@ -425,8 +425,6 @@ LUXTRONIK2_DoUpdate($)
|
||||
|
||||
Log3 $name, 5, "$name: $count_set_parameter set values received";
|
||||
|
||||
goto SKIP_VISIBILITY_READING;
|
||||
|
||||
############################
|
||||
#Fetch Visibility Attributes (FVA)
|
||||
############################
|
||||
@ -479,8 +477,6 @@ goto SKIP_VISIBILITY_READING;
|
||||
|
||||
####################################
|
||||
|
||||
SKIP_VISIBILITY_READING:
|
||||
|
||||
Log3 $name, 5, "$name: Closing connection to host $host";
|
||||
$socket->close();
|
||||
|
||||
@ -524,7 +520,7 @@ SKIP_VISIBILITY_READING:
|
||||
# 17 - returnTemperatureTarget
|
||||
$return_str .= "|".$heatpump_values[12];
|
||||
# 18 - returnTemperatureExtern
|
||||
$return_str .= "|".$heatpump_values[13];
|
||||
$return_str .= "|".($heatpump_visibility[24]==1 ? $heatpump_values[13] : "no");
|
||||
# 19 - flowRate
|
||||
$return_str .= "|".$heatpump_values[155];
|
||||
# 20 - firmware
|
||||
@ -556,21 +552,21 @@ SKIP_VISIBILITY_READING:
|
||||
# 31 - typeHeatpump
|
||||
$return_str .= "|".$heatpump_values[78];
|
||||
# 32 - counterHours2ndHeatSource1
|
||||
$return_str .= "|".$heatpump_values[60];
|
||||
$return_str .= "|". ($heatpump_visibility[84]==1 ? $heatpump_values[60] : "no");
|
||||
# 33 - counterHoursHeatpump
|
||||
$return_str .= "|".$heatpump_values[63];
|
||||
$return_str .= "|". ($heatpump_visibility[87]==1 ? $heatpump_values[63] : "no");
|
||||
# 34 - counterHoursHeating
|
||||
$return_str .= "|".$heatpump_values[64];
|
||||
$return_str .= "|". ($heatpump_visibility[195]==1 ? $heatpump_values[64] : "no");
|
||||
# 35 - counterHoursHotWater
|
||||
$return_str .= "|".$heatpump_values[65];
|
||||
$return_str .= "|". ($heatpump_visibility[196]==1 ? $heatpump_values[65] : "no");
|
||||
# 36 - counterHeatQHeating
|
||||
$return_str .= "|".$heatpump_values[151];
|
||||
$return_str .= "|" . $heatpump_values[151];
|
||||
# 37 - counterHeatQHeating
|
||||
$return_str .= "|".$heatpump_values[152];
|
||||
$return_str .= "|". $heatpump_values[152];
|
||||
# 38 - counterHours2ndHeatSource2
|
||||
$return_str .= "|".$heatpump_values[61];
|
||||
$return_str .= "|". ($heatpump_visibility[85]==1 ? $heatpump_values[61] : "no");
|
||||
# 39 - counterHours2ndHeatSource3
|
||||
$return_str .= "|".$heatpump_values[62];
|
||||
$return_str .= "|". ($heatpump_visibility[86]==1 ? $heatpump_values[62] : "no");
|
||||
# 40 - opStateHeatPump2
|
||||
$return_str .= "|".$heatpump_values[118];
|
||||
# 41 - opStateHeatPump2Duration
|
||||
@ -591,6 +587,12 @@ SKIP_VISIBILITY_READING:
|
||||
$return_str .= "|".$heatpump_parameters[111];
|
||||
# 49 - hotWaterTemperatureHysterese
|
||||
$return_str .= "|".$heatpump_parameters[74];
|
||||
# 50 - solarCollectorTemperature
|
||||
$return_str .= "|". ($heatpump_visibility[36]==1 ? $heatpump_values[26] : "no");
|
||||
# 51 - solarBufferTemperature
|
||||
$return_str .= "|". ($heatpump_visibility[37]==1 ? $heatpump_values[27] : "no");
|
||||
# 52 - counterHoursSolar
|
||||
$return_str .= "|". ($heatpump_visibility[248]==1 ? $heatpump_values[161] : "no");
|
||||
|
||||
return $return_str;
|
||||
}
|
||||
@ -720,7 +722,7 @@ LUXTRONIK2_UpdateDone($)
|
||||
if ( exists( $hash->{READINGS}{statBoilerGradientCoolDownMin} ) ) {
|
||||
my @new = split / /, $value;
|
||||
my @old = split / /, $hash->{READINGS}{statBoilerGradientCoolDownMin};
|
||||
if ($new[5]>6 && $new[0]>$old[0] && $new[0] < 0) {
|
||||
if ($new[5]>6 && $new[1]>$old[1] && $new[1] < 0) {
|
||||
readingsBulkUpdate($hash,"statBoilerGradientCoolDownMin",$value);
|
||||
Log3 $name,3,"$name: statBoilerGradientCoolDownMin set to $value";
|
||||
}
|
||||
@ -821,7 +823,7 @@ LUXTRONIK2_UpdateDone($)
|
||||
readingsBulkUpdate( $hash, "flowTemperature", $flowTemperature);
