# Date Who Comment
|
||||
# ---------- ------------- -------------------------------------------------------------------------------------------------------------------------------
|
||||
# 2016-03-20 RaspII Added some information to Commandref, now attrib contains correct information
|
||||
# 2016-01-30 RaspII Now also Blinds and Switches are implemented (all actuators I have).
|
||||
# 2016-01-12 RaspII Implemented Dimmer Commands for 1&3 key remote, removed toggle
|
||||
# 2015-06-02 RaspII Now can also Handle multiple devices with same code, next step: implement all commands (on, off, toggle... for KOPP_FC_Parse)
|
||||
@ -788,9 +789,19 @@ if( $msg =~ m/^kr/ ) { # if first two char's are "kr" then we
|
||||
The Kopp Free Control protocol is used by Kopp receivers/actuators and senders.
|
||||
This module is able to send commands to Kopp actuators and receive commands from Kopp transmitters. Currently supports devices: dimmers, switches and blinds.
|
||||
The communication is done via a <a href="#CUL">CUL</a> or compatible device (e.g. CCD...).
|
||||
This devices must be defined before using this protocol (e.g. "define CUL_0 CUL /dev/ttyAMA0@38400 1234" and "attr CUL_0 rfmode KOPP_FC" ).
|
||||
This devices must be defined before using this protocol.
|
||||
|
||||
<br><br>
|
||||
<b>Assign the Kopp Free Control protocol to a CUL or compatible device</b>
|
||||
<ul>
|
||||
<code>define CUL_0 CUL /dev/ttyAMA0@38400 1234</code><br>
|
||||
<code>attr CUL_0 rfmode KOPP_FC</code>
|
||||
<br>
|
||||
This attribute ("rfmode KOPP_FC") assigns the Kopp protocol to device CUL_0<br>
|
||||
You may <b>not</b> assign/use a second protocol on this device
|
||||
<br>
|
||||
</ul>
|
||||
<br>
|
||||
<a name="KOPP_FCdefine"></a>
|
||||
<b>Define</b>
|
||||
<ul>
|
||||
@ -830,6 +841,7 @@ if( $msg =~ m/^kr/ ) { # if first two char's are "kr" then we
|
||||
You are now able to control the receiver from FHEM, the receiver handles FHEM just linke another remote control.
|
||||
</ul>
|
||||
|
||||
<br>
|
||||
<a name="KOPP_FCset"></a>
|
||||
<b>Set</b>
|
||||
<ul>
|
||||
@ -846,42 +858,68 @@ if( $msg =~ m/^kr/ ) { # if first two char's are "kr" then we
|
||||
</ul>
|
||||
|
||||
<pre>Examples:
|
||||
<code>set DimmerDevice on</code> # will toggle dimmer device (e.g. lamp) on/off
|
||||
<code>set DimmerDevice dimm</code> # will start dimming process
|
||||
<code>set DimmerDevice stop</code> # will stop dimming process
|
||||
<code>set Dimmer on</code> # will toggle dimmer device on/off for 1Key remote control,
|
||||
<code> </code> will switch on for 3 key remote control
|
||||
<code>set Dimmer off</code> # will switch dimmer device off (3 key remote control)
|
||||
<code>set Dimmer dimm</code> # will start dimming process
|
||||
<code>set Dimmer stop</code> # will stop dimming process
|
||||
</pre>
|
||||
</ul>
|
||||
<br>
|
||||
|
||||
<a name="KOPP_FCattrib"></a>
|
||||
<b>Attributes</b>
|
||||
<ul>
|
||||
<code>attr CUL_0 rfmode KOPP_FC</code>
|
||||
<code>attr <name> model <value></code>
|
||||
<br>
|
||||
|
||||
This attribute will switch the Kopp protocol on for device CUL_0<br>
|
||||
You can not use a second protocol on this device
|
||||
<br><li><code><value></code></li>
|
||||
value is one of:
|
||||
<ul>
|
||||
<code>Switch_8080_01</code><br>
|
||||
<code>Switch_8080_01_2Key</code><br>
|
||||
<code>Blind_8080_02</code><br>
|
||||
<code>Timer_8080_04</code><br>
|
||||
<code>Dimm_8011_00</code><br>
|
||||
<code>Dimm_8011_00_3Key</code><br>
|
||||
</ul>
|
||||
|
||||
</ul>
|
||||
<br>
|
||||
|
||||
<br><br>Example: FHEM Config for Dimmer via 1 Key remote control:
|
||||
<b>Examples</b>
|
||||
|
||||
<ul>
|
||||
<br>FHEM Config for Dimmer via 1 Key remote control:
|
||||
<ul>
|
||||
<code>define Dimmer KOPP_FC 65 FA5E 02</code><br>
|
||||
<code>attr Dimmer IODev CCD</code><br>
|
||||
<code>attr Dimmer IODev CUL_0</code><br>
|
||||
<code>attr Dimmer devStateIcon OnOff:toggle:dimm dimm:dim50%:stop stop:on:dimm off:toggle:dimm</code><br>
|
||||
<code>attr Dimmer eventMap on:OnOff dimm:dimm stop:stop</code><br>
|
||||
<code>attr Dimmer group Dimmer_1KeyMode</code><br>
|
||||
<code>attr Dimmer group TestGroup</code><br>
|
||||
<code>attr Dimmer model Dimm_8011_00</code><br>
|
||||
<code>attr Dimmer room Test</code><br>
|
||||
<code>attr Dimmer room TestRoom</code><br>
|
||||
<code>attr Dimmer webCmd OnOff:dimm:stop</code><br>
|
||||
</ul>
|
||||
</ul>
|
||||
|
||||
<br><br>Example: FHEM Config for Dimmer via 3 Key remote control:
|
||||
<br>FHEM Config for Dimmer via 3 Key remote control:
|
||||
<ul>
|
||||
<code>define SDimmer KOPP_FC 65 FA5E 02 55 75</code><br>
|
||||
<code>attr SDimmer IODev CUL_0</code><br>
|
||||
<code>attr SDimmer devStateIcon dimm:dim50%:stop stop:on:off on:on:off off:off:on</code><br>
|
||||
<code>attr SDimmer group TestGroup</code><br>
|
||||
<code>attr SDimmer icon light_pendant_light</code><br>
|
||||
<code>attr SDimmer model Dimm_8011_00_3Key</code><br>
|
||||
<code>attr SDimmer room TestRoom</code><br>
|
||||
<code>attr SDimmer webCmd on:dimm:stop:off</code><br>
|
||||
</ul>
|
||||
</ul>
|
||||
|
||||
<br>
|
||||
<br><br>
|
||||
<b>Additional Information you can find in corresponding FHEM Wiki</b>
|
||||
<ul><li><a href="http://www.fhemwiki.de/w/index.php?title=Kopp_Allgemein&redirect=no">Kopp Allgemein</a></li></ul>
|
||||
<br><br>
|
||||
|
||||
</ul>
|
||||
|
||||
</ul>
|
||||
|
||||
|
||||
=end html
|
||||
|
Loading…
x
Reference in New Issue
Block a user