70_PylonLowVoltage: contrib 0.2.5
git-svn-id: https://svn.fhem.de/fhem/trunk@28732 2b470e98-0d58-463d-a4d8-8e2adae1ed80
This commit is contained in:
parent
a074e0d205
commit
d39bf78827
@ -122,6 +122,10 @@ BEGIN {
|
||||
|
||||
# Versions History intern (Versions history by Heiko Maaz)
|
||||
my %vNotesIntern = (
|
||||
"0.2.5" => "01.04.2024 _callAnalogValue: more than 5 temperature positions (US5000) ",
|
||||
"0.2.4" => "29.03.2024 avoid possible Illegal division by zero at line 1438 ",
|
||||
"0.2.3" => "19.03.2024 edit commandref ",
|
||||
"0.2.2" => "20.02.2024 correct commandref ",
|
||||
"0.2.1" => "18.02.2024 doOnError: print out faulty response, Forum:https://forum.fhem.de/index.php?msg=1303912 ",
|
||||
"0.2.0" => "15.12.2023 extend possible number of batteries up to 14 ",
|
||||
"0.1.11" => "28.10.2023 add needed data format to commandref ",
|
||||
@ -1152,11 +1156,11 @@ sub _callAnalogValue {
|
||||
|
||||
for my $z (1..$pcc) {
|
||||
my $fz = sprintf "%02d", $z; # formatierter Zähler
|
||||
$readings->{'cellVoltage_'.$fz} = sprintf "%.3f", hex(substr($res, $bpos, 4)) / 1000; # Pos 19 - 75 bei 15 Zellen
|
||||
$readings->{'cellVoltage_'.$fz} = sprintf "%.3f", hex(substr($res, $bpos, 4)) / 1000; # Pos 19 -> 75 bei 15 Zellen
|
||||
$bpos += 4; # letzter Durchlauf: Pos 79 bei 15 Zellen, Pos 83 bei 16 Zellen
|
||||
}
|
||||
|
||||
$readings->{numberTempPos} = hex(substr($res, $bpos, 2)); # Anzahl der jetzt folgenden Teperaturpositionen -> 5
|
||||
$readings->{numberTempPos} = hex(substr($res, $bpos, 2)); # Anzahl der jetzt folgenden Temperaturpositionen -> 5 oder mehr (US5000: 6)
|
||||
$bpos += 2;
|
||||
|
||||
$readings->{bmsTemperature} = (hex (substr($res, $bpos, 4)) - 2731) / 10; # Pos 81 bei 15 Zellen
|
||||
@ -1174,7 +1178,13 @@ sub _callAnalogValue {
|
||||
$readings->{'cellTemperature_13'.$pcc} = (hex (substr($res, $bpos, 4)) - 2731) / 10; # Pos 97
|
||||
$bpos += 4;
|
||||
|
||||
my $current = hex (substr($res, $bpos, 4)); # Pos 101
|
||||
for my $t (6..$readings->{numberTempPos}) {
|
||||
$t = 'add'.sprintf "%02d", $t;
|
||||
$readings->{'cellTemperature_'.$t} = (hex (substr($res, $bpos, 4)) - 2731) / 10; # mehr als 5 Temperaturpositionen (z.B. US5000)
|
||||
$bpos += 4;
|
||||
}
|
||||
|
||||
my $current = hex (substr($res, $bpos, 4)); # Pos 101 (bei 5 Temperaturpositionen)
|
||||
$bpos += 4;
|
||||
|
||||
$readings->{packVolt} = sprintf "%.3f", hex (substr($res, $bpos, 4)) / 1000; # Pos 105
|
||||
@ -1432,8 +1442,8 @@ sub additionalReadings {
|
||||
|
||||
my ($vmax, $vmin);
|
||||
|
||||
$readings->{averageCellVolt} = sprintf "%.3f", $readings->{packVolt} / $readings->{packCellcount} if(defined $readings->{packCellcount});
|
||||
$readings->{packSOC} = sprintf "%.2f", ($readings->{packCapacityRemain} / $readings->{packCapacity} * 100) if(defined $readings->{packCapacity});
|
||||
$readings->{averageCellVolt} = sprintf "%.3f", $readings->{packVolt} / $readings->{packCellcount} if($readings->{packCellcount});
|
||||
$readings->{packSOC} = sprintf "%.2f", ($readings->{packCapacityRemain} / $readings->{packCapacity} * 100) if($readings->{packCapacity});
|
||||
$readings->{packPower} = sprintf "%.2f", $readings->{packCurrent} * $readings->{packVolt};
|
||||
|
||||
for (my $i=1; $i <= $readings->{packCellcount}; $i++) {
|
||||
@ -1503,41 +1513,41 @@ return;
|
||||
|
||||
=begin html
|
||||
|
||||
<a id="PylonLowVoltage"></a>
|
||||
<h3>PylonLowVoltage</h3>
|
||||
<br>
|
||||
Module for integration of low voltage batteries with battery management system (BMS) of the manufacturer Pylontech via
|
||||
RS485/Ethernet gateway. Communication to the RS485 gateway takes place exclusively via an Ethernet connection.<br>
|
||||
The module has been successfully used so far with Pylontech batteries of the following types: <br>
|
||||
<a id="PylonLowVoltage"></a>
|
||||
<h3>PylonLowVoltage</h3>
|
||||
<br>
|
||||
Module for integration of low voltage batteries with battery management system (BMS) of the manufacturer Pylontech via
|
||||
RS485/Ethernet gateway. Communication to the RS485 gateway takes place exclusively via an Ethernet connection.<br>
|
||||
The module has been successfully used so far with Pylontech batteries of the following types: <br>
|
||||
|
||||
<ul>
|
||||
<ul>
|
||||
<li> US2000 </li>
|
||||
<li> US2000B Plus </li>
|
||||
<li> US2000C </li>
|
||||
<li> US2000 Plus </li>
|
||||
<li> US3000 </li>
|
||||
<li> US3000C </li>
|
||||
</ul>
|
||||
</ul>
|
||||
|
||||
The following devices have been successfully used as RS485 Ethernet gateways to date: <br>
|
||||
<ul>
|
||||
The following devices have been successfully used as RS485 Ethernet gateways to date: <br>
|
||||
<ul>
|
||||
<li> USR-TCP232-304 from the manufacturer USRiot </li>
|
||||
<li> Waveshare RS485 to Ethernet Converter </li>
|
||||
</ul>
|
||||
</ul>
|
||||
|
||||
In principle, any other RS485/Ethernet gateway should also be compatible.
