10_ZWave.pm: small documentation fixes (Forum #53389)

git-svn-id: https://svn.fhem.de/fhem/trunk@11795 2b470e98-0d58-463d-a4d8-8e2adae1ed80
This commit is contained in:
rudolfkoenig 2016-07-15 14:26:37 +00:00
parent 76fbb433fa
commit cf10091631

View File

@ -4610,17 +4610,17 @@ s2Hex($)
<li>sucRouteDel<br>
Delete static return routes to SUC/SIS node.</li>
<br><br><b>Class ALARM (NOTIFICATION), V4</b>
<br><br><b>Class ALARM</b>
<li>alarmnotification &lt;alarmType&gt; (on|off)<br>
Enable (on) or disable (off) the sending of unsolicited reports for
the alarm type &lt;alarmType&gt;. A list of supported alarm types of the
device can be obtained with the "alarmTypeSupported" command. The
device can be obtained with the alarmTypeSupported command. The
name of the alarm type is case insensitive. Sending of an unsolicted
notification only work to associated nodes, broadcasting is not
notification only works to associated nodes, broadcasting is not
allowed, so associations have to be set up. This command is
specified in version 2.</li>
<li> Note:<br>
The name of the class ALARM was renamend to NOTIFICATION in
The name of the class ALARM was renamed to NOTIFICATION in
version 3 of the Zwave specification. Due to backward compatibility
reasons the class will be always referenced as ALARM in FHEM,
regardless of the version.</li>
@ -4815,13 +4815,6 @@ s2Hex($)
<li>location LOCATION<br>
Store LOCATION in the EEPROM. Note: only ASCII is supported.</li>
<br><br><b>Class NOTIFICATION</b>
<li>Note:<br>
The name of the class ALARM was renamend to NOTIFICATION in
version 3 of the Zwave specification. Due to backward compatibility
reasons the class will be always referenced as ALARM in FHEM,
regardless of the version. Please refer to class ALARM.</li>
<br><br><b>Class POWERLEVEL</b>
<li>Class is only used in an installation or test situation</li>
<li>powerlevel level timeout/s<br>
@ -5086,7 +5079,7 @@ s2Hex($)
Since this information is stored in the dongle, the information will be
returned directly even for WAKE_UP devices.</li>
<br><br><b>Class ALARM (NOTIFICATION), V4</b>
<br><br><b>Class ALARM</b>
<li>alarm &lt;alarmId&gt;<br>
return the value for the (decimal) alarmId. The value is device
specific. This command is specified in version 1 and should only
@ -5108,14 +5101,9 @@ s2Hex($)
commands. This command is specified in version 2.</li>
<li>alarmEventSupported &lt;alarmType&gt;<br>
Returns a list of the supported events for the specified alarm type.
The numbers of the events can be used as parameters in the
The number of the events can be used as parameter in the
"alarmWithTypeEvent" command. This command is specified in
version 3.</li>
<li>Note:<br>
The name of the class ALARM was renamend to NOTIFICATION in
version 3 of the Zwave specification. Due to backward compatibility
reasons the class will be always referenced as ALARM in FHEM,
regardless of the version.</li>
<br><br><b>Class ASSOCIATION</b>
<li>association groupId<br>
@ -5280,13 +5268,6 @@ s2Hex($)
<li>location<br>
Get the location from the EEPROM. Note: only ASCII is supported.</li>
<br><br><b>Class NOTIFICATION</b>
<li>Note:<br>
The name of the class ALARM was renamend to NOTIFICATION in
version 3 of the Zwave specification. Due to backward compatibility
reasons the class will be always referenced as ALARM in FHEM,
regardless of the version. Please refer to class ALARM.</li>
<br><br><b>Class POWERLEVEL</b>
<li>powerlevel<br>
Get the current powerlevel and remaining time in this level.</li>
@ -5502,21 +5483,21 @@ s2Hex($)
text after an update. </li>
<li>extendedAlarmReadings<br>
Some devices support more than one alarm type, this attribute
select which type of reading is used for the reports of the ALARM
selects which type of reading is used for the reports of the ALARM
(or NOTIFICATION) class:<br>
A value of "0" select a combined, single reading ("alarm") for
A value of "0" selects a combined, single reading ("alarm") for
all alarm types of the device. Subsequent reports of different
alarm types will overwrite each other. This is the default setting
and the former behavior.<br>
A value of "1" select separate alarm readings for each alarm type
of the device. The readingings are named "alarm_&lt;alarmtype&gt;.
A value of "1" selects separate alarm readings for each alarm type
of the device. The readings are named "alarm_&lt;alarmtype&gt;.
This can also be selected if only one alarmtype is supported by
the device. This reading also contain the status of the
alarmnotification. For compatibility reasons this is currently
the device. This reading also contains the status of the
alarm notification. For compatibility reasons this is currently
not supported with the combined reading.<br>
A value of "2" select both of the above and create a combined and
A value of "2" selects both of the above and creates the combined and
the seperate readings at the same time, this should only be used
if really needed as more or less duplicate events are generated.
if really needed as duplicate events are generated.
</li>
<li><a href="#ignore">ignore</a></li>
@ -5591,16 +5572,16 @@ s2Hex($)
"alarm_&lt;alarmType&gt;.</li>
<li>Devices with class version 1 support: alarm_type_X:level Y</li>
<li>For higher class versions more detailed events with 100+ different
strings in the form alarm:&lt;string&gt;
(or alarm_&lt;alarmType&gt;:&lt;string&gt;) are generated.<br>
For the combined reading, the name of the alarm type is part of
the reading event, for separate readings it is part of the
reading name.<br>
If a cleared event can be identified, the string "Event cleared:"
is reported before the event details.<br>
The seperate readings also contain the status of the
alarmnotification. For compatibility reasons this is currently
not supported with the combined reading. </li>
strings in the form alarm:&lt;string&gt;
(or alarm_&lt;alarmType&gt;:&lt;string&gt;) are generated.<br>
For the combined reading, the name of the alarm type is part of
the reading event, for separate readings it is part of the
reading name.<br>
If a cleared event can be identified, the string "Event cleared:"
is reported before the event details.<br>
The seperate readings also contain the status of the
alarm / notification. For compatibility reasons this is currently
not supported with the combined reading. </li>
<br><b>Class APPLICATION_STATUS</b>
<li>applicationStatus: [cmdRejected]</li>