# Add changes at the top of the list. Keep it in ASCII, and 80-char wide.
|
||||
# Do not insert empty lines here, update check depends on it.
|
||||
- SVN
|
||||
- feature: LUXTRONIK2: attribute 'doStatistics' calculates boiler gradients
|
||||
- feature: GEOFANCY: support both apps, Geofency.app and Geofancy.app
|
||||
- feature: LightScene: added attribute lightSceneRestoreOnlyIfChanged
|
||||
- bugfix: SYSMON: Fix: CPUTemp & BogoMIPS for utilite-Box.
|
||||
@ -30,7 +31,7 @@
|
||||
- feature: DASHBOARD: Dashboard get Tabs. Redesign saving of Group
|
||||
positioning.
|
||||
- bugfix: SYSMON: Log Warnings, unnoetige Readings erkenen und entfernen
|
||||
- feature: LUXTRONIK2: Setting of controller parameter and internal clock now possible
|
||||
- feature: LUXTRONIK2: Setting of controller parameter and internal clock
|
||||
- feature: new module 71_YAMAHA_BD.pm to control Yamaha Blu-Ray
|
||||
players over network.
|
||||
- bugfix: DbLog: fix for plotfork
|
||||
@ -59,7 +60,7 @@
|
||||
the Room Dashboard.
|
||||
- bugfix: VIERA: fixed bug related to set command remoteControl
|
||||
- bugfix: ENIGMA2: improved compatibility for Fritzbox and old
|
||||
Webif versions
|
||||
Webif versions
|
||||
- feature: readingsGroup: process events only if visible in browser,
|
||||
allow <br> for line breaks in multi-reading lines
|
||||
- feature: FLOORPLAN: Style4 (S300TH specific) now keeps its formatting
|
||||
|
@ -83,6 +83,7 @@ LUXTRONIK2_Define($$)
|
||||
$hash->{STATE} = "Initializing";
|
||||
$hash->{HOST} = $host;
|
||||
$hash->{INTERVAL} = $interval;
|
||||
$hash->{NOTIFYDEV} = "global";
|
||||
|
||||
RemoveInternalTimer($hash);
|
||||
#Get first data after 10 seconds
|
||||
@ -92,7 +93,8 @@ LUXTRONIK2_Define($$)
|
||||
$hash->{fhem}{durationFetchReadingsMin} = 0;
|
||||
$hash->{fhem}{durationFetchReadingsMax} = 0;
|
||||
$hash->{fhem}{alertFirmware} = 0;
|
||||
$hash->{fhem}{statModeHotWater} = 0;
|
||||
$hash->{fhem}{statBoilerHeatUpStep} = 0;
|
||||
$hash->{fhem}{statBoilerCoolDownStep} = 0;
|
||||
|
||||
$hash->{fhem}{modulVersion} = $modulVersion;
|
||||
Log3 $hash,5,"$name: LUXTRONIK2.pm version is $modulVersion.";
|
||||
@ -117,8 +119,7 @@ LUXTRONIK2_Notify(@) {
|
||||
my ($hash,$dev) = @_;
|
||||
my $name = $hash->{NAME};
|
||||
|
||||
if ($dev->{NAME} eq "global" ) { # splitted to reduce CPU load
|
||||
if (grep (m/^INITIALIZED|REREADCFG$/,@{$dev->{CHANGED}})){
|
||||
if ($dev->{NAME} eq "global" && grep (m/^INITIALIZED|REREADCFG$/,@{$dev->{CHANGED}})){
|
||||
# housekeeping
|
||||
my %cleanUp = (
|
||||
delayDeviceTime => "delayDeviceTimeCalc",
|
||||
@ -146,15 +147,14 @@ LUXTRONIK2_Notify(@) {
|
||||
hotWaterStatus => "opStateHotWater",
|
||||
hotWaterState => "opStateHotWater",
|
||||
heatingSystemCirculationPump => "heatingSystemCircPump",
|
||||
hotWaterCirculationPumpExtern => "hotWaterCircPumpExtern" );
|
||||
|
||||
hotWaterCirculationPumpExtern => "hotWaterCircPumpExtern",
|
||||
statGradientBoilerTempLoss => "statBoilerGradientHeatUp' and 'statBoilerGradientCoolDown" );
|
||||
my $oldReading;
|
||||
my $newReading;
|
||||
while (($oldReading, $newReading) = each(%cleanUp)) {
|
||||
if ( exists( $hash->{READINGS}{$oldReading} ) ) {
|
||||
delete($hash->{READINGS}{$oldReading});
|
