mirror of
https://github.com/fhem/fhem-mirror.git
synced 2024-12-22 09:41:51 +00:00
76_SolarForecast: improve Bat careSoC management when dark doldrums
git-svn-id: https://svn.fhem.de/fhem/trunk@29443 2b470e98-0d58-463d-a4d8-8e2adae1ed80
This commit is contained in:
parent
17d9740c12
commit
7738d76a70
@ -1,5 +1,6 @@
|
||||
# Add changes at the top of the list. Keep it in ASCII, and 80-char wide.
|
||||
# Do not insert empty lines here, update check depends on it
|
||||
- change: 76_SolarForecast: improve Bat careSoC management when dark doldrums
|
||||
- change: 76_SolarForecast: prepare for further development
|
||||
- bugfix: 88_HMCCU: Fixed Winmatic lock command
|
||||
- bugfix: 76_SolarForecast: batteryManagement - fix care SoC management
|
||||
|
@ -158,6 +158,7 @@ BEGIN {
|
||||
|
||||
# Versions History intern
|
||||
my %vNotesIntern = (
|
||||
"1.39.8" => "21.12.2024 prepare of new consumer key 'surpmeth', _batSocTarget: improve care SoC management when dark doldrums ",
|
||||
"1.39.7" => "18.12.2024 ConsumptionRecommended calc method medianArray, change local owndata to global data ",
|
||||
"1.39.6" => "17.12.2024 replace global data-store by local owndata-store, remove sub _composeRemoteObj, delHashRefDeep removed ".
|
||||
"add current key (array) 'surplusslidereg' + sub avgArray, batteryManagement: fix care SoC management ",
|
||||
@ -5427,7 +5428,7 @@ sub _attrconsumer { ## no critic "not used"
|
||||
if (exists $h->{mode} && $h->{mode} !~ /^(?:can|must)$/xs) {
|
||||
if ($h->{mode} =~ /.*:.*/xs) {
|
||||
my ($dv, $rd) = split ':', $h->{mode};
|
||||
($err) = isDeviceValid ( { name => $hash->{NAME}, obj => $dv, method => 'string' } );
|
||||
($err) = isDeviceValid ( { name => $name, obj => $dv, method => 'string' } );
|
||||
return $err if($err);
|
||||
|
||||
my $mode = ReadingsVal ($dv, $rd, '');
|
||||
@ -5439,6 +5440,21 @@ sub _attrconsumer { ## no critic "not used"
|
||||
return qq{The mode "$h->{mode}" isn't allowed!};
|
||||
}
|
||||
}
|
||||
|
||||
if (exists $h->{surpmeth}) {
|
||||
if ($h->{surpmeth} =~ /.*:.*/xs) {
|
||||
my ($dv, $rd) = split ':', $h->{surpmeth};
|
||||
($err) = isDeviceValid ( { name => $name, obj => $dv, method => 'string' } );
|
||||
return $err if($err);
|
||||
|
||||
if (!isNumeric( ReadingsVal ($dv, $rd, '') )) {
|
||||
return "The reading '$rd' of device '$dv' is invalid or doesn't contain a valid numeric value";
|
||||
}
|
||||
}
|
||||
elsif ($h->{surpmeth} !~ /^[1-9]$|^1[0-9]$|^20$|^median$/xs) {
|
||||
return qq{The surpmeth "$h->{surpmeth}" is wrong. It must contain a '<device>:<reading>', 'median' or integer value '1 .. 20'.};
|
||||
}
|
||||
}
|
||||
|
||||
my $valid;
|
||||
|
||||
@ -7605,7 +7621,7 @@ sub _collectAllRegConsumers {
|
||||
}
|
||||
|
||||
my $interruptable = 0;
|
||||
my ($hyst);
|
||||
my $hyst;
|
||||
if (exists $hc->{interruptable} && $hc->{interruptable} ne '0') {
|
||||
$interruptable = $hc->{interruptable};
|
||||
($interruptable,$hyst) = $interruptable =~ /(.*):(.*)$/xs if($interruptable ne '1');
|
||||
@ -7626,7 +7642,7 @@ sub _collectAllRegConsumers {
|
||||
my $clt;
|
||||
if (exists $hc->{locktime}) {
|
||||
$clt = $hc->{locktime};
|
||||
}
|
||||
}
|
||||
|
||||
delete $data{$name}{consumers}{$c}{sunriseshift};
|
||||
delete $data{$name}{consumers}{$c}{sunsetshift};
|
||||
@ -7658,6 +7674,7 @@ sub _collectAllRegConsumers {
|
||||
$data{$name}{consumers}{$c}{asynchron} = $asynchron // 0; # Arbeitsweise FHEM Consumer Device
|
||||
