diff --git a/fhem/FHEM/10_KNX.pm b/fhem/FHEM/10_KNX.pm index 859f09b09..32c4ec549 100644 --- a/fhem/FHEM/10_KNX.pm +++ b/fhem/FHEM/10_KNX.pm @@ -34,6 +34,7 @@ # ABU 20170503 changed regex for all dpt9 # ABU 20170507 changed regex for all dpt9 # ABU 20170517 added useSetExtensions +# ABU 20170622 finetuned doku package main; @@ -1637,14 +1638,15 @@ sub KNX_getCmdList ($$$) define lamp1 KNX 0A0C:dpt1.003 myTul - One hint regarding dpt1 (binary): all the sub-types have to be used with keyword value. Received telegrams are already encoded to their representation. - Having the on/off button (for send values) without keyword value is an absolutely special use-case and only valid for dpt1 (not the subs).
+ One hint regarding dpt1 (binary): all the sub-types have to be used with keyword value. Received telegrams are already encoded to their representation. This mechanism does not work for send-telegrams. + Here on/off has to be supplied.
+ Having the on/off button (for send values) without keyword value is an absolutely special use-case and only valid for dpt1 and its sub-types.

Example:

       define rollo KNX 0/10/12:dpt1.008
-	  set rollo value up
-	  set rollo value down
+	  set rollo value off
+	  set rollo value on
       
@@ -1905,13 +1907,14 @@ sub KNX_getCmdList ($$$) Ein Hinweis bezüglich dem binären Datentyp dpt1: alle Untertypen müssen über das Schlüsselwort value gesetzt werden. Empfangene Telegramme werden entsprechend ihrer Definition automatisch - umbenannt. Die zur Verfügung stehenden on/off Schaltflächen ohne den Schlüssel value sind ein absoluter Sonderfall und gelten nur für den dpt1 selbst (nicht die Untertypen). + umbenannt. Zu sendende Telegramme sind immer min on/off zu belegen!
+ Die zur Verfügung stehenden on/off Schaltflächen ohne den Schlüssel value sind ein absoluter Sonderfall und gelten für den dpt1 und alle Untertypen.

Example:

       define rollo KNX 0/10/12:dpt1.008
-	  set rollo value up
-	  set rollo value down
+	  set rollo value off
+	  set rollo value on