From c36800b26f3f6ce7ba5d34eaca33d41b5f721c58 Mon Sep 17 00:00:00 2001
From: Beta-User <>
Date: Sun, 3 Nov 2019 07:07:45 +0000
Subject: [PATCH] mqtt2.template: add ems-esp to bridgeRegexp CLIENT-tamplate;
point tasmota roller to official sources
git-svn-id: https://svn.fhem.de/fhem/trunk@20444 2b470e98-0d58-463d-a4d8-8e2adae1ed80
---
fhem/FHEM/lib/AttrTemplate/mqtt2.template | 17 +++++++++--------
1 file changed, 9 insertions(+), 8 deletions(-)
diff --git a/fhem/FHEM/lib/AttrTemplate/mqtt2.template b/fhem/FHEM/lib/AttrTemplate/mqtt2.template
index 01350a946..2be31c77f 100644
--- a/fhem/FHEM/lib/AttrTemplate/mqtt2.template
+++ b/fhem/FHEM/lib/AttrTemplate/mqtt2.template
@@ -32,7 +32,8 @@ attr DEVCID bridgeRegexp \
(tele|cmnd)[/]([^/]+)[/].*:.* "$2"\
shellies[/]([^/]+)[/].*:.* "$1"\
(ESPClient_[^/]+)[/].*:.* "$1"\
- valetudo[/]([^/]+)[/].*:.* "$1"
+ valetudo[/]([^/]+)[/].*:.* "$1"\
+ [^/]+[/](ems-esp[^/]+)[/].*:.* "$1"
attr DEVCID autocreate 1
attr DEVCID comment Do not use very open bridgeRegexp expressions! This might lead to irritating results...
attr DEVCID room NEWDEVROOM
@@ -717,14 +718,14 @@ attr DEVICE_CH2 model tasmota_2channel_split
# tasmota 2ch as shutter device.
name:tasmota_2ch_shutter_invert_1
filter:TYPE=MQTT2_DEVICE:FILTER=readingList=.*(tele|cmnd|stat).*
-desc:Configures a dual chanel tasmota device as shutter; needs a special firmware version to operate.
Forum Thread
NOTE: This template will configure the shutter in ROLLO style with pct 0% = open shutter. Use template tasmota_2ch_shutter_invert_0, if you need a Homematic-style device pct 100% = open.
+desc:Configures a dual chanel tasmota device as shutter; needs some configuration of firmware compilation to operate, see Tasmota wiki
and Forum Thread
NOTE: This template will configure the shutter in ROLLO style with pct 0% = open shutter. Use template tasmota_2ch_shutter_invert_0, if you need a Homematic-style device pct 100% = open.
order:A_02b
par:CMNDTOPIC;Command topic prefix, without trailing /;{ AttrVal("DEVICE","readingList","") =~ m,([^:]*)\b(tele|cmnd|stat)(/.*)?/LWT:, ? "${1}cmnd$3" : undef }
par:TELETOPIC;info topic prefix, without trailing /;{ AttrVal("DEVICE","readingList","") =~ m,([^:]*)\b(tele|cmnd|stat)(/.*)?/LWT:, ? "${1}tele$3" : undef }
par:STATTOPIC;ack topic prefix, without trailing /;{ AttrVal("DEVICE","readingList","") =~ m,([^:]*)\b(tele|cmnd|stat)(/.*)?/LWT:, ? "${1}stat$3" : undef }
par:IO_DEV;Currently used IO;{ AttrVal("DEVICE","IODev",undef)}
set DEVICE attrTemplate tasmota_set_lowercase_texts_and_state1
-set IO_DEV publish CMNDTOPIC/Backlog LedState 2; SetOption80 1; Interlock0 1; SetOption81 1; switchmode1 3; switchmode2 3; SaveData 1;
+set IO_DEV publish CMNDTOPIC/Backlog LedState 2; SetOption80 1; Interlock 1,2; Interlock ON; SetOption81 1; switchmode1 3; switchmode2 3; PulseTime1 0; PulseTime2 0; SaveData 1;
set IO_DEV publish CMNDTOPIC/Restart 1
defmod configure_DEVICEattrTemplate_at at +00:00:20 set IO_DEV publish CMNDTOPIC/Backlog SHUTTEROPENDURATION 20;; SHUTTERCLOSEDURATION 20;; SHUTTERINVERT 1;; GROUPTOPIC Rollos;; SaveData 1;;
attr DEVICE setList \
@@ -758,18 +759,18 @@ LWT\
state
deletereading -q DEVICE (?!associatedWith).*
attr DEVICE setStateList open close half stop pct
-attr DEVICE comment After applying the template set SHUTTEROPENDURATION and SHUTTERCLOSEDURATION first.\
-Use the "set x_configuration" Option. Example: "set x_configuration SHUTTEROPENDURATION 35"\
-Shutter specific commands available: SHUTTEROPENDURATION, SHUTTERCLOSEDURATION, SHUTTERRELAY, SHUTTER50PERCENT, SHUTTERSETCLOSE, SHUTTERINVERT; you may use this for general setOptions in tasmota also.\
+attr DEVICE comment After applying the template set "ShutterOpenDuration" and "ShutterCloseDuration" first.\
+Use the "set x_configuration" Option. Example: "set x_configuration ShutterOpenDuration 35"\
+Shutter specific commands available: ShutterOpenDuration, ShutterCloseDuration, ShutterRelay, ShutterSetHalfway, ShutterSetClose, ShutterInvert, ShutterMotordelay, ShutterCalibration; you may use this for general setOptions in tasmota also.\
commands may need restart to take effect.\
-For calibration and further information on the available commands see https://github.com/stefanbode/Sonoff-Tasmota/wiki/Shutter-blinds-working-with-two-relays.
+For calibration and further information on the available commands see Tasmota wiki.
farewell:template has been applied successfully. Now it's recommended to set shutter's open and close duration and 50% position, see short instruction in comment attribute or the
firmware contributor's wiki.
attr DEVICE model tasmota_2ch_shutter_invert_1
# tasmota 2ch as shutter device.
name:tasmota_2ch_shutter_invert_0
filter:TYPE=MQTT2_DEVICE:FILTER=readingList=.*(tele|cmnd|stat).*
-desc:Configures a dual chanel tasmota device as shutter; needs a special firmware version to operate.
Forum Thread
NOTE: This template will configure the shutter in Homematic-style with pct 100% = open. For ROLLO style device with pct 0% = open shutter. Use template tasmota_2ch_shutter_invert_1 instead.
+desc:Configures a dual chanel tasmota device as shutter; needs some configuration of firmware compilation to operate, see Tasmota wiki
and Forum Thread
NOTE: This template will configure the shutter in Homematic-style with pct 100% = open. For ROLLO style device with pct 0% = open shutter. Use template tasmota_2ch_shutter_invert_1 instead.
order:A_02b1
par:CMNDTOPIC;Command topic prefix, without trailing /;{ AttrVal("DEVICE","readingList","") =~ m,([^:]*)\b(tele|cmnd|stat)(/.*)?/LWT:, ? "${1}cmnd$3" : undef }
par:IO_DEV;Currently used IO;{ AttrVal("DEVICE","IODev",undef)}