mirror of
https://github.com/fhem/fhem-mirror.git
synced 2025-01-31 00:36:25 +00:00
76_SolarForecast: contrib 1.37.7
git-svn-id: https://svn.fhem.de/fhem/trunk@29362 2b470e98-0d58-463d-a4d8-8e2adae1ed80
This commit is contained in:
parent
012ea2c451
commit
9354ee4319
@ -156,6 +156,11 @@ BEGIN {
|
||||
|
||||
# Versions History intern
|
||||
my %vNotesIntern = (
|
||||
"1.37.7" => "25.11.2024 Attr flowGraphicControl: key shift changed to shiftx, new key shifty ".
|
||||
"change: 'trackFlex' && \$wcc >= 70 to \$wcc >= 80 ",
|
||||
"1.37.6" => "01.11.2024 minor code change, Attr setupBatteryDev: the key 'cap' is mandatory now ",
|
||||
"1.37.5" => "31.10.2024 attr setupInverterDevXX: new key 'limit', the key 'capacity' is now mandatory ".
|
||||
"Attr affect70percentRule, ctrlAutoRefresh, ctrlAutoRefreshFW deleted ",
|
||||
"1.37.4" => "29.10.2024 both attr graphicStartHtml, graphicEndHtml removed, fix flowGraphic when device name contains '.' ",
|
||||
"1.37.3" => "25.10.2024 _flowGraphic: grid, dummy and battery displacement by kask ".
|
||||
"Attr flowGraphicControl: new key h2consumerdist, animate=1 is default now ",
|
||||
@ -493,10 +498,10 @@ my @rconfigs = qw( pvCorrectionFactor_Auto
|
||||
energyH4Trigger
|
||||
);
|
||||
# Anlagenkonfiguration: maßgebliche Attribute
|
||||
my @aconfigs = qw( affect70percentRule affectBatteryPreferredCharge affectConsForecastIdentWeekdays
|
||||
my @aconfigs = qw( affectBatteryPreferredCharge affectConsForecastIdentWeekdays
|
||||
affectConsForecastInPlanning affectSolCastPercentile
|
||||
consumerLegend consumerAdviceIcon consumerLink
|
||||
ctrlAIdataStorageDuration ctrlAutoRefresh ctrlAutoRefreshFW ctrlBackupFilesKeep
|
||||
ctrlAIdataStorageDuration ctrlBackupFilesKeep
|
||||
ctrlBatSocManagement ctrlConsRecommendReadings ctrlGenPVdeviation ctrlInterval
|
||||
ctrlLanguage ctrlNextDayForecastReadings ctrlShowLink ctrlSolCastAPImaxReq
|
||||
ctrlSolCastAPIoptimizeReq ctrlStatisticReadings ctrlUserExitFn
|
||||
@ -1164,7 +1169,6 @@ my %hfspvh = (
|
||||
sub Initialize {
|
||||
my $hash = shift;
|
||||
|
||||
my $fwd = join ",", devspec2array("TYPE=FHEMWEB:FILTER=STATE=Initialized");
|
||||
my $hod = join ",", map { sprintf "%02d", $_} (1..24);
|
||||
my $srd = join ",", sort keys (%hcsr);
|
||||
my $gbc = 'pvReal,pvForecast,consumption,consumptionForecast,gridconsumption,energycosts,gridfeedin,feedincome';
|
||||
@ -1202,8 +1206,7 @@ sub Initialize {
|
||||
$hash->{AttrFn} = \&Attr;
|
||||
$hash->{NotifyFn} = \&Notify;
|
||||
$hash->{ReadyFn} = \&runTask;
|
||||
$hash->{AttrList} = "affect70percentRule:1,dynamic,0 ".
|
||||
"affectBatteryPreferredCharge:slider,0,1,100 ".
|
||||
$hash->{AttrList} = "affectBatteryPreferredCharge:slider,0,1,100 ".
|
||||
"affectConsForecastIdentWeekdays:1,0 ".
|
||||
"affectConsForecastInPlanning:1,0 ".
|
||||
"affectConsForecastLastDays:slider,1,1,31 ".
|
||||
@ -1213,12 +1216,10 @@ sub Initialize {
|
||||
"consumerLink:0,1 ".
|
||||
"ctrlAIdataStorageDuration ".
|
||||
"ctrlAIshiftTrainStart:slider,1,1,23 ".
|
||||
"ctrlAutoRefresh:selectnumbers,120,0.2,1800,0,log10 ".
|
||||
"ctrlAutoRefreshFW:$fwd ".
|
||||
"ctrlBackupFilesKeep ".
|
||||
"ctrlBatSocManagement:textField-long ".
|
||||
"ctrlConsRecommendReadings:multiple-strict,$allcs ".
|
||||
"ctrlDebug:multiple-strict,$dm,#14 ".
|
||||
"ctrlDebug:multiple-strict,$dm,#10 ".
|
||||
"ctrlAreaFactorUsage:fix,trackFull,trackShared,trackFlex ".
|
||||
"ctrlGenPVdeviation:daily,continuously ".
|
||||
"ctrlInterval ".