|
||||
<br><br>
|
||||
In principle, any other RS485/Ethernet gateway should also be compatible.
|
||||
<br><br>
|
||||
|
||||
<b>Requirements</b>
|
||||
<br><br>
|
||||
This module requires the Perl modules:
|
||||
<ul>
|
||||
<b>Requirements</b>
|
||||
<br><br>
|
||||
This module requires the Perl modules:
|
||||
<ul>
|
||||
<li>IO::Socket::INET (apt-get install libio-socket-multicast-perl) </li>
|
||||
<li>IO::Socket::Timeout (Installation e.g. via the CPAN shell or the FHEM Installer module) </li>
|
||||
</ul>
|
||||
</ul>
|
||||
|
||||
The data format must be set on the RS485 gateway as follows:
|
||||
<br>
|
||||
The data format must be set on the RS485 gateway as follows:
|
||||
<br>
|
||||
|
||||
<ul>
|
||||
<table>
|
||||
@ -1550,14 +1560,46 @@ The data format must be set on the RS485 gateway as follows:
|
||||
</ul>
|
||||
<br>
|
||||
|
||||
<b>Limitations</b>
|
||||
<br>
|
||||
The module currently supports a maximum of 14 batteries (master + 13 slaves) in one group.
|
||||
<br><br>
|
||||
<b>Example configuration of a Waveshare RS485 to Ethernet converter</b>
|
||||
<br><br>
|
||||
The converter's web interface offers several pages with settings. The relevant settings are shown below
|
||||
as an example. The assignment of a fixed IP address is assumed in advance.
|
||||
<br>
|
||||
|
||||
<a id="PylonLowVoltage-define"></a>
|
||||
<b>Definition</b>
|
||||
<ul>
|
||||
<ul>
|
||||
<table>
|
||||
<colgroup> <col width="25%"> <col width="75%"> </colgroup>
|
||||
<tr><td> <b>Serial port settings</b> </td><td> </td></tr>
|
||||
<tr><td> - Baud Rate </td><td>: according to the battery setting </td></tr>
|
||||
<tr><td> - Data Size </td><td>: 8 Bit </td></tr>
|
||||
<tr><td> - Parity </td><td>: None </td></tr>
|
||||
<tr><td> - Stop Bits </td><td>: 1 </td></tr>
|
||||
<tr><td> - Local Port Number </td><td>: freely selected </td></tr>
|
||||
<tr><td> - Work Mode </td><td>: TCP Server </td></tr>
|
||||
<tr><td> - Reset </td><td>: not set </td></tr>
|
||||
<tr><td> - Link </td><td>: set </td></tr>
|
||||
<tr><td> - Index </td><td>: not set </td></tr>
|
||||
<tr><td> - Similar RCF2217 </td><td>: set </td></tr>
|
||||
<tr><td> </td><td> </td></tr>
|
||||
<tr><td> <b>Settings Expand Function</b> </td><td> </td></tr>
|
||||
<tr><td> - Heartbeat Packet Type </td><td>: None </td></tr>
|
||||
<tr><td> - Register Packet Type </td><td>: None </td></tr>
|
||||
<tr><td> - Short Connection </td><td>: not set </td></tr>
|
||||
<tr><td> - TCP Server-kick off old connection </td><td>: set </td></tr>
|
||||
<tr><td> - Buffer Data before Connected </td><td>: set </td></tr>
|
||||
<tr><td> - UART Set Parameter </td><td>: not set </td></tr>
|
||||
</table>
|
||||
</ul>
|
||||
<br>
|
||||
|
||||
<b>Limitations</b>
|
||||
<br>
|
||||
The module currently supports a maximum of 14 batteries (master + 13 slaves) in one group.
|
||||
<br><br>
|
||||
|
||||
<a id="PylonLowVoltage-define"></a>
|
||||
<b>Definition</b>
|
||||
<ul>
|
||||
<code><b>define <name> PylonLowVoltage <hostname/ip>:<port> [<bataddress>]</b></code><br>
|
||||
<br>
|
||||
<li><b>hostname/ip:</b><br>
|
||||
@ -1572,34 +1614,34 @@ The module currently supports a maximum of 14 batteries (master + 13 slaves) in
|
||||
Device address of the Pylontech battery. Several Pylontech batteries can be connected via a Pylontech-specific
|
||||
Link connection. The permissible number can be found in the respective Pylontech documentation. <br>
|
||||
The master battery in the network (with open link port 0 or to which the RS485 connection is connected) has the
|
||||
address 2, the next battery then has address 3 and so on.
|
||||
address 1, the next battery then has address 2 and so on.
|
||||
If no device address is specified, address 1 is used.
|
||||
</li>
|
||||
<br>
|
||||
</ul>
|
||||
</ul>
|
||||
|
||||
<b>Mode of operation</b>
|
||||
<ul>
|
||||
Depending on the setting of the "Interval" attribute, the module cyclically reads values provided by the battery
|
||||
management system via the RS485 interface.
