mirror of
https://github.com/fhem/fhem-mirror.git
synced 2025-03-10 09:16:53 +00:00
15_CUL_EM.pm: added attribute "maxPeak" to make
device readings more robust git-svn-id: https://svn.fhem.de/fhem/trunk@6825 2b470e98-0d58-463d-a4d8-8e2adae1ed80
This commit is contained in:
parent
b40a4a32e8
commit
c2a5188de5
@ -23,6 +23,7 @@ CUL_EM_Initialize($)
|
||||
$hash->{ParseFn} = "CUL_EM_Parse";
|
||||
$hash->{AttrList} = "IODev do_not_notify:0,1 showtime:0,1 " .
|
||||
"model:EMEM,EMWZ,EMGZ ignore:0,1 ".
|
||||
"maxPeak ".
|
||||
$readingFnAttributes;
|
||||
$hash->{AutoCreate}=
|
||||
{ "CUL_EM.*" => { GPLOT => "power8:Power,", FILTER => "%NAME:CNT.*" } };
|
||||
@ -138,12 +139,6 @@ CUL_EM_Parse($$)
|
||||
$basis_cnt = $hash->{READINGS}{basis}{VAL};
|
||||
}
|
||||
|
||||
# correct counter wraparound
|
||||
if($total_cnt < $total_cnt_last) {
|
||||
# check: real wraparound or reset only
|
||||
$basis_cnt += ($total_cnt_last > 65000 ? 65536 : $total_cnt_last);
|
||||
$readings{basis} = $basis_cnt;
|
||||
}
|
||||
|
||||
#
|
||||
# translate into device units
|
||||
@ -151,18 +146,44 @@ CUL_EM_Parse($$)
|
||||
my $corr1 = $hash->{corr1}; # EMEM power correction factor
|
||||
my $corr2 = $hash->{corr2}; # EMEM energy correction factor
|
||||
|
||||
my $total = ($basis_cnt+$total_cnt)*$corr2;
|
||||
my $current = $current_cnt*$corr1;
|
||||
my $peak = $peak_cnt*$corr1;
|
||||
my $peak;
|
||||
|
||||
if($tpe ne 2) {
|
||||
$peak = 3000/($peak_cnt > 1 ? $peak_cnt : 1)*$corr1;
|
||||
$peak = ($current > 0 ? $peak : 0);
|
||||
$peak = $current_cnt && $peak_cnt ? 3000/$peak_cnt*$corr1 : 0;
|
||||
# when EM detection toggles/glitches somewhere the internal
|
||||
# EM-Counter increments by one and the device registers a
|
||||
# very hi peak value
|
||||
# Here we fix this by checking against a maximum peak
|
||||
# level, removing the wrong counter increment and
|
||||
# setting peak to the current value.
|
||||
my $maxpeak = $attr{$n}{"maxPeak"};
|
||||
if(defined $maxpeak and $peak > $maxpeak){
|
||||
Log3 $n, 2,
|
||||
"CUL_EM $n: max peak detected: $peak kW > $maxpeak kW";
|
||||
$current_cnt--;
|
||||
# as total_cnt is "owned" by EM we decrement our basis_cnt
|
||||
$basis_cnt--;
|
||||
$readings{basis} = $basis_cnt;
|
||||
$peak = $current_cnt*$corr1;
|
||||
$peak_cnt = $peak ? int(3000*$corr1/$peak) : 0;
|
||||
}
|
||||
} else {
|
||||
$peak = $peak_cnt*$corr1;
|
||||
}
|
||||
|
||||
# correct counter wraparound
|
||||
if($total_cnt < $total_cnt_last) {
|
||||
# check: real wraparound or reset only
|
||||
$basis_cnt += ($total_cnt_last > 65000 ? 65536 : $total_cnt_last);
|
||||
$readings{basis} = $basis_cnt;
|
||||
}
|
||||
|
||||
my $total = ($basis_cnt+$total_cnt)*$corr2;
|
||||
my $current = $current_cnt*$corr1;
|
||||
|
||||
$val = sprintf("CNT: %d CUM: %0.3f 5MIN: %0.3f TOP: %0.3f",
|
||||
$seqno, $total, $current, $peak);
|
||||
$seqno, $total, $current, $peak);
|
||||
|
||||
readingsBeginUpdate($hash);
|
||||
readingsBulkUpdate($hash, "state", $val);
|
||||
|
||||
@ -321,7 +342,15 @@ CUL_EM_Parse($$)
|
||||
<li><a href="#model">model</a> (EMEM,EMWZ,EMGZ)</li><br>
|
||||
<li><a href="#IODev">IODev</a></li><br>
|
||||
<li><a href="#eventMap">eventMap</a></li><br>
|
||||
<li><a href="#readingFnAttributes">readingFnAttributes</a></li>
|
||||
<li><a href="#readingFnAttributes">readingFnAttributes</a></li><br>
|
||||
<li><a name="maxPeak">maxPeak</a> <number><br>
|
||||
Specifies the maximum possible peak value for the EM meter
|
||||
("TOP:" value in logfile). Peak values greater than this value
|
||||
are considered as EM read errors and are ignored.
|
||||
For example if it's not possible to consume more than 40kW of
|
||||
power set maxPeak to 40 to make the readings of the power meter
|
||||
more robust.
|
||||
</li>
|
||||
</ul>
|
||||
<br>
|
||||
</ul>
|
||||
@ -395,7 +424,15 @@ CUL_EM_Parse($$)
|
||||
<li><a href="#model">model</a> (EMEM,EMWZ,EMGZ)</li><br>
|
||||
<li><a href="#IODev">IODev</a></li><br>
|
||||
<li><a href="#eventMap">eventMap</a></li><br>
|
||||
<li><a href="#readingFnAttributes">readingFnAttributes</a></li>
|
||||
<li><a href="#readingFnAttributes">readingFnAttributes</a></li><br>
|
||||
<li><a name="maxPeak">maxPeak</a> <number><br>
|
||||
Gibt den maximal möglichen Spitzenwert für das EM-Meter an
|
||||
("TOP:"-Wert in Logdatei). Spitzenwerte größer als dieser
|
||||
Wert gelten als EM-Lesefehler und werden ignoriert.
|
||||
Wenn es z.B. nicht möglich ist mehr zu 40kW Leistung
|
||||
zu beziehen setzt man maxPeak auf 40 um das Auslesen des
|
||||
Stromzählers robuster zu machen.
|
||||
</li>
|
||||
</ul>
|
||||
<br>
|
||||
</ul>
|
||||
|