|
||||
@ -1282,6 +1283,8 @@ sub Initialize {
|
||||
my $av = 'obsolete#-#use#attr#flowGraphicControl#instead';
|
||||
$hash->{AttrList} .= " flowGraphicCss:$av flowGraphicSize:$av flowGraphicAnimate:$av flowGraphicConsumerDistance:$av flowGraphicShowConsumer:$av flowGraphicShowConsumerDummy:$av flowGraphicShowConsumerPower:$av flowGraphicShowConsumerRemainTime:$av flowGraphicShift:$av ";
|
||||
|
||||
my $av1 = "obsolete#-#the#attribute#will#be#deleted#soon";
|
||||
$hash->{AttrList} .= " affect70percentRule:$av1 ctrlAutoRefresh:$av1 ctrlAutoRefreshFW:$av1 ";
|
||||
##########################################################################################################################
|
||||
|
||||
$hash->{FW_hideDisplayName} = 1; # Forum 88667
|
||||
@ -3451,7 +3454,7 @@ sub __getDWDSolarData {
|
||||
$af = 1.00 if(!isNumeric($af));
|
||||
$sdr = 0.75 if(!isNumeric($sdr));
|
||||
|
||||
if ($cafd eq 'trackShared'|| ($cafd eq 'trackFlex' && $wcc >= 70)) { # Direktstrahlung + Diffusstrahlung
|
||||
if ($cafd eq 'trackShared'|| ($cafd eq 'trackFlex' && $wcc >= 80)) { # Direktstrahlung + Diffusstrahlung
|
||||
my $dirrad = $rad * $sdr; # Anteil Direktstrahlung an Globalstrahlung
|
||||
my $difrad = $rad - $dirrad; # Anteil Diffusstrahlung an Globalstrahlung
|
||||
|
||||
@ -5329,13 +5332,16 @@ sub Attr {
|
||||
return qq{The attribute '$aName' is obsolete and replaced by 'flowGraphicControl'.};
|
||||
}
|
||||
}
|
||||
# 29.10.2024
|
||||
if ($cmd eq 'set' && $aName =~ /^graphicStartHtml|graphicEndHtml$/) {
|
||||
# 31.10.2024
|
||||
if ($cmd eq 'set' && $aName =~ /^graphicStartHtml|affect70percentRule|graphicEndHtml|ctrlAutoRefresh|ctrlAutoRefreshFW$/) {
|
||||
if (!$init_done) {
|
||||
my $msg = "The attribute $aName has been removed and is no longer valid.";
|
||||
Log3 ($name, 1, "$name - $msg");
|
||||
return qq{Device "$name" -> $msg};
|
||||
}
|
||||
else {
|
||||
return qq{The attribute '$aName' is obsolete.};
|
||||
}
|
||||
}
|
||||
######################################################################################################################
|
||||
|
||||
@ -5348,18 +5354,13 @@ sub Attr {
|
||||
singleUpdateState ( {hash => $hash, state => $val, evt => 1} );
|
||||
}
|
||||
|
||||
if ($aName eq 'ctrlAutoRefresh') {
|
||||
delete $hash->{HELPER}{AREFRESH};
|
||||
delete $hash->{AUTOREFRESH};
|
||||
}
|
||||
|
||||
if ($aName eq 'ctrlNextDayForecastReadings') {
|
||||
deleteReadingspec ($hash, "Tomorrow_Hour.*");
|
||||
}
|
||||
|
||||
if ($aName eq 'ctrlBatSocManagement' && $init_done) {
|
||||
if ($cmd eq 'set') {
|
||||
return qq{Define the key "cap" with "attr $name setupBatteryDev" before this attribute in the correct form.}
|
||||
return qq{Define the key 'cap' with "attr $name setupBatteryDev" before this attribute in the correct form.}
|
||||
if(!CurrentVal($hash, 'batinstcap', 0)); # https://forum.fhem.de/index.php?msg=1310930
|
||||
|
||||
my ($lowSoc, $upSoc, $maxsoc, $careCycle) = __parseAttrBatSoc ($name, $aVal);
|
||||
@ -5656,7 +5657,8 @@ sub _attrflowGraphicControl { ## no critic "not used"
|
||||
for my $av ( qw( animate
|
||||
consumerdist
|
||||
h2consumerdist
|
||||
shift
|
||||
shiftx
|
||||
shifty
|
||||
showconsumer
|
||||
showconsumerremaintime
|
||||
size
|
||||
@ -5676,7 +5678,8 @@ sub _attrflowGraphicControl { ## no critic "not used"
|
||||
animate => '0|1',
|
||||
consumerdist => '[89]\d{1}|[1234]\d{2}|500',
|
||||
h2consumerdist => '\d{1,3}',
|
||||
shift => '-?[0-7]\d{0,1}|-?80',
|
||||
shiftx => '-?[0-7]\d{0,1}|-?80',
|
||||
shifty => '\d+',
|
||||
size => '\d+',
|
||||
showconsumer => '0|1',
|
||||
showconsumerdummy => '0|1',
|
||||
@ -5837,13 +5840,19 @@ sub _attrInverterDev { ## no critic "not used"
|
||||
return qq{Set the first Inverter device with attribute 'setupInverterDev01'};
|
||||
}
|
||||
|
||||
if (!$h->{pv} || !$h->{etotal}) {
|
||||
return qq{The syntax of '$aName' is not valid. Please consider the commandref.};
|
||||
if (!$h->{pv} || !$h->{etotal} || !$h->{capacity}) {
|
||||
return qq{One or more of the keys 'pv, etotal, capacity' are missing. Please consider the commandref.};
|
||||
}
|
||||
|
||||
if ($h->{capacity} && !isNumeric($h->{capacity})) {
|
||||
return qq{The syntax of key 'capacity' is not valid. Please consider the commandref.};
|
||||
if (!isNumeric($h->{capacity})) {
|
||||
return qq{The value of key 'capacity' must be numeric. Please consider the commandref.};
|
||||
}
|
||||
|
||||
if ($h->{limit}) {
|
||||
if (!isNumeric($h->{limit}) || $h->{limit} < 0 || $h->{limit} > 100) {
|
||||
return qq{The value of key 'limit' is not valid. Please consider the commandref.};
|
||||
}
|
||||
}
|
||||
|
||||
if ($h->{feed} && $h->{feed} !~ /^grid|bat$/xs) {
|
||||
return qq{The value of key 'feed' is not valid. Please consider the commandref.};
|
||||
@ -5860,6 +5869,7 @@ sub _attrInverterDev { ## no critic "not used"
|
||||
$data{$type}{$name}{circular}{99}{attrInvChangedTs} = int time;
|
||||
|
||||
delete $data{$type}{$name}{inverters}{$in}{invertercap};
|
||||
delete $data{$type}{$name}{inverters}{$in}{ilimit};
|
||||
delete $data{$type}{$name}{inverters}{$in}{iicon};
|
||||
delete $data{$type}{$name}{inverters}{$in}{istrings};
|
||||
delete $data{$type}{$name}{inverters}{$in}{ifeed};
|
||||
@ -6027,8 +6037,8 @@ sub _attrBatteryDev { ## no critic "not used"
|
||||