$data{$name}{consumers}{$c}{noshow} = $noshow // 0; # ausblenden in Grafik
|
||||
$data{$name}{consumers}{$c}{exconfc} = $exconfc // 0; # Verbrauch von Erstelleung der Verbrauchsprognose ausschließen
|
||||
$data{$name}{consumers}{$c}{surpmeth} = $hc->{surpmeth} // 1; # Ermittlungsmethode des PV-Überschusses, default=1 -> direkte Messung
|
||||
$data{$name}{consumers}{$c}{locktime} = $clt // '0:0'; # Sperrzeit im Automatikmodus ('offlt:onlt')
|
||||
$data{$name}{consumers}{$c}{onreg} = $onreg // 'on'; # Regex für 'ein'
|
||||
$data{$name}{consumers}{$c}{offreg} = $offreg // 'off'; # Regex für 'aus'
|
||||
@ -7672,9 +7689,9 @@ sub _collectAllRegConsumers {
|
||||
$data{$name}{consumers}{$c}{spignorecondregex} = $spignorecondregex // q{}; # Regex der Ignore Bedingung
|
||||
$data{$name}{consumers}{$c}{interruptable} = $interruptable; # Ein-Zustand des Verbrauchers ist unterbrechbar
|
||||
$data{$name}{consumers}{$c}{hysteresis} = $hyst // $defhyst; # Hysterese
|
||||
$data{$name}{consumers}{$c}{sunriseshift} = $riseshift if(defined $riseshift); # Verschiebung (Sekunden) Sonnenaufgang bei SunPath Verwendung
|
||||
$data{$name}{consumers}{$c}{sunsetshift} = $setshift if(defined $setshift); # Verschiebung (Sekunden) Sonnenuntergang bei SunPath Verwendung
|
||||
$data{$name}{consumers}{$c}{icon} = $hc->{icon} if(defined $hc->{icon}); # Icon für den Verbraucher
|
||||
$data{$name}{consumers}{$c}{sunriseshift} = $riseshift if(defined $riseshift); # Verschiebung (Sekunden) Sonnenaufgang bei SunPath Verwendung
|
||||
$data{$name}{consumers}{$c}{sunsetshift} = $setshift if(defined $setshift); # Verschiebung (Sekunden) Sonnenuntergang bei SunPath Verwendung
|
||||
$data{$name}{consumers}{$c}{icon} = $hc->{icon} if(defined $hc->{icon}); # Icon für den Verbraucher
|
||||
}
|
||||
|
||||
$data{$name}{current}{consumerCollected} = 1;
|
||||
@ -9364,7 +9381,7 @@ sub _batSocTarget {
|
||||
my $batcharge = CurrentVal ($hash, 'batcharge', 0); # aktuelle Ladung in %
|
||||
my $batinstcap = CurrentVal ($hash, 'batinstcap', 0); # installierte Batteriekapazität Wh
|
||||
my $cgbt = AttrVal ($name, 'ctrlBatSocManagement', undef);
|
||||
|
||||
|
||||
if ($cgbt && !$batinstcap) {
|
||||
Log3 ($name, 1, "$name - WARNING - Attribute ctrlBatSocManagement is active, but the required key 'cap' is not setup in setupBatteryDev. Exit.");
|
||||
return;
|
||||
@ -9380,61 +9397,83 @@ sub _batSocTarget {
|
||||
delete $paref->{careCycle};
|
||||
|
||||
my $nt = '';
|
||||
my $chargereq = 0; # Ladeanforderung wenn SoC unter Minimum SoC gefallen ist
|
||||
my $chargereq = 0; # Ladeanforderung wenn SoC unter Minimum SoC gefallen ist
|
||||
my $target = $lowSoc;
|
||||
my $yday = strftime "%d", localtime($t - 86400); # Vortag (range 01 to 31)
|
||||
my $batymaxsoc = HistoryVal ($hash, $yday, 99, 'batmaxsoc', 0); # gespeicherter max. SOC des Vortages
|
||||
my $batysetsoc = HistoryVal ($hash, $yday, 99, 'batsetsoc', $lowSoc); # gespeicherter SOC Sollwert des Vortages
|
||||
|
||||
my $yday = strftime "%d", localtime($t - 86400); # Vortag (range 01 to 31)
|
||||
my $tdconsset = CurrentVal ($hash, 'tdConFcTillSunset', 0); # Verbrauch bis Sonnenuntergang Wh
|
||||
my $batymaxsoc = HistoryVal ($hash, $yday, 99, 'batmaxsoc', 0); # gespeicherter max. SOC des Vortages
|
||||
my $batysetsoc = HistoryVal ($hash, $yday, 99, 'batsetsoc', $lowSoc); # gespeicherter SOC Sollwert des Vortages
|
||||
my $whneed = ($maxsoc / 100 * $batinstcap) - ($batcharge / 100 * $batinstcap); # benötigte Ladeenergie in Wh bis $maxsoc