||||
Log3 $name,2,"$name: !!! Change/fix in LUXTRONIK2-Modul: '$oldReading' is now '$newReading'";
|
||||
}
|
||||
}
|
||||
}
|
||||
}
|
||||
@ -174,14 +174,14 @@ LUXTRONIK2_Set($$@)
|
||||
$hash->{LOCAL} = 0;
|
||||
return undef;
|
||||
}
|
||||
elsif ($cmd eq 'deleteStatistics') {
|
||||
if ( ($val eq "all" || $val eq "statGradientBoilerTempLoss")
|
||||
&& exists($defs{$name}{READINGS}{statGradientBoilerTempLoss})) {
|
||||
delete $defs{$name}{READINGS}{statGradientBoilerTempLoss};
|
||||
$resultStr .= " statGradientBoilerTempLoss";
|
||||
elsif ($cmd eq 'resetStatistics') {
|
||||
if ( ($val eq "all" || $val eq "statBoilerGradientCoolDownMin")
|
||||
&& exists($defs{$name}{READINGS}{statBoilerGradientCoolDownMin})) {
|
||||
delete $defs{$name}{READINGS}{statBoilerGradientCoolDownMin};
|
||||
$resultStr .= " statBoilerGradientCoolDownMin";
|
||||
}
|
||||
if ( $resultStr eq "" ) {
|
||||
$resultStr = "$name: No statistics to delete";
|
||||
$resultStr = "$name: No statistics to reset";
|
||||
} else {
|
||||
$resultStr = "$name: Statistic value(s) deleted:" . $resultStr;
|
||||
}
|
||||
@ -233,7 +233,7 @@ LUXTRONIK2_Set($$@)
|
||||
}
|
||||
|
||||
my $list = "statusRequest:noArg".
|
||||
" deleteStatistics:all,statGradientBoilerTempLoss".
|
||||
" resetStatistics:all,statBoilerGradientCoolDownMin".
|
||||
" hotWaterTemperatureTarget:slider,30.0,0.5,65.0".
|
||||
" opModeHotWater:Auto,Party,Off".
|
||||
" synchronizeClockHeatPump:noArg".
|
||||
@ -582,7 +582,9 @@ SKIP_VISIBILITY_READING:
|
||||
$return_str .= "|".$heatpump_parameters[13];
|
||||
# 48 - thresholdTemperatureSetBack
|
||||
$return_str .= "|".$heatpump_parameters[111];
|
||||
|
||||
# 49 - hotWaterTemperatureHysterese
|
||||
$return_str .= "|".$heatpump_parameters[74];
|
||||
|
||||
return $return_str;
|
||||
}
|
||||
|
||||
@ -611,7 +613,9 @@ LUXTRONIK2_UpdateDone($)
|
||||
1 => "Waermepumpe steht",
|
||||
2 => "Waermepumpe kommt",
|
||||
4 => "Fehler",
|
||||
5 => "Abtauen" );
|
||||
5 => "Abtauen",
|
||||
6 => "Warte auf LIN-Verbindung",
|
||||
7 => "Verdichter heizt auf");
|
||||
my %wpOpStat2 = ( 0 => "Heizbetrieb",
|
||||
1 => "Keine Anforderung",
|
||||
2 => "Netz Einschaltverzoegerung",
|
||||
@ -623,7 +627,7 @@ LUXTRONIK2_UpdateDone($)
|
||||
8 => "Pumpenvorlauf",
|
||||
9 => "Thermische Desinfektion",
|
||||
10 => "Kuehlbetrieb",
|
||||
12 => "Schwimmbad",
|
||||
12 => "Schwimmbad/Photovoltaik",
|
||||
13 => "Heizen_Ext_En",
|
||||
14 => "Brauchw_Ext_En",
|
||||
16 => "Durchflussueberwachung",
|
||||
@ -686,17 +690,37 @@ LUXTRONIK2_UpdateDone($)
|
||||
my $ambientTemperature = LUXTRONIK2_CalcTemp($a[12]);
|
||||
my $averageAmbientTemperature = LUXTRONIK2_CalcTemp($a[13]);
|
||||
my $hotWaterTemperature = LUXTRONIK2_CalcTemp($a[14]);
|
||||
my $hotWaterTemperatureTarget = LUXTRONIK2_CalcTemp($a[25]);
|
||||
my $hotWaterTemperatureThreshold = LUXTRONIK2_CalcTemp($a[25] - $a[49]);
|
||||
my $thresholdHeatingLimit = LUXTRONIK2_CalcTemp($a[21]);
|
||||
my $thresholdTemperatureSetBack = LUXTRONIK2_CalcTemp($a[48]);
|
||||
my $flowTemperature = LUXTRONIK2_CalcTemp($a[15]);
|
||||
my $returnTemperature = LUXTRONIK2_CalcTemp($a[16]);
|
||||
|
||||
|
||||
# if selected, do all the statistic calculations
|
||||
if ( AttrVal($name,"doStatistics",0) == 1) {