my ($err, $badev, $h) = isDeviceValid ( { name => $name, obj => $aVal, method => 'string' } );
|
||||
return $err if($err);
|
||||
|
||||
if (!$h->{pin} || !$h->{pout}) {
|
||||
return qq{The keys 'pin' and/or 'pout' are not set. Please note the command reference.};
|
||||
if (!$h->{pin} || !$h->{pout} || !$h->{cap}) {
|
||||
return qq{One or more of the keys 'pin, pout, cap' are missing. Please note the command reference.};
|
||||
}
|
||||
|
||||
if (($h->{pin} !~ /-/xs && $h->{pin} !~ /:/xs) ||
|
||||
@ -7023,6 +7033,7 @@ sub centralTask {
|
||||
_transferMeterValues ($centpars); # Energy Meter auswerten
|
||||
_transferBatteryValues ($centpars); # Batteriewerte einsammeln
|
||||
_batSocTarget ($centpars); # Batterie Optimum Ziel SOC berechnen
|
||||
_batChargeRecmd ($centpars); # Batterie Ladeempfehlung berechnen und erstellen
|
||||
_manageConsumerData ($centpars); # Consumer Daten sammeln und Zeiten planen
|
||||
_estConsumptionForecast ($centpars); # Verbrauchsprognose erstellen
|
||||
_evaluateThresholds ($centpars); # Schwellenwerte bewerten und signalisieren
|
||||
@ -8387,16 +8398,8 @@ sub __calcPVestimates {
|
||||
|
||||
$data{$type}{$name}{current}{allstringspeak} = $peaksum; # temperaturbedingte Korrektur der installierten Peakleistung in W
|
||||
$pvsum = $peaksum if($peaksum && $pvsum > $peaksum); # Vorhersage nicht größer als die Summe aller PV-Strings Peak
|
||||
|
||||
my $logao = qq{};
|
||||
$paref->{pvsum} = $pvsum;
|
||||
$paref->{peaksum} = $peaksum;
|
||||
$pvsum = sprintf "%.0f", $pvsum;
|
||||
|
||||
($pvsum, $logao) = ___70percentRule ($paref);
|
||||
|
||||
delete $paref->{peaksum};
|
||||
delete $paref->{pvsum};
|
||||
|
||||
if ($debug =~ /radiationProcess/xs) {
|
||||
$lh = { # Log-Hash zur Ausgabe
|
||||
"Starttime" => $wantdt,
|
||||
@ -8404,7 +8407,7 @@ sub __calcPVestimates {
|
||||
"Cloudcover" => $wcc,
|
||||
"Total Rain last hour" => $rr1c." kg/m2",
|
||||
"PV Correction mode" => ($acu ? $acu : 'no'),
|
||||
"PV generation forecast" => $pvsum." Wh ".$logao,
|
||||
"PV generation forecast" => $pvsum." Wh",
|
||||
};
|
||||
|
||||
$sq = q{};
|
||||
@ -8518,36 +8521,6 @@ sub ___calcPeaklossByTemp {
|
||||
return ($peakloss, $modtemp);
|
||||
}
|
||||
|
||||
################################################################
|
||||
# 70% Regel kalkulieren
|
||||
################################################################
|
||||
sub ___70percentRule {
|
||||
my $paref = shift;
|
||||
my $name = $paref->{name};
|
||||
my $pvsum = $paref->{pvsum};
|
||||
my $peaksum = $paref->{peaksum};
|
||||
my $num = $paref->{num}; # Nexthour
|
||||
|
||||
my $hash = $defs{$name};
|
||||
my $logao = qq{};
|
||||
my $confc = NexthoursVal ($hash, "NextHour".sprintf("%02d",$num), "confc", 0);
|
||||
my $max70 = $peaksum/100 * 70;
|
||||
|
||||
if (AttrVal ($name, "affect70percentRule", "0") eq "1" && $pvsum > $max70) {
|
||||
$pvsum = $max70;
|
||||
$logao = qq{(reduced by 70 percent rule)};
|
||||
}
|
||||
|
||||
if (AttrVal ($name, "affect70percentRule", "0") eq "dynamic" && $pvsum > $max70 + $confc) {
|
||||
$pvsum = $max70 + $confc;
|
||||
$logao = qq{(reduced by 70 percent dynamic rule)};
|
||||
}
|
||||
|
||||
$pvsum = int $pvsum;
|
||||
|
||||
return ($pvsum, $logao);
|
||||
}
|
||||
|
||||
################################################################
|
||||
# den Maximalwert PV Vorhersage für Heute ermitteln
|
||||
################################################################
|
||||
@ -8651,14 +8624,15 @@ sub _transferInverterValues {
|
||||
|
||||
my $feed = $h->{feed} // 'default';
|
||||
|
||||
$data{$type}{$name}{inverters}{$in}{igeneration} = $pv; # Hilfshash Wert current generation, Forum: https://forum.fhem.de/index.php/topic,117864.msg1139251.html#msg1139251
|
||||
$data{$type}{$name}{inverters}{$in}{ietotal} = $etotal; # aktuellen etotal des WR speichern
|
||||
$data{$type}{$name}{inverters}{$in}{iname} = $indev; # Name des Inverterdevices
|
||||
$data{$type}{$name}{inverters}{$in}{ialias} = AttrVal ($indev, 'alias', $indev); # Alias Inverter
|
||||
$data{$type}{$name}{inverters}{$in}{invertercap} = $h->{capacity} if(defined $h->{capacity}); # optionale Angabe max. WR-Leistung
|
||||
$data{$type}{$name}{inverters}{$in}{iicon} = $h->{icon} if($h->{icon}); # Icon des Inverters
|
||||
$data{$type}{$name}{inverters}{$in}{istrings} = $h->{strings} if($h->{strings}); # dem Inverter zugeordnete Strings
|
||||
$data{$type}{$name}{inverters}{$in}{ifeed} = $feed; # Eigenschaften der Energielieferung
|
||||
$data{$type}{$name}{inverters}{$in}{igeneration} = $pv; # Hilfshash Wert current generation, Forum: https://forum.fhem.de/index.php/topic,117864.msg1139251.html#msg1139251
|
||||
$data{$type}{$name}{inverters}{$in}{ietotal} = $etotal; # aktuellen etotal des WR speichern
|
||||
$data{$type}{$name}{inverters}{$in}{iname} = $indev; # Name des Inverterdevices
|
||||
$data{$type}{$name}{inverters}{$in}{ialias} = AttrVal ($indev, 'alias', $indev); # Alias Inverter
|
||||
$data{$type}{$name}{inverters}{$in}{invertercap} = $h->{capacity} if(defined $h->{capacity}); # optionale Angabe max. WR-Leistung
|
||||
$data{$type}{$name}{inverters}{$in}{ilimit} = $h->{limit} // 100; # Wirkleistungsbegrenzung
|
||||
$data{$type}{$name}{inverters}{$in}{iicon} = $h->{icon} if($h->{icon}); # Icon des Inverters
|
||||
$data{$type}{$name}{inverters}{$in}{istrings} = $h->{strings} if($h->{strings}); # dem Inverter zugeordnete Strings
