mirror of
https://github.com/fhem/fhem-mirror.git
synced 2025-04-04 17:08:43 +00:00
76_SolarForecast: contrib 1.49.0
git-svn-id: https://svn.fhem.de/fhem/trunk@29773 2b470e98-0d58-463d-a4d8-8e2adae1ed80
This commit is contained in:
parent
14f2da8bb2
commit
7a04113e01
@ -165,7 +165,7 @@ my %vNotesIntern = (
|
||||
"set reset aiData deletes raw data also, _transferAPIRadiationValues: AI PV estimate limited to inverter capacity summary ".
|
||||
"__calcPVestimates: pv power summary of all strings connected to inverter limited to inverter capacity summary ".
|
||||
"_batChargeRecmd: fix calc if more than one batteries are installed, set aiDecTree: new option rawDataGHIreplace ".
|
||||
"new Attr plantControl with key feedinPowerLimit ",
|
||||
"new Attr plantControl with key feedinPowerLimit, batteryPreferredCharge , Attr affectBatteryPreferredCharge is obsolete ",
|
||||
"1.48.0" => "14.03.2025 edit commandref, add graphicBeam layer 5 and 6, attr ctrlAIdataStorageDuration, ctrlAIshiftTrainStart removed ",
|
||||
"1.47.3" => "11.03.2025 adjust weather_ids and management of significant weather, _calcDataEveryFullHour: change attrInvChangedTs Management ".
|
||||
"split __batteryOnBeam into _beamFillupBatValues and itself, expand bat key 'show' by top, bottom ".
|
||||
@ -567,7 +567,7 @@ my @rconfigs = qw( pvCorrectionFactor_Auto
|
||||
energyH4Trigger
|
||||
);
|
||||
# Anlagenkonfiguration: maßgebliche Attribute
|
||||
my @aconfigs = qw( affectBatteryPreferredCharge affectConsForecastIdentWeekdays
|
||||
my @aconfigs = qw( affectConsForecastIdentWeekdays
|
||||
affectConsForecastInPlanning affectSolCastPercentile
|
||||
aiControl
|
||||
consumerLegend consumerAdviceIcon consumerLink
|
||||
@ -1527,8 +1527,7 @@ sub Initialize {
|
||||
$hash->{AttrFn} = \&Attr;
|
||||
$hash->{NotifyFn} = \&Notify;
|
||||
$hash->{ReadyFn} = \&runTask;
|
||||
$hash->{AttrList} = "affectBatteryPreferredCharge:slider,0,1,100 ".
|
||||
"affectConsForecastIdentWeekdays:1,0 ".
|
||||
$hash->{AttrList} = "affectConsForecastIdentWeekdays:1,0 ".
|
||||
"affectConsForecastInPlanning:1,0 ".
|
||||
"affectConsForecastLastDays:selectnumbers,1,1,180,0,lin ".
|
||||
"affectSolCastPercentile:select,10,50,90 ".
|
||||
@ -1594,8 +1593,8 @@ sub Initialize {
|
||||
|
||||
### nicht mehr benötigte Daten verarbeiten - Bereich kann später wieder raus !!
|
||||
##########################################################################################################################
|
||||
# my $av = 'obsolete#-#use#attr#flowGraphicControl#instead'; # 07.03.2025
|
||||
# $hash->{AttrList} .= " ctrlAIdataStorageDuration:$av ctrlAIshiftTrainStart:$av ";
|
||||
my $av = 'obsolete#-#use#attr#plantControl#instead';
|
||||
$hash->{AttrList} .= " affectBatteryPreferredCharge:$av "; # 21.03.2025
|
||||
##########################################################################################################################