|
||||
</ul>
|
||||
<b>Mode of operation</b>
|
||||
<ul>
|
||||
Depending on the setting of the "Interval" attribute, the module cyclically reads values provided by the battery
|
||||
management system via the RS485 interface.
|
||||
</ul>
|
||||
|
||||
<a id="PylonLowVoltage-get"></a>
|
||||
<b>Get</b>
|
||||
<br>
|
||||
<ul>
|
||||
<a id="PylonLowVoltage-get"></a>
|
||||
<b>Get</b>
|
||||
<br>
|
||||
<ul>
|
||||
<li><b>data</b><br>
|
||||
The data query of the battery management system is executed. The timer of the cyclic query is reinitialized according
|
||||
to the set value of the "interval" attribute.
|
||||
<br>
|
||||
</li>
|
||||
<br>
|
||||
</ul>
|
||||
<br>
|
||||
</ul>
|
||||
|
||||
<a id="PylonLowVoltage-attr"></a>
|
||||
<b>Attributes</b>
|
||||
<br<br>
|
||||
<ul>
|
||||
<a id="PylonLowVoltage-attr"></a>
|
||||
<b>Attributes</b>
|
||||
<br<br>
|
||||
<ul>
|
||||
<a id="PylonLowVoltage-attr-disable"></a>
|
||||
<li><b>disable 0|1</b><br>
|
||||
Enables/disables the device definition.
|
||||
@ -1630,105 +1672,105 @@ management system via the RS485 interface.
|
||||
The automatically determined battery type (Reading batteryType) is replaced by the specified string.
|
||||
</li>
|
||||
<br>
|
||||
</ul>
|
||||
</ul>
|
||||
|
||||
<a id="PylonLowVoltage-readings"></a>
|
||||
<b>Readings</b>
|
||||
<ul>
|
||||
<li><b>averageCellVolt</b><br> Average cell voltage (V) </li>
|
||||
<li><b>bmsTemperature</b><br> Temperature (°C) of the battery management system </li>
|
||||
<li><b>cellTemperature_0104</b><br> Temperature (°C) of cell packs 1 to 4 </li>
|
||||
<li><b>cellTemperature_0508</b><br> Temperature (°C) of cell packs 5 to 8 </li>
|
||||
<li><b>cellTemperature_0912</b><br> Temperature (°C) of the cell packs 9 to 12 </li>
|
||||
<li><b>cellTemperature_1315</b><br> Temperature (°C) of the cell packs 13 to 15 </li>
|
||||
<li><b>cellVoltage_XX</b><br> Cell voltage (V) of the cell pack XX. In the battery module "packCellcount"
|
||||
<a id="PylonLowVoltage-readings"></a>
|
||||
<b>Readings</b>
|
||||
<ul>
|
||||
<li><b>averageCellVolt</b><br> Average cell voltage (V) </li>
|
||||
<li><b>bmsTemperature</b><br> Temperature (°C) of the battery management system </li>
|
||||
<li><b>cellTemperature_0104</b><br> Temperature (°C) of cell packs 1 to 4 </li>
|
||||
<li><b>cellTemperature_0508</b><br> Temperature (°C) of cell packs 5 to 8 </li>
|
||||
<li><b>cellTemperature_0912</b><br> Temperature (°C) of the cell packs 9 to 12 </li>
|
||||
<li><b>cellTemperature_1315</b><br> Temperature (°C) of the cell packs 13 to 15 </li>
|
||||
<li><b>cellVoltage_XX</b><br> Cell voltage (V) of the cell pack XX. In the battery module "packCellcount"
|
||||
cell packs are connected in series. Each cell pack consists of single cells
|
||||
connected in parallel. </li>
|
||||
<li><b>chargeCurrentLimit</b><br> current limit value for the charging current (A) </li>
|
||||
<li><b>chargeEnable</b><br> current flag loading allowed </li>
|
||||
<li><b>chargeFullRequest</b><br> current flag charge battery module fully (from the mains if necessary) </li>
|
||||
<li><b>chargeImmediatelySOCXX</b><br> current flag charge battery module immediately
|
||||
<li><b>chargeCurrentLimit</b><br> current limit value for the charging current (A) </li>
|
||||
<li><b>chargeEnable</b><br> current flag loading allowed </li>
|
||||
<li><b>chargeFullRequest</b><br> current flag charge battery module fully (from the mains if necessary) </li>
|
||||
<li><b>chargeImmediatelySOCXX</b><br> current flag charge battery module immediately
|
||||
(05: SOC limit 5-9%, 09: SOC limit 9-13%) </li>
|
||||
<li><b>chargeVoltageLimit</b><br> current charge voltage limit (V) of the battery module </li>
|
||||
<li><b>dischargeCurrentLimit</b><br> current limit value for the discharge current (A) </li>
|
||||
<li><b>dischargeEnable</b><br> current flag unloading allowed </li>
|
||||
<li><b>dischargeVoltageLimit</b><br> current discharge voltage limit (V) of the battery module </li>
|
||||
<li><b>chargeVoltageLimit</b><br> current charge voltage limit (V) of the battery module </li>
|
||||
<li><b>dischargeCurrentLimit</b><br> current limit value for the discharge current (A) </li>
|
||||
<li><b>dischargeEnable</b><br> current flag unloading allowed </li>
|
||||
<li><b>dischargeVoltageLimit</b><br> current discharge voltage limit (V) of the battery module </li>
|
||||
|
||||
