2
0
mirror of https://github.com/fhem/fhem-mirror.git synced 2025-04-29 23:47:10 +00:00

70_PylonLowVoltage: edit commandref

git-svn-id: https://svn.fhem.de/fhem/trunk@28685 2b470e98-0d58-463d-a4d8-8e2adae1ed80
This commit is contained in:
nasseeder1 2024-03-19 20:55:49 +00:00
parent 4a04b348a7
commit e1fa53a080
2 changed files with 280 additions and 214 deletions

View File

@ -1,5 +1,6 @@
# Add changes at the top of the list. Keep it in ASCII, and 80-char wide.
# Do not insert empty lines here, update check depends on it.
- change: 70_PylonLowVoltage: edit commandref
- feature: 93_DbLog: support of MariaDB driver and more, see Forum:#137480
- feature: 93_DbRep: sqlCmdBlocking can use sql Keywords §timestamp_end§ etc.
- change: 93_DbRep: prevent some attr eval as long as init_done is not set

View File

@ -122,6 +122,7 @@ BEGIN {
# Versions History intern (Versions history by Heiko Maaz)
my %vNotesIntern = (
"0.2.3" => "19.03.2024 edit commandref ",
"0.2.2" => "20.02.2024 correct commandref ",
"0.2.1" => "18.02.2024 doOnError: print out faulty response, Forum:https://forum.fhem.de/index.php?msg=1303912 ",
"0.2.0" => "15.12.2023 extend possible number of batteries up to 14 ",
@ -1551,6 +1552,38 @@ The data format must be set on the RS485 gateway as follows:
</ul>
<br>
<b>Example configuration of a Waveshare RS485 to Ethernet converter</b>
<br><br>
The converter's web interface offers several pages with settings. The relevant settings are shown below
as an example. The assignment of a fixed IP address is assumed in advance.
<br>
<ul>
<table>
<colgroup> <col width="25%"> <col width="75%"> </colgroup>
<tr><td> <b>Serial port settings</b> </td><td> </td></tr>
<tr><td> - Baud Rate </td><td>: according to the battery setting </td></tr>
<tr><td> - Data Size </td><td>: 8 Bit </td></tr>
<tr><td> - Parity </td><td>: None </td></tr>
<tr><td> - Stop Bits </td><td>: 1 </td></tr>
<tr><td> - Local Port Number </td><td>: freely selected </td></tr>
<tr><td> - Work Mode </td><td>: TCP Server </td></tr>
<tr><td> - Reset </td><td>: not set </td></tr>
<tr><td> - Link </td><td>: set </td></tr>
<tr><td> - Index </td><td>: not set </td></tr>
<tr><td> - Similar RCF2217 </td><td>: set </td></tr>
<tr><td> </td><td> </td></tr>
<tr><td> <b>Settings Expand Function</b> </td><td> </td></tr>
<tr><td> - Heartbeat Packet Type </td><td>: None </td></tr>
<tr><td> - Register Packet Type </td><td>: None </td></tr>
<tr><td> - Short Connection </td><td>: not set </td></tr>
<tr><td> - TCP Server-kick off old connection </td><td>: set </td></tr>
<tr><td> - Buffer Data before Connected </td><td>: set </td></tr>
<tr><td> - UART Set Parameter </td><td>: not set </td></tr>
</table>
</ul>
<br>
<b>Limitations</b>
<br>
The module currently supports a maximum of 14 batteries (master + 13 slaves) in one group.
@ -1742,6 +1775,38 @@ Das Datenformat muß auf dem RS485 Gateway wie folgt eingestellt werden:
</ul>
<br>
<b>Beispielkonfiguration eines Waveshare RS485 to Ethernet Converters</b>
<br><br>
Das Webinterface des Konverters bietet mehrere Seiten mit Einstellungen an. Die relevanten Einstellungen sind nachfolgend
beispielhaft gezeigt. Die Zuweisung einer festen IP-Adresse wird vorab vorausgesetzt.
<br>
<ul>
<table>
<colgroup> <col width="25%"> <col width="75%"> </colgroup>
<tr><td> <b>Einstellungen Serial Port</b> </td><td> </td></tr>
<tr><td> - Baud Rate </td><td>: entsprechend Einstellung der Batterie </td></tr>
<tr><td> - Data Size </td><td>: 8 Bit </td></tr>
<tr><td> - Parity </td><td>: None </td></tr>
<tr><td> - Stop Bits </td><td>: 1 </td></tr>
<tr><td> - Local Port Number </td><td>: frei gewählt </td></tr>
<tr><td> - Work Mode </td><td>: TCP Server </td></tr>
<tr><td> - Reset </td><td>: nicht gesetzt </td></tr>
<tr><td> - Link </td><td>: gesetzt </td></tr>
<tr><td> - Index </td><td>: nicht gesetzt </td></tr>
<tr><td> - Similar RCF2217 </td><td>: gesetzt </td></tr>
<tr><td> </td><td> </td></tr>
<tr><td> <b>Einstellungen Expand Function</b> </td><td> </td></tr>
<tr><td> - Heartbeat Packet Type </td><td>: None </td></tr>
<tr><td> - Register Packet Type </td><td>: None </td></tr>
<tr><td> - Short Connection </td><td>: nicht gesetzt </td></tr>
<tr><td> - TCP Server-kick off old connection </td><td>: gesetzt </td></tr>
<tr><td> - Buffer Data before Connected </td><td>: gesetzt </td></tr>
<tr><td> - UART Set Parameter </td><td>: nicht gesetzt </td></tr>
</table>
</ul>
<br>
<b>Einschränkungen</b>
<br>
Das Modul unterstützt zur Zeit maximal 14 Batterien (Master + 13 Slaves) in einer Gruppe.