76_SolarForecast: rename reset arguments according possible adjustable textField width
git-svn-id: https://svn.fhem.de/fhem/trunk@28202 2b470e98-0d58-463d-a4d8-8e2adae1ed80
This commit is contained in:
parent
dc78f5e297
commit
7bce7e3958
@ -150,6 +150,7 @@ BEGIN {
|
||||
|
||||
# Versions History intern
|
||||
my %vNotesIntern = (
|
||||
"1.1.3" => "24.11.2023 rename reset arguments according possible adjustable textField width ",
|
||||
"1.1.2" => "20.11.2023 ctrlDebug Adjustment of column width, must have new fhemweb.js Forum:#135850 ",
|
||||
"1.1.1" => "19.11.2023 graphicHeaderOwnspec: fix ignoring the last element of allsets/allattr ",
|
||||
"1.1.0" => "14.11.2023 graphicHeaderOwnspec: possible add set/attr commands, new setter consumerNewPlanning ",
|
||||
@ -1277,14 +1278,13 @@ sub Set {
|
||||
consumerMaster
|
||||
consumerPlanning
|
||||
consumption
|
||||
currentBatteryDev
|
||||
currentWeatherDev
|
||||
currentInverterDev
|
||||
currentMeterDev
|
||||
energyH4Trigger
|
||||
inverterStrings
|
||||
moduleRoofTops
|
||||
powerTrigger
|
||||
currentBatterySet
|
||||
currentInverterSet
|
||||
currentMeterSet
|
||||
energyH4TriggerSet
|
||||
inverterStringSet
|
||||
moduleRoofTopSet
|
||||
powerTriggerSet
|
||||
pvCorrection
|
||||
roofIdentPair
|
||||
pvHistory
|
||||
@ -2252,21 +2252,21 @@ sub _setreset { ## no critic "not used"
|
||||
return;
|
||||
}
|
||||
|
||||
if ($prop eq 'powerTrigger') {
|
||||
if ($prop eq 'powerTriggerSet') {
|
||||
deleteReadingspec ($hash, "powerTrigger.*");
|
||||
writeCacheToFile ($hash, "plantconfig", $plantcfg.$name); # Anlagenkonfiguration File schreiben
|
||||
writeCacheToFile ($hash, "plantconfig", $plantcfg.$name); # Anlagenkonfiguration File schreiben
|
||||
return;
|
||||
}
|
||||
|
||||
if ($prop eq 'energyH4Trigger') {
|
||||
if ($prop eq 'energyH4TriggerSet') {
|
||||
deleteReadingspec ($hash, "energyH4Trigger.*");
|
||||
writeCacheToFile ($hash, "plantconfig", $plantcfg.$name); # Anlagenkonfiguration File schreiben
|
||||
writeCacheToFile ($hash, "plantconfig", $plantcfg.$name);
|
||||
return;
|
||||
}
|
||||
|
||||
if ($prop eq 'moduleRoofTops') {
|
||||
if ($prop eq 'moduleRoofTopSet') {
|
||||
deleteReadingspec ($hash, "moduleRoofTops");
|
||||
writeCacheToFile ($hash, "plantconfig", $plantcfg.$name); # Anlagenkonfiguration File schreiben
|
||||
writeCacheToFile ($hash, "plantconfig", $plantcfg.$name);
|
||||
return;
|
||||
}
|
||||
|
||||
@ -2288,7 +2288,7 @@ sub _setreset { ## no critic "not used"
|
||||
return;
|
||||
}
|
||||
|
||||
if ($prop eq 'currentMeterDev') {
|
||||
if ($prop eq 'currentMeterSet') {
|
||||
readingsDelete ($hash, "Current_GridConsumption");
|
||||
readingsDelete ($hash, "Current_GridFeedIn");
|
||||
delete $data{$type}{$name}{circular}{'99'}{initdayfeedin};
|
||||
@ -2306,7 +2306,7 @@ sub _setreset { ## no critic "not used"
|
||||
writeCacheToFile ($hash, "plantconfig", $plantcfg.$name); # Anlagenkonfiguration File schreiben
|
||||
}
|
||||
|
||||
if ($prop eq 'currentBatteryDev') {
|
||||
if ($prop eq 'currentBatterySet') {
|
||||
readingsDelete ($hash, "Current_PowerBatIn");
|
||||
readingsDelete ($hash, "Current_PowerBatOut");
|
||||
readingsDelete ($hash, "Current_BatCharge");
|
||||
@ -2321,7 +2321,7 @@ sub _setreset { ## no critic "not used"
|
||||
writeCacheToFile ($hash, "plantconfig", $plantcfg.$name); # Anlagenkonfiguration File schreiben
|
||||
}
|
||||
|
||||
if ($prop eq 'currentInverterDev') {
|
||||
if ($prop eq 'currentInverterSet') {
|
||||
readingsDelete ($hash, "Current_PV");
|
||||
deleteReadingspec ($hash, ".*_PVreal" );
|
||||
writeCacheToFile ($hash, "plantconfig", $plantcfg.$name); # Anlagenkonfiguration File schreiben
|
||||
@ -15066,13 +15066,12 @@ to ensure that the system configuration is correct.
