value=~ s/ \(Celsius\)//; $unit= "°C"; } if($reading =~ m(-temp)) { $value=~ s/ \(Celsius\)//; $unit= "°C"; }

View File

@ -251,18 +251,22 @@ getDevStatus()
return; return;
} }
my $pulses=w($d,13); my $pulses=w($d,13);
my $pulses_max=w($d,15);
my $ec=w($d,49) / 10; my $ec=w($d,49) / 10;
my $cur_energy=0; my $cur_energy=0;
my $cur_power=0; my $cur_power=0;
my $cur_power_max=0;
my $sum_h_energy=0; my $sum_h_energy=0;
my $sum_d_energy=0; my $sum_d_energy=0;
my $sum_w_energy=0;
my $total_energy=0; my $total_energy=0;
my $iec=0; my $iec=0;
printf(" Readings (off 02): %d\n", w($d,2)); printf(" Readings (off 2): %d\n", w($d,2));
printf(" Nr devs (off 05): %d\n", b($d,6)); printf(" Nr devs (off 6): %d\n", b($d,6));
printf(" puls/5min (off 13): %d\n", $pulses); printf(" puls/5min (off 13): %d\n", $pulses);
printf(" Startblk (off 18): %d\n", b($d,18)+13); printf(" puls.max/5min (off 15): %d\n", $pulses_max);
#printf(" Startblk (off 18): %d\n", b($d,18)+13);
#for (my $lauf = 19; $lauf < 45; $lauf += 2) { #for (my $lauf = 19; $lauf < 45; $lauf += 2) {
# printf(" t wert (off $lauf): %d\n", w($d,$lauf)); # printf(" t wert (off $lauf): %d\n", w($d,$lauf));
#} #}
@ -272,6 +276,7 @@ getDevStatus()
# Sensor 5.. # Sensor 5..
$iec = 1000; $iec = 1000;
$cur_power = $pulses / 100; $cur_power = $pulses / 100;
$cur_power_max = $pulses_max / 100;
} else { } else {
# Sensor 1..4 # Sensor 1..4
$iec = $ec; $iec = $ec;
@ -279,16 +284,19 @@ getDevStatus()
$cur_power = $cur_energy / 5 * 60; # 5minute interval scaled to 1h $cur_power = $cur_energy / 5 * 60; # 5minute interval scaled to 1h
printf(" cur.energy(off ): %.3f kWh\n", $cur_energy); printf(" cur.energy(off ): %.3f kWh\n", $cur_energy);
} }
$sum_h_energy= dw($d,33) / $iec; # 33= pulses this our $sum_h_energy= dw($d,33) / $iec; # 33= pulses this hour
$sum_d_energy= dw($d,37) / $iec; # 37= pulses today $sum_d_energy= dw($d,37) / $iec; # 37= pulses today
$total_energy= dw($d,41) / $iec; # 41= pulses total $sum_w_energy= dw($d,41) / $iec; # 41= pulses this week
printf(" cur.power (off ): %.3f kW avr.\n", $cur_power); $total_energy= dw($d, 7) / $iec; # 7= pulses total
printf(" energy(off 33): %.3f kWh/h\n", $sum_h_energy); printf(" cur.power ( ): %.3f kW\n", $cur_power);
printf(" energy(off 37): %.3f kWh/d\n", $sum_d_energy); printf(" cur.power max ( ): %.3f kW\n", $cur_power_max);
printf(" ttl energy(off 41): %.3f kWh (total)\n", $total_energy); printf(" energy h (off 33): %.3f kWh (h)\n", $sum_h_energy);
printf(" energy d (off 37): %.3f kWh (d)\n", $sum_d_energy);
printf(" energy w (off 41): %.3f kWh (w)\n", $sum_w_energy);
printf(" total energy (off 7): %.3f kWh (total)\n", $total_energy);
printf(" Alarm PA (off 45): %d W\n", w($d,45)); printf(" Alarm PA (off 45): %d W\n", w($d,45));
printf(" Price CF (off 47): %0.2f (EUR/KWH)\n", w($d,47)/10000); printf(" Price CF (off 47): %0.2f EUR/kWh\n", w($d,47)/10000);
printf(" R/KW EC (off 49): %d\n", $ec); printf(" R/kW EC (off 49): %d\n", $ec);
hexdump($d); hexdump($d);
} }