|
||||
|
||||
$hash->{FW_hideDisplayName} = 1; # Forum 88667
|
||||
@ -5875,17 +5874,16 @@ sub Attr {
|
||||
|
||||
### nicht mehr benötigte Daten verarbeiten - Bereich kann später wieder raus !!
|
||||
######################################################################################################################
|
||||
#if ($cmd eq 'set' && $aName =~ /^ctrlAIdataStorageDuration|ctrlAIshiftTrainStart$/) {
|
||||
# #my $msg = "The attribute $aName is obsolete and will be deleted soon. Please save your Configuration.";
|
||||
# my $msg = "The attribute $aName is replaced by 'aiControl'. Please press 'save config' when restart is finished.";
|
||||
# if (!$init_done) {
|
||||
# Log3 ($name, 1, "$name - $msg");
|
||||
# #return qq{Device "$name" -> $msg};
|
||||
# }
|
||||
# else {
|
||||
# return $msg;
|
||||
# }
|
||||
#}
|
||||
if ($cmd eq 'set' && $aName =~ /^affectBatteryPreferredCharge$/) { # 21.03.2025
|
||||
#my $msg = "The attribute $aName is obsolete and will be deleted soon. Please press 'save config' when restart is finished.";
|
||||
my $msg = "The attribute $aName is replaced by 'plantControl'.";
|
||||
if (!$init_done) {
|
||||
Log3 ($name, 1, "$name - $msg");
|
||||
}
|
||||
else {
|
||||
return $msg;
|
||||
}
|
||||
}
|
||||
######################################################################################################################
|
||||
|
||||
if ($aName eq 'disable') {
|
||||
@ -6352,6 +6350,7 @@ sub _attrplantControl { ## no critic "not used"
|
||||
my $hash = $defs{$name};
|
||||
|
||||
for my $av ( qw( feedinPowerLimit
|
||||
batteryPreferredCharge
|
||||
) ) {
|
||||
|
||||
delete $data{$name}{current}{$av};
|
||||
@ -6359,7 +6358,8 @@ sub _attrplantControl { ## no critic "not used"
|
||||
|
||||
if ($cmd eq 'set') {
|
||||
my $valid = {
|
||||
feedinPowerLimit => '\d+',
|
||||
feedinPowerLimit => '\d+',
|
||||
batteryPreferredCharge => '([0-9]|[1-9][0-9]|100)',
|
||||
};
|
||||
|
||||
my ($a, $h) = parseParams ($aVal);
|
||||
@ -7979,7 +7979,17 @@ sub centralTask {
|
||||
##########################################################################################################################
|
||||
#delete $data{$name}{circular}{'00'}; # 04.02.2025
|
||||
readingsDelete ($hash, '.migrated'); # 01.02.25
|
||||
|
||||
my $pcb = AttrVal ($name, 'affectBatteryPreferredCharge', undef); # 22.03.2025
|
||||
::CommandDeleteAttr (undef, "$name affectBatteryPreferredCharge") if(defined $pcb);
|
||||
my $apc = AttrVal ($name, 'plantControl', '');
|
||||
|
||||
if (defined $pcb) {
|
||||
my $newval = $apc." batteryPreferredCharge=$pcb" if(defined $pcb);
|
||||
CommandAttr (undef, "$name plantControl $newval");
|
||||
}
|
||||
######
|
||||
|
||||
my $n = 0; # 01.02.25 -> Datenmigration pvrlsum, pvfcsum, dnumsum in pvrl_*, pvfc_*
|
||||
for my $hh (1..24) {
|
||||
$hh = sprintf "%02d", $hh;
|
||||
@ -10475,9 +10485,9 @@ sub _batChargeRecmd {
|
||||
return if(!isBatteryUsed ($name));
|
||||
|
||||
my $hash = $defs{$name};
|
||||
my $pvCu = ReadingsNum ($name, 'Current_PV', 0); # aktuelle PV Erzeugung
|
||||
my $curcon = ReadingsNum ($name, 'Current_Consumption', 0); # aktueller Verbrauch
|
||||
my $feedinlim = CurrentVal ($name, 'feedinPowerLimit', INFINIITY); # Einspeiselimit in W
|
||||
my $pvCu = ReadingsNum ($name, 'Current_PV', 0); # aktuelle PV Erzeugung
|
||||
my $curcon = ReadingsNum ($name, 'Current_Consumption', 0); # aktueller Verbrauch
|
||||