|
||||
<tr><td> </td><td><ul>set <name> reset consumption <Day> (e.g. set <name> reset consumption 08) </ul> </td></tr>
|
||||
<tr><td> </td><td>To delete the consumption values of a specific hour of a day: </td></tr>
|
||||
<tr><td> </td><td><ul>set <name> reset consumption <Day> <Hour> (e.g. set <name> reset consumption 08 10) </ul> </td></tr>
|
||||
<tr><td> <b>currentBatteryDev</b> </td><td>deletes the set battery device and corresponding data. </td></tr>
|
||||
<tr><td> <b>currentWeatherDev</b> </td><td>deletes the set device for weather data </td></tr>
|
||||
<tr><td> <b>currentInverterDev</b> </td><td>deletes the set inverter device and corresponding data. </td></tr>
|
||||
<tr><td> <b>currentMeterDev</b> </td><td>deletes the set meter device and corresponding data. </td></tr>
|
||||
<tr><td> <b>energyH4Trigger</b> </td><td>deletes the 4-hour energy trigger points </td></tr>
|
||||
<tr><td> <b>inverterStrings</b> </td><td>deletes the string configuration of the installation </td></tr>
|
||||
<tr><td> <b>powerTrigger</b> </td><td>deletes the trigger points for PV generation values </td></tr>
|
||||
<tr><td> <b>currentBatterySet</b> </td><td>deletes the set battery device and corresponding data. </td></tr>
|
||||
<tr><td> <b>currentInverterSet</b> </td><td>deletes the set inverter device and corresponding data. </td></tr>
|
||||
<tr><td> <b>currentMeterSet</b> </td><td>deletes the set meter device and corresponding data. </td></tr>
|
||||
<tr><td> <b>energyH4TriggerSet</b> </td><td>deletes the 4-hour energy trigger points </td></tr>
|
||||
<tr><td> <b>inverterStringSet</b> </td><td>deletes the string configuration of the installation </td></tr>
|
||||
<tr><td> <b>powerTriggerSet</b> </td><td>deletes the trigger points for PV generation values </td></tr>
|
||||
<tr><td> <b>pvCorrection</b> </td><td>deletes the readings pvCorrectionFactor* </td></tr>
|
||||
<tr><td> </td><td>To delete all previously stored PV correction factors from the caches: </td></tr>
|
||||
<tr><td> </td><td><ul>set <name> reset pvCorrection cached </ul> </td></tr>
|
||||
@ -15084,7 +15083,7 @@ to ensure that the system configuration is correct.
|
||||
<tr><td> </td><td><ul>set <name> reset pvHistory <Day> (e.g. set <name> reset pvHistory 08) </ul> </td></tr>
|
||||
<tr><td> </td><td>To delete a specific hour of a historical day: </td></tr>
|
||||
<tr><td> </td><td><ul>set <name> reset pvHistory <Day> <Hour> (e.g. set <name> reset pvHistory 08 10) </ul> </td></tr>
|
||||
<tr><td> <b>moduleRoofTops</b> </td><td>deletes the SolCast API Rooftops </td></tr>
|
||||
<tr><td> <b>moduleRoofTopSet</b> </td><td>deletes the SolCast API Rooftops </td></tr>
|
||||
<tr><td> <b>roofIdentPair</b> </td><td>deletes all saved SolCast API Rooftop ID / API Key pairs. </td></tr>
|
||||
<tr><td> </td><td>To delete a specific pair, specify its key <pk>: </td></tr>
|
||||
<tr><td> </td><td><ul>set <name> reset roofIdentPair <pk> (e.g. set <name> reset roofIdentPair p1) </ul> </td></tr>
|
||||
@ -16942,13 +16941,12 @@ die ordnungsgemäße Anlagenkonfiguration geprüft werden.
