19_Revolt.pm: don't set event-aggregator automatically, no other FHEM

module does this - but recommend this in commandref. Plus general
improvement of documentation.


git-svn-id: https://svn.fhem.de/fhem/trunk@17447 2b470e98-0d58-463d-a4d8-8e2adae1ed80
This commit is contained in:
gernot-h 2018-10-01 19:13:48 +00:00
parent 113f0830ff
commit 8327abc312

View File

@ -43,7 +43,7 @@ sub Revolt_Define($$)
AssignIoPort($hash);
my $name = $a[0];
$attr{$name}{"event-aggregator"} = "power::none:median:120,energy::none:median:120" if(!defined($attr{$name}{"event-aggregator"}));
#$attr{$name}{"event-aggregator"} = "power::none:median:120,energy::none:median:120" if(!defined($attr{$name}{"event-aggregator"}));
$attr{$name}{"stateFormat"} = "P: power E: energy V: voltage C: current Pf: pf" if(!defined($attr{$name}{"stateFormat"}));
return undef;
@ -161,7 +161,18 @@ sub Revolt_Parse($$)
<a name="Revolt"></a>
<h3>Revolt NC-5462</h3>
<ul>
Provides voltage, current, frequency, power, pf, energy readings for Revolt NC-5462 devices via CUL.
Provides energy consumption readings for Revolt NC-5462 devices via CUL or
SIGNALduino (433MHz).
<br><br>
These devices send telegrams with measured values every few seconds. Many
users saw problems with cheap 433MHz receivers - and even with good
receivers, wrong values are received quite often, leading to outliers
in plots and sporadic autocreation of devices with wrong IDs.
<br><br>
This module now ignores implausible telegrams (e.g. voltage below 80),
but to further reduce outliers and event frequency, you should use the common
attributes described below. You also might want to disable autocreation of
Revolt devices once all of yours are detected.
<br><br>
<a name="RevoltDefine"></a>
@ -179,15 +190,30 @@ sub Revolt_Parse($$)
<li>EnergyAdjustValue: adjust the energy reading (energy = energy - EnergyAdjustValue)</li>
</ul>
<br>
<b>Common attributes</b>
<ul>
<li><a href="#event-aggregator">event-aggregator</a>: To reduce the high sending frequency and filter reception errors, you can use FHEM's event-aggregator. Common examples:
<ul>
<li><tt>power:60:linear:mean,energy:36000:none:v</tt> reduce sampling frequency to one power event per minute and one energy value per 10 hours, other events can be disabled via <tt>event-on-change-reading</tt> or <tt>event-on-update-reading</tt>.</li>
<li><tt>power::none:median:120,energy::none:median:120</tt> keep sampling frequency untouched, but filter outliers using statistical median</li>
</ul>
</li>
<li><a href="#event-min-interval">event-min-interval</a></li>
<li><a href="#event-on-change-reading">event-on-change-reading</a>: can be used to disable events for readings you don't need. See documentation for details.</li>
<li><a href="#event-on-update-reading">event-on-update-reading</a>: can be used to disable events for readings you don't need. See documentatino for details.</li>
</ul>
<a name="RevoltReadings"></a>
<b>Readings</b>
<ul>
<li>energy [kWh]</li>
<li>energy [kWh]: Total energy consumption summed up in the NC-5462
devices. It seems you can't reset this counter and it will wrap around
to 0 at 655.35 kWh. The EnergyAdjustValue attribute (see above) allows
to adapt the reading, e.g. when you connect a new device.</li>
<li>power [W]</li>
<li>voltage [V]</li>
<li>current [A]</li>
<li>frequency [Hz]</li>
<li>Pf</li>
<li>Pf: Power factor</li>
</ul>