<li><b>moduleSoftwareVersion_manufacture</b><br> Firmware version of the battery module </li>
|
||||
<li><b>moduleSoftwareVersion_manufacture</b><br> Firmware version of the battery module </li>
|
||||
|
||||
<li><b>packAlarmInfo</b><br> Alarm status (ok - battery module is OK, failure - there is a fault in the
|
||||
<li><b>packAlarmInfo</b><br> Alarm status (ok - battery module is OK, failure - there is a fault in the
|
||||
battery module) </li>
|
||||
<li><b>packCapacity</b><br> nominal capacity (Ah) of the battery module </li>
|
||||
<li><b>packCapacityRemain</b><br> current capacity (Ah) of the battery module </li>
|
||||
<li><b>packCellcount</b><br> Number of cell packs in the battery module </li>
|
||||
<li><b>packCurrent</b><br> current charge current (+) or discharge current (-) of the battery module (A) </li>
|
||||
<li><b>packCycles</b><br> Number of full cycles - The number of cycles is, to some extent, a measure of the
|
||||
<li><b>packCapacity</b><br> nominal capacity (Ah) of the battery module </li>
|
||||
<li><b>packCapacityRemain</b><br> current capacity (Ah) of the battery module </li>
|
||||
<li><b>packCellcount</b><br> Number of cell packs in the battery module </li>
|
||||
<li><b>packCurrent</b><br> current charge current (+) or discharge current (-) of the battery module (A) </li>
|
||||
<li><b>packCycles</b><br> Number of full cycles - The number of cycles is, to some extent, a measure of the
|
||||
wear and tear of the battery. A complete charge and discharge is counted as one
|
||||
cycle. If the battery is discharged and recharged 50%, it only counts as one
|
||||
half cycle. Pylontech specifies a lifetime of several 1000 cycles
|
||||
(see data sheet). </li>
|
||||
<li><b>packImbalance</b><br> current imbalance of voltage between the single cells of the
|
||||
<li><b>packImbalance</b><br> current imbalance of voltage between the single cells of the
|
||||
battery module (%) </li>
|
||||
<li><b>packPower</b><br> current drawn (+) or delivered (-) power (W) of the battery module </li>
|
||||
<li><b>packSOC</b><br> State of charge (%) of the battery module </li>
|
||||
<li><b>packState</b><br> current working status of the battery module </li>
|
||||
<li><b>packVolt</b><br> current voltage (V) of the battery module </li>
|
||||
<li><b>packPower</b><br> current drawn (+) or delivered (-) power (W) of the battery module </li>
|
||||
<li><b>packSOC</b><br> State of charge (%) of the battery module </li>
|
||||
<li><b>packState</b><br> current working status of the battery module </li>
|
||||
<li><b>packVolt</b><br> current voltage (V) of the battery module </li>
|
||||
|
||||
<li><b>paramCellHighVoltLimit</b><br> System parameter upper voltage limit (V) of a cell </li>
|
||||
<li><b>paramCellLowVoltLimit</b><br> System parameter lower voltage limit (V) of a cell (alarm limit) </li>
|
||||
<li><b>paramCellUnderVoltLimit</b><br> System parameter undervoltage limit (V) of a cell (protection limit) </li>
|
||||
<li><b>paramChargeCurrentLimit</b><br> System parameter charging current limit (A) of the battery module </li>
|
||||
<li><b>paramChargeHighTempLimit</b><br> System parameter upper temperature limit (°C) up to which the battery charges </li>
|
||||
<li><b>paramChargeLowTempLimit</b><br> System parameter lower temperature limit (°C) up to which the battery charges </li>
|
||||
<li><b>paramDischargeCurrentLimit</b><br> System parameter discharge current limit (A) of the battery module </li>
|
||||
<li><b>paramDischargeHighTempLimit</b><br> System parameter upper temperature limit (°C) up to which the battery discharges </li>
|
||||
<li><b>paramDischargeLowTempLimit</b><br> System parameter lower temperature limit (°C) up to which the battery discharges </li>
|
||||
<li><b>paramModuleHighVoltLimit</b><br> System parameter upper voltage limit (V) of the battery module </li>
|
||||
<li><b>paramModuleLowVoltLimit</b><br> System parameter lower voltage limit (V) of the battery module (alarm limit) </li>
|
||||
<li><b>paramModuleUnderVoltLimit</b><br> System parameter undervoltage limit (V) of the battery module (protection limit) </li>
|
||||
<li><b>protocolVersion</b><br> PYLON low voltage RS485 protocol version </li>
|
||||
<li><b>serialNumber</b><br> Serial number </li>
|
||||
</ul>
|
||||
<br><br>
|
||||
<li><b>paramCellHighVoltLimit</b><br> System parameter upper voltage limit (V) of a cell </li>
|
||||
<li><b>paramCellLowVoltLimit</b><br> System parameter lower voltage limit (V) of a cell (alarm limit) </li>