|
||||
readingsBulkUpdate( $hash, "returnTemperature", $returnTemperature);
|
||||
readingsBulkUpdate( $hash, "returnTemperatureTarget",LUXTRONIK2_CalcTemp($a[17]));
|
||||
readingsBulkUpdate( $hash, "returnTemperatureExtern",LUXTRONIK2_CalcTemp($a[18]));
|
||||
if ($a[18] !~ /no/) {readingsBulkUpdate( $hash, "returnTemperatureExtern",LUXTRONIK2_CalcTemp($a[18]))};
|
||||
readingsBulkUpdate( $hash, "flowRate",$a[19]);
|
||||
readingsBulkUpdate( $hash, "heatSourceIN",LUXTRONIK2_CalcTemp($a[23]));
|
||||
readingsBulkUpdate( $hash, "heatSourceOUT",LUXTRONIK2_CalcTemp($a[24]));
|
||||
@ -852,19 +854,24 @@ LUXTRONIK2_UpdateDone($)
|
||||
readingsBulkUpdate($hash,"typeHeatpump",$value);
|
||||
|
||||
# Operating hours (seconds->hours) and heat quantities, write/create readings only if >0
|
||||
if ($a[32]>0) {readingsBulkUpdate($hash,"counterHours2ndHeatSource1",floor($a[32]/360+0.5)/10);}
|
||||
if ($a[38]>0) {readingsBulkUpdate($hash,"counterHours2ndHeatSource2",floor($a[38]/360+0.5)/10);}
|
||||
if ($a[39]>0) {readingsBulkUpdate($hash,"counterHours2ndHeatSource3",floor($a[39]/360+0.5)/10);}
|
||||
if ($a[33]>0) {readingsBulkUpdate($hash,"counterHoursHeatPump",floor($a[33]/360+0.5)/10);}
|
||||
if ($a[34]>0) {readingsBulkUpdate($hash,"counterHoursHeating",floor($a[34]/360+0.5)/10);}
|
||||
if ($a[35]>0) {readingsBulkUpdate($hash,"counterHoursHotWater",floor($a[35]/360+0.5)/10);}
|
||||
if ($a[36]>0) {readingsBulkUpdate($hash,"counterHeatQHeating",$a[36]/10);}
|
||||
if ($a[37]>0) {readingsBulkUpdate($hash,"counterHeatQHotWater",$a[37]/10);}
|
||||
if ($a[36]+$a[37]>0) {readingsBulkUpdate($hash,"counterHeatQTotal",($a[36]+$a[37])/10);}
|
||||
if ($a[32] !~ /no/) {readingsBulkUpdate($hash,"counterHours2ndHeatSource1", sprintf("%.1f", $a[32]/3600));}
|
||||
if ($a[38] !~ /no/) {readingsBulkUpdate($hash,"counterHours2ndHeatSource2", sprintf("%.1f", $a[38]/3600));}
|
||||
if ($a[39] !~ /no/) {readingsBulkUpdate($hash,"counterHours2ndHeatSource3", sprintf("%.1f", $a[39]/3600));}
|
||||
if ($a[33] !~ /no/) {readingsBulkUpdate($hash,"counterHoursHeatPump", sprintf("%.1f", $a[33]/3600));}
|
||||
if ($a[34] !~ /no/) {readingsBulkUpdate($hash,"counterHoursHeating", sprintf("%.1f", $a[34]/3600));}
|
||||
if ($a[35] !~ /no/) {readingsBulkUpdate($hash,"counterHoursHotWater", sprintf("%.1f", $a[35]/3600));}
|
||||
if ($a[36] > 0) {readingsBulkUpdate($hash,"counterHeatQHeating", $a[36]/10);}
|
||||
if ($a[37] > 0) {readingsBulkUpdate($hash,"counterHeatQHotWater" ,$a[37]/10);}
|
||||
if ($a[36] > 0 && $a[37] > 0) {readingsBulkUpdate($hash,"counterHeatQTotal",($a[36]+$a[37])/10);}
|
||||
#WM[kW] = delta_Temp [K] * Durchfluss [l/h] / ( 3.600 [kJ/kWh] / ( 4,179 [kJ/(kg*K)] (H2O Wärmekapazität bei 30 & 40°C) * 0,994 [kg/l] (H2O Dichte bei 35°C) )
|
||||
$value = ($flowTemperature-$returnTemperature) * $a[19] / 866.65;
|
||||
readingsBulkUpdate( $hash, "currentThermalOutput", sprintf("%.1f", $value));
|
||||
|
||||
# Solar
|
||||
if ($a[50] !~ /no/) {readingsBulkUpdate($hash, "solarCollectorTemperature", LUXTRONIK2_CalcTemp($a[50]));}
|
||||
if ($a[51] !~ /no/) {readingsBulkUpdate($hash, "solarBufferTemperature", LUXTRONIK2_CalcTemp($a[51]));}
|
||||
if ($a[52] !~ /no/) {readingsBulkUpdate($hash, "counterHoursSolar", sprintf("%.1f", $a[52]/3600));}
|
||||
|
||||
# HTML for floorplan
|
||||
if(AttrVal($name, "statusHTML", "none") ne "none") {
|
||||
$value = "<div class=fp_" . $a[0] . "_title>" . $a[0] . "</div>";
|
||||
@ -1277,7 +1284,7 @@ LUXTRONIK2_doStatisticBoilerCoolDown ($$$$$$)
|
||||
<a name="LUXTRONIK2"></a>
|
||||
<h3>LUXTRONIK2</h3>
|
||||
<ul>
|
||||
Luxtronik 2.0 is a heating controller used in Alpha Innotec and Siemens Novelan (WPR NET) heat pumps.