|
||||
$value = LUXTRONIK2_doStatisticBoiler ($hash, $a[22], $a[37]/10, $hotWaterTemperature);
|
||||
if ( AttrVal($name,"doStatistics",0) == 1) {
|
||||
#LUXTRONIK2_doStatisticBoilerHeatUp $hash, $currOpHours, $currHQ, $currTemp, $opState, $target
|
||||
$value = LUXTRONIK2_doStatisticBoilerHeatUp ($hash, $a[35], $a[37]/10, $hotWaterTemperature, $a[3],$hotWaterTemperatureTarget);
|
||||
if ($value ne "") {
|
||||
readingsBulkUpdate($hash,"statGradientBoilerTempLoss",$value);
|
||||
Log3 $name,3,"$name: statGradientBoilerTempLoss set to $value"
|
||||
readingsBulkUpdate($hash,"statBoilerGradientHeatUp",$value);
|
||||
Log3 $name,3,"$name: statBoilerGradientHeatUp set to $value";
|
||||
}
|
||||
#LUXTRONIK2_doStatisticBoilerCoolDown $hash, $time, $currTemp, $opState, $target, $threshold
|
||||
$value = LUXTRONIK2_doStatisticBoilerCoolDown ($hash, $a[22], $hotWaterTemperature, $a[3], $hotWaterTemperatureTarget, $hotWaterTemperatureThreshold);
|
||||
if ($value ne "") {
|
||||
readingsBulkUpdate($hash,"statBoilerGradientCoolDown",$value);
|
||||
Log3 $name,3,"$name: statBoilerGradientCoolDown set to $value";
|
||||
if ( exists( $hash->{READINGS}{statBoilerGradientCoolDownMin} ) ) {
|
||||
my @new = split / /, $value;
|
||||
my @old = split / /, $hash->{READINGS}{statBoilerGradientCoolDownMin};
|
||||
if ($new[5]>6 && $new[0]<$old[0]) {
|
||||
readingsBulkUpdate($hash,"statBoilerGradientCoolDownMin",$value);
|
||||
Log3 $name,3,"$name: statBoilerGradientCoolDownMin set to $value";
|
||||
}
|
||||
} else {
|
||||
readingsBulkUpdate($hash,"statBoilerGradientCoolDownMin",$value);
|
||||
Log3 $name,3,"$name: statBoilerGradientCoolDownMin set to $value";
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
@ -786,7 +810,7 @@ LUXTRONIK2_UpdateDone($)
|
||||
readingsBulkUpdate( $hash, "thresholdHeatingLimit", $thresholdHeatingLimit);
|
||||
readingsBulkUpdate( $hash, "thresholdTemperatureSetBack", $thresholdTemperatureSetBack);
|
||||
readingsBulkUpdate( $hash, "hotWaterTemperature", $hotWaterTemperature);
|
||||
readingsBulkUpdate( $hash, "hotWaterTemperatureTarget",LUXTRONIK2_CalcTemp($a[25]));
|
||||
readingsBulkUpdate( $hash, "hotWaterTemperatureTarget",$hotWaterTemperatureTarget);
|
||||
readingsBulkUpdate( $hash, "flowTemperature", $flowTemperature);
|
||||
readingsBulkUpdate( $hash, "returnTemperature", $returnTemperature);
|
||||
readingsBulkUpdate( $hash, "returnTemperatureTarget",LUXTRONIK2_CalcTemp($a[17]));
|
||||
@ -830,10 +854,9 @@ LUXTRONIK2_UpdateDone($)
|
||||
if ($a[36]>0) {readingsBulkUpdate($hash,"counterHeatQHeating",$a[36]/10);}
|
||||
if ($a[37]>0) {readingsBulkUpdate($hash,"counterHeatQHotWater",$a[37]/10);}
|
||||
if ($a[36]+$a[37]>0) {readingsBulkUpdate($hash,"counterHeatQTotal",($a[36]+$a[37])/10);}
|
||||
#WM[kW] = Wäremekapazität * (TVL-TRL) * Durchfluss [ccm/s]
|
||||
$value = 4.18 * ($flowTemperature-$returnTemperature) * $a[19] / 36000;
|
||||
$value = floor( 10 * $value + 0.5) / 10;
|
||||
readingsBulkUpdate( $hash, "currentThermalOutput", $value);
|
||||
#WM[kW] = delta_Temp [K] * Durchfluss [l/h] / ( 3.600 [kJ/kWh] / ( 4,179 [kJ/(kg*K)] (H2O Wärmekapazität bei 30 & 40°C) * 0,994 [kg/l] (H2O Dichte bei 35°C) )
|
||||
$value = ($flowTemperature-$returnTemperature) * $a[19] / 866.65;
