2
0
mirror of https://github.com/fhem/fhem-mirror.git synced 2025-03-03 16:56:54 +00:00

zwave.template: add ZW100, enhance Fibaro shutter variants

git-svn-id: https://svn.fhem.de/fhem/trunk@22926 2b470e98-0d58-463d-a4d8-8e2adae1ed80
This commit is contained in:
Beta-User 2020-10-06 06:51:14 +00:00
parent 4a18189fe5
commit cc4a80c27b

View File

@ -30,7 +30,7 @@ deletereading -q TYPE=ZWave (UNPARSED|SEND_DATA|CMD)
name:zwave_get_myutils_from_svn
filter:TYPE=ZWave
desc:template to download or update additional code from svn
desc:template to download or update additional code from svn. Code ist necessary for quite a lot of these templates to work, so first do this...
order:000002
{ Svn_GetFile("contrib/AttrTemplate/99_attrT_ZWave_Utils.pm", "FHEM/99_attrT_ZWave_Utils.pm", sub(){CommandReload(undef, "99_attrT_ZWave_Utils")}) }
@ -52,7 +52,10 @@ name:FGRM222_Roller_Mode
filter:TYPE=ZWave
order:01Fibaro000005
desc:Applies to Fibaro FGRM222 devices. This is for normal shutter mode. For other modes use different attrTemplates if available or manual configuration.
farewell:Things to be done manually: configure switch type (configSwitchType).
farewell:No Problem encountered, enjoy!
par:RADIO_SCENES_ACTIVATION;Send scenes events when buttons are pressed;{ undef }
par:RADIO_ASSOCIATIONS_ACTIVATION;Do not send scene events when buttons are pressed;{ undef }
par:SWITCHTYPE;Possible values: 0-2 (0=MomentarySwitches, 1=ToggleSwitches, 2=SingleMomentarySwitch);{ undef }
par:CALLSPEECHRECOGN;Set this to 0 to not set any speech recogn. related attributes;{ 1 }
par:ICON;ICON as set, defaults to fts_shutter_updown;{ AttrVal("DEVICE","icon","fts_shutter_updown") }
attr DEVICE icon ICON
@ -63,6 +66,11 @@ attr DEVICE cmdIcon stop:fts_shutter_manual
attr DEVICE widgetOverride dim:colorpicker,BRI,0,1,99
set DEVICE configRollerShutterOperatingModes 1RollerBlindModeWithPositioning
set DEVICE configReportsType BlindPositionReportsSentToThe0
set DEVICE configByte 14 SWITCHTYPE
option:{ RADIO_SCENES_ACTIVATION }
set DEVICE configScenesAssociationsActivation ScenesActivation
option:{ RADIO_ASSOCIATIONS_ACTIVATION }
set DEVICE configScenesAssociationsActivation AssociationsActivation
option:{ CALLSPEECHRECOGN }
set DEVICE attrTemplate speechcontrol_type_blind
#closing section
@ -76,7 +84,10 @@ name:FGRM222_Ventian_Blind_Mode
filter:TYPE=ZWave
order:01Fibaro000005a
desc:Applies to Fibaro FGRM222 devices. This is for venetian blind mode. For other modes use differnt attrTemplates or manual configuration. Note: additional code needed - has to be downloaded seperately from svn.
farewell:Things to be done manually: configure switch type (configSwitchType) and turning time for lamellas (configInVenetianBlindModeTheParameter12).
farewell:Things to be done manually: adopt turning time for lamellas (configInVenetianBlindModeTheParameter12) if needed.
par:RADIO_SCENES_ACTIVATION;Send scenes events when buttons are pressed;{ undef }
par:RADIO_ASSOCIATIONS_ACTIVATION;Do not send scene events when buttons are pressed;{ undef }
par:SWITCHTYPE;Possible values: 0-2 (0=MomentarySwitches, 1=ToggleSwitches, 2=SingleMomentarySwitch);{ undef }
par:CALLSPEECHRECOGN;Set this to 0 to not set any speech recogn. related attributes;{ 1 }
par:ICON;ICON as set, defaults to fts_shutter_updown;{ AttrVal("DEVICE","icon","fts_shutter_updown") }
attr DEVICE icon ICON
@ -88,7 +99,12 @@ attr DEVICE devStateIcon { FHEM::attrT_ZWave_Utils::devStateIcon_shutter($name,"
set DEVICE configRollerShutterOperatingModes 2VenetianBlindModeWith2
set DEVICE configReportsType BlindPositionReportsSentToThe1
set DEVICE configSetLamellasBackToPrevious13 0LamellasReturnToPreviouslySet0
set DEVICE configByte 14 SWITCHTYPE
attr DEVICE userReadings dim:power..0.0.W {my $pos = ReadingsVal($name,"state",0) =~ m,dim, ? ReadingsNum($name,"state",0) : ReadingsNum($name,"dim",0);; my $pos1 = ReadingsNum($name,"position",0);; $pos = $pos1 if ($pos > $pos1 +3 || $pos < $pos1 -3);; return $pos }, positionSlat:power..0.0.W {ReadingsVal($name,"position",0) =~ m,Slat.([0-9]+),?$1:undef}
option:{ RADIO_SCENES_ACTIVATION }
set DEVICE configScenesAssociationsActivation ScenesActivation
option:{ RADIO_ASSOCIATIONS_ACTIVATION }
set DEVICE configScenesAssociationsActivation AssociationsActivation
option:{ CALLSPEECHRECOGN }
set DEVICE attrTemplate speechcontrol_type_blind
#closing section
@ -135,7 +151,10 @@ name:FGR223_Roller_Mode
filter:TYPE=ZWave
order:01Fibaro000006
desc:Applies to Fibaro FGR223 devices. This is for normal shutter mode. For other modes use different attrTemplates if available or manual configuration.
