@ -1,5 +1,7 @@
###############################################################
#
# 23_LUXTRONIK2.pm
#
# Copyright notice
#
# (c) 2012,2014 Torsten Poitzsch (torsten.poitzsch@gmx.de)
@ -53,7 +55,7 @@ LUXTRONIK2_Initialize($)
$hash->{UndefFn} = "LUXTRONIK2_Undefine";
$hash->{NotifyFn} = "LUXTRONIK2_Notify";
$hash->{SetFn} = "LUXTRONIK2_Set";
$hash->{AttrFn} = "LUXTRONIK2_Attr";
$hash->{AttrFn} = "LUXTRONIK2_Attr";
$hash->{AttrList} = "disable:0,1 ".
"allowSetParameter:0,1 ".
"autoSynchClock:slider,10,5,300 ".
@ -155,10 +157,31 @@ LUXTRONIK2_Notify(@) {
if ( exists( $hash->{READINGS}{$oldReading} ) ) {
delete($hash->{READINGS}{$oldReading});
Log3 $name,2,"$name: !!! Change/fix in LUXTRONIK2-Modul: '$oldReading' is now '$newReading'";
}
}
}
}
return;
}
return;
}
sub ########################################
LUXTRONIK2_Attr(@)
{
my ($cmd,$name,$aName,$aVal) = @_;
# $cmd can be "del" or "set"
# $name is device name
# aName and aVal are Attribute name and value
if ($cmd eq "set") {
if ($aName eq "1allowSetParameter") {
eval { qr/$aVal/ };
if ($@) {
Log3 $name, 3, "LUXTRONIK2: Invalid allowSetParameter in attr $name $aName $aVal: $@";
return "Invalid allowSetParameter $aVal";
}
}
}
return undef;
}
@ -241,25 +264,6 @@ LUXTRONIK2_Set($$@)
return "Unknown argument $cmd, choose one of $list";
}
sub ########################################
LUXTRONIK2_Attr(@)
{
my ($cmd,$name,$aName,$aVal) = @_;
# $cmd can be "del" or "set"
# $name is device name
# aName and aVal are Attribute name and value
if ($cmd eq "set") {
if ($aName eq "1allowSetParameter") {
eval { qr/$aVal/ };
if ($@) {
Log3 $name, 3, "LUXTRONIK2: Invalid allowSetParameter in attr $name $aName $aVal: $@";
return "Invalid allowSetParameter $aVal";
}
}
}
return undef;
}
sub ########################################
LUXTRONIK2_GetUpdate($)
@ -296,7 +300,8 @@ LUXTRONIK2_DoUpdate($)
my $readingStartTime = time();
Log3 $name, 5, "$name: Opening connection to host ".$host;
my $socket = new IO::Socket::INET ( PeerAddr => $host,
my $socket = new IO::Socket::INET (
PeerAddr => $host,
PeerPort => 8888,
# Type = SOCK_STREAM, # probably needed on some systems
Proto => 'tcp'
@ -1270,18 +1275,19 @@ LUXTRONIK2_doStatisticBoilerCoolDown ($$$$$$)
<a name="LUXTRONIK2"></a>
<h3>LUXTRONIK2</h3>
<ul>
Luxtronik 2.0 is a heating controller used in Alpha Innotec and Siemens Novelan (WPR NET) heat pumps.<br>
Luxtronik 2.0 is a heating controller used in Alpha Innotec and Siemens Novelan (WPR NET) heat pumps.
<br>
It has a built-in ethernet port, so it can be directly integrated into a local area network (LAN).
<br>
<i>The modul is reported to work with firmware: V1.54C, V1.60, V1.69.</i>
<br>&nbsp;
<br>
&nbsp;
<br>
<a name="LUXTRONIK2define"></a>
<b>Define</b>
<ul>
<code>define &lt;name&gt; LUXTRONIK2 &lt;IP-address&gt; [poll-interval]</code>
<br>
<code>define &lt;name&gt; LUXTRONIK2 &lt;IP-address&gt; [poll-interval]</code><br>
If the pool interval is omitted, it is set to 300 (seconds). Smallest possible value is 30.