|
||||
$data{$type}{$name}{inverters}{$in}{ifeed} = $feed; # Eigenschaften der Energielieferung
|
||||
|
||||
$pvsum += $pv;
|
||||
$ethishoursum += $ethishour;
|
||||
@ -9312,6 +9286,112 @@ sub __batSaveSocKeyFigures {
|
||||
return;
|
||||
}
|
||||
|
||||
################################################################
|
||||
# Erstellung Batterie Ladeempfehlung
|
||||
################################################################
|
||||
sub _batChargeRecmd {
|
||||
my $paref = shift;
|
||||
my $name = $paref->{name};
|
||||
my $chour = $paref->{chour};
|
||||
|
||||
return if(!isBatteryUsed ($name));
|
||||
|
||||
my $hash = $defs{$name};
|
||||
|
||||
my $rodpvfc = ReadingsNum ($name, 'RestOfDayPVforecast', 0); # PV Prognose Rest des Tages
|
||||
my $tompvfc = ReadingsNum ($name, 'Tomorrow_PVforecast', 0); # PV Prognose nächster Tag
|
||||
|
||||
my $confcss = CurrentVal ($hash, 'tdConFcTillSunset', 0); # Verbrauchsprognose bis Sonnenuntergang
|
||||
my $tomconfc = ReadingsNum ($name, 'Tomorrow_ConsumptionForecast', 0);
|
||||
|
||||
my $pvCu = ReadingsNum ($name, 'Current_PV', 0); # aktuelle PV Erzeugung
|
||||
my $batcap = CurrentVal ($hash, 'batinstcap', 0); # installierte Batteriekapazität Wh
|
||||
my $soc = CurrentVal ($hash, 'batcharge', 0); # aktueller SOC (%)
|
||||
my $curcon = ReadingsNum ($name, 'Current_Consumption', 0); # aktueller Verbrauch
|
||||
|
||||
my $inpmax = 0;
|
||||
|
||||
for my $in (1..$maxinverter) {
|
||||
$in = sprintf "%02d", $in;
|
||||
my $feed = InverterVal ($hash, $in, 'ifeed', '');
|
||||
next if(!$feed || $feed eq 'grid'); # Inverter 'Grid' ausschließen
|
||||
|
||||
my $iname = InverterVal ($hash, $in, 'iname', '');
|
||||
my $icap = InverterVal ($hash, $in, 'invertercap', 0);
|
||||
my $limit = InverterVal ($hash, $in, 'ilimit', 100); # Wirkleistungsbegrenzung (default keine Begrenzung)
|
||||
my $aplim = $icap * $limit / 100;
|
||||
$inpmax += $aplim; # max. Leistung aller WR mit Berücksichtigung Wirkleistungsbegrenzung
|
||||
|
||||
debugLog ($paref, 'batteryManagement', "Inverter '$iname' capacity: $icap, Active power limit: $limit % -> Pmax limited: $aplim");
|
||||
}
|
||||
|
||||
debugLog ($paref, 'batteryManagement', "Summary active power limit of all Inverter (except feed 'grid'): $inpmax");
|
||||
debugLog ($paref, 'batteryManagement', "Installed Battery capacity: $batcap");
|
||||
|
||||
if (!$inpmax || !$batcap) {
|
||||
debugLog ($paref, 'batteryManagement', "WARNING - The requirements for dynamic battery charge recommendation are not met. Exit.");
|
||||
return;
|
||||
}
|
||||
|
||||
my $sfmargin = $inpmax * 0.5; # Sicherheitszuschlag 50% der installierten Leistung (Wh)
|
||||
my $betEneed = sprintf "%.0f", ($batcap - ($batcap * $soc / 100)); # benötigte Energie bis 100% Batteriekapazität Wh
|
||||
|
||||
for my $num (0..47) {
|
||||
my ($fd,$fh) = calcDayHourMove ($chour, $num);
|
||||
next if($fd > 1);
|
||||
|
||||
my $today = NexthoursVal ($hash, 'NextHour'.sprintf("%02d",$num), 'today', 0);
|
||||
my $confc = NexthoursVal ($hash, 'NextHour'.sprintf("%02d",$num), 'confc', 0);
|
||||
my $pvfc = NexthoursVal ($hash, 'NextHour'.sprintf("%02d",$num), 'pvfc', 0);
|
||||
my $stt = NexthoursVal ($hash, 'NextHour'.sprintf("%02d",$num), 'starttime', '');
|
||||
$stt = (split '-', $stt)[2] if($stt);
|
||||
|
||||
my $dold = 0; # Ladeempfehlung 0 per Default
|
||||
my $spday = 0;
|
||||
|
||||
if ($today) { # (Rest) heutiger Tag
|
||||
$spday = $rodpvfc - $confcss;
|
||||
}
|
||||
else { # nächster Tag
|
||||
$spday = $tompvfc - $tomconfc;
|
||||
}
|
||||
|
||||
$spday = 0 if($spday < 0); # PV Überschuß Prognose bis Sonnenuntergang
|
||||
|
||||
if ( $betEneed + $sfmargin >= $spday ) {$dold = 1} # Ladeempfehlung wenn benötigte Ladeenergie >= Restüberschuß des Tages zzgl. Sicherheitsaufschlag
|
||||
if ( !$num && $pvCu - $curcon >= $inpmax ) {$dold = 1} # Ladeempfehlung wenn akt. PV Leistung >= WR-Leistungsbegrenzung
|
||||
|
||||
my $msg = "(Eneed: $betEneed -> Surplus Day: $spday, Curr PV: $pvCu, Curr Consumption: $curcon -> Limit: $inpmax)";
|
||||
|
||||
if ($num) {
|
||||
$msg = "(Eneed: $betEneed -> Surplus Day: $spday)";
|
||||
}
|
||||
else {
|
||||
storeReading ('Battery_ChargeRecommended', $dold); # Reading nur für aktuelle Stunde
|
||||
}
|
||||
|
||||
debugLog ($paref, 'batteryManagement', "Charge activation $stt -> $dold $msg");
|
||||
|
||||
if ($pvfc) {
|
||||
if ($today) { # (Rest) heutiger Tag
|
||||
$confcss -= $confc;
|
||||
$confcss = 0 if($confcss < 0);
|
||||
$rodpvfc -= $pvfc;
|
||||
}
|
||||
else { # nächster Tag
|
||||
$tomconfc -= $confc;
|
||||
$tomconfc = 0 if($tomconfc < 0);
|
||||
$tompvfc -= $pvfc;
|
||||
}
|
||||
}
|
||||
|
||||
$betEneed -= sprintf "%.0f", ($pvfc - $confc);
|
||||
$betEneed = $betEneed < 0 ? 0 : $betEneed;
|
||||
}
|
||||
|
||||
return;
|
||||
}
|
||||
|
||||
################################################################
|
||||
# Zusammenfassungen erstellen
|
||||
################################################################
|
||||
@ -12022,48 +12102,9 @@ sub FwFn {
|
||||
$ret .= entryGraphic ($name);
|
||||
$ret .= "</html>";
|
||||
|
||||
# Autorefresh nur des aufrufenden FHEMWEB-Devices
|
||||
my $al = AttrVal ($name, 'ctrlAutoRefresh', 0);
|
||||
if ($al) {
|
||||
pageRefresh ($hash);
|
||||
}
|
||||
|
||||
return $ret;
|
||||
}
|
||||
|
||||