|
||||
Luxtronik 2.0 is a heating controller used in <a href="http://www.alpha-innotec.de">Alpha Innotec</a> and Siemens Novelan (WPR NET) heat pumps.
|
||||
<br>
|
||||
It has a built-in ethernet port, so it can be directly integrated into a local area network (LAN).
|
||||
<br>
|
||||
@ -1354,7 +1361,7 @@ LUXTRONIK2_doStatisticBoilerCoolDown ($$$$$$)
|
||||
<a name="LUXTRONIK2"></a>
|
||||
<h3>LUXTRONIK2</h3>
|
||||
<ul>
|
||||
Die Luxtronik 2.0 ist eine Heizungssteuerung, welche in Wärmepumpen von Alpha Innotec und Siemens Novelan (WPR NET) verbaut ist.<br>
|
||||
Die Luxtronik 2.0 ist eine Heizungssteuerung, welche in Wärmepumpen von <a href="http://www.alpha-innotec.de">Alpha Innotec</a> und Siemens Novelan (WPR NET) verbaut ist.<br>
|
||||
Sie besitzt einen Ethernet Anschluss, so dass sie direkt in lokale Netzwerke (LAN) integriert werden kann.<br>
|
||||
<i>Das Modul wurde bisher mit folgender Steuerungs-Firmware getestet: V1.54C, V1.60, V1.69.</i>
|
||||
<br>
|
||||
|
@ -697,7 +697,7 @@ JSONMETER_UpdateAborted($)
|
||||
<ul>
|
||||
Dieses Modul liest Daten von Messgeräten (z.B. Stromzähler, Gaszähler oder Wärmezähler, so genannte Smartmeter),
|
||||
<br>
|
||||
welche OBIS kompatible Daten im JSON-Format auf einem Webserver oder auf dem FHEM-Dateisystem zur Verfügung stellen.
|
||||
welche <a href="http://de.wikipedia.org/wiki/OBIS-Kennzahlen">OBIS</a> kompatible Daten im JSON-Format auf einem Webserver oder auf dem FHEM-Dateisystem zur Verfügung stellen.
|
||||
<br>
|
||||
|
||||
<br>
|
||||
@ -707,10 +707,10 @@ JSONMETER_UpdateAborted($)
|
||||
<code>define <name> JSONMETER <Gerätetyp> [<IP-Adresse>] [Abfrageinterval]</code>
|
||||
<br>
|
||||
Beispiel: <code>define Stromzaehler JSONMETER ITF 192.168.178.20 300</code>
|
||||
<br>
|
||||
<br>
|
||||
<li><code>[Abfrageinterval]</code>
|
||||
<br>
|
||||
Standardmässig 300 Sekunden. Der kleinste mögliche Wert ist 30.
|
||||
Optional. Standardmässig 300 Sekunden. Der kleinste mögliche Wert ist 30.
|
||||
<br>
|
||||
Bei 0 kann die Geräteabfrage nur manuell gestartet werden.
|
||||
</li><br>
|
||||
@ -721,7 +721,7 @@ JSONMETER_UpdateAborted($)
|
||||
Mit dem Attribute 'pathString' können Login Information an den URL-Pfad von vordefinierten Geräte angehangen werden.
|
||||
<ul>
|
||||
<li><b>ITF</b> - Eintarifzähler von N-ENERGY Netz GmbH (<a href="http://www.itf-froeschl.de">ITF Fröschl</a>)</li>
|
||||
<li><b>EFR</b> - Stromzähler von EON, N-ENERGY, EnBW
|
||||
<li><b>EFR</b> - <a href="http://www.efr.de">EFR</a> Smart Grid Hub für Stromzähler von EON, N-ENERGY, EnBW
|
||||
<br>
|
||||
Die Login-Information wird über das Attribute 'pathstring' angegeben.
|
||||
<br>
|
||||
|
Loading…
Reference in New Issue
Block a user