<br>
Example: <code>define Heizung LUXTRONIK2 192.168.0.12 600</code>
@ -1313,18 +1319,26 @@ LUXTRONIK2_doStatisticBoilerCoolDown ($$$$$$)
<a name="LUXTRONIK2attr"></a>
<b>Attributes</b>
<ul>
<li><code>statusHTML</code><br>
If set, a HTML-formatted reading named "floorplanHTML" is created. It can be used with the <a href="#FLOORPLAN">FLOORPLAN</a> module.<br>
Currently, if the value of this attribute is not NULL, the corresponding reading consists of the current status of the heat pump and the temperature of the water.</li>
<li><code>doStatistics &lt; 0 | 1 &gt;</code><br>
<li><code>statusHTML</code>
<br>
If set, a HTML-formatted reading named "floorplanHTML" is created. It can be used with the <a href="#FLOORPLAN">FLOORPLAN</a> module.
<br>
Currently, if the value of this attribute is not NULL, the corresponding reading consists of the current status of the heat pump and the temperature of the water.</li>
<li><code>doStatistics &lt; 0 | 1 &gt;</code>
<br>
Calculates statistic values: <i>statBoilerGradientHeatUp, statBoilerGradientCoolDown, statBoilerGradientCoolDownMin (boiler heat loss)</i></li>
<li><code>allowSetParameter &lt; 0 | 1 &gt;</code><br>
<li><code>allowSetParameter &lt; 0 | 1 &gt;</code>
<br>
The <a href="#LUXTRONIK2set">parameters</a> of the heat pump controller can only be changed if this attribut is set to 1.</li>
<li><code>autoSynchClock &lt;delay&gt;</code><br>
Corrects the clock of the heatpump automatically if a certain <i>delay</i> (10 s - 600 s) against the FHEM time is exeeded. Does a firmware check before.<br>
<li><code>autoSynchClock &lt;delay&gt;</code>
<br>
Corrects the clock of the heatpump automatically if a certain <i>delay</i> (10 s - 600 s) against the FHEM time is exeeded. Does a firmware check before.
<br>
<i>(A 'delayDeviceTimeCalc' &lt;= 2 s can be caused by the internal calculation interval of the heat pump controller.)</i></li>
<li><code>ignoreFirmwareCheck &lt; 0 | 1 &gt;</code><br>
A firmware check assures before each set operation that a heatpump controller with untested firmware is not damaged accidently.<br>
<li><code>ignoreFirmwareCheck &lt; 0 | 1 &gt;</code>
<br>
A firmware check assures before each set operation that a heatpump controller with untested firmware is not damaged accidently.
<br>
If this attribute is set to 1, the firmware check is ignored and new firmware can be tested for compatibility.</li>
<li><a href="#readingFnAttributes">readingFnAttributes</a></li>
</ul>
@ -1361,12 +1375,21 @@ LUXTRONIK2_doStatisticBoilerCoolDown ($$$$$$)
<b>Set</b><br>
<ul>
Durch einen Firmware-Test wird vor jeder Set-Operation sichergestellt, dass W&auml;rmepumpen mit ungetester Firmware nicht unabsichtlich besch&auml;digt werden.
