98_ModbusAttr.pm: fix documentation

git-svn-id: https://svn.fhem.de/fhem/trunk@23626 2b470e98-0d58-463d-a4d8-8e2adae1ed80
This commit is contained in:
StefanStrobel 2021-01-27 15:18:38 +00:00
parent 23525e281f
commit c30eea3159

View File

@ -370,7 +370,7 @@ sub Initialize {
<ul> <ul>
are created based on the attributes defining the data objects.<br> are created based on the attributes defining the data objects.<br>
Every object for which an attribute like <code>obj-xy-set</code> is set to 1 will create a valid set option.<br> Every object for which an attribute like <code>obj-xy-set</code> is set to 1 will create a valid set option.<br>
Additionally the attribute <code>enableControlSet</code> enables the set options <code>interval</code>, <code>stop</code>, <code>start</code>, <code>reread</code> as well as <code>scanModbusObjects</code>, <code>scanStop</code> and <code>scanModbusIds</code> (for devices connected with RTU / ASCII over a serial line).<br> Additionally the attribute <code>enableControlSet</code> enables the set options <code>interval</code>, <code>stop</code>, <code>start</code>, <code>reread</code> as well as <code>scanModbusObjects</code>, <code>scanStop</code> and <code>scanModbusId</code> (for devices connected with RTU / ASCII over a serial line).<br>
Starting with Version 4 of the Modbus module enableControlSet defaults to 1.<br> Starting with Version 4 of the Modbus module enableControlSet defaults to 1.<br>
<ul> <ul>
<li><code>interval &lt;Interval&gt;</code></li> <li><code>interval &lt;Interval&gt;</code></li>
@ -390,7 +390,7 @@ sub Initialize {
<code>scan-h100 hex=0021, string=.!, s=8448, s>=33, S=8448, S>=33</code><br> <code>scan-h100 hex=0021, string=.!, s=8448, s>=33, S=8448, S>=33</code><br>
the representation of the result as hex is 0021 and the representation of the result as hex is 0021 and
the ASCII representation is .!. s, s>, S and S> are different representations with their Perl pack-code. the ASCII representation is .!. s, s>, S and S> are different representations with their Perl pack-code.
<li><code>scanModbusIds &lt;startId&gt; - &lt;endId&gt; &lt;knownObj&gt;</code></li> <li><code>scanModbusId &lt;startId&gt; - &lt;endId&gt; &lt;knownObj&gt;</code></li>
scans for Modbus Ids on an RS485 Bus. The following set command for example starts a scan:<br> scans for Modbus Ids on an RS485 Bus. The following set command for example starts a scan:<br>
<code>set Device scanModbusId 1-7 h770</code><br> <code>set Device scanModbusId 1-7 h770</code><br>
since many modbus devices don't reply at all if an object is requested that does not exist, scanModbusId since many modbus devices don't reply at all if an object is requested that does not exist, scanModbusId