View File

@ -15,28 +15,31 @@ Formerly known as fhz1000.pl
<h2>News (as of =DATE=, Version =VERS=)</h2> <h2>News (as of =DATE=, Version =VERS=)</h2>
<ul> <ul>
<li>feature: added archivedir/archivecmd to the the main logfile <li>feature: added archivedir/archivecmd to the the main logfile</li>
<li>feature: 99_Sunrise_EL.pm (does not need any Date modules) <li>feature: 99_Sunrise_EL.pm (does not need any Date modules)</li>
<li>bugfix: seldom xmllist error resulting in corrupt xml (Martin/Peter, 4.9) <li>bugfix: seldom xmllist error resulting in corrupt xml (Martin/Peter, 4.9)</li>
<li>bugfix: FHT mode holiday_short added (9.9, Dirk) <li>bugfix: FHT mode holiday_short added (9.9, Dirk)</li>
<li>bugfix: Modifying a device from its own trigger crashes (Klaus, 10.9) <li>bugfix: Modifying a device from its own trigger crashes (Klaus, 10.9)</li>
<li>feature: webpgm2 output reformatted <li>feature: webpgm2 output reformatted</li>
<li>feature: webpgm2 displaying multiple plots <li>feature: webpgm2 displaying multiple plots</li>
<li>feature: FHT lime-protection code discovered by Dirk (7.10) <li>feature: FHT lime-protection code discovered by Dirk (7.10)</li>
<li>feature: softwarebuffer for FHT devices (Dirk 17.10) <li>feature: softwarebuffer for FHT devices (Dirk 17.10)</li>
<li>feature: FHT low temperatur warning and offset (Dirk 17.10) <li>feature: FHT low temperatur warning and offset (Dirk 17.10)</li>
<li>change: change FHT state into warnings (Dirk 17.10)<br> <li>change: change FHT state into warnings (Dirk 17.10)<br>
NOTE: you'll get an undefined type state &amp; undefined type NOTE: you'll get an undefined type state &amp; undefined type
unknown_85 message after upgrade, this will disappear at the unknown_85 message after upgrade, this will disappear at the
second start.</li> second start.</li>
<li>feature: Softwarebuffer code simplified (Rudi 22.11) <li>feature: Softwarebuffer code simplified (Rudi 22.11)</li>
<li>bugfix: bug #12327 doppeltes my <li>bugfix: bug #12327 doppeltes my</li>
<li>bugfix: set STATE from trigger <li>bugfix: set STATE from trigger</li>
<li>bugfix: readings state vs STATE problem (xmllist/trigger) <li>bugfix: readings state vs STATE problem (xmllist/trigger)</li>
<li>change: SUNRISE doc changed (99_SUNRISE.pm -> 99_SUNRISE_EL.pm) <li>change: SUNRISE doc changed (99_SUNRISE.pm -> 99_SUNRISE_EL.pm)</li>
<li>feature: support for the M232 ELV device (Boris, 25.11) <li>feature: support for the M232 ELV device (Boris, 25.11)</li>
<li>feature: alternativ Quad-based numbers for the FS20 (Matthias, 24.11) <li>feature: alternativ Quad-based numbers for the FS20 (Matthias, 24.11)</li>
<li>feature: dummy type added (contrib/99_dummy.pm) <li>feature: dummy type added (contrib/99_dummy.pm)</li>
<li>feature: added database logging facility (93_DbLog.pm) (Boris, 29.12)</li>
<li>feature: support for %NAME, %EVENT, %TYPE parameters in notify definition (Boris, 29.12)</li>
<li>bugfix: 62_EMEM.pm: energy_total_kWh renamed to energy_kWh_w, energy_kWh added (Boris, 6.1)</li>
</ul> </ul>
</ul> </ul>
@ -70,7 +73,7 @@ Currently implemented features:<br>
<li>reading EM1000WZ/EM1000EM data via an attached EM1010PC</li> <li>reading EM1000WZ/EM1000EM data via an attached EM1010PC</li>
<li>reading attached SCIVT devices</li> <li>reading attached SCIVT devices</li>
<li>reading attached M232 devices</li> <li>reading attached M232 devices</li>
<li>logging events to files (or database), with regexp filters</li> <li>logging events to files or databases, with regexp filters</li>
<li>notifying external programs or internal modules when receiving certain <li>notifying external programs or internal modules when receiving certain
events</li> events</li>
<li>timed commands (e.g. switching a lamp on from sunset till midnight)</li> <li>timed commands (e.g. switching a lamp on from sunset till midnight)</li>