farewell:Things to be done manually: configure switch type (configSwitchType).
farewell:No Problem encountered, enjoy! In case you activated scene events at keypresses, events will be shown in the main channel device.
par:RADIO_SCENES_ACTIVATION;Send scenes events when buttons are pressed;{ undef }
par:RADIO_ASSOCIATIONS_ACTIVATION;Do not send scene events when buttons are pressed;{ undef }
par:SWITCHTYPE;Possible values: 0-2 (0=MomentarySwitches, 1=ToggleSwitches, 2=SingleMomentarySwitch);{ undef }
par:CALLSPEECHRECOGN;Set this to 0 to not set any speech recogn. related attributes;{ 1 }
par:MAINCHANNEL;Main channel of the device - do not proceed if it can't be identified!;{ FHEM::attrT_ZWave_Utils::identify_channel_devices("DEVICE",0) }
par:CHANNEL01;First channel of the device - do not proceed if it can't be identified!;{ FHEM::attrT_ZWave_Utils::identify_channel_devices("DEVICE",1) }
@ -148,14 +167,20 @@ attr CHANNEL01 webCmd dim
attr CHANNEL01 widgetOverride dim:colorpicker,BRI,0,1,99
attr CHANNEL01 userReadings dim:(dim|reportedState).* {$1 =~ /reportedState/ ? ReadingsNum($name,"reportedState",0):ReadingsNum($name,"state",0)}
set MAINCHANNEL configEnergyReportsOnChange 10
option:{ RADIO_SCENES_ACTIVATION }
set MAINCHANNEL configS1SwitchScenesSent 15
set MAINCHANNEL configS2SwitchScenesSent 15
option:{ RADIO_ASSOCIATIONS_ACTIVATION }
set MAINCHANNEL configS1SwitchScenesSent 0
set MAINCHANNEL configS2SwitchScenesSent 0
option:{ 1 }
set MAINCHANNEL configByte 20 SWITCHTYPE
set MAINCHANNEL configOperatingMode RollerBlind
set MAINCHANNEL configForceCalibration ForceDeviceCalibration
option:{ CALLSPEECHRECOGN }
set CHANNEL01 attrTemplate speechcontrol_type_blind
#closing section
option:{ 1 }
option:{ 1 }
get MAINCHANNEL configAll
get MAINCHANNEL associationAll
{ fhem "trigger $FW_wname JS:location.href='$FW_ME?room=%23devspec%3dMAINCHANNEL,CHANNEL01,CHANNEL02'" if($cl && $cl->{TYPE} eq "FHEMWEB") }
@ -165,7 +190,10 @@ name:FGR223_Venetian_Mode
filter:TYPE=ZWave
order:01Fibaro000006a
desc:Applies to Fibaro FGR223 devices. This is for venetian blind mode. For other modes use differnt attrTemplates or manual configuration.<br>The template is based on this <a href https://forum.fhem.de/index.php/topic,100390.0.html>forum thread</a>.
farewell:Things to be done manually: configure switch type (configSwitchType).
farewell:Things to be done manually: adopt turning time for lamellas (configVenetianBlindTimeOfFullTurnOfThe152) if needed. In case you activated scene events at keypresses, events will be shown in the main channel device.