my $feedinlim = CurrentVal ($name, 'feedinPowerLimit', INFINIITY); # Einspeiselimit in W
|
||||
my $inplim = 0;
|
||||
|
||||
## Inverter Limits ermitteln
|
||||
@ -12412,14 +12422,13 @@ sub ___enableSwitchByBatPrioCharge {
|
||||
my $name = $paref->{name};
|
||||
my $c = $paref->{consumer};
|
||||
|
||||
my $hash = $defs{$name};
|
||||
my $ena = 1;
|
||||
my $pcb = AttrVal ($name, 'affectBatteryPreferredCharge', 0); # Vorrangladung Batterie zu X%
|
||||
my $pcb = CurrentVal ($name, 'affectBatteryPreferredCharge', 0); # Vorrangladung Batterie zu X%
|
||||
my ($badev) = isBatteryUsed ($name);
|
||||
|
||||
return $ena if(!$pcb || !$badev); # Freigabe Schalten Consumer wenn kein Prefered Battery/Soll-Ladung 0 oder keine Batterie installiert
|
||||
|
||||
my $bcharge = BatteryVal ($hash, '01', 'bcharge', 0); # aktuelle Ladung in %
|
||||
my $bcharge = BatteryVal ($name, '01', 'bcharge', 0); # aktuelle Ladung in %
|
||||
$ena = 0 if($bcharge < $pcb); # keine Freigabe wenn Batterieladung kleiner Soll-Ladung
|
||||
|
||||
return $ena;
|
||||
@ -23905,15 +23914,6 @@ to ensure that the system configuration is correct.
|
||||
<br><br>
|
||||
<ul>
|
||||
<ul>
|
||||
<a id="SolarForecast-attr-affectBatteryPreferredCharge"></a>
|
||||
<li><b>affectBatteryPreferredCharge </b><br>
|
||||
Consumers with the <b>can</b> mode are only switched on when the specified battery charge (%)
|
||||
is reached. <br>
|
||||
Consumers with the <b>must</b> mode do not observe the priority charging of the battery. <br>
|
||||
(default: 0)
|
||||
</li>
|
||||
<br>
|
||||
|
||||
<a id="SolarForecast-attr-affectConsForecastInPlanning"></a>
|
||||
<li><b>affectConsForecastInPlanning </b><br>
|
||||
If set, the consumption forecast is also taken into account in addition to the PV forecast when scheduling the
|
||||
@ -24901,12 +24901,16 @@ to ensure that the system configuration is correct.
|
||||
|
||||
<ul>
|
||||
<table>
|
||||
<colgroup> <col width="35%"> <col width="65%"> </colgroup>
|
||||
<tr><td> <b>feedinPowerLimit</b> </td><td>Feed-in limit of the entire system into the public grid in watts. </td></tr>
|
||||
<tr><td> </td><td>SolarForecast does not limit the feed-in, but uses this information </td></tr>
|
||||
<tr><td> </td><td>within the battery charge management to avoid system curtailment. </td></tr>
|
||||
<tr><td> </td><td>Value: <b>Integer</b>, default: unlimited </td></tr>
|
||||
<tr><td> </td><td> </td></tr>
|
||||
<colgroup> <col width="20%"> <col width="80%"> </colgroup>
|
||||
<tr><td> <b>batteryPreferredCharge</b> </td><td>Consumers with the <b>can</b> mode are only switched on when the specified battery charge (%) is reached. </td></tr>
|
||||
<tr><td> </td><td>Consumers with the <b>must</b> mode do not observe the priority charging of the battery. </td></tr>
|
||||
<tr><td> </td><td>Wert: <b>Integer 0..100</b>, default: 0 </td></tr>
|
||||
<tr><td> </td><td> </td></tr>
|
||||
<tr><td> <b>feedinPowerLimit</b> </td><td>Feed-in limit of the entire system into the public grid in watts. </td></tr>
|
||||
<tr><td> </td><td>SolarForecast does not limit the feed-in, but uses this information </td></tr>
|
||||
<tr><td> </td><td>within the battery charge management to avoid system curtailment. </td></tr>
|
||||
<tr><td> </td><td>Value: <b>Integer</b>, default: unlimited </td></tr>
|
||||
<tr><td> </td><td> </td></tr>
|
||||
</table>
|
||||
</ul>
|
||||
|
||||
@ -26436,15 +26440,6 @@ die ordnungsgemäße Anlagenkonfiguration geprüft werden.