|
||||
<li><b>paramCellUnderVoltLimit</b><br> System parameter undervoltage limit (V) of a cell (protection limit) </li>
|
||||
<li><b>paramChargeCurrentLimit</b><br> System parameter charging current limit (A) of the battery module </li>
|
||||
<li><b>paramChargeHighTempLimit</b><br> System parameter upper temperature limit (°C) up to which the battery charges </li>
|
||||
<li><b>paramChargeLowTempLimit</b><br> System parameter lower temperature limit (°C) up to which the battery charges </li>
|
||||
<li><b>paramDischargeCurrentLimit</b><br> System parameter discharge current limit (A) of the battery module </li>
|
||||
<li><b>paramDischargeHighTempLimit</b><br> System parameter upper temperature limit (°C) up to which the battery discharges </li>
|
||||
<li><b>paramDischargeLowTempLimit</b><br> System parameter lower temperature limit (°C) up to which the battery discharges </li>
|
||||
<li><b>paramModuleHighVoltLimit</b><br> System parameter upper voltage limit (V) of the battery module </li>
|
||||
<li><b>paramModuleLowVoltLimit</b><br> System parameter lower voltage limit (V) of the battery module (alarm limit) </li>
|
||||
<li><b>paramModuleUnderVoltLimit</b><br> System parameter undervoltage limit (V) of the battery module (protection limit) </li>
|
||||
<li><b>protocolVersion</b><br> PYLON low voltage RS485 protocol version </li>
|
||||
<li><b>serialNumber</b><br> Serial number </li>
|
||||
</ul>
|
||||
<br><br>
|
||||
|
||||
=end html
|
||||
=begin html_DE
|
||||
|
||||
<a id="PylonLowVoltage"></a>
|
||||
<h3>PylonLowVoltage</h3>
|
||||
<br>
|
||||
Modul zur Einbindung von Niedervolt-Batterien mit Batteriemanagmentsystem (BMS) des Herstellers Pylontech über RS485 via
|
||||
RS485/Ethernet-Gateway. Die Kommunikation zum RS485-Gateway erfolgt ausschließlich über eine Ethernet-Verbindung.<br>
|
||||
Das Modul wurde bisher erfolgreich mit Pylontech Batterien folgender Typen eingesetzt: <br>
|
||||
<a id="PylonLowVoltage"></a>
|
||||
<h3>PylonLowVoltage</h3>
|
||||
<br>
|
||||
Modul zur Einbindung von Niedervolt-Batterien mit Batteriemanagmentsystem (BMS) des Herstellers Pylontech über RS485 via
|
||||
RS485/Ethernet-Gateway. Die Kommunikation zum RS485-Gateway erfolgt ausschließlich über eine Ethernet-Verbindung.<br>
|
||||
Das Modul wurde bisher erfolgreich mit Pylontech Batterien folgender Typen eingesetzt: <br>
|
||||
|
||||
<ul>
|
||||
<ul>
|
||||
<li> US2000 </li>
|
||||
<li> US2000B Plus </li>
|
||||
<li> US2000C </li>
|
||||
<li> US2000 Plus </li>
|
||||
<li> US3000 </li>
|
||||
<li> US3000C </li>
|
||||
</ul>
|
||||
</ul>
|
||||
|
||||
Als RS485-Ethernet-Gateways wurden bisher folgende Geräte erfolgreich eingesetzt: <br>
|
||||
<ul>
|
||||
Als RS485-Ethernet-Gateways wurden bisher folgende Geräte erfolgreich eingesetzt: <br>
|
||||
<ul>
|
||||
<li> USR-TCP232-304 des Herstellers USRiot </li>
|
||||
<li> Waveshare RS485 to Ethernet Converter </li>
|
||||
</ul>
|
||||
</ul>
|
||||
|
||||
Prinzipiell sollte auch jedes andere RS485/Ethernet-Gateway kompatibel sein.
|
||||
<br><br>
|
||||
Prinzipiell sollte auch jedes andere RS485/Ethernet-Gateway kompatibel sein.
|
||||
<br><br>
|
||||
|
||||
<b>Voraussetzungen</b>
|
||||
<br><br>
|
||||
Dieses Modul benötigt die Perl-Module:
|
||||
<ul>
|
||||
<b>Voraussetzungen</b>
|
||||
<br><br>
|
||||
Dieses Modul benötigt die Perl-Module:
|
||||
<ul>
|
||||
<li>IO::Socket::INET (apt-get install libio-socket-multicast-perl) </li>
|
||||
<li>IO::Socket::Timeout (Installation z.B. über die CPAN-Shell oder das FHEM Installer Modul) </li>
|
||||
</ul>
|
||||
</ul>
|
||||
|
||||
Das Datenformat muß auf dem RS485 Gateway wie folgt eingestellt werden:
|
||||
<br>
|
||||
Das Datenformat muß auf dem RS485 Gateway wie folgt eingestellt werden:
|
||||
<br>
|
||||
|
||||
<ul>
|
||||
<table>
|
||||
@ -1741,14 +1783,46 @@ Das Datenformat muß auf dem RS485 Gateway wie folgt eingestellt werden:
|
||||
</ul>
|
||||
<br>
|
||||
|
||||
<b>Einschränkungen</b>
|
||||
<br>
|
||||
Das Modul unterstützt zur Zeit maximal 14 Batterien (Master + 13 Slaves) in einer Gruppe.
|
||||
<br><br>
|
||||
<b>Beispielkonfiguration eines Waveshare RS485 to Ethernet Converters</b>
|
||||
<br><br>
|
||||
Das Webinterface des Konverters bietet mehrere Seiten mit Einstellungen an. Die relevanten Einstellungen sind nachfolgend
|
||||
beispielhaft gezeigt. Die Zuweisung einer festen IP-Adresse wird vorab vorausgesetzt.