<li>opModeHotWater &lt;Betriebsmodus&gt; - Betriebsmodus des Hei&szlig;wasserboilers ( Auto | Party | Off )</l>
<li>hotWaterTemperatureTarget &lt;Temperatur&gt; - Soll-Temperatur des Hei&szlig;wasserboilers in &deg;C</li>
<li>INTERVAL &lt;Abfrageinterval&gt; - Abfrageinterval in Sekunden</li>
<li>statusRequest - Aktualisieren der Ger&auml;tewerte</li>
<li>synchClockHeatPump - Abgleich der Uhr der Steuerung mit der FHEM Zeit. <br>
<b>!! Diese &Auml;nderung geht verloren, sobald die Steuerung ausgeschaltet wird!!</b></li>
<li><code>opModeHotWater &lt;Betriebsmodus&gt;</code>
<br>
Betriebsmodus des Hei&szlig;wasserboilers ( Auto | Party | Off )</l>
<li><code>hotWaterTemperatureTarget &lt;Temperatur&gt;</code>
<br>
Soll-Temperatur des Hei&szlig;wasserboilers in &deg;C</li>
<li><code>INTERVAL &lt;Abfrageinterval&gt;</code>
<br>
Abfrageinterval in Sekunden</li>
<li><code>statusRequest</code>
<br>
Aktualisieren der Ger&auml;tewerte</li>
<li><code>synchClockHeatPump</code>
<br>
Abgleich der Uhr der Steuerung mit der FHEM Zeit. <b>Diese &Auml;nderung geht verloren, sobald die Steuerung ausgeschaltet wird!!</b></li>
</ul>
<br>
@ -1380,17 +1403,21 @@ LUXTRONIK2_doStatisticBoilerCoolDown ($$$$$$)
<a name="LUXTRONIK2attr"></a>
<b>Attribute</b>
<ul>
<li>statusHTML<br>
<li><code>statusHTML</code><br>
wenn gesetzt, dann wird ein HTML-formatierter Wert "floorplanHTML" erzeugt, welcher vom Modul <a href="#FLOORPLAN">FLOORPLAN</a> genutzt werden kann.<br>
Momentan wird nur gepr&uuml;ft, ob der Wert dieses Attributes ungleich NULL ist, der entsprechende Ger&auml;tewerte besteht aus dem aktuellen W&auml;rmepumpenstatus und der Heizwassertemperatur.</li>
<li>doStatistics &lt; 0 | 1 &gt;<br>
Berechnet statistische Werte: <i>statBoilerGradientHeatUp, statBoilerGradientCoolDown, statBoilerGradientCoolDownMin (Wärmeverlust des Boilers)</i></li>
<li>allowSetParameter &lt; 0 | 1 &gt;<br>
Die internen <a href="#LUXTRONIK2set">Parameter</a> der W&auml;rmepumpensteuerung k&ouml;nnen nur ge&auml;ndert werden, wenn dieses Attribut auf 1 gesetzt ist.</li>
<li>autoSynchClock &lt;Zeitunterschied&gt;<br>
<li><code>doStatistics &lt; 0 | 1 &gt;</code>
<br>
Berechnet statistische Werte: <i>statBoilerGradientHeatUp, statBoilerGradientCoolDown, statBoilerGradientCoolDownMin (W&auml;rmeverlust des Boilers)</i></li>
<li><code>allowSetParameter &lt; 0 | 1 &gt;</code>
<br>
Die internen <a href="#LUXTRONIK2set">Parameter</a> der W&auml;rmepumpensteuerung k&ouml;nnen nur ge&auml;ndert werden, wenn dieses Attribut auf 1 gesetzt ist.</li>
<li><code>autoSynchClock &lt;Zeitunterschied&gt;</code>
<br>
Die Uhr der W&auml;rmepumpe wird automatisch korrigiert, wenn ein gewisser <i>Zeitunterschied</i> (10 s - 600 s) gegen&uuml;ber der FHEM Zeit erreicht ist. Zuvor wird die Kompatibilit&auml;t der Firmware &uuml;berpr&uuml;ft.<br>
<i>(Ein Ger&auml;tewert 'delayDeviceTimeCalc' &lt;= 2 s ist auf die internen Berechnungsintervale der W&auml;rmepumpensteuerung zur&uuml;ckzuf&uuml;hren.)</i></li>
<li>ignoreFirmwareCheck &lt; 0 | 1 &gt;<br>
<li><code>ignoreFirmwareCheck &lt; 0 | 1 &gt;</code>
<br>
Durch einen Firmware-Test wird vor jeder Set-Operation sichergestellt, dass W&auml;rmepumpen mit ungetester Firmware nicht unabsichtlich besch&auml;digt werden. Wenn dieses Attribute auf 1 gesetzt ist, dann wird der Firmware-Test ignoriert und neue Firmware kann getestet werden. Dieses Attribut wird jedoch ignoriert, wenn die Steuerungs-Firmware bereits als nicht kompatibel berichtet wurde.</li>