###########################################################################
|
||||
# Seitenrefresh festgelegt durch SolarForecast-Attribut "ctrlAutoRefresh"
|
||||
# und "ctrlAutoRefreshFW"
|
||||
###########################################################################
|
||||
sub pageRefresh {
|
||||
my $hash = shift;
|
||||
my $name = $hash->{NAME};
|
||||
|
||||
my $al = AttrVal($name, 'ctrlAutoRefresh', 0);
|
||||
|
||||
if ($al) {
|
||||
my $rftime = gettimeofday()+$al;
|
||||
|
||||
if (!$hash->{HELPER}{AREFRESH} || $hash->{HELPER}{AREFRESH} <= gettimeofday()) {
|
||||
RemoveInternalTimer ($hash, \&pageRefresh);
|
||||
InternalTimer($rftime, \&pageRefresh, $hash, 0);
|
||||
|
||||
my $rd = AttrVal ($name, 'ctrlAutoRefreshFW', $hash->{HELPER}{FW});
|
||||
{ map { FW_directNotify("#FHEMWEB:$_", "location.reload('true')", "") } $rd } ## no critic 'Map blocks'
|
||||
|
||||
$hash->{HELPER}{AREFRESH} = $rftime;
|
||||
$hash->{AUTOREFRESH} = FmtDateTime($rftime);
|
||||
}
|
||||
}
|
||||
else {
|
||||
delete $hash->{HELPER}{AREFRESH};
|
||||
delete $hash->{AUTOREFRESH};
|
||||
RemoveInternalTimer ($hash, \&pageRefresh);
|
||||
}
|
||||
|
||||
return;
|
||||
}
|
||||
|
||||
################################################################
|
||||
# Grafik als HTML zurück liefern (z.B. für Widget)
|
||||
################################################################
|
||||
@ -12153,7 +12194,8 @@ sub entryGraphic {
|
||||
hdrDetail => AttrVal ($name, 'graphicHeaderDetail', 'all'), # ermöglicht den Inhalt zu begrenzen, um bspw. passgenau in ftui einzubetten
|
||||
flowgsize => CurrentVal ($hash, 'size', $flowGSizedef), # Größe Energieflußgrafik
|
||||
flowgani => CurrentVal ($hash, 'animate', 1), # Animation Energieflußgrafik
|
||||
flowgshift => CurrentVal ($hash, 'shift', 0), # Verschiebung der Flußgrafikbox (muß negiert werden)
|
||||
flowgxshift => CurrentVal ($hash, 'shiftx', 0), # X-Verschiebung der Flußgrafikbox (muß negiert werden)
|
||||
flowgyshift => CurrentVal ($hash, 'shifty', 0), # Y-Verschiebung der Flußgrafikbox (muß negiert werden)
|
||||
flowgcons => CurrentVal ($hash, 'showconsumer', 1), # Verbraucher in der Energieflußgrafik anzeigen
|
||||
flowgconX => CurrentVal ($hash, 'showconsumerdummy', 1), # Dummyverbraucher in der Energieflußgrafik anzeigen
|
||||
flowgconsPower => CurrentVal ($hash, 'showconsumerpower', 1), # Verbraucher Leistung in der Energieflußgrafik anzeigen
|
||||
@ -14217,7 +14259,8 @@ sub _flowGraphic {
|
||||
my $type = $paref->{type};
|
||||
my $flowgsize = $paref->{flowgsize};
|
||||
my $flowgani = $paref->{flowgani};
|
||||
my $flowgshift = $paref->{flowgshift}; # Verschiebung der Flußgrafikbox (muß negiert werden)
|
||||
my $flowgxshift = $paref->{flowgxshift}; # X-Verschiebung der Flußgrafikbox (muß negiert werden)
|
||||
my $flowgyshift = $paref->{flowgyshift}; # Y-Verschiebung der Flußgrafikbox (muß negiert werden)
|
||||
my $flowgcons = $paref->{flowgcons}; # Verbraucher in der Energieflußgrafik anzeigen
|
||||
my $flowgconsTime = $paref->{flowgconsTime}; # Verbraucher Restlaufeit in der Energieflußgrafik anzeigen
|
||||
my $flowgconX = $paref->{flowgconX};
|
||||
@ -14373,7 +14416,7 @@ sub _flowGraphic {
|
||||
## SVG Box initialisieren mit Grid-Icon
|
||||
#########################################
|
||||
my $vbwidth = 800; # width and height specify the viewBox size
|
||||
my $vbminx = -10 * $flowgshift; # min-x and min-y represent the smallest X and Y coordinates that the viewBox may have
|
||||
my $vbminx = -10 * $flowgxshift; # min-x and min-y represent the smallest X and Y coordinates that the viewBox may have
|
||||
my $vbminy = $doproducerrow ? -25 : 125; # Grafik höher positionieren wenn keine Poducerreihe angezeigt
|
||||
|
||||
my $vbhight = !$flowgcons ? 380 :
|
||||
@ -14381,6 +14424,9 @@ sub _flowGraphic {
|
||||
610;
|
||||
$vbhight += $exth2cdist;
|
||||
|
||||
$vbminy -= $flowgyshift; # Y-Verschiebung berücksichtigen
|
||||
$vbhight += $flowgyshift; # Y-Verschiebung berücksichtigen
|
||||
|
||||
if ($doproducerrow) {$vbhight += 100}; # Höhe Box vergrößern wenn Poducerreihe angezeigt
|
||||
|
||||
my $vbox = "$vbminx $vbminy $vbwidth $vbhight";
|
||||
@ -20537,22 +20583,6 @@ to ensure that the system configuration is correct.
|
||||
<br><br>
|
||||
<ul>
|
||||
<ul>
|
||||
<a id="SolarForecast-attr-affect70percentRule"></a>
|
||||
<li><b>affect70percentRule</b><br>
|
||||
If set, the predicted power is limited according to the 70% rule. <br><br>
|
||||
|
||||
<ul>
|
||||
<table>
|
||||
<colgroup> <col width="15%"> <col width="85%"> </colgroup>
|
||||
<tr><td> <b>0</b> </td><td>No limit on the forecast PV generation (default) </td></tr>
|
||||
<tr><td> <b>1</b> </td><td>the predicted PV generation is limited to 70% of the installed string power(s) </td></tr>
|
||||
<tr><td> <b>dynamic</b> </td><td>the predicted PV generation is limited when 70% of the installed </td></tr>
|
||||
<tr><td> </td><td>string(s) power plus the predicted consumption is exceeded. </td></tr>
|
||||
</table>
|
||||
</ul>
|
||||
</li>
|
||||
<br>
|
||||
|
||||
<a id="SolarForecast-attr-affectBatteryPreferredCharge"></a>
|
||||
<li><b>affectBatteryPreferredCharge </b><br>
|
||||
Consumers with the <b>can</b> mode are only switched on when the specified battery charge (%)
|
||||
@ -20862,21 +20892,6 @@ to ensure that the system configuration is correct.
