@ -47,7 +47,7 @@ sub LUXTRONIK2_doStatisticDelta ($$$$$) ;
sub LUXTRONIK2_doStatisticDeltaSingle ($$$$$$);
# Modul Version for remote debugging
my $modulVersion = "2014-04-29";
my $modulVersion = "2014-04-30";
#List of firmware versions that are known to be compatible with this modul
my $testedFirmware = "#V1.51#V1.54C#V1.60#V1.69#V1.70#";
@ -68,6 +68,7 @@ LUXTRONIK2_Initialize($)
"autoSynchClock:slider,10,5,300 ".
"boilerVolumn ".
"heatPumpElectricalPowerWatt:slider,1000,16000,100 ".
"heatPumpHotWaterElectricalPowerWatt:slider,1000,16000,100 ".
"heatRodElectricalPowerWatt:slider,1000,16000,100 ".
"compressor2ElectricalPowerWatt:slider,1000,16000,100 ".
"doStatistics:0,1 ".
@ -651,8 +652,7 @@ LUXTRONIK2_UpdateDone($)
return if($hash->{helper}{DISABLED});
my $cop = 0;
my $devicePower = AttrVal($hash->{NAME}, "heatPumpElectricalPowerWatt", 0);
Log3 $hash, 5, "$name: LUXTRONIK2_UpdateDone: $string";
#Define Status Messages
@ -716,7 +716,7 @@ LUXTRONIK2_UpdateDone($)
$counterRetry++;
my $doStatistic = AttrVal($name,"doStatistics",0);
if ($a[1]==0 ) {
readingsSingleUpdate($hash,"state","Error: ".$a[2],1);
$counterRetry = 0;
@ -836,9 +836,9 @@ LUXTRONIK2_UpdateDone($)
&& $a[11] == 1
&& $averageAmbientTemperature >= $thresholdHeatingLimit) {
if ($ambientTemperature>=10 ) {
$value = "Heizungsgrenze (Soll 15 C)";
$value = "Heizungsgrenze (Soll 15°C)";
} else {
$value = "Frostschutz (Soll 20 C)";
$value = "Frostschutz (Soll 20°C)";
}
} else {
$value = $heatingState{$a[46]};
@ -889,12 +889,12 @@ LUXTRONIK2_UpdateDone($)
# Operating hours (seconds->hours) and heat quantities
# LUXTRONIK2_storeReadings: $hash, $readingName, $value, $factor, $doStatistic, $tariffType
LUXTRONIK2_storeReadings $hash, "counterHours2ndHeatSource1", $a[32], 3600, $doStatistic, 2;
LUXTRONIK2_storeReadings $hash, "counterHours2ndHeatSource2", $a[38], 3600, $doStatistic, 2;
LUXTRONIK2_storeReadings $hash, "counterHours2ndHeatSource3", $a[39], 3600, $doStatistic, 2;
LUXTRONIK2_storeReadings $hash, "counterHours2ndHeatSource1", $a[32], 3600, $doStatistic, 4;
LUXTRONIK2_storeReadings $hash, "counterHours2ndHeatSource2", $a[38], 3600, $doStatistic, 4;
LUXTRONIK2_storeReadings $hash, "counterHours2ndHeatSource3", $a[39], 3600, $doStatistic, 4;
LUXTRONIK2_storeReadings $hash, "counterHoursHeatPump", $a[33], 3600, $doStatistic, 1;
LUXTRONIK2_storeReadings $hash, "counterHoursHeating", $a[34], 3600, $doStatistic, 1;
LUXTRONIK2_storeReadings $hash, "counterHoursHotWater", $a[35], 3600, $doStatistic, 1;
LUXTRONIK2_storeReadings $hash, "counterHoursHeating", $a[34], 3600, $doStatistic, 2;
LUXTRONIK2_storeReadings $hash, "counterHoursHotWater", $a[35], 3600, $doStatistic, 3;
LUXTRONIK2_storeReadings $hash, "counterHeatQHeating", $a[36], 10, ($a[19] !~ /no/ ? $doStatistic : 0), 0;
LUXTRONIK2_storeReadings $hash, "counterHeatQHotWater", $a[37], 10, ($a[19] !~ /no/ ? $doStatistic : 0), 0;
LUXTRONIK2_storeReadings $hash, "counterHeatQTotal", $a[36] + $a[37], 10, ($a[19] !~ /no/ ? $doStatistic : 0), 0;
@ -923,17 +923,22 @@ LUXTRONIK2_UpdateDone($)
$value = "unbekannt (".$a[31].")" unless $value;
readingsBulkUpdate($hash,"typeHeatpump",$value);
# Monitored operation: 5=Hot Water, 0=Heating
my $devicePower=0;
if ($a[3] == 5) {$devicePower = AttrVal($hash->{NAME}, "heatPumpHotWaterElectricalPowerWatt", 0);}
if ($devicePower == 0) {$devicePower = AttrVal($hash->{NAME}, "heatPumpElectricalPowerWatt", 0);}
#WM[kW] = delta_Temp [K] * Durchfluss [l/h] / ( 3.600 [kJ/kWh] / ( 4,179 [kJ/(kg*K)] (H2O Wärmekapazität bei 30 & 40°C) * 0,994 [kg/l] (H2O Dichte bei 35°C) )
my $thermalPower = 0;
# 0=Heizen, 5=Brauchwasser, 7=Abtauen, 16=Durchflussüberwachung
if ($a[3] =~ /^(0|5|16)$/ ) {
$thermalPower = abs($flowTemperature - $returnTemperature) * $a[19] / 866.65;
if ($devicePower > 0) {
$cop = $thermalPower *1000 / $devicePower;
readingsBulkUpdate( $hash, "COP", sprintf "%.2f", $cop);
}
}
readingsBulkUpdate( $hash, "thermalPower", sprintf "%.1f", $thermalPower);
if ($devicePower > 0) {