|
||||
readingsBulkUpdate( $hash, "currentThermalOutput", sprintf("%.1f", $value));
|
||||
|
||||
# HTML for floorplan
|
||||
if(AttrVal($name, "statusHTML", "none") ne "none") {
|
||||
@ -1074,87 +1097,168 @@ LUXTRONIK2_checkFirmware ($)
|
||||
}
|
||||
}
|
||||
|
||||
# Calculate hourly gradients of boiler based on hotWaterTemperature and counterHeatQHeating
|
||||
# Calculate heat-up gradients of boiler based on hotWaterTemperature and counterHeatQHeating
|
||||
sub ########################################
|
||||
LUXTRONIK2_doStatisticBoiler ($$$$)
|
||||
LUXTRONIK2_doStatisticBoilerHeatUp ($$$$$$)
|
||||
{
|
||||
|
||||
my ($hash,$time,$currHQ,$currTemp) = @_;
|
||||
my ($hash, $currOpHours, $currHQ, $currTemp, $opState, $target) = @_;
|
||||
my $name = $hash->{NAME};
|
||||
my $statModeHW = $hash->{fhem}{statModeHotWater};
|
||||
my $minTemp = $hash->{fhem}{statHotWaterTempMin};
|
||||
my $maxTemp = $hash->{fhem}{statHotWaterTempMax};
|
||||
my $lastHQ = $hash->{fhem}{statHQHotWater};
|
||||
my $step = $hash->{fhem}{statBoilerHeatUpStep};
|
||||
my $minTemp = $hash->{fhem}{statBoilerHeatUpMin};
|
||||
my $maxTemp = $hash->{fhem}{statBoilerHeatUpMax};
|
||||
my $lastHQ = $hash->{fhem}{statBoilerHeatUpHQ};
|
||||
my $lastOpHours = $hash->{fhem}{statBoilerHeatUpOpHours};
|
||||
my $value1 = 0;
|
||||
my $value2 = 0;
|
||||
my $value3 = 0;
|
||||
my $returnStr = "";
|
||||
|
||||
# step 0 = Initialize - if hot water preparation is off
|
||||
if ($step == 0) {
|
||||
if ($opState != 5) { # wait till hot water preparation stopped
|
||||
Log3 $name, 4, "$name: Statistic Boiler Heat-Up step 0->1: Initializing Measurment";
|
||||
$step = 1;
|
||||
$lastOpHours = $currOpHours;
|
||||
$lastHQ = $currHQ;
|
||||
$minTemp = $currTemp;
|
||||
}
|
||||
|
||||
# step 1 = wait till hot water preparation starts -> monitor Tmin, take previous HQ and previous operating hours
|
||||
} elsif ($step == 1) {
|
||||
if ($currTemp < $minTemp) { # monitor minimum temperature
|
||||
Log3 $name, 4, "$name: Statistic Boiler Heat-Up step 1: Monitor minimum temperature ($minTemp -> $currTemp)";
|
||||
$minTemp = $currTemp;
|
||||
}
|
||||
if ($opState != 5) { # wait -> update operating hours and HQ to be used as start value in calculations
|
||||
$lastOpHours = $currOpHours;
|
||||
$lastHQ = $currHQ;
|
||||
} else { # go to step 2 - if hot water preparation running
|
||||
Log3 $name, 4, "$name: Statistic Boiler Heat-Up step 1->2: Hot water preparation started ".($currOpHours-$lastOpHours)." s ago";
|
||||
$step = 2;
|
||||
$maxTemp = $currTemp;
|
||||
}
|
||||
|
||||
# step 2 = wait till hot water preparation done and target reached
|
||||
} elsif ($step == 2) {
|
||||
if ($currTemp < $minTemp) { # monitor minimal temperature
|
||||
Log3 $name, 4, "$name: Statistic Boiler Heat-Up step 2: Boiler temperature still decreasing ($minTemp -> $currTemp)";
|
||||
$minTemp = $currTemp;
|
||||
}
|
||||
if ($currTemp > $maxTemp) { # monitor maximal temperature
|
||||
Log3 $name, 4, "$name: Statistic Boiler Heat-Up step 2: Boiler temperature increasing ($maxTemp -> $currTemp)";
|
||||
$maxTemp = $currTemp;
|
||||
}
|
||||
|
||||
if ($opState != 5) { # wait till hot water preparation stopped
|
||||
if ($currTemp >= $target) {