|
||||
</li>
|
||||
<br>
|
||||
|
||||
<a id="SolarForecast-attr-ctrlAutoRefresh"></a>
|
||||
<li><b>ctrlAutoRefresh</b> <br>
|
||||
If set, active browser pages of the FHEMWEB device that has called up the SolarForecast device are
|
||||
reloaded after the set time (seconds). If browser pages of a certain FHEMWEB device are to be reloaded
|
||||
instead, this device can be specified with the attribute "ctrlAutoRefreshFW".
|
||||
</li>
|
||||
<br>
|
||||
|
||||
<a id="SolarForecast-attr-ctrlAutoRefreshFW"></a>
|
||||
<li><b>ctrlAutoRefreshFW</b><br>
|
||||
If "ctrlAutoRefresh" is activated, this attribute can be used to determine the FHEMWEB device whose active browser pages
|
||||
should be regularly reloaded.
|
||||
</li>
|
||||
<br>
|
||||
|
||||
<a id="SolarForecast-attr-ctrlBackupFilesKeep"></a>
|
||||
<li><b>ctrlBackupFilesKeep <Integer> </b><br>
|
||||
Defines the number of generations of backup files
|
||||
@ -21138,9 +21153,12 @@ to ensure that the system configuration is correct.
|
||||
<tr><td> <b>h2consumerdist</b> </td><td>Extension of the vertical distance between the house and the consumer icons. </td></tr>
|
||||
<tr><td> </td><td>Value: <b>0 ... 999</b>, default: 0 </td></tr>
|
||||
<tr><td> </td><td> </td></tr>
|
||||
<tr><td> <b>shift</b> </td><td>Horizontal shift of the energy flow graph. </td></tr>
|
||||
<tr><td> <b>shiftx</b> </td><td>Horizontal shift of the energy flow graph. </td></tr>
|
||||
<tr><td> </td><td>Value: <b>-80 ... 80</b>, default: 0 </td></tr>
|
||||
<tr><td> </td><td> </td></tr>
|
||||
<tr><td> <b>shifty</b> </td><td>Vertical shift of the energy flow chart. </td></tr>
|
||||
<tr><td> </td><td>Wert: <b>Integer</b>, default: 0 </td></tr>
|
||||
<tr><td> </td><td> </td></tr>
|
||||
<tr><td> <b>showconsumer</b> </td><td>Display of consumers in the energy flow chart. </td></tr>
|
||||
<tr><td> </td><td><b>0</b> - Display off, <b>1</b> - Display on, default: 1 </td></tr>
|
||||
<tr><td> </td><td> </td></tr>
|
||||
@ -21173,7 +21191,7 @@ to ensure that the system configuration is correct.
|
||||
|
||||
<ul>
|
||||
<b>Example: </b> <br>
|
||||
attr <name> flowGraphicControl size=300 animate=0 consumerdist=100 showconsumer=1 showconsumerdummy=0 shift=-20 strokewidth=15 strokecolstd=#99cc00
|
||||
attr <name> flowGraphicControl size=300 animate=0 consumerdist=100 showconsumer=1 showconsumerdummy=0 shiftx=-20 strokewidth=15 strokecolstd=#99cc00
|
||||
</ul>
|
||||
|
||||
</li>
|
||||
@ -21543,7 +21561,7 @@ to ensure that the system configuration is correct.
|
||||
<a id="SolarForecast-attr-setupBatteryDev"></a>
|
||||
<li><b>setupBatteryDev <Battery Device Name> pin=<Readingname>:<Unit> pout=<Readingname>:<Unit>
|
||||
[intotal=<Readingname>:<Unit>] [outtotal=<Readingname>:<Unit>]
|
||||
[cap=<Option>] [charge=<Readingname>] </b> <br><br>
|
||||
cap=<Option> [charge=<Readingname>] </b> <br><br>
|
||||
|
||||
Specifies an arbitrary Device and its Readings to deliver the battery performance data.
|
||||
The module assumes that the numerical value of the readings is always positive.
|
||||
@ -21557,7 +21575,7 @@ to ensure that the system configuration is correct.
|
||||
<tr><td> <b>pout</b> </td><td>Reading which provides the current battery discharge rate </td></tr>
|
||||
<tr><td> <b>intotal</b> </td><td>Reading which provides the total battery charge as a continuous counter (optional) </td></tr>
|
||||
<tr><td> <b>outtotal</b> </td><td>Reading which provides the total battery discharge as a continuous counter (optional) </td></tr>
|
||||
<tr><td> <b>cap</b> </td><td>installed battery capacity (optional). Option can be: </td></tr>
|
||||
<tr><td> <b>cap</b> </td><td>installed battery capacity. Option can be: </td></tr>
|
||||
<tr><td> </td><td><b>numerical value</b> - direct indication of the battery capacity in Wh </td></tr>
|
||||
<tr><td> </td><td><b><Readingname>:<unit></b> - Reading which provides the capacity and unit (Wh, kWh) </td></tr>
|
||||
<tr><td> <b>charge</b> </td><td>Reading which provides the current state of charge (SOC in percent) (optional) </td></tr>
|
||||
@ -21588,8 +21606,8 @@ to ensure that the system configuration is correct.
|
||||
|
||||
<a id="SolarForecast-attr-setupInverterDev" data-pattern="setupInverterDev.*"></a>
|
||||
<li><b>setupInverterDevXX <Inverter Device Name> pv=<Readingname>:<Unit> etotal=<Readingname>:<Unit>
|
||||
[capacity=<max. WR-Leistung>] [strings=<String1>,<String2>,...]
|
||||
[feed=<Delivery type>]
|
||||
capacity=<max. WR-Leistung> [strings=<String1>,<String2>,...]
|
||||
[feed=<Delivery type>] [limit=<0..100>]
|
||||
[icon=<Day>[@<Color>][:<Night>[@<Color>]]] </b> <br><br>
|
||||
|
||||
Defines any inverter device or solar charger and its readings to supply the current PV generation values. <br>
|
||||
@ -21600,7 +21618,6 @@ to ensure that the system configuration is correct.
|
||||
This can also be a dummy device with corresponding readings. <br>
|
||||
The values of several inverters can be combined in a dummy device, for example, and this device can
|
||||
be specified with the corresponding readings. <br>
|
||||
Specifying <b>capacity</b> is optional, but strongly recommended to optimize prediction accuracy.
|
||||
<br><br>
|
||||
|
||||
<ul>
|
||||
@ -21612,7 +21629,6 @@ to ensure that the system configuration is correct.
