10_EnOcean: EEP changed: contact (EEP D5-00-01), lightTempOccupSensor.01 (EEP A5-08-01): modified for Eltako sensors TK-BHSB, TF-FKB
git-svn-id: https://svn.fhem.de/fhem/trunk@19820 2b470e98-0d58-463d-a4d8-8e2adae1ed80
This commit is contained in:
parent
6450c9c796
commit
90df134fbd
@ -9765,10 +9765,16 @@ sub EnOcean_Parse($$)
|
||||
|
||||
if ($st eq "lightTempOccupSensor.01") {
|
||||
# Light, Temperatur and Occupancy Sensor (EEP A5-08-01)
|
||||
# [Eltako FABH63, FBH55, FBH63, FIBH63]
|
||||
# [Eltako FABH63, FBH55, FBH63, FIBH63, TF-BHSB]
|
||||
if ($manufID eq "00D") {
|
||||
$lux = sprintf "%d", $db[2] * 2048 / 255;
|
||||
push @event, "3:state:M: $motion E: $lux";
|
||||
if ( $model eq 'Eltako_TF') {
|
||||
$lux = $db[2] << 1;
|
||||
push @event, "3:state:M: $motion E: $lux U: $voltage";
|
||||
push @event, "3:voltage:$voltage";
|
||||
} else {
|
||||
$lux = sprintf "%d", $db[2] * 2048 / 255;
|
||||
push @event, "3:state:M: $motion E: $lux";
|
||||
}
|
||||
} else {
|
||||
$lux = $db[2] << 1;
|
||||
$temp = sprintf "%0.1f", $db[1] * 0.2;
|
||||
@ -10649,6 +10655,11 @@ sub EnOcean_Parse($$)
|
||||
push @event, "3:state:Manufacturer Specific Application unknown";
|
||||
}
|
||||
|
||||
} elsif ($st eq "contact" && $manufID eq "00D") {
|
||||
# Eltako TF-FKB voltage telegram
|
||||
push @event, "3:voltage:" . sprintf "%0.1f", $db[2] * 0.02;
|
||||
push @event, "3:energyStorage:" . sprintf "%0.1f", $db[3] * 0.02;
|
||||
|
||||
} elsif ($st eq "PM101") {
|
||||
# Light and Presence Sensor [Omnio Ratio eagle-PM101]
|
||||
# The sensor also sends switching commands (RORG F6) with the senderID-1
|
||||
@ -18115,7 +18126,8 @@ EnOcean_Delete($$)
|
||||
The attr subType must be contact. The attribute must be set manually.
|
||||
A monitoring period can be set for signOfLife telegrams of the sensor, see
|
||||
<a href="#EnOcean_signOfLife">signOfLife</a> and <a href="#EnOcean_signOfLifeInterval">signOfLifeInterval</a>.
|
||||
Default is "off" and an interval of 1980 sec.
|
||||
Default is "off" and an interval of 1980 sec.<br>
|
||||
Set the manufID to 00D for Eltako devices that send a periodic voltage telegram. (For example TF-FKB)
|
||||
</li><br><br>
|
||||
|
||||
<li>Room Sensor and Control Unit (EEP A5-10-02)<br>
|
||||
@ -20432,17 +20444,19 @@ EnOcean_Delete($$)
|
||||
|
||||
<li>Single Input Contact, Door/Window Contact<br>
|
||||
1BS Telegram (EEP D5-00-01)<br>
|
||||
[EnOcean EMCS, STM 320, STM 329, STM 250, Eltako FTK, Peha D 450 FU]
|
||||
[EnOcean EMCS, STM 320, STM 329, STM 250, Eltako FTK, Peha D 450 FU, Eltako TK-TKB]
|
||||
<ul>
|
||||
<li>closed</li>
|
||||
<li>open</li>
|
||||
<li>alarm: dead_sensor</li>
|
||||
<li>battery: U/V (Range: U = 0 V ... 5 V</li>
|
||||
<li>energyStorage: U/V (Range: U = 0 V ... 5 V</li>
|
||||
<li>teach: <result of teach procedure></li>
|
||||
<li>state: open|closed</li>
|
||||
</ul></li>
|
||||
The device should be created by autocreate. A monitoring period can be set for signOfLife telegrams of the sensor, see
|
||||
<a href="#EnOcean_signOfLife">signOfLife</a> and <a href="#EnOcean_signOfLifeInterval">signOfLifeInterval</a>.
|
||||
Default is "off" and an interval of 1310 sec.
|
||||
Default is "off" and an interval of 1980 sec.
|
||||
<br><br>
|
||||
|
||||
<li>Temperature Sensors with with different ranges (EEP A5-02-01 ... A5-02-30)<br>
|
||||
@ -20642,7 +20656,7 @@ EnOcean_Delete($$)
|
||||
Eltako and PEHA devices only support Brightness and Motion.<br>
|
||||
The attr subType must be lightTempOccupSensor.<01|02|03> and attr
|
||||
manufID must be 00D for Eltako Devices. This is done if the device was
|
||||
created by autocreate.
|
||||
created by autocreate. Set model to Eltako_TF manually for Eltako TF Devices.
|
||||
</li>
|
||||