|
||||
Log3 $name, 4, "$name: Statistic Boiler Heat-Up step 2->3: Hot water preparation stopped";
|
||||
$step = 3;
|
||||
} else {
|
||||
Log3 $name, 4, "$name: Statistic Boiler Heat-Up step 2->1: Measurement cancelled (hot water preparation stopped but target not reached, $currTemp < $target)";
|
||||
$step = 1;
|
||||
$lastOpHours = $currOpHours;
|
||||
$lastHQ = $currHQ;
|
||||
$minTemp = $currTemp;
|
||||
}
|
||||
}
|
||||
|
||||
# step 3 = wait with calculation till temperature maximum reached once
|
||||
} elsif ($step == 3) {
|
||||
# cancel measurement - if hot water preparation has restarted
|
||||
if ($opState == 5) {
|
||||
Log3 $name, 4, "$name: Statistic Boiler Heat-Up step 3->0: Measurement cancelled (hot water preparation restarted before maximum reached)";
|
||||
$step = 0;
|
||||
# monitor maximal temperature
|
||||
} elsif ($currTemp > $maxTemp) {
|
||||
Log3 $name, 4, "$name: Statistic Boiler Heat-Up step 3: Temperature still increasing ($maxTemp -> $currTemp)";
|
||||
$maxTemp = $currTemp;
|
||||
# else calculate temperature gradient
|
||||
} else {
|
||||
Log3 $name, 4, "$name: Statistic Boiler Heat-Up step 3->1: Boiler heat-up measurement finished";
|
||||
$value1 = ( int(10 * $maxTemp) - int(10 * $minTemp) ) / 10; # delta hot water temperature
|
||||
$value2 = ( $currOpHours - $lastOpHours ) / 60; # delta time (minutes)
|
||||
# $value3 = floor(100 * $value1 / $value2 + 0.5) / 100; # Temperature gradient over time rounded to 1/100th
|
||||
# $value2 = floor(100 * $value2 + 0.5) / 100; # rounded to 1/100th
|
||||
$returnStr = "DT/min: ".sprintf("%.2f", $value1/$value2)." DT: ".sprintf("%.2f", $value1)." Dmin: ".sprintf("%.0f", $value2);
|
||||
|
||||
$value2 = $currHQ - $lastHQ; # delta heat quantity
|
||||
# $value2 = floor(10*($currHQ - $lastHQ)+0.5)/10; # delta heat quantity
|
||||
# $value3 = floor(100 * $value2 / $value1 + 0.5) / 100; # heat gradient over temperature rounded to 1/100th
|
||||
$returnStr .= " DQ/T: ".sprintf("%.2f",$value2/$value1)." DQ: ".sprintf("%.1f",$value2);
|
||||
|
||||
#Volumen [l] = Wärmemenge [kWh] / (delta T) [K] * ( 3.600 [kJ/kWh] / ( 4,179 [kJ/(kg*K)] (H2O Wärmekapazität bei 40°C) * 0,992 [kg/l] (H2O Dichte bei 40°C) ) [K/(kWh*l)] )
|
||||
$value3 = 868.4 * $value2 / $value1 ; # heated water volume in liter
|
||||
$returnStr .= " DV: ".sprintf("%.0f",$value3);
|
||||
|
||||
$step = 1;
|
||||
$lastOpHours = $currOpHours;
|
||||
$lastHQ = $currHQ;
|
||||
$minTemp = $currTemp;
|
||||
|
||||
}
|
||||
}
|
||||
$hash->{fhem}{statBoilerHeatUpStep} = $step;
|
||||
$hash->{fhem}{statBoilerHeatUpMin} = $minTemp;
|
||||
$hash->{fhem}{statBoilerHeatUpMax} = $maxTemp;
|
||||
$hash->{fhem}{statBoilerHeatUpHQ} = $lastHQ;
|
||||
$hash->{fhem}{statBoilerHeatUpOpHours} = $lastOpHours;
|
||||
|
||||
return $returnStr;
|
||||
|
||||
}
|
||||
|
||||
# Calculate heat loss gradients of boiler based on hotWaterTemperature and counterHeatQHeating
|
||||
sub ########################################
|
||||
LUXTRONIK2_doStatisticBoilerCoolDown ($$$$$$)
|
||||
{
|
||||
my ($hash, $time, $currTemp, $opState, $target, $threshold) = @_;
|
||||
my $name = $hash->{NAME};
|
||||
my $step = $hash->{fhem}{statBoilerCoolDownStep};
|
||||
my $maxTemp = $hash->{fhem}{statBoilerCoolDownMax};