|
||||
<tr><td> </td><td>SolarForecast handles this error and reports the situation by means of a log message. </td></tr>
|
||||
<tr><td> <b>Einheit</b> </td><td>the respective unit (W,kW,Wh,kWh) </td></tr>
|
||||
<tr><td> <b>capacity</b> </td><td>Rated power of the inverter according to data sheet, i.e. max. possible output in Watts </td></tr>
|
||||
<tr><td> </td><td>(The entry is optional, but is strongly recommended) </td></tr>
|
||||
<tr><td> <b>strings</b> </td><td>Comma-separated list of the strings assigned to the inverter (optional). The string names </td></tr>
|
||||
<tr><td> </td><td>are defined in the <a href=“#SolarForecast-attr-setupInverterStrings”>setupInverterStrings</a> attribute. </td></tr>
|
||||
<tr><td> </td><td>If 'strings' is not specified, all defined string names are assigned to the inverter. </td></tr>
|
||||
@ -21620,6 +21636,7 @@ to ensure that the system configuration is correct.
|
||||
<tr><td> </td><td>If the key is not set, the device feeds the PV energy into the house's AC grid. </td></tr>
|
||||
<tr><td> </td><td><b>bat</b> - the device supplies energy exclusively to the battery </td></tr>
|
||||
<tr><td> </td><td><b>grid</b> - the energy is fed exclusively into the public grid </td></tr>
|
||||
<tr><td> <b>limit</b> </td><td>Defines any active power limitation in % (optional). </td></tr>
|
||||
<tr><td> <b>icon</b> </td><td>Icon for displaying the inverter in the flow chart (optional) </td></tr>
|
||||
<tr><td> </td><td><b><Day></b> - Icon and optional color for activity after sunrise </td></tr>
|
||||
<tr><td> </td><td><b><Night></b> - Icon and optional color after sunset, otherwise the moon phase is displayed </td></tr>
|
||||
@ -22930,22 +22947,6 @@ die ordnungsgemäße Anlagenkonfiguration geprüft werden.
|
||||
<br><br>
|
||||
<ul>
|
||||
<ul>
|
||||
<a id="SolarForecast-attr-affect70percentRule"></a>
|
||||
<li><b>affect70percentRule</b><br>
|
||||
Wenn gesetzt, wird die prognostizierte Leistung entsprechend der 70% Regel begrenzt. <br><br>
|
||||
|
||||
<ul>
|
||||
<table>
|
||||
<colgroup> <col width="15%"> <col width="85%"> </colgroup>
|
||||
<tr><td> <b>0</b> </td><td>keine Begrenzung der prognostizierten PV-Erzeugung (default) </td></tr>
|
||||
<tr><td> <b>1</b> </td><td>die prognostizierte PV-Erzeugung wird auf 70% der installierten Stringleistung(en) begrenzt </td></tr>
|
||||
<tr><td> <b>dynamic</b> </td><td>die prognostizierte PV-Erzeugung wird begrenzt wenn 70% der installierten </td></tr>
|
||||
<tr><td> </td><td>Stringleistung(en) zzgl. des prognostizierten Verbrauchs überschritten wird </td></tr>
|
||||
</table>
|
||||
</ul>
|
||||
</li>
|
||||
<br>
|
||||
|
||||
<a id="SolarForecast-attr-affectBatteryPreferredCharge"></a>
|
||||
<li><b>affectBatteryPreferredCharge </b><br>
|
||||
Es werden Verbraucher mit dem Mode <b>can</b> erst dann eingeschaltet, wenn die angegebene Batterieladung (%)
|
||||
@ -23255,21 +23256,6 @@ die ordnungsgemäße Anlagenkonfiguration geprüft werden.
|
||||
</li>
|
||||
<br>
|
||||
|
||||
<a id="SolarForecast-attr-ctrlAutoRefresh"></a>
|
||||
<li><b>ctrlAutoRefresh</b> <br>
|
||||
Wenn gesetzt, werden aktive Browserseiten des FHEMWEB-Devices welches das SolarForecast-Device aufgerufen hat, nach der
|
||||
eingestellten Zeit (Sekunden) neu geladen. Sollen statt dessen Browserseiten eines bestimmten FHEMWEB-Devices neu
|
||||
geladen werden, kann dieses Device mit dem Attribut "ctrlAutoRefreshFW" festgelegt werden.
|
||||
</li>
|
||||
<br>
|
||||
|
||||
<a id="SolarForecast-attr-ctrlAutoRefreshFW"></a>
|
||||
<li><b>ctrlAutoRefreshFW</b><br>
|
||||
Ist "ctrlAutoRefresh" aktiviert, kann mit diesem Attribut das FHEMWEB-Device bestimmt werden dessen aktive Browserseiten
|
||||
regelmäßig neu geladen werden sollen.
|
||||
</li>
|
||||
<br>
|
||||
|
||||
<a id="SolarForecast-attr-ctrlBackupFilesKeep"></a>
|
||||
<li><b>ctrlBackupFilesKeep <Ganzzahl></b><br>
|
||||
Legt die Anzahl der Generationen von Sicherungsdateien
|
||||
@ -23533,9 +23519,12 @@ die ordnungsgemäße Anlagenkonfiguration geprüft werden.
|
||||
<tr><td> <b>h2consumerdist</b> </td><td>Erweiterung des vertikalen Abstandes zwischen dem Haus und den Verbraucher-Icons. </td></tr>
|
||||
<tr><td> </td><td>Wert: <b>0 ... 999</b>, default: 0 </td></tr>
|
||||
<tr><td> </td><td> </td></tr>
|
||||
<tr><td> <b>shift</b> </td><td>Horizontale Verschiebung der Energieflußgrafik. </td></tr>
|
||||
<tr><td> <b>shiftx</b> </td><td>Horizontale Verschiebung der Energieflußgrafik. </td></tr>
|
||||
<tr><td> </td><td>Wert: <b>-80 ... 80</b>, default: 0 </td></tr>
|
||||
<tr><td> </td><td> </td></tr>
|
||||
<tr><td> <b>shifty</b> </td><td>Vertikale Verschiebung der Energieflußgrafik. </td></tr>
|
||||
<tr><td> </td><td>Wert: <b>Ganzzahl</b>, default: 0 </td></tr>
|
||||
<tr><td> </td><td> </td></tr>
|
||||
<tr><td> <b>showconsumer</b> </td><td>Anzeige der Verbraucher in der Energieflußgrafik. </td></tr>
|
||||
<tr><td> </td><td><b>0</b> - Anzeige aus, <b>1</b> - Anzeige an, default: 1 </td></tr>
|
||||
<tr><td> </td><td> </td></tr>
|
||||
@ -23568,7 +23557,7 @@ die ordnungsgemäße Anlagenkonfiguration geprüft werden.