$cop = $thermalPower *1000 / $devicePower;
readingsBulkUpdate( $hash, "COP", sprintf "%.2f", $cop);
}
# Solar
if ($a[50] !~ /no/) {readingsBulkUpdate($hash, "solarCollectorTemperature", LUXTRONIK2_CalcTemp($a[50]));}
@ -946,7 +951,7 @@ LUXTRONIK2_UpdateDone($)
$value .= "$opStateHeatPump1<br>\n";
$value .= "$opStateHeatPump2<br>\n";
$value .= "$opStateHeatPump3<br>\n";
$value .= "Brauchwasser: $hotWaterTemperature &deg;C";
$value .= "Brauchwasser: $hotWaterTemperature&deg;C";
readingsBulkUpdate($hash,"floorplanHTML",$value);
}
# State update
@ -1208,8 +1213,12 @@ LUXTRONIK2_doStatisticThermalPower ($$$$$$$$)
$last[3] += $currAmbTemp;
$last[4] += $currHeatSourceIn;
$last[5]++;
my $devicePower = AttrVal($hash->{NAME}, "heatPumpElectricalPowerWatt", 0);
# Monitored operation: 5=Hot Water, 0=Heating
my $devicePower = 0;
if ($MonitoredOpState == 5) {$devicePower = AttrVal($hash->{NAME}, "heatPumpHotWaterElectricalPowerWatt", 0);}
if ($devicePower == 0) {$devicePower = AttrVal($hash->{NAME}, "heatPumpElectricalPowerWatt", 0);}
if ($last[0] != $MonitoredOpState && $currOpState == $MonitoredOpState ) {
# Save start values at the beginning of the monitored operation (5=Hot Water, 0=Heating)
$saveCurrent = 1;
@ -1594,8 +1603,11 @@ LUXTRONIK2_doStatisticDelta ($$$$$)
my $readingNamePower = $readingName;
$readingNamePower =~ s/Hours/Electricity/ ;
my $powerValue;
if ( $tariffType == 1 ) { $powerValue = AttrVal($name,"heatPumpElectricalPowerWatt",0); }
elsif ( $tariffType == 2 ) { $powerValue = AttrVal($name,"heatRodElectricalPowerWatt",0); }
if ( $tariffType == 1 || $tariffType == 2 ) { $powerValue = AttrVal($name,"heatPumpElectricalPowerWatt",0);
} elsif ( $tariffType == 3 ) {
$powerValue = AttrVal($name,"heatPumpHotWaterElectricalPowerWatt",0);
if ($powerValue == 0) { $powerValue = AttrVal($name,"heatPumpElectricalPowerWatt",0); }
} elsif ( $tariffType == 4 ) { $powerValue = AttrVal($name,"heatRodElectricalPowerWatt",0); }
if ($powerValue > 0) {
foreach (1,2,3,4,5,6,7,8,9) {
if ( $previousTariff == $_ ) {
@ -1660,7 +1672,7 @@ LUXTRONIK2_doStatisticDeltaSingle ($$$$$$)
# If change of day, change daily statistic
if ($periodSwitch >= 1){
$last[1] = sprintf("%.0f",$curr[1] / $factor);
$last[1] = sprintf("%.1f",$curr[1] / $factor);
$curr[1] = 0;
if ($showDate == 5) {
$last[7] = $curr[7];
@ -1677,7 +1689,7 @@ LUXTRONIK2_doStatisticDeltaSingle ($$$$$$)
readingsBulkUpdate($hash,".".$readingName,$result);
# Store visible statistic readings (delta values)
$result = "Day: ".sprintf("%.0f",$curr[1]/$factor);
$result = "Day: ".sprintf("%.1f",$curr[1]/$factor);
$result .= " Month: ".sprintf("%.0f",$curr[3]/$factor);
$result .= " Year: ".sprintf("%.0f",$curr[5]/$factor);
if ( $showDate >=2 ) { $result .= " (since: $curr[7] )"; }
@ -1789,6 +1801,9 @@ LUXTRONIK2_doStatisticDeltaSingle ($$$$$$)
<li><code>heatPumpElectricalPowerWatt</code><br>
Electrical power of the heat pump to calculated coefficency factor and estimate electrical consumption
</li><br>
<li><code>heatPumpHotWaterElectricalPowerWatt</code><br>
Electrical power of the heat pump during hot water preparation to calculated coefficency factor and estimate electrical consumption
</li><br>
<li><code>heatHeatRodElectricalPowerWatt</code><br>
Electrical power of the heat rods (2nd heat source) to estimate electrical consumption
</li><br>
@ -1915,6 +1930,10 @@ LUXTRONIK2_doStatisticDeltaSingle ($$$$$$)
Betriebsleistung der W&auml;remepumpe zur Berechung der Arbeitszahl (erzeugte Wärme pro elektrische Energieeinheit)
und Absch&auml;tzung des elektrischen Verbrauches
</li><br>
<li><code>heatPumpHotWaterElectricalPowerWatt</code><br>
Betriebsleistung der W&auml;remepumpe während der Warmwasserbereitung zur Berechung der Arbeitszahl (erzeugte Wärme pro elektrische Energieeinheit)
und Absch&auml;tzung des elektrischen Verbrauches
</li><br>
<li><code>heatHeatRodElectricalPowerWatt</code><br>
Betriebsleistung der Heizstäbe zur Absch&auml;tzung des elektrischen Verbrauches
</li><br>