|
||||
my $startTime = $hash->{fhem}{statBoilerCoolDownStartTime};
|
||||
my $value1 = 0;
|
||||
my $value2 = 0;
|
||||
my $value3 = 0;
|
||||
|
||||
# mode 0 = init hot water gradient calculation
|
||||
if ($statModeHW == 0) { # -> Mode 1
|
||||
Log3 $name, 4, "$name: Boiler statMode 0: Initialized";
|
||||
$hash->{fhem}{statModeHotWater} = 1;
|
||||
$hash->{fhem}{statStartTimeHotWater} = $time;
|
||||
$hash->{fhem}{statHQHotWater} = $currHQ;
|
||||
$hash->{fhem}{statHotWaterTempMax} = $currTemp;
|
||||
$hash->{fhem}{statHotWaterTempMin} = $currTemp;
|
||||
|
||||
# mode 1 = wait till maximum of temperature is reached
|
||||
} elsif ($statModeHW == 1) {
|
||||
# wait until heat quantity does not change anymore
|
||||
if ($lastHQ != $currHQ) {
|
||||
Log3 $name, 4, "$name: Boiler statMode 1: Heat Quantity changed ($lastHQ -> $currHQ)";
|
||||
$hash->{fhem}{statHQHotWater} = $currHQ;
|
||||
$hash->{fhem}{statHotWaterTempMax} = $currTemp;
|
||||
# and temperature is not rising anymore
|
||||
} elsif ($maxTemp < $currTemp) {
|
||||
Log3 $name, 4, "$name: Boiler statMode 1: Temperature increased ($maxTemp < $currTemp)";
|
||||
$hash->{fhem}{statHotWaterTempMax} = $currTemp;
|
||||
# and temperature is starting to decrease -> Mode 2
|
||||
} elsif ($maxTemp - 0.2 > $currTemp) {
|
||||
$value1 = $maxTemp - $minTemp; # delta against last hot water temperature
|
||||
$value2 = ( $time - $hash->{fhem}{statStartTimeHotWater} ) / 60; # devided by delta time (minutes)
|
||||
$value3 = floor(100 * $value1 / $value2 + 0.5) / 100; # rounded to 1/100th
|
||||
$value2 = floor($value2 + 0.5); # rounded
|
||||
my $returnStr = "";
|
||||
|
||||
Log3 $name, 4, "$name: Boiler statMode 1: Measurement finished, start new measurement (maximum = $maxTemp )";
|
||||
$hash->{fhem}{statModeHotWater} = 2;
|
||||
$hash->{fhem}{statStartTimeHotWater} = $time;
|
||||
$hash->{fhem}{statHotWaterTempMin} = $currTemp;
|
||||
|
||||
return "DT/min: $value3 DT: $value1 Dmin: $value2";
|
||||
|
||||
# step 0 = Initialize - if hot water preparation is off and target reached,
|
||||
if ($step == 0) {
|
||||
if ($opState == 5 || $currTemp < $target) { # -> stay step 0
|
||||
# Log3 $name, 4, "$name: Statistic Boiler Cool-Down step 0: Wait till hot water preparation stops and target is reached ($currTemp < $target)";
|
||||
} else {
|
||||
Log3 $name, 4, "$name: Boiler statMode 1: Wait till temperature decreases (".($maxTemp-0.2)." <= $currTemp <= ".$maxTemp.")";
|
||||
Log3 $name, 4, "$name: Statistic Boiler Cool-Down step 0->1: Initializing, target reached ($currTemp >= $target)";
|
||||
$step = 1;
|
||||
$startTime = $time;
|
||||
$maxTemp = $currTemp;
|
||||
}
|
||||
|
||||
# mode 2 = wait till heat quantity changes or minimum of temperature reached
|
||||
} elsif ($statModeHW == 2) {
|
||||
# wait until heat quantity changes or temperature is raising again
|
||||
if ($hash->{fhem}{statHQHotWater} != $currHQ
|
||||
|| $minTemp + 0.2 < $currTemp) { # wait till change of heat quantity or rising temperature -> Mode 1
|
||||
Log3 $name, 4, "$name: Boiler statMode 2: Heat quantiy changed or temperature raised ($lastHQ != $currHQ or $minTemp +0.2 < $currTemp)";
|
||||
$value1 = $minTemp - $maxTemp; # delta against last hot water temperature