|
||||
|
||||
<ul>
|
||||
<b>Beispiel: </b> <br>
|
||||
attr <name> flowGraphicControl size=300 animate=0 consumerdist=100 showconsumer=1 showconsumerdummy=0 shift=-20 strokewidth=15 strokecolstd=#99cc00
|
||||
attr <name> flowGraphicControl size=300 animate=0 consumerdist=100 showconsumer=1 showconsumerdummy=0 shiftx=-20 strokewidth=15 strokecolstd=#99cc00
|
||||
</ul>
|
||||
|
||||
</li>
|
||||
@ -23937,7 +23926,7 @@ die ordnungsgemäße Anlagenkonfiguration geprüft werden.
|
||||
<a id="SolarForecast-attr-setupBatteryDev"></a>
|
||||
<li><b>setupBatteryDev <Batterie Device Name> pin=<Readingname>:<Einheit> pout=<Readingname>:<Einheit>
|
||||
[intotal=<Readingname>:<Einheit>] [outtotal=<Readingname>:<Einheit>]
|
||||
[cap=<Option>] [charge=<Readingname>] </b> <br><br>
|
||||
cap=<Option> [charge=<Readingname>] </b> <br><br>
|
||||
|
||||
Legt ein beliebiges Device und seine Readings zur Lieferung der Batterie Leistungsdaten fest.
|
||||
Das Modul geht davon aus, dass der numerische Wert der Readings immer positiv ist.
|
||||
@ -23951,7 +23940,7 @@ die ordnungsgemäße Anlagenkonfiguration geprüft werden.
|
||||
<tr><td> <b>pout</b> </td><td>Reading welches die aktuelle Batterieentladeleistung liefert </td></tr>
|
||||
<tr><td> <b>intotal</b> </td><td>Reading welches die totale Batterieladung als fortlaufenden Zähler liefert (optional) </td></tr>
|
||||
<tr><td> <b>outtotal</b> </td><td>Reading welches die totale Batterieentladung als fortlaufenden Zähler liefert (optional) </td></tr>
|
||||
<tr><td> <b>cap</b> </td><td>installierte Batteriekapazität (optional). Option kann sein: </td></tr>
|
||||
<tr><td> <b>cap</b> </td><td>installierte Batteriekapazität. Option kann sein: </td></tr>
|
||||
<tr><td> </td><td><b>numerischer Wert</b> - direkte Angabe der Batteriekapazität in Wh </td></tr>
|
||||
<tr><td> </td><td><b><Readingname>:<Einheit></b> - Reading welches die Kapazität liefert und Einheit (Wh, kWh) </td></tr>
|
||||
<tr><td> <b>charge</b> </td><td>Reading welches den aktuellen Ladezustand (SOC in Prozent) liefert (optional) </td></tr>
|
||||
@ -23982,8 +23971,8 @@ die ordnungsgemäße Anlagenkonfiguration geprüft werden.
|
||||
|
||||
<a id="SolarForecast-attr-setupInverterDev" data-pattern="setupInverterDev.*"></a>
|
||||
<li><b>setupInverterDevXX <Inverter Device Name> pv=<Readingname>:<Einheit> etotal=<Readingname>:<Einheit>
|
||||
[capacity=<max. WR-Leistung>] [strings=<String1>,<String2>,...]
|
||||
[feed=<Liefertyp>]
|
||||
capacity=<max. WR-Leistung> [strings=<String1>,<String2>,...]
|
||||
[feed=<Liefertyp>] [limit=<0..100>]
|
||||
[icon=<Tag>[@<Farbe>][:<Nacht>[@<Farbe>]]] </b> <br><br>
|
||||
|
||||
Legt ein beliebiges Wechselrichter-Gerät bzw. Solar-Ladegerät und dessen Readings zur Lieferung der aktuellen
|
||||
@ -23995,7 +23984,6 @@ die ordnungsgemäße Anlagenkonfiguration geprüft werden.
|
||||
Dabei kann es sich auch um ein Dummy Gerät mit entsprechenden Readings handeln. <br>
|
||||
Die Werte mehrerer Wechselrichter kann man z.B. in einem Dummy Gerät zusammenführen und gibt dieses Gerät mit
|
||||
den entsprechenden Readings an. <br>
|
||||
Die Angabe von <b>capacity</b> ist optional, wird aber zur Optimierung der Vorhersagegenauigkeit dringend empfohlen.
|
||||
<br><br>
|
||||
|
||||
<ul>
|
||||
@ -24007,7 +23995,6 @@ die ordnungsgemäße Anlagenkonfiguration geprüft werden.
|
||||
<tr><td> </td><td>SolarForecast diesen Fehler und meldet die aufgetretene Situation durch einen Logeintrag. </td></tr>
|
||||
<tr><td> <b>Einheit</b> </td><td>die jeweilige Einheit (W,kW,Wh,kWh) </td></tr>
|
||||
<tr><td> <b>capacity</b> </td><td>Bemessungsleistung des Wechselrichters gemäß Datenblatt, d.h. max. möglicher Output in Watt </td></tr>
|
||||
<tr><td> </td><td>(Die Angabe ist optional, wird aber dringend empfohlen zu setzen) </td></tr>
|
||||
<tr><td> <b>strings</b> </td><td>Komma getrennte Liste der dem Wechselrichter zugeordneten Strings (optional). Die Stringnamen </td></tr>
|
||||
<tr><td> </td><td>werden im Attribut <a href="#SolarForecast-attr-setupInverterStrings">setupInverterStrings</a> definiert. </td></tr>
|
||||
<tr><td> </td><td>Ist 'strings' nicht angegeben, werden alle definierten Stringnamen dem Wechselrichter zugeordnet. </td></tr>
|
||||
@ -24015,6 +24002,7 @@ die ordnungsgemäße Anlagenkonfiguration geprüft werden.
|
||||
<tr><td> </td><td>Ist der Schlüssel nicht gesetzt, speist das Gerät die PV-Energie in das Wechselstromnetz des Hauses ein. </td></tr>
|
||||
<tr><td> </td><td><b>bat</b> - das Gerät liefert die Energie ausschließlich an die Batterie </td></tr>
|
||||
<tr><td> </td><td><b>grid</b> - die Energie wird ausschließlich in das öffentlich Netz eingespeist </td></tr>
|
||||
<tr><td> <b>limit</b> </td><td>Definiert eine eventuelle Wirkleistungsbeschränkung in % (optional). </td></tr>
|
||||
<tr><td> <b>icon</b> </td><td>Icon zur Darstellung des Inverters in der Flowgrafik (optional) </td></tr>
|
||||
<tr><td> </td><td><b><Tag></b> - Icon und ggf. Farbe bei Aktivität nach Sonnenaufgang </td></tr>
|
||||
<tr><td> </td><td><b><Nacht></b> - Icon und ggf. Farbe nach Sonnenuntergang, sonst wird die Mondphase angezeigt </td></tr>
|
||||
|
Loading…