|
||||
<br>
|
||||
|
||||
<a id="PylonLowVoltage-define"></a>
|
||||
<b>Definition</b>
|
||||
<ul>
|
||||
<ul>
|
||||
<table>
|
||||
<colgroup> <col width="25%"> <col width="75%"> </colgroup>
|
||||
<tr><td> <b>Einstellungen Serial Port</b> </td><td> </td></tr>
|
||||
<tr><td> - Baud Rate </td><td>: entsprechend Einstellung der Batterie </td></tr>
|
||||
<tr><td> - Data Size </td><td>: 8 Bit </td></tr>
|
||||
<tr><td> - Parity </td><td>: None </td></tr>
|
||||
<tr><td> - Stop Bits </td><td>: 1 </td></tr>
|
||||
<tr><td> - Local Port Number </td><td>: frei gewählt </td></tr>
|
||||
<tr><td> - Work Mode </td><td>: TCP Server </td></tr>
|
||||
<tr><td> - Reset </td><td>: nicht gesetzt </td></tr>
|
||||
<tr><td> - Link </td><td>: gesetzt </td></tr>
|
||||
<tr><td> - Index </td><td>: nicht gesetzt </td></tr>
|
||||
<tr><td> - Similar RCF2217 </td><td>: gesetzt </td></tr>
|
||||
<tr><td> </td><td> </td></tr>
|
||||
<tr><td> <b>Einstellungen Expand Function</b> </td><td> </td></tr>
|
||||
<tr><td> - Heartbeat Packet Type </td><td>: None </td></tr>
|
||||
<tr><td> - Register Packet Type </td><td>: None </td></tr>
|
||||
<tr><td> - Short Connection </td><td>: nicht gesetzt </td></tr>
|
||||
<tr><td> - TCP Server-kick off old connection </td><td>: gesetzt </td></tr>
|
||||
<tr><td> - Buffer Data before Connected </td><td>: gesetzt </td></tr>
|
||||
<tr><td> - UART Set Parameter </td><td>: nicht gesetzt </td></tr>
|
||||
</table>
|
||||
</ul>
|
||||
<br>
|
||||
|
||||
<b>Einschränkungen</b>
|
||||
<br>
|
||||
Das Modul unterstützt zur Zeit maximal 14 Batterien (Master + 13 Slaves) in einer Gruppe.
|
||||
<br><br>
|
||||
|
||||
<a id="PylonLowVoltage-define"></a>
|
||||
<b>Definition</b>
|
||||
<ul>
|
||||
<code><b>define <name> PylonLowVoltage <hostname/ip>:<port> [<bataddress>]</b></code><br>
|
||||
<br>
|
||||
<li><b>hostname/ip:</b><br>
|
||||
@ -1763,34 +1837,34 @@ Das Modul unterstützt zur Zeit maximal 14 Batterien (Master + 13 Slaves) in ein
|
||||
Geräteadresse der Pylontech Batterie. Es können mehrere Pylontech Batterien über eine Pylontech-spezifische
|
||||
Link-Verbindung verbunden werden. Die zulässige Anzahl ist der jeweiligen Pylontech Dokumentation zu entnehmen. <br>
|
||||
Die Master Batterie im Verbund (mit offenem Link Port 0 bzw. an der die RS485-Verbindung angeschlossen ist) hat die
|
||||
Adresse 2, die nächste Batterie hat dann die Adresse 3 und so weiter.
|
||||
Adresse 1, die nächste Batterie hat dann die Adresse 2 und so weiter.
|
||||
Ist keine Geräteadresse angegeben, wird die Adresse 1 verwendet.
|
||||
</li>
|
||||
<br>
|
||||
</ul>
|
||||
</ul>
|
||||
|
||||
<b>Arbeitsweise</b>
|
||||
<ul>
|
||||
Das Modul liest entsprechend der Einstellung des Attributes "interval" zyklisch Werte aus, die das
|
||||
Batteriemanagementsystem über die RS485-Schnittstelle zur Verfügung stellt.
|
||||
</ul>
|
||||
<b>Arbeitsweise</b>
|
||||
<ul>
|
||||
Das Modul liest entsprechend der Einstellung des Attributes "interval" zyklisch Werte aus, die das
|
||||
Batteriemanagementsystem über die RS485-Schnittstelle zur Verfügung stellt.
|
||||
</ul>
|
||||
|
||||
<a id="PylonLowVoltage-get"></a>
|
||||
<b>Get</b>
|
||||
<br>
|
||||
<ul>
|
||||
<a id="PylonLowVoltage-get"></a>
|
||||
<b>Get</b>
|
||||
<br>
|
||||
<ul>
|
||||
<li><b>data</b><br>
|
||||
Die Datenabfrage des Batteriemanagementsystems wird ausgeführt. Der Zeitgeber der zyklischen Abfrage wird entsprechend
|
||||
dem gesetzten Wert des Attributes "interval" neu initialisiert.
|
||||
<br>
|
||||
</li>
|
||||
<br>
|
||||
</ul>
|
||||
<br>
|
||||
</ul>
|
||||
|
||||
<a id="PylonLowVoltage-attr"></a>
|
||||
<b>Attribute</b>
|
||||
<br<br>
|
||||
<ul>
|
||||
<a id="PylonLowVoltage-attr"></a>
|
||||
<b>Attribute</b>
|
||||
<br<br>
|
||||
<ul>
|
||||
<a id="PylonLowVoltage-attr-disable"></a>
|
||||
<li><b>disable 0|1</b><br>
|
||||
Aktiviert/deaktiviert die Gerätedefinition.
|
||||
@ -1822,66 +1896,66 @@ Batteriemanagementsystem über die RS485-Schnittstelle zur Verfügung stellt.
|
||||
Der automatisch ermittelte Batterietyp (Reading batteryType) wird durch die angegebene Zeichenfolge ersetzt.