|
||||
$value2 = ( $time - $hash->{fhem}{statStartTimeHotWater} ) / 3600; # devided by delta time (hours)
|
||||
$value3 = floor(100 * $value1 / $value2 + 0.5) / 100; # rounded to 1/100th
|
||||
$value2 = floor(100 * $value2 + 0.5) / 100; # rounded to 1/100th
|
||||
Log3 $name, 4, "$name: Boiler statMode 2: Measurement finished, start new measurment (minimum = $minTemp)";
|
||||
|
||||
$hash->{fhem}{statModeHotWater} = 1;
|
||||
$hash->{fhem}{statStartTimeHotWater} = $time;
|
||||
$hash->{fhem}{statHotWaterTempMax} = $currTemp;
|
||||
$hash->{fhem}{statHQHotWater} = $currHQ;
|
||||
|
||||
return "DT/h: $value3 DT: $value1 Dh: $value2";
|
||||
|
||||
} elsif ($minTemp > $currTemp) {
|
||||
Log3 $name, 4, "$name: Boiler statMode 2: Temperature decreased ($minTemp > $currTemp)";
|
||||
$hash->{fhem}{statHotWaterTempMin} = $currTemp;
|
||||
} else {
|
||||
Log3 $name, 4, "$name: Boiler statMode 2: Monitoring temperature change ($minTemp <= $currTemp <= ".($minTemp+0.2).")";
|
||||
# step 1 = wait till threshold is reached -> do calculation, monitor maximal temperature
|
||||
} elsif ($step == 1) {
|
||||
if ($currTemp > $maxTemp) { # monitor maximal temperature
|
||||
Log3 $name, 4, "$name: Statistic Boiler Cool-Down step 1: Temperature still increasing ($currTemp > $maxTemp)";
|
||||
$maxTemp = $currTemp;
|
||||
$startTime = $time;
|
||||
}
|
||||
}
|
||||
|
||||
return "";
|
||||
if ($opState == 5) {
|
||||
Log3 $name, 4, "$name: Statistic Boiler Cool-Down step 1: Measurement cancelled (restart of hot water preparation)";
|
||||
$step = 0;
|
||||
} elsif ($currTemp <= $threshold) {
|
||||
Log3 $name, 4, "$name: Statistic Boiler Cool-Down step 2->1: Measurement finished, threshold reached ($currTemp <= $threshold)";
|
||||
$value1 = ( int(10 * $currTemp) - int(10 * $maxTemp) ) / 10; # delta hot water temperature
|
||||
$value2 = ( $time - $startTime ) / 3600; # delta time (hours)
|
||||
$value3 = floor(100 * $value1 / $value2 + 0.5) / 100; # Temperature gradient over time rounded to 1/100th
|
||||
$value2 = floor(100 * $value2 + 0.5) / 100; # rounded to 1/100th
|
||||
$returnStr = "DT/h: $value3 DT: $value1 Dh: $value2";
|
||||
|
||||
$step = 0;
|
||||
}
|
||||
}
|
||||
|
||||
$hash->{fhem}{statBoilerCoolDownStep} = $step;
|
||||
$hash->{fhem}{statBoilerCoolDownMax} = $maxTemp;
|
||||
$hash->{fhem}{statBoilerCoolDownStartTime} = $startTime;
|
||||
|
||||
return $returnStr;
|
||||
}
|
||||
|
||||
|
||||
@ -1166,7 +1270,7 @@ LUXTRONIK2_doStatisticBoiler ($$$$)
|
||||
<a name="LUXTRONIK2"></a>
|
||||
<h3>LUXTRONIK2</h3>
|
||||
<ul>
|
||||
Luxtronik 2.0 is a heating controller used in Alpha Innotec and Siemens Novelan (WPR NET) heat pumps.
|
||||
Luxtronik 2.0 is a heating controller used in Alpha Innotec and Siemens Novelan (WPR NET) heat pumps.<br>
|
||||
It has a built-in ethernet port, so it can be directly integrated into a local area network (LAN).
|
||||
<br>
|
||||
<i>The modul is reported to work with firmware: V1.54C, V1.60, V1.69.</i>
|
||||
@ -1187,12 +1291,16 @@ LUXTRONIK2_doStatisticBoiler ($$$$)
|
||||
<a name="LUXTRONIK2set"></a>
|
||||
<b>Set</b><br>
|
||||
<ul>A firmware check assures before each set operation that a heat pump with untested firmware is not damaged accidently.
