94_PWM.pm : add attribute disable and fix OverallHeatingSwitch
git-svn-id: https://svn.fhem.de/fhem/trunk@14830 2b470e98-0d58-463d-a4d8-8e2adae1ed80
This commit is contained in:
parent
82268328fc
commit
ad0891b6c4
@ -23,6 +23,8 @@
|
|||||||
# 16.11.16 GA add new attribute overallHeatingSwitchRef for threshold based configuration
|
# 16.11.16 GA add new attribute overallHeatingSwitchRef for threshold based configuration
|
||||||
# 17.11.16 GA add internals for configuration parameters: p_interval, p_cycletime, p_minOnOffTime,
|
# 17.11.16 GA add internals for configuration parameters: p_interval, p_cycletime, p_minOnOffTime,
|
||||||
# p_maxPulse, p_roomsMinOnOffThreshold and p_overallHeatingSwitch
|
# p_maxPulse, p_roomsMinOnOffThreshold and p_overallHeatingSwitch
|
||||||
|
# 01.08.17 GA add attribute disable to stop calculations of PWM
|
||||||
|
# 01.08.17 GA fix OverallHeatingSwitch (without threshold) now independent from ValveProtection
|
||||||
|
|
||||||
##############################################
|
##############################################
|
||||||
# $Id$
|
# $Id$
|
||||||
@ -76,7 +78,7 @@ PWM_Initialize($)
|
|||||||
$hash->{UndefFn} = "PWM_Undef";
|
$hash->{UndefFn} = "PWM_Undef";
|
||||||
$hash->{AttrFn} = "PWM_Attr";
|
$hash->{AttrFn} = "PWM_Attr";
|
||||||
|
|
||||||
$hash->{AttrList} = "event-on-change-reading event-min-interval valveProtectIdlePeriod overallHeatingSwitchRef:pulseMax,pulseSum,pulseAvg,pulseAvg2,pulseAvg3,avgPulseRoomsOn";
|
$hash->{AttrList} = "disable:1,0 event-on-change-reading event-min-interval valveProtectIdlePeriod overallHeatingSwitchRef:pulseMax,pulseSum,pulseAvg,pulseAvg2,pulseAvg3,avgPulseRoomsOn";
|
||||||
#$hash->{GetList} = "status timers";
|
#$hash->{GetList} = "status timers";
|
||||||
|
|
||||||
}
|
}
|
||||||
@ -106,6 +108,13 @@ PWM_Calculate($)
|
|||||||
InternalTimer(gettimeofday() + $hash->{INTERVAL}, "PWM_Calculate", $hash, 0);
|
InternalTimer(gettimeofday() + $hash->{INTERVAL}, "PWM_Calculate", $hash, 0);
|
||||||
}
|
}
|
||||||
|
|
||||||
|
if (defined($attr{$name}{disable}) and $attr{$name}{disable} == 1) {
|
||||||
|
Log3 ($hash, 3, "PWM_Calculate $name");
|
||||||
|
$hash->{STATE} = "disabled";
|
||||||
|
readingsSingleUpdate ($hash, "lastrun", "disabled", 0);
|
||||||
|
return;
|
||||||
|
}
|
||||||
|
|
||||||
Log3 ($hash, 3, "PWM_Calculate $name");
|
Log3 ($hash, 3, "PWM_Calculate $name");
|
||||||
|
|
||||||
readingsBeginUpdate ($hash);
|
readingsBeginUpdate ($hash);
|
||||||
@ -123,8 +132,6 @@ PWM_Calculate($)
|
|||||||
foreach my $d (sort keys %defs) {
|
foreach my $d (sort keys %defs) {
|
||||||
if ( (defined ($defs{$d}{TYPE})) && $defs{$d}{TYPE} eq "PWMR" ) { # all PWMR objects
|
if ( (defined ($defs{$d}{TYPE})) && $defs{$d}{TYPE} eq "PWMR" ) { # all PWMR objects
|
||||||
if (!defined ($attr{$d}{disable}) or $attr{$d}{disable} == 0) { # not disabled
|
if (!defined ($attr{$d}{disable}) or $attr{$d}{disable} == 0) { # not disabled
|
||||||
#if ($hash->{NAME} eq $defs{$d}{IODev}) { # referencing to this fb
|
|
||||||
#if ($hash->{NAME} eq $defs{$d}{IODev}{NAME}) { # referencing to this fb
|
|
||||||
if ($hash->{NAME} eq $defs{$d}{IODev}->{NAME}) { # referencing to this fb
|
if ($hash->{NAME} eq $defs{$d}{IODev}->{NAME}) { # referencing to this fb
|
||||||
|
|
||||||
Log3 ($hash, 4, "PWM_Calculate calc $name, room $d");
|
Log3 ($hash, 4, "PWM_Calculate calc $name, room $d");
|
||||||
@ -406,6 +413,7 @@ PWM_Calculate($)
|
|||||||
#
|
#
|
||||||
|
|
||||||
my $cntRoomsOn = 0;
|
my $cntRoomsOn = 0;
|
||||||
|
my $cntRoomsOnVP = 0;
|
||||||
my $cntRoomsOff = 0;
|
my $cntRoomsOff = 0;
|
||||||
my $pulseRoomsOn = 0;
|
my $pulseRoomsOn = 0;
|
||||||
my $pulseRoomsOff = 0;
|
my $pulseRoomsOff = 0;
|
||||||
@ -456,6 +464,7 @@ PWM_Calculate($)
|
|||||||
|
|
||||||
PWMR_SetRoom ($defs{$roomVP}, "on");
|
PWMR_SetRoom ($defs{$roomVP}, "on");
|
||||||
$cntRoomsOn++;
|
$cntRoomsOn++;
|
||||||
|
$cntRoomsOnVP++;
|
||||||
$pulseRoomsOn += $RoomsPulses{$roomVP};
|
$pulseRoomsOn += $RoomsPulses{$roomVP};
|
||||||
|
|
||||||
} else {
|
} else {
|
||||||
@ -525,7 +534,7 @@ PWM_Calculate($)
|
|||||||
} else {
|
} else {
|
||||||
|
|
||||||
# room based
|
# room based
|
||||||
$newstateOHS = ($cntRoomsOn > 0) ? "on" : "off";
|
$newstateOHS = (($cntRoomsOn - $cntRoomsOnVP) > 0) ? "on" : "off";
|
||||||
|
|
||||||
}
|
}
|
||||||
|
|
||||||
@ -1168,6 +1177,9 @@ PWM_Attr(@)
|
|||||||
|
|
||||||
<b>Attributes</b>
|
<b>Attributes</b>
|
||||||
<ul>
|
<ul>
|
||||||
|
<li>disable<br>
|
||||||
|
Set to 1 will disable all calculations and STATE will be set to "disabled".<br>
|
||||||
|
</li><br>
|
||||||
<li>valveProtectIdlePeriod<br>
|
<li>valveProtectIdlePeriod<br>
|
||||||
Protect Valve by switching on actor for 300 seconds.<br>
|
Protect Valve by switching on actor for 300 seconds.<br>
|
||||||
After <i>valveProtectIdlePeriod</i> number of days without switching the valve the actor is set to "on" for 300 seconds.
|
After <i>valveProtectIdlePeriod</i> number of days without switching the valve the actor is set to "on" for 300 seconds.
|
||||||
|