par:RADIO_SCENES_ACTIVATION;Send scenes events when buttons are pressed;{ undef }
par:RADIO_ASSOCIATIONS_ACTIVATION;Do not send scene events when buttons are pressed;{ undef }
par:SWITCHTYPE;Possible values: 0-2 (0=MomentarySwitches, 1=ToggleSwitches, 2=SingleMomentarySwitch);{ undef }
par:CALLSPEECHRECOGN;Set this to 0 to not set any speech recogn. related attributes;{ 1 }
par:MAINCHANNEL;Main channel of the device - do not proceed if it can't be identified!;{ FHEM::attrT_ZWave_Utils::identify_channel_devices("DEVICE",0) }
par:CHANNEL01;First channel of the device - do not proceed if it can't be identified!;{ FHEM::attrT_ZWave_Utils::identify_channel_devices("DEVICE",1) }
@ -178,9 +206,15 @@ attr CHANNEL01 webCmd dim
attr CHANNEL01 widgetOverride dim:colorpicker,BRI,0,1,99
attr CHANNEL01 userReadings dim:(dim|reportedState).* {$1 =~ /reportedState/ ? ReadingsNum($name,"reportedState",0):ReadingsNum($name,"state",0)}
set MAINCHANNEL configEnergyReportsOnChange 10
option:{ RADIO_SCENES_ACTIVATION }
set MAINCHANNEL configS1SwitchScenesSent 15
set MAINCHANNEL configS2SwitchScenesSent 15
option:{ RADIO_ASSOCIATIONS_ACTIVATION }
set MAINCHANNEL configS1SwitchScenesSent 0
set MAINCHANNEL configS2SwitchScenesSent 0
option:{ 1 }
set MAINCHANNEL configOperatingMode VenetianBlind
set MAINCHANNEL configByte 20 SWITCHTYPE
set MAINCHANNEL configForceCalibration ForceDeviceCalibration
option:{ CALLSPEECHRECOGN }
set CHANNEL01 attrTemplate speechcontrol_type_blind
@ -201,7 +235,7 @@ desc:Templates for AEOTEC/AEON Labs devices.Manufacturer info can be found <a hr
name:ZW095_Home_Energy_Meter
filter:TYPE=ZWave
order:03AEOTEC0000ZW095
desc:Applies to AEON Labs ZW095 Home Energy Meter Gen5 .<br>NOTE: early, untested version!<br>The template is based on this <a href https://forum.fhem.de/index.php/topic,112682.0.html>forum thread</a>, manufacturer info can be found <a href https://aeotec.freshdesk.com/support/solutions/folders/6000217020>here</a>. Having an up-to-date firmware is highly recommended
desc:Applies to AEON Labs ZW095 Home Energy Meter Gen5 .<br>NOTE: early, untested version!<br>The template is based on this <a href https://forum.fhem.de/index.php/topic,112682.0.html>forum thread</a>, manufacturer info can be found <a href https://aeotec.freshdesk.com/support/solutions/folders/6000217020>here</a>.
par:MAINCHANNEL;Main channel of the device - do not proceed if it can't be identified!;{ FHEM::attrT_ZWave_Utils::identify_channel_devices("DEVICE",0) }
par:CHANNEL01;First channel of the device - do not proceed if it can't be identified!;{ FHEM::attrT_ZWave_Utils::identify_channel_devices("DEVICE",1) }
par:CHANNEL02;Second channel of the device - do not proceed if it can't be identified!;{ FHEM::attrT_ZWave_Utils::identify_channel_devices("DEVICE",2) }
@ -223,7 +257,42 @@ get MAINCHANNEL associationAll
{ fhem "trigger $FW_wname JS:location.href='$FW_ME?room=%23devspec%3dMAINCHANNEL,CHANNEL01,CHANNEL02,CHANNEL03'" if($cl && $cl->{TYPE} eq "FHEMWEB") }
setreading DEVICE attrTemplateVersion ZW095_Home_Energy_Meter_20200930
name:ZW100_Multisensor
name:ZW100_Multisensor_Battery
filter:TYPE=ZWave
order:03AEOTEC0000ZW100
desc:Having an up-to-date firmware is highly recommended
desc:Applies to AEON Labs ZW100 MultiSensor 6 when battery powered.<br>NOTE: early version!<br>The template is based on this <a href https://forum.fhem.de/index.php/topic,114538.0.html</a>, manufacturer info can be found <a href https://aeotec.freshdesk.com/support/solutions/folders/6000149641>here</a>. Having an up-to-date firmware is highly recommended!
par:RADIO_REPORT_UV;Send also UV values;{ undef }
par:RADIO_NO_UV_REPORT;Do not send UV values;{ undef }
set DEVICE configGroup1Interval 3600
set DEVICE configByte 40 0
#configReportOnlyOnThresholds Disabled
option:{ RADIO_REPORT_UV}
set DEVICE configGroup1Reports 241
option:{ RADIO_NO_UV_REPORT }
set DEVICE configGroup1Reports 113
option:{ 1 }
get DEVICE configGroup1Interval
get DEVICE configReportOnlyOnThresholds
get DEVICE configGroup1Reports
setreading DEVICE attrTemplateVersion ZW100_Multisensor_Battery_20201006
name:ZW100_Multisensor_USB
filter:TYPE=ZWave
order:03AEOTEC0000ZW100a
desc:Applies to AEON Labs ZW100 MultiSensor 6 when powered over USB.<br>NOTE: early version!<br>The template is based on this <a href https://forum.fhem.de/index.php/topic,114538.0.html</a>, manufacturer info can be found <a href https://aeotec.freshdesk.com/support/solutions/folders/6000149641>here</a>. Having an up-to-date firmware is highly recommended!
par:RADIO_REPORT_UV;Send also UV values;{ undef }
par:RADIO_NO_UV_REPORT;Do not send UV values;{ undef }
set DEVICE configGroup1Interval 30
set DEVICE configByte 40 1
#configReportOnlyOnThresholds Enabled
option:{ RADIO_REPORT_UV}
set DEVICE configGroup1Reports 240
option:{ RADIO_NO_UV_REPORT }
set DEVICE configGroup1Reports 112
#closing section
option:{ 1 }
get DEVICE configAll
setreading DEVICE attrTemplateVersion ZW100_Multisensor_USB_20201006