|
||||
</li>
|
||||
<br>
|
||||
</ul>
|
||||
</ul>
|
||||
|
||||
<a id="PylonLowVoltage-readings"></a>
|
||||
<b>Readings</b>
|
||||
<ul>
|
||||
<li><b>averageCellVolt</b><br> mittlere Zellenspannung (V) </li>
|
||||
<li><b>bmsTemperature</b><br> Temperatur (°C) des Batteriemanagementsystems </li>
|
||||
<li><b>cellTemperature_0104</b><br> Temperatur (°C) der Zellenpacks 1 bis 4 </li>
|
||||
<li><b>cellTemperature_0508</b><br> Temperatur (°C) der Zellenpacks 5 bis 8 </li>
|
||||
<li><b>cellTemperature_0912</b><br> Temperatur (°C) der Zellenpacks 9 bis 12 </li>
|
||||
<li><b>cellTemperature_1315</b><br> Temperatur (°C) der Zellenpacks 13 bis 15 </li>
|
||||
<li><b>cellVoltage_XX</b><br> Zellenspannung (V) des Zellenpacks XX. In dem Batteriemodul sind "packCellcount"
|
||||
<a id="PylonLowVoltage-readings"></a>
|
||||
<b>Readings</b>
|
||||
<ul>
|
||||
<li><b>averageCellVolt</b><br> mittlere Zellenspannung (V) </li>
|
||||
<li><b>bmsTemperature</b><br> Temperatur (°C) des Batteriemanagementsystems </li>
|
||||
<li><b>cellTemperature_0104</b><br> Temperatur (°C) der Zellenpacks 1 bis 4 </li>
|
||||
<li><b>cellTemperature_0508</b><br> Temperatur (°C) der Zellenpacks 5 bis 8 </li>
|
||||
<li><b>cellTemperature_0912</b><br> Temperatur (°C) der Zellenpacks 9 bis 12 </li>
|
||||
<li><b>cellTemperature_1315</b><br> Temperatur (°C) der Zellenpacks 13 bis 15 </li>
|
||||
<li><b>cellVoltage_XX</b><br> Zellenspannung (V) des Zellenpacks XX. In dem Batteriemodul sind "packCellcount"
|
||||
Zellenpacks in Serie geschaltet verbaut. Jedes Zellenpack besteht aus parallel
|
||||
geschalten Einzelzellen. </li>
|
||||
<li><b>chargeCurrentLimit</b><br> aktueller Grenzwert für den Ladestrom (A) </li>
|
||||
<li><b>chargeEnable</b><br> aktuelles Flag Laden erlaubt </li>
|
||||
<li><b>chargeFullRequest</b><br> aktuelles Flag Batteriemodul voll laden (notfalls aus dem Netz) </li>
|
||||
<li><b>chargeImmediatelySOCXX</b><br> aktuelles Flag Batteriemodul sofort laden
|
||||
<li><b>chargeCurrentLimit</b><br> aktueller Grenzwert für den Ladestrom (A) </li>
|
||||
<li><b>chargeEnable</b><br> aktuelles Flag Laden erlaubt </li>
|
||||
<li><b>chargeFullRequest</b><br> aktuelles Flag Batteriemodul voll laden (notfalls aus dem Netz) </li>
|
||||
<li><b>chargeImmediatelySOCXX</b><br> aktuelles Flag Batteriemodul sofort laden
|
||||
(05: SOC Grenze 5-9%, 09: SOC Grenze 9-13%) </li>
|
||||
<li><b>chargeVoltageLimit</b><br> aktuelle Ladespannungsgrenze (V) des Batteriemoduls </li>
|
||||
<li><b>dischargeCurrentLimit</b><br> aktueller Grenzwert für den Entladestrom (A) </li>
|
||||
<li><b>dischargeEnable</b><br> aktuelles Flag Entladen erlaubt </li>
|
||||
<li><b>dischargeVoltageLimit</b><br> aktuelle Entladespannungsgrenze (V) des Batteriemoduls </li>
|
||||
<li><b>chargeVoltageLimit</b><br> aktuelle Ladespannungsgrenze (V) des Batteriemoduls </li>
|
||||
<li><b>dischargeCurrentLimit</b><br> aktueller Grenzwert für den Entladestrom (A) </li>
|
||||
<li><b>dischargeEnable</b><br> aktuelles Flag Entladen erlaubt </li>
|
||||
<li><b>dischargeVoltageLimit</b><br> aktuelle Entladespannungsgrenze (V) des Batteriemoduls </li>
|
||||
|
||||
<li><b>moduleSoftwareVersion_manufacture</b><br> Firmware Version des Batteriemoduls </li>
|
||||
<li><b>moduleSoftwareVersion_manufacture</b><br> Firmware Version des Batteriemoduls </li>
|
||||
|
||||
<li><b>packAlarmInfo</b><br> Alarmstatus (ok - Batterienmodul ist in Ordnung, failure - im Batteriemodul liegt
|
||||
<li><b>packAlarmInfo</b><br> Alarmstatus (ok - Batterienmodul ist in Ordnung, failure - im Batteriemodul liegt
|
||||
eine Störung vor) </li>
|
||||
<li><b>packCapacity</b><br> nominale Kapazität (Ah) des Batteriemoduls </li>
|
||||
<li><b>packCapacityRemain</b><br> aktuelle Kapazität (Ah) des Batteriemoduls </li>
|
||||
<li><b>packCellcount</b><br> Anzahl der Zellenpacks im Batteriemodul </li>
|
||||
<li><b>packCurrent</b><br> aktueller Ladestrom (+) bzw. Entladstrom (-) des Batteriemoduls (A) </li>
|
||||
<li><b>packCycles</b><br> Anzahl der Vollzyklen - Die Anzahl der Zyklen ist in gewisserweise ein Maß für den
|
||||
<li><b>packCapacity</b><br> nominale Kapazität (Ah) des Batteriemoduls </li>
|
||||
<li><b>packCapacityRemain</b><br> aktuelle Kapazität (Ah) des Batteriemoduls </li>
|
||||
<li><b>packCellcount</b><br> Anzahl der Zellenpacks im Batteriemodul </li>
|
||||
<li><b>packCurrent</b><br> aktueller Ladestrom (+) bzw. Entladstrom (-) des Batteriemoduls (A) </li>
|
||||
