15_CUL_EM.pm: added attribute "maxPeak" to make

device readings more robust


git-svn-id: https://svn.fhem.de/fhem/trunk@6825 2b470e98-0d58-463d-a4d8-8e2adae1ed80
This commit is contained in:
arnoaugustin 2014-10-28 09:25:24 +00:00
parent b40a4a32e8
commit c2a5188de5

View File

@ -23,6 +23,7 @@ CUL_EM_Initialize($)
$hash->{ParseFn} = "CUL_EM_Parse";
$hash->{AttrList} = "IODev do_not_notify:0,1 showtime:0,1 " .
"model:EMEM,EMWZ,EMGZ ignore:0,1 ".
"maxPeak ".
$readingFnAttributes;
$hash->{AutoCreate}=
{ "CUL_EM.*" => { GPLOT => "power8:Power,", FILTER => "%NAME:CNT.*" } };
@ -138,12 +139,6 @@ CUL_EM_Parse($$)
$basis_cnt = $hash->{READINGS}{basis}{VAL};
}
# correct counter wraparound
if($total_cnt < $total_cnt_last) {
# check: real wraparound or reset only
$basis_cnt += ($total_cnt_last > 65000 ? 65536 : $total_cnt_last);
$readings{basis} = $basis_cnt;
}
#
# translate into device units
@ -151,18 +146,44 @@ CUL_EM_Parse($$)
my $corr1 = $hash->{corr1}; # EMEM power correction factor
my $corr2 = $hash->{corr2}; # EMEM energy correction factor
my $total = ($basis_cnt+$total_cnt)*$corr2;
my $current = $current_cnt*$corr1;
my $peak = $peak_cnt*$corr1;
my $peak;
if($tpe ne 2) {
$peak = 3000/($peak_cnt > 1 ? $peak_cnt : 1)*$corr1;
$peak = ($current > 0 ? $peak : 0);
$peak = $current_cnt && $peak_cnt ? 3000/$peak_cnt*$corr1 : 0;
# when EM detection toggles/glitches somewhere the internal
# EM-Counter increments by one and the device registers a
# very hi peak value
# Here we fix this by checking against a maximum peak
# level, removing the wrong counter increment and
# setting peak to the current value.
my $maxpeak = $attr{$n}{"maxPeak"};
if(defined $maxpeak and $peak > $maxpeak){
Log3 $n, 2,
"CUL_EM $n: max peak detected: $peak kW > $maxpeak kW";
$current_cnt--;
# as total_cnt is "owned" by EM we decrement our basis_cnt
$basis_cnt--;
$readings{basis} = $basis_cnt;
$peak = $current_cnt*$corr1;
$peak_cnt = $peak ? int(3000*$corr1/$peak) : 0;
}
} else {
$peak = $peak_cnt*$corr1;
}
# correct counter wraparound
if($total_cnt < $total_cnt_last) {
# check: real wraparound or reset only
$basis_cnt += ($total_cnt_last > 65000 ? 65536 : $total_cnt_last);
$readings{basis} = $basis_cnt;
}
my $total = ($basis_cnt+$total_cnt)*$corr2;
my $current = $current_cnt*$corr1;
$val = sprintf("CNT: %d CUM: %0.3f 5MIN: %0.3f TOP: %0.3f",
$seqno, $total, $current, $peak);
$seqno, $total, $current, $peak);
readingsBeginUpdate($hash);
readingsBulkUpdate($hash, "state", $val);
@ -321,7 +342,15 @@ CUL_EM_Parse($$)
<li><a href="#model">model</a> (EMEM,EMWZ,EMGZ)</li><br>
<li><a href="#IODev">IODev</a></li><br>
<li><a href="#eventMap">eventMap</a></li><br>
<li><a href="#readingFnAttributes">readingFnAttributes</a></li>
<li><a href="#readingFnAttributes">readingFnAttributes</a></li><br>
<li><a name="maxPeak">maxPeak</a> &lt;number&gt;<br>
Specifies the maximum possible peak value for the EM meter
("TOP:" value in logfile). Peak values greater than this value
are considered as EM read errors and are ignored.
For example if it's not possible to consume more than 40kW of
power set maxPeak to 40 to make the readings of the power meter
more robust.
</li>
</ul>
<br>
</ul>
@ -395,7 +424,15 @@ CUL_EM_Parse($$)
<li><a href="#model">model</a> (EMEM,EMWZ,EMGZ)</li><br>
<li><a href="#IODev">IODev</a></li><br>
<li><a href="#eventMap">eventMap</a></li><br>
<li><a href="#readingFnAttributes">readingFnAttributes</a></li>
<li><a href="#readingFnAttributes">readingFnAttributes</a></li><br>
<li><a name="maxPeak">maxPeak</a> &lt;number&gt;<br>
Gibt den maximal m&ouml;glichen Spitzenwert f&uumlr das EM-Meter an
("TOP:"-Wert in Logdatei). Spitzenwerte gr&ouml;&szlig;er als dieser
Wert gelten als EM-Lesefehler und werden ignoriert.
Wenn es z.B. nicht m&ouml;glich ist mehr zu 40kW Leistung
zu beziehen setzt man maxPeak auf 40 um das Auslesen des
Stromz&auml;hlers robuster zu machen.
</li>
</ul>
<br>
</ul>