|
||||
<li>opModeHotWater <Mode>- Operating Mode of domestic hot water boiler (Auto | Party | Off)</li>
|
||||
<li>hotWaterTemperatureTarget <temperature> - Target temperature of domestic hot water boiler in °C</li>
|
||||
<li>INTERVAL <polling interval> - Polling interval in seconds</li>
|
||||
<li>statusRequest - Update device information</li>
|
||||
<li>synchClockHeatPump - Synchronizes controller clock with FHEM time.<br>
|
||||
<b>!! This change is lost in case of controller power off!!</b></li>
|
||||
<li><code>opModeHotWater <Mode></code><br>
|
||||
Operating Mode of domestic hot water boiler (Auto | Party | Off)</li>
|
||||
<li><code>hotWaterTemperatureTarget <temperature></code><br>
|
||||
Target temperature of domestic hot water boiler in °C</li>
|
||||
<li><code>INTERVAL <polling interval></code><br>
|
||||
Polling interval in seconds</li>
|
||||
<li><code>statusRequest</code><br>
|
||||
Update device information</li>
|
||||
<li><code>synchClockHeatPump</code><br>
|
||||
Synchronizes controller clock with FHEM time. <b>!! This change is lost in case of controller power off!!</b></li>
|
||||
</ul>
|
||||
<br>
|
||||
<a name="LUXTRONIK2get"></a>
|
||||
@ -1205,17 +1313,17 @@ LUXTRONIK2_doStatisticBoiler ($$$$)
|
||||
<a name="LUXTRONIK2attr"></a>
|
||||
<b>Attributes</b>
|
||||
<ul>
|
||||
<li>statusHTML<br>
|
||||
<li><code>statusHTML</code><br>
|
||||
If set, a HTML-formatted reading named "floorplanHTML" is created. It can be used with the <a href="#FLOORPLAN">FLOORPLAN</a> module.<br>
|
||||
Currently, if the value of this attribute is not NULL, the corresponding reading consists of the current status of the heat pump and the temperature of the water.</li>
|
||||
<li>doStatistics < 0 | 1 ><br>
|
||||
Still Beta - Calculates statistic values: <i>statGradientBoilerTempLoss</i>
|
||||
<li>allowSetParameter < 0 | 1 ><br>
|
||||
<li><code>doStatistics < 0 | 1 ></code><br>
|
||||
Calculates statistic values: <i>statBoilerGradientHeatUp, statBoilerGradientCoolDown, statBoilerGradientCoolDownMin (boiler heat loss)</i></li>
|
||||
<li><code>allowSetParameter < 0 | 1 ></code><br>
|
||||
The <a href="#LUXTRONIK2set">parameters</a> of the heat pump controller can only be changed if this attribut is set to 1.</li>
|
||||
<li>autoSynchClock <delay><br>
|
||||
<li><code>autoSynchClock <delay></code><br>
|
||||
Corrects the clock of the heatpump automatically if a certain <i>delay</i> (10 s - 600 s) against the FHEM time is exeeded. Does a firmware check before.<br>
|
||||
<i>(A 'delayDeviceTimeCalc' <= 2 s can be caused by the internal calculation interval of the heat pump controller.)</i></li>
|
||||
<li>ignoreFirmwareCheck < 0 | 1 ><br>
|
||||
<li><code>ignoreFirmwareCheck < 0 | 1 ></code><br>
|
||||
A firmware check assures before each set operation that a heatpump controller with untested firmware is not damaged accidently.<br>
|
||||
If this attribute is set to 1, the firmware check is ignored and new firmware can be tested for compatibility.</li>
|
||||
<li><a href="#readingFnAttributes">readingFnAttributes</a></li>
|
||||
@ -1276,7 +1384,7 @@ LUXTRONIK2_doStatisticBoiler ($$$$)
|
||||
wenn gesetzt, dann wird ein HTML-formatierter Wert "floorplanHTML" erzeugt, welcher vom Modul <a href="#FLOORPLAN">FLOORPLAN</a> genutzt werden kann.<br>
|
||||
Momentan wird nur geprüft, ob der Wert dieses Attributes ungleich NULL ist, der entsprechende Gerätewerte besteht aus dem aktuellen Wärmepumpenstatus und der Heizwassertemperatur.</li>
|
||||
<li>doStatistics < 0 | 1 ><br>
|
||||
Noch im Versuchsstadium - Berechnet statistische Werte: <i>statGradientBoilerTempLoss</i>
|
||||
Berechnet statistische Werte: <i>statBoilerGradientHeatUp, statBoilerGradientCoolDown, statBoilerGradientCoolDownMin (Wärmeverlust des Boilers)</i></li>
|
||||
<li>allowSetParameter < 0 | 1 ><br>
|
||||
Die internen <a href="#LUXTRONIK2set">Parameter</a> der Wärmepumpensteuerung können nur geändert werden, wenn dieses Attribut auf 1 gesetzt ist.</li>
|
||||