|
||||
<br><br>
|
||||
<ul>
|
||||
<ul>
|
||||
<a id="SolarForecast-attr-affectBatteryPreferredCharge"></a>
|
||||
<li><b>affectBatteryPreferredCharge </b><br>
|
||||
Es werden Verbraucher mit dem Mode <b>can</b> erst dann eingeschaltet, wenn die angegebene Batterieladung (%)
|
||||
erreicht ist. <br>
|
||||
Verbraucher mit dem Mode <b>must</b> beachten die Vorrangladung der Batterie nicht. <br>
|
||||
(default: 0)
|
||||
</li>
|
||||
<br>
|
||||
|
||||
<a id="SolarForecast-attr-affectConsForecastInPlanning"></a>
|
||||
<li><b>affectConsForecastInPlanning </b><br>
|
||||
Wenn gesetzt, wird bei der Einplanung der Consumer zusätzlich zur PV Prognose ebenfalls die Prognose
|
||||
@ -27430,12 +27425,16 @@ die ordnungsgemäße Anlagenkonfiguration geprüft werden.
|
||||
|
||||
<ul>
|
||||
<table>
|
||||
<colgroup> <col width="35%"> <col width="65%"> </colgroup>
|
||||
<tr><td> <b>feedinPowerLimit</b> </td><td>Einspeiselimit der Gesamtanlage in das öffentliche Netz in Watt. </td></tr>
|
||||
<tr><td> </td><td>SolarForecast limitiert die Einspeisung nicht, verwendet diese Angabe jedoch </td></tr>
|
||||
<tr><td> </td><td>innerhalb des Batterie-Lademanagements zur Vermeidung einer Anlagenabregelung. </td></tr>
|
||||
<tr><td> </td><td>Wert: <b>Ganzzahl</b>, default: unbegrent </td></tr>
|
||||
<tr><td> </td><td> </td></tr>
|
||||
<colgroup> <col width="20%"> <col width="80%"> </colgroup>
|
||||
<tr><td> <b>batteryPreferredCharge</b> </td><td>Verbraucher mit dem Mode <b>can</b> werden erst dann eingeschaltet, wenn die angegebene Batterieladung (%) erreicht ist. </td></tr>
|
||||
<tr><td> </td><td>Verbraucher mit dem Mode <b>must</b> beachten die Vorrangladung der Batterie nicht. </td></tr>
|
||||
<tr><td> </td><td>Wert: <b>Ganzzahl 0..100</b>, default: 0 </td></tr>
|
||||
<tr><td> </td><td> </td></tr>
|
||||
<tr><td> <b>feedinPowerLimit</b> </td><td>Einspeiselimit der Gesamtanlage in das öffentliche Netz in Watt. </td></tr>
|
||||
<tr><td> </td><td>SolarForecast limitiert die Einspeisung nicht, verwendet diese Angabe jedoch </td></tr>
|
||||
<tr><td> </td><td>innerhalb des Batterie-Lademanagements zur Vermeidung einer Anlagenabregelung. </td></tr>
|
||||
<tr><td> </td><td>Wert: <b>Ganzzahl</b>, default: unbegrent </td></tr>
|
||||
<tr><td> </td><td> </td></tr>
|
||||
</table>
|
||||
</ul>
|
||||
|
||||
|
Loading…