diff --git a/fhem/FHEM/00_ElsnerWS.pm b/fhem/FHEM/00_ElsnerWS.pm index 410859029..de7dab8b8 100644 --- a/fhem/FHEM/00_ElsnerWS.pm +++ b/fhem/FHEM/00_ElsnerWS.pm @@ -1081,29 +1081,29 @@ sub ElsnerWS_Delete($$) { if the thresholds are permanently undershot or exceed during the delay time.
  • brightnessSunnyEast E_min/lx:E_max/lx, - [brightnessSunny] = 0...99000:0...99000, 20000:40000 is default.
    + [brightnessSunnyEast] = 0...99000:0...99000, 20000:40000 is default.
    Set switching thresholds for reading isSunnyEast based on the reading sunEast.
  • brightnessSunnyEastDelay t_reset/s:t_set/s, - [brightnessSunnyDelay] = 0...3600:0...3600, 120:30 is default.
    + [brightnessSunnyEastDelay] = 0...3600:0...3600, 120:30 is default.
    Set switching delay for reading isSunnyEast based on the reading sunEast. The reading isSunnyEast is reset or set if the thresholds are permanently undershot or exceed during the delay time.
  • brightnessSunnySouth E_min/lx:E_max/lx, - [brightnessSunny] = 0...99000:0...99000, 20000:40000 is default.
    + [brightnessSunnySouth] = 0...99000:0...99000, 20000:40000 is default.
    Set switching thresholds for reading isSunnySouth based on the reading sunSouth.
  • brightnessSunnySouthDelay t_reset/s:t_set/s, - [brightnessSunnyDelay] = 0...3600:0...3600, 120:30 is default.
    + [brightnessSunnySouthDelay] = 0...3600:0...3600, 120:30 is default.
    Set switching delay for reading isSunnySouth based on the reading sunSouth. The reading isSunnySouth is reset or set if the thresholds are permanently undershot or exceed during the delay time.
  • brightnessSunnyWest E_min/lx:E_max/lx, - [brightnessSunny] = 0...99000:0...99000, 20000:40000 is default.
    + [brightnessSunnyWest] = 0...99000:0...99000, 20000:40000 is default.
    Set switching thresholds for reading isSunnyWest based on the reading sunWest.
  • brightnessSunnyWestDelay t_reset/s:t_set/s, - [brightnessSunnyDelay] = 0...3600:0...3600, 120:30 is default.
    + [brightnessSunnyWestDelay] = 0...3600:0...3600, 120:30 is default.
    Set switching delay for reading isSunnyWest based on the reading sunWest. The reading isSunnyWest is reset or set if the thresholds are permanently undershot or exceed during the delay time.