|
||||
<tr><td> </td><td><ul>set <name> reset consumption <Tag> (z.B. set <name> reset consumption 08) </ul> </td></tr>
|
||||
<tr><td> </td><td>Um die Verbrauchswerte einer bestimmten Stunde eines Tages zu löschen: </td></tr>
|
||||
<tr><td> </td><td><ul>set <name> reset consumption <Tag> <Stunde> (z.B. set <name> reset consumption 08 10) </ul> </td></tr>
|
||||
<tr><td> <b>currentBatteryDev</b> </td><td>löscht das eingestellte Batteriedevice und korrespondierende Daten </td></tr>
|
||||
<tr><td> <b>currentWeatherDev</b> </td><td>löscht das eingestellte Device für Wetterdaten </td></tr>
|
||||
<tr><td> <b>currentInverterDev</b> </td><td>löscht das eingestellte Inverterdevice und korrespondierende Daten </td></tr>
|
||||
<tr><td> <b>currentMeterDev</b> </td><td>löscht das eingestellte Meterdevice und korrespondierende Daten </td></tr>
|
||||
<tr><td> <b>energyH4Trigger</b> </td><td>löscht die 4-Stunden Energie Triggerpunkte </td></tr>
|
||||
<tr><td> <b>inverterStrings</b> </td><td>löscht die Stringkonfiguration der Anlage </td></tr>
|
||||
<tr><td> <b>powerTrigger</b> </td><td>löscht die Triggerpunkte für PV Erzeugungswerte </td></tr>
|
||||
<tr><td> <b>currentBatterySet</b> </td><td>löscht das eingestellte Batteriedevice und korrespondierende Daten </td></tr>
|
||||
<tr><td> <b>currentInverterSet</b> </td><td>löscht das eingestellte Inverterdevice und korrespondierende Daten </td></tr>
|
||||
<tr><td> <b>currentMeterSet</b> </td><td>löscht das eingestellte Meterdevice und korrespondierende Daten </td></tr>
|
||||
<tr><td> <b>energyH4TriggerSet</b> </td><td>löscht die 4-Stunden Energie Triggerpunkte </td></tr>
|
||||
<tr><td> <b>inverterStringSet</b> </td><td>löscht die Stringkonfiguration der Anlage </td></tr>
|
||||
<tr><td> <b>powerTriggerSet</b> </td><td>löscht die Triggerpunkte für PV Erzeugungswerte </td></tr>
|
||||
<tr><td> <b>pvCorrection</b> </td><td>löscht die Readings pvCorrectionFactor* </td></tr>
|
||||
<tr><td> </td><td>Um alle bisher gespeicherten PV Korrekturfaktoren aus den Caches zu löschen: </td></tr>
|
||||
<tr><td> </td><td><ul>set <name> reset pvCorrection cached </ul> </td></tr>
|
||||
@ -16960,7 +16958,7 @@ die ordnungsgemäße Anlagenkonfiguration geprüft werden.
|
||||
<tr><td> </td><td><ul>set <name> reset pvHistory <Tag> (z.B. set <name> reset pvHistory 08) </ul> </td></tr>
|
||||
<tr><td> </td><td>Um eine bestimmte Stunde eines historischer Tages zu löschen: </td></tr>
|
||||
<tr><td> </td><td><ul>set <name> reset pvHistory <Tag> <Stunde> (z.B. set <name> reset pvHistory 08 10) </ul> </td></tr>
|
||||
<tr><td> <b>moduleRoofTops</b> </td><td>löscht die SolCast API Rooftops </td></tr>
|
||||
<tr><td> <b>moduleRoofTopSet</b> </td><td>löscht die SolCast API Rooftops </td></tr>
|
||||
<tr><td> <b>roofIdentPair</b> </td><td>löscht alle gespeicherten SolCast API Rooftop-ID / API-Key Paare </td></tr>
|
||||
<tr><td> </td><td>Um ein bestimmtes Paar zu löschen ist dessen Schlüssel <pk> anzugeben: </td></tr>
|
||||
<tr><td> </td><td><ul>set <name> reset roofIdentPair <pk> (z.B. set <name> reset roofIdentPair p1) </ul> </td></tr>
|
||||
|
Loading…