mirror of
https://github.com/fhem/fhem-mirror.git
synced 2025-01-31 06:39:11 +00:00
76_SolarForecast: contrib 1.40.0
git-svn-id: https://svn.fhem.de/fhem/trunk@29447 2b470e98-0d58-463d-a4d8-8e2adae1ed80
This commit is contained in:
parent
fdb5498b19
commit
8012d00d3e
@ -9577,8 +9577,8 @@ sub _batChargeRecmd {
|
|||||||
|
|
||||||
for my $in (1..$maxinverter) {
|
for my $in (1..$maxinverter) {
|
||||||
$in = sprintf "%02d", $in;
|
$in = sprintf "%02d", $in;
|
||||||
my $feed = InverterVal ($hash, $in, 'ifeed', '');
|
my $feed = InverterVal ($hash, $in, 'ifeed', 'default');
|
||||||
next if(!$feed || $feed eq 'grid'); # Inverter 'Grid' ausschließen
|
next if($feed eq 'grid'); # Inverter 'Grid' ausschließen
|
||||||
|
|
||||||
my $iname = InverterVal ($hash, $in, 'iname', '');
|
my $iname = InverterVal ($hash, $in, 'iname', '');
|
||||||
my $icap = InverterVal ($hash, $in, 'invertercap', 0);
|
my $icap = InverterVal ($hash, $in, 'invertercap', 0);
|
||||||
@ -10836,7 +10836,10 @@ sub __setConsRcmdState {
|
|||||||
my ($spignore, $info, $err) = isSurplusIgnoCond ($hash, $c, $debug); # PV Überschuß ignorieren?
|
my ($spignore, $info, $err) = isSurplusIgnoCond ($hash, $c, $debug); # PV Überschuß ignorieren?
|
||||||
Log3 ($name, 1, "$name - $err") if($err);
|
Log3 ($name, 1, "$name - $err") if($err);
|
||||||
|
|
||||||
if (!$nompower || $surplus - $rescons > 0 || $spignore) {
|
if (!defined $surplus) { # $surplus kann undef sein! -> dann bisherigen isConsumptionRecommended verwenden
|
||||||
|
$data{$name}{consumers}{$c}{isConsumptionRecommended} = ReadingsVal ($name, "consumer${c}_ConsumptionRecommended", 0);
|
||||||
|
}
|
||||||
|
elsif (!$nompower || $surplus - $rescons > 0 || $spignore) {
|
||||||
$data{$name}{consumers}{$c}{isConsumptionRecommended} = 1; # Einschalten des Consumers günstig bzw. Freigabe für "on" von Überschußseite erteilt
|
$data{$name}{consumers}{$c}{isConsumptionRecommended} = 1; # Einschalten des Consumers günstig bzw. Freigabe für "on" von Überschußseite erteilt
|
||||||
}
|
}
|
||||||
else {
|
else {
|
||||||
@ -17715,7 +17718,7 @@ sub determSurplus {
|
|||||||
}
|
}
|
||||||
}
|
}
|
||||||
|
|
||||||
if (!defined $surplus || $fallback) { # Fehlerkorrektur
|
if ($fallback) { # Fall Back
|
||||||
$surplus = CurrentVal ($hash, 'surplus', 0);
|
$surplus = CurrentVal ($hash, 'surplus', 0);
|
||||||
$method = $method." but fallback to 'default'";
|
$method = $method." but fallback to 'default'";
|
||||||
}
|
}
|
||||||
@ -21434,7 +21437,7 @@ to ensure that the system configuration is correct.
