mirror of
https://github.com/fhem/fhem-mirror.git
synced 2025-02-07 16:59:18 +00:00
10_ZWave.pm: small documentation fixes (Forum #53389)
git-svn-id: https://svn.fhem.de/fhem/trunk@11795 2b470e98-0d58-463d-a4d8-8e2adae1ed80
This commit is contained in:
parent
76fbb433fa
commit
cf10091631
@ -4610,17 +4610,17 @@ s2Hex($)
|
||||
<li>sucRouteDel<br>
|
||||
Delete static return routes to SUC/SIS node.</li>
|
||||
|
||||
<br><br><b>Class ALARM (NOTIFICATION), V4</b>
|
||||
<br><br><b>Class ALARM</b>
|
||||
<li>alarmnotification <alarmType> (on|off)<br>
|
||||
Enable (on) or disable (off) the sending of unsolicited reports for
|
||||
the alarm type <alarmType>. A list of supported alarm types of the
|
||||
device can be obtained with the "alarmTypeSupported" command. The
|
||||
device can be obtained with the alarmTypeSupported command. The
|
||||
name of the alarm type is case insensitive. Sending of an unsolicted
|
||||
notification only work to associated nodes, broadcasting is not
|
||||
notification only works to associated nodes, broadcasting is not
|
||||
allowed, so associations have to be set up. This command is
|
||||
specified in version 2.</li>
|
||||
<li> Note:<br>
|
||||
The name of the class ALARM was renamend to NOTIFICATION in
|
||||
The name of the class ALARM was renamed to NOTIFICATION in
|
||||
version 3 of the Zwave specification. Due to backward compatibility
|
||||
reasons the class will be always referenced as ALARM in FHEM,
|
||||
regardless of the version.</li>
|
||||
@ -4815,13 +4815,6 @@ s2Hex($)
|
||||
<li>location LOCATION<br>
|
||||
Store LOCATION in the EEPROM. Note: only ASCII is supported.</li>
|
||||
|
||||
<br><br><b>Class NOTIFICATION</b>
|
||||
<li>Note:<br>
|
||||
The name of the class ALARM was renamend to NOTIFICATION in
|
||||
version 3 of the Zwave specification. Due to backward compatibility
|
||||
reasons the class will be always referenced as ALARM in FHEM,
|
||||
regardless of the version. Please refer to class ALARM.</li>
|
||||
|
||||
<br><br><b>Class POWERLEVEL</b>
|
||||
<li>Class is only used in an installation or test situation</li>
|
||||
<li>powerlevel level timeout/s<br>
|
||||
@ -5086,7 +5079,7 @@ s2Hex($)
|
||||
Since this information is stored in the dongle, the information will be
|
||||
returned directly even for WAKE_UP devices.</li>
|
||||
|
||||
<br><br><b>Class ALARM (NOTIFICATION), V4</b>
|
||||
<br><br><b>Class ALARM</b>
|
||||
<li>alarm <alarmId><br>
|
||||
return the value for the (decimal) alarmId. The value is device
|
||||
specific. This command is specified in version 1 and should only
|
||||
@ -5108,14 +5101,9 @@ s2Hex($)
|
||||
commands. This command is specified in version 2.</li>
|
||||
<li>alarmEventSupported <alarmType><br>
|
||||
Returns a list of the supported events for the specified alarm type.
