mirror of
https://github.com/fhem/fhem-mirror.git
synced 2025-03-03 04:36:36 +00:00
91_watchdog.pm: add regexp2WillReactivate attribute (Forum #113237)
git-svn-id: https://svn.fhem.de/fhem/trunk@22501 2b470e98-0d58-463d-a4d8-8e2adae1ed80
This commit is contained in:
parent
e732971ae3
commit
bcbe49a79e
@ -19,13 +19,14 @@ watchdog_Initialize($)
|
||||
$hash->{NotifyFn} = "watchdog_Notify";
|
||||
no warnings 'qw';
|
||||
my @attrList = qw(
|
||||
activateOnStart:0,1
|
||||
addStateEvent:0,1
|
||||
autoRestart:0,1
|
||||
disable:0,1
|
||||
activateOnStart:1,0
|
||||
addStateEvent:1,0
|
||||
autoRestart:1,0
|
||||
disable:1,0
|
||||
disabledForIntervals
|
||||
execOnReactivate
|
||||
regexp1WontReactivate:0,1
|
||||
regexp1WontReactivate:1,0
|
||||
regexp2WillReactivate:1,0
|
||||
);
|
||||
use warnings 'qw';
|
||||
$hash->{AttrList} = join(" ", @attrList);
|
||||
@ -123,6 +124,7 @@ watchdog_Notify($$)
|
||||
my $ln = $watchdog->{NAME};
|
||||
return "" if(IsDisabled($ln) || $watchdog->{STATE} eq "inactive");
|
||||
my $dontReAct = AttrVal($ln, "regexp1WontReactivate", 0);
|
||||
my $re2act = AttrVal($ln, "regexp2WillReactivate", 0);
|
||||
|
||||
my $n = $dev->{NAME};
|
||||
my $re1 = $watchdog->{RE1};
|
||||
@ -150,7 +152,7 @@ watchdog_Notify($$)
|
||||
|
||||
RemoveInternalTimer($watchdog);
|
||||
|
||||
if($re1 eq $re2 || $re1 eq ".") {
|
||||
if($re1 eq $re2 || $re1 eq "." || $re2act) {
|
||||
watchdog_Activate($watchdog);
|
||||
return "";
|
||||
|
||||
@ -369,7 +371,7 @@ watchdog_Set($@)
|
||||
<a name="watchdogattr"></a>
|
||||
<b>Attributes</b>
|
||||
<ul>
|
||||
<li><a name="#activateOnStart">activateOnStart</a><br>
|
||||
<li><a name="watchdogactivateOnStart">activateOnStart</a><br>
|
||||
if set, the watchdog will be activated after a FHEM start if appropriate,
|
||||
determined by the Timestamp of the Activated and the Triggered readings.
|
||||
Note: since between shutdown and startup events may be missed, this
|
||||
@ -380,14 +382,24 @@ watchdog_Set($@)
|
||||
<li><a href="#disable">disable</a></li>
|
||||
<li><a href="#disabledForIntervals">disabledForIntervals</a></li>
|
||||
|
||||
<li><a name="regexp1WontReactivate">regexp1WontReactivate</a><br>
|
||||
When a watchdog is active, a second event matching regexp1 will
|
||||
normally reset the timeout. Set this attribute to prevents this.</li>
|
||||
<li><a name="watchdogregexp1WontReactivate">regexp1WontReactivate</a><br>
|
||||
When a watchdog is active, a second event matching regexp1 will
|
||||
normally reset the timeout. Set this attribute to prevents this.
|
||||
</li><br>
|
||||
|
||||
<li><a name="watchdogregexp2WillReactivate">regexp2WillReactivate</a><br>
|
||||
Normally after an event matching regexp2 ist received, the watchdog is
|
||||
waiting for an event matching regexp1 to start the countdown. If this
|
||||
attribute set to 1 (the default 0), then after receivig an event
|
||||
matching regexp2 the countdown is reset and started. Note: if regexp1 and
|
||||
regexp2 are identical, or regexp2 is ., then this behavior is default.
|
||||
</li><br>
|
||||
|
||||
<li><a href="#execOnReactivate">execOnActivate</a>
|
||||
If set, its value will be executed as a FHEM command when the watchdog is
|
||||
reactivated (after triggering) by receiving an event matching regexp1.
|
||||
</li>
|
||||
</li><br>
|
||||
|
||||
<li><a href="#autoRestart">autoRestart</a>
|
||||
When the watchdog has triggered it will be automatically re-set to state
|
||||
defined again (waiting for regexp1) if this attribute is set to 1.
|
||||
@ -504,7 +516,7 @@ watchdog_Set($@)
|
||||
<a name="watchdogattr"></a>
|
||||
<b>Attribute</b>
|
||||
<ul>
|
||||
<li><a name="#activateOnStart">activateOnStart</a><br>
|
||||
<li><a name="watchdogactivateOnStart">activateOnStart</a><br>
|
||||
Falls gesetzt, wird der Watchdog nach FHEM-Neustart aktiviert, je nach
|
||||
Zeitstempel der Activated und Triggered Readings. Da zwischen Shutdown
|
||||
und Neustart Events verlorengehen können, ist die Voreinstellung 0
|
||||
@ -515,15 +527,26 @@ watchdog_Set($@)
|
||||
<li><a href="#addStateEvent">addStateEvent</a></li>
|
||||
<li><a href="#disable">disable</a></li>
|
||||
<li><a href="#disabledForIntervals">disabledForIntervals</a></li>
|
||||
<li><a name="regexp1WontReactivate">regexp1WontReactivate</a><br>
|
||||
<br>
|
||||
|
||||
<li><a name="watchdogregexp1WontReactivate">regexp1WontReactivate</a><br>
|
||||
Wenn ein Watchdog aktiv ist, wird ein zweites Ereignis das auf regexp1
|
||||
passt normalerweise den Timer zurücksetzen. Dieses Attribut wird
|
||||
das verhindern.</li>
|
||||
das verhindern.</li><br>
|
||||
|
||||
<li><a name="watchdogregexp2WillReactivate">regexp2WillReactivate</a><br>
|
||||
In der Voreinstellung wartet der Watchdog nach Empfang eines Events, der
|
||||
auf regexp2 matcht, wieder auf einem Event, was auf regexp1 matcht, um
|
||||
den Rückwärtszähler zu starten. Wenn dieses Attribut
|
||||
gesetzt ist (auf 1), dann wird nach dem Empfang des "regexp2" Events der
|
||||
Zähler ohne auf einem "regexp1" Event zu warten, von vorne
|
||||
gestartet. Falls regexp1 und regexp2 gleich sind, oder regexp2 ist .,
|
||||
dann ist dieses Verhalten die Voreinstellung.</li></br>
|
||||
|
||||
<li><a href="#execOnReactivate">execOnActivate</a>
|
||||
Falls gesetzt, wird der Wert des Attributes als FHEM Befehl
|
||||
ausgeführt, wenn ein regexp1 Ereignis den Watchdog
|
||||
aktiviert nachdem er ausgelöst wurde.</li>
|
||||
aktiviert nachdem er ausgelöst wurde.</li></br>
|
||||
|
||||
<li><a href="#autoRestart">autoRestart</a>
|
||||
Wenn dieses Attribut gesetzt ist, wird der Watchdog nach dem er
|
||||
|
Loading…
x
Reference in New Issue
Block a user