|
|||||||
<tr><td> </td><td><b>default</b> - the PV surplus is read directly from the 'Current_Surplus' reading. (default) </td></tr>
|
<tr><td> </td><td><b>default</b> - the PV surplus is read directly from the 'Current_Surplus' reading. (default) </td></tr>
|
||||||
<tr><td> </td><td><b>median</b> - the median of the last PV surplus measurements (max. 20) is used. </td></tr>
|
<tr><td> </td><td><b>median</b> - the median of the last PV surplus measurements (max. 20) is used. </td></tr>
|
||||||
<tr><td> </td><td><b>2 .. 20</b> - the PV surplus used is calculated from the average of the specified number of measured values. </td></tr>
|
<tr><td> </td><td><b>2 .. 20</b> - the PV surplus used is calculated from the average of the specified number of measured values. </td></tr>
|
||||||
<tr><td> </td><td><b>Device:Reading</b> - Device/Reading combination that provides a numerical PV surplus value determined or calculated by the user. </td></tr>
|
<tr><td> </td><td><b>Device:Reading</b> - Device/Reading combination that provides a numerical PV surplus value in Watt determined or calculated by the user. </td></tr>
|
||||||
<tr><td> </td><td> </td></tr>
|
<tr><td> </td><td> </td></tr>
|
||||||
<tr><td> <b>spignorecond</b> </td><td>Condition to ignore a missing PV surplus (optional). If the condition is fulfilled, the load is switched on according to </td></tr>
|
<tr><td> <b>spignorecond</b> </td><td>Condition to ignore a missing PV surplus (optional). If the condition is fulfilled, the load is switched on according to </td></tr>
|
||||||
<tr><td> </td><td>the planning even if there is no PV surplus at the time. </td></tr>
|
<tr><td> </td><td>the planning even if there is no PV surplus at the time. </td></tr>
|
||||||
@ -23862,7 +23865,7 @@ die ordnungsgemäße Anlagenkonfiguration geprüft werden.
|
|||||||
<tr><td> </td><td><b>default</b> - der PV-Überschuß wird aus dem Reading 'Current_Surplus' direkt ausgelesen. (default) </td></tr>
|
<tr><td> </td><td><b>default</b> - der PV-Überschuß wird aus dem Reading 'Current_Surplus' direkt ausgelesen. (default) </td></tr>
|
||||||
<tr><td> </td><td><b>median</b> - es wird der Median der letzten PV-Überschuß Messungen (max. 20) verwendet. </td></tr>
|
<tr><td> </td><td><b>median</b> - es wird der Median der letzten PV-Überschuß Messungen (max. 20) verwendet. </td></tr>
|
||||||
<tr><td> </td><td><b>2 .. 20</b> - der verwendete PV-Überschuß wird als Durchschnitt der angegebenen Anzahl Meßwerte gebildet. </td></tr>
|
<tr><td> </td><td><b>2 .. 20</b> - der verwendete PV-Überschuß wird als Durchschnitt der angegebenen Anzahl Meßwerte gebildet. </td></tr>
|
||||||
<tr><td> </td><td><b>Device:Reading</b> - Device/Reading-Kombination die einen vom Nutzer bestimmten bzw. berechneten numerischen PV-Überschuß Wert liefert. </td></tr>
|
<tr><td> </td><td><b>Device:Reading</b> - Device/Reading-Kombination die einen vom Nutzer bestimmten bzw. berechneten numerischen PV-Überschuß in Watt liefert. </td></tr>
|
||||||
<tr><td> </td><td> </td></tr>
|
<tr><td> </td><td> </td></tr>
|
||||||
<tr><td> <b>spignorecond</b> </td><td>Bedingung um einen fehlenden PV Überschuß zu ignorieren (optional). Bei erfüllter Bedingung wird der Verbraucher entsprechend </td></tr>
|
<tr><td> <b>spignorecond</b> </td><td>Bedingung um einen fehlenden PV Überschuß zu ignorieren (optional). Bei erfüllter Bedingung wird der Verbraucher entsprechend </td></tr>
|
||||||
<tr><td> </td><td>der Planung eingeschaltet auch wenn zu dem Zeitpunkt kein PV Überschuß vorliegt. </td></tr>
|
<tr><td> </td><td>der Planung eingeschaltet auch wenn zu dem Zeitpunkt kein PV Überschuß vorliegt. </td></tr>
|
||||||
|