|
||||
The numbers of the events can be used as parameters in the
|
||||
The number of the events can be used as parameter in the
|
||||
"alarmWithTypeEvent" command. This command is specified in
|
||||
version 3.</li>
|
||||
<li>Note:<br>
|
||||
The name of the class ALARM was renamend to NOTIFICATION in
|
||||
version 3 of the Zwave specification. Due to backward compatibility
|
||||
reasons the class will be always referenced as ALARM in FHEM,
|
||||
regardless of the version.</li>
|
||||
|
||||
<br><br><b>Class ASSOCIATION</b>
|
||||
<li>association groupId<br>
|
||||
@ -5280,13 +5268,6 @@ s2Hex($)
|
||||
<li>location<br>
|
||||
Get the location from the EEPROM. Note: only ASCII is supported.</li>
|
||||
|
||||
<br><br><b>Class NOTIFICATION</b>
|
||||
<li>Note:<br>
|
||||
The name of the class ALARM was renamend to NOTIFICATION in
|
||||
version 3 of the Zwave specification. Due to backward compatibility
|
||||
reasons the class will be always referenced as ALARM in FHEM,
|
||||
regardless of the version. Please refer to class ALARM.</li>
|
||||
|
||||
<br><br><b>Class POWERLEVEL</b>
|
||||
<li>powerlevel<br>
|
||||
Get the current powerlevel and remaining time in this level.</li>
|
||||
@ -5502,21 +5483,21 @@ s2Hex($)
|
||||
text after an update. </li>
|
||||
<li>extendedAlarmReadings<br>
|
||||
Some devices support more than one alarm type, this attribute
|
||||
select which type of reading is used for the reports of the ALARM
|
||||
selects which type of reading is used for the reports of the ALARM
|
||||
(or NOTIFICATION) class:<br>
|
||||
A value of "0" select a combined, single reading ("alarm") for
|
||||
A value of "0" selects a combined, single reading ("alarm") for
|
||||
all alarm types of the device. Subsequent reports of different
|
||||
alarm types will overwrite each other. This is the default setting
|
||||
and the former behavior.<br>
|
||||
A value of "1" select separate alarm readings for each alarm type
|
||||
of the device. The readingings are named "alarm_<alarmtype>.
|
||||
A value of "1" selects separate alarm readings for each alarm type
|
||||
of the device. The readings are named "alarm_<alarmtype>.
|
||||
This can also be selected if only one alarmtype is supported by
|
||||
the device. This reading also contain the status of the
|
||||
alarmnotification. For compatibility reasons this is currently
|
||||
the device. This reading also contains the status of the
|
||||
alarm notification. For compatibility reasons this is currently
|
||||
not supported with the combined reading.<br>
|
||||
A value of "2" select both of the above and create a combined and
|
||||
A value of "2" selects both of the above and creates the combined and
|
||||
the seperate readings at the same time, this should only be used
|
||||
if really needed as more or less duplicate events are generated.
|
||||
if really needed as duplicate events are generated.
|
||||
</li>
|
||||
|
||||
<li><a href="#ignore">ignore</a></li>
|
||||
@ -5591,16 +5572,16 @@ s2Hex($)
|
||||
"alarm_<alarmType>.</li>
|
||||
<li>Devices with class version 1 support: alarm_type_X:level Y</li>
|
||||
<li>For higher class versions more detailed events with 100+ different
|
||||
strings in the form alarm:<string>
|
||||
(or alarm_<alarmType>:<string>) are generated.<br>
|
||||
For the combined reading, the name of the alarm type is part of
|
||||
the reading event, for separate readings it is part of the
|
||||
reading name.<br>
|
||||
If a cleared event can be identified, the string "Event cleared:"
|
||||
is reported before the event details.<br>
|
||||
The seperate readings also contain the status of the
|
||||
alarmnotification. For compatibility reasons this is currently
|
||||
not supported with the combined reading. </li>
|
||||
strings in the form alarm:<string>
|
||||
(or alarm_<alarmType>:<string>) are generated.<br>
|
||||
For the combined reading, the name of the alarm type is part of
|
||||
the reading event, for separate readings it is part of the
|
||||
reading name.<br>
|
||||
If a cleared event can be identified, the string "Event cleared:"
|
||||
is reported before the event details.<br>
|
||||
The seperate readings also contain the status of the
|
||||
alarm / notification. For compatibility reasons this is currently
|
||||
not supported with the combined reading. </li>
|
||||
|
||||
<br><b>Class APPLICATION_STATUS</b>
|
||||
<li>applicationStatus: [cmdRejected]</li>
|
||||
|
Loading…
x
Reference in New Issue
Block a user