<li><b>packCycles</b><br> Anzahl der Vollzyklen - Die Anzahl der Zyklen ist in gewisserweise ein Maß für den
|
||||
Verschleiß der Batterie. Eine komplettes Laden und Entladen wird als ein Zyklus
|
||||
gewertet. Wird die Batterie 50% entladen und wieder aufgeladen, zählt das nur als ein
|
||||
halber Zyklus. Pylontech gibt eine Lebensdauer von mehreren 1000 Zyklen an
|
||||
(siehe Datenblatt). </li>
|
||||
<li><b>packImbalance</b><br> aktuelles Ungleichgewicht der Spannung zwischen den Einzelzellen des
|
||||
<li><b>packImbalance</b><br> aktuelles Ungleichgewicht der Spannung zwischen den Einzelzellen des
|
||||
Batteriemoduls (%) </li>
|
||||
<li><b>packPower</b><br> aktuell bezogene (+) bzw. gelieferte (-) Leistung (W) des Batteriemoduls </li>
|
||||
<li><b>packSOC</b><br> Ladezustand (%) des Batteriemoduls </li>
|
||||
<li><b>packState</b><br> aktueller Arbeitsstatus des Batteriemoduls </li>
|
||||
<li><b>packVolt</b><br> aktuelle Spannung (V) des Batteriemoduls </li>
|
||||
<li><b>packPower</b><br> aktuell bezogene (+) bzw. gelieferte (-) Leistung (W) des Batteriemoduls </li>
|
||||
<li><b>packSOC</b><br> Ladezustand (%) des Batteriemoduls </li>
|
||||
<li><b>packState</b><br> aktueller Arbeitsstatus des Batteriemoduls </li>
|
||||
<li><b>packVolt</b><br> aktuelle Spannung (V) des Batteriemoduls </li>
|
||||
|
||||
<li><b>paramCellHighVoltLimit</b><br> Systemparameter obere Spannungsgrenze (V) einer Zelle </li>
|
||||
<li><b>paramCellLowVoltLimit</b><br> Systemparameter untere Spannungsgrenze (V) einer Zelle (Alarmgrenze) </li>
|
||||
<li><b>paramCellUnderVoltLimit</b><br> Systemparameter Unterspannungsgrenze (V) einer Zelle (Schutzgrenze) </li>
|
||||
<li><b>paramChargeCurrentLimit</b><br> Systemparameter Ladestromgrenze (A) des Batteriemoduls </li>
|
||||
<li><b>paramChargeHighTempLimit</b><br> Systemparameter obere Temperaturgrenze (°C) bis zu der die Batterie lädt </li>
|
||||
<li><b>paramChargeLowTempLimit</b><br> Systemparameter untere Temperaturgrenze (°C) bis zu der die Batterie lädt </li>
|
||||
<li><b>paramDischargeCurrentLimit</b><br> Systemparameter Entladestromgrenze (A) des Batteriemoduls </li>
|
||||
<li><b>paramDischargeHighTempLimit</b><br> Systemparameter obere Temperaturgrenze (°C) bis zu der die Batterie entlädt </li>
|
||||
<li><b>paramDischargeLowTempLimit</b><br> Systemparameter untere Temperaturgrenze (°C) bis zu der die Batterie entlädt </li>
|
||||
<li><b>paramModuleHighVoltLimit</b><br> Systemparameter obere Spannungsgrenze (V) des Batteriemoduls </li>
|
||||
<li><b>paramModuleLowVoltLimit</b><br> Systemparameter untere Spannungsgrenze (V) des Batteriemoduls (Alarmgrenze) </li>
|
||||
<li><b>paramModuleUnderVoltLimit</b><br> Systemparameter Unterspannungsgrenze (V) des Batteriemoduls (Schutzgrenze) </li>
|
||||
<li><b>protocolVersion</b><br> PYLON low voltage RS485 Prokollversion </li>
|
||||
<li><b>serialNumber</b><br> Seriennummer </li>
|
||||
</ul>
|
||||
<br><br>
|
||||
<li><b>paramCellHighVoltLimit</b><br> Systemparameter obere Spannungsgrenze (V) einer Zelle </li>
|
||||
<li><b>paramCellLowVoltLimit</b><br> Systemparameter untere Spannungsgrenze (V) einer Zelle (Alarmgrenze) </li>
|
||||
<li><b>paramCellUnderVoltLimit</b><br> Systemparameter Unterspannungsgrenze (V) einer Zelle (Schutzgrenze) </li>
|
||||
<li><b>paramChargeCurrentLimit</b><br> Systemparameter Ladestromgrenze (A) des Batteriemoduls </li>
|
||||
<li><b>paramChargeHighTempLimit</b><br> Systemparameter obere Temperaturgrenze (°C) bis zu der die Batterie lädt </li>
|
||||
<li><b>paramChargeLowTempLimit</b><br> Systemparameter untere Temperaturgrenze (°C) bis zu der die Batterie lädt </li>
|
||||
<li><b>paramDischargeCurrentLimit</b><br> Systemparameter Entladestromgrenze (A) des Batteriemoduls </li>
|
||||
<li><b>paramDischargeHighTempLimit</b><br> Systemparameter obere Temperaturgrenze (°C) bis zu der die Batterie entlädt </li>
|
||||
<li><b>paramDischargeLowTempLimit</b><br> Systemparameter untere Temperaturgrenze (°C) bis zu der die Batterie entlädt </li>
|
||||
<li><b>paramModuleHighVoltLimit</b><br> Systemparameter obere Spannungsgrenze (V) des Batteriemoduls </li>
|
||||
<li><b>paramModuleLowVoltLimit</b><br> Systemparameter untere Spannungsgrenze (V) des Batteriemoduls (Alarmgrenze) </li>
|
||||
<li><b>paramModuleUnderVoltLimit</b><br> Systemparameter Unterspannungsgrenze (V) des Batteriemoduls (Schutzgrenze) </li>
|
||||
<li><b>protocolVersion</b><br> PYLON low voltage RS485 Prokollversion </li>
|
||||
<li><b>serialNumber</b><br> Seriennummer </li>
|
||||