|
||||
$whneed = sprintf "%.0f", $whneed;
|
||||
|
||||
$target = $batymaxsoc < $maxsoc ? $batysetsoc + $batSocChgDay :
|
||||
$batymaxsoc >= $maxsoc ? $batysetsoc - $batSocChgDay :
|
||||
$batysetsoc; # neuer Min SOC für den laufenden Tag
|
||||
$batysetsoc; # neuer Min SOC für den laufenden Tag
|
||||
|
||||
debugLog ($paref, 'batteryManagement', "SoC calc Step1 - compare with SoC history -> preliminary new Target: $target %");
|
||||
|
||||
## Pflege-SoC (Soll SoC $maxSoCdef bei $batSocChgDay % Steigerung p. Tag)
|
||||
###########################################################################
|
||||
my $sunset = CurrentVal ($hash, 'sunsetTodayTs', $t);
|
||||
my $delayts = $sunset - 5400; # Pflege-SoC/Erhöhung SoC erst ab 1,5h vor Sonnenuntergang berechnen/anwenden
|
||||
my $delayts = $sunset - 5400; # Pflege-SoC/Erhöhung SoC erst ab 1,5h vor Sonnenuntergang berechnen/anwenden
|
||||
my $la = '';
|
||||
my $careSoc = $target;
|
||||
|
||||
if ($t > $delayts) {
|
||||
my $ntsmsc = CircularVal ($hash, 99, 'nextTsMaxSocChge', $t);
|
||||
my $days2care = ceil (($ntsmsc - $t) / 86400); # verbleibende Tage bis der Batterie Pflege-SoC (default 95%) erreicht sein soll
|
||||
|
||||
my $pvfctm = ReadingsNum ($name, 'Tomorrow_PVforecast', 0); # PV Prognose morgen
|
||||
my $pvfctd = ReadingsNum ($name, 'RestOfDayPVforecast', 0); # PV Prognose Rest heute
|
||||
my $pvexpect = $pvfctm > $pvfctd ? $pvfctm : $pvfctd - $tdconsset; # erwartete (Rest) PV-Leistung des Tages
|
||||
$pvexpect = $pvexpect > 0 ? $pvexpect : 0; # erwartete PV-Leistung inkl. Verbrauchsprognose bis Sonnenuntergang
|
||||
|
||||
my $ntsmsc = CircularVal ($hash, 99, 'nextTsMaxSocChge', $t);
|
||||
my $days2care = floor (($ntsmsc - $t) / 86400); # verbleibende Tage bis der Batterie Pflege-SoC (default 95%) erreicht sein soll
|
||||
|
||||
my $docare = 0; # keine Zwangsanwendung care SoC
|
||||
|
||||
if ($t > $delayts || $pvexpect < $whneed || !$days2care) {
|
||||
$paref->{days2care} = $days2care;
|
||||
__batSaveSocKeyFigures ($paref);
|
||||
delete $paref->{days2care};
|
||||
|
||||
$careSoc = $maxsoc - ($days2care * $batSocChgDay); # Pflege-SoC um rechtzeitig den $maxsoc zu erreichen bei 5% Steigerung pro Tag
|
||||
$target = $careSoc < $target ? $target : $careSoc; # resultierender Target-SoC unter Berücksichtigung $caresoc
|
||||
$la = "calculate care SoC ($days2care days) -> Target: $target %";
|
||||
$careSoc = $maxsoc - ($days2care * $batSocChgDay); # Pflege-SoC um rechtzeitig den $maxsoc zu erreichen bei 5% Steigerung pro Tag
|
||||
$careSoc = $careSoc < $lowSoc ? $lowSoc : $careSoc;
|
||||
|
||||
if ($careSoc >= $target) {
|
||||
$target = $careSoc; # resultierender Target-SoC unter Berücksichtigung $caresoc
|
||||
$docare = 1; # Zwangsanwendung care SoC
|
||||
}
|
||||
|
||||
$la = "calc care SoC -> Remaining days until care SoC: $days2care, Target: $target %";
|
||||
}
|
||||
else {
|
||||
$nt = (timestampToTimestring ($delayts, $paref->{lang}))[0];
|
||||
$la = "calculate care SoC -> calculation & activation postponed to after $nt";
|
||||
$la = "calc care SoC -> use preliminary Target: $target % (care SoC calculation & activation postponed to after $nt)";
|
||||
}
|
||||
|
||||
debugLog ($paref, 'batteryManagement', "SoC calc Step2 - basics -> docare: $docare, care SoC: $careSoc %, E expect: $pvexpect Wh, need for care SoC: $whneed Wh");
|
||||
debugLog ($paref, 'batteryManagement', "SoC calc Step2 - $la");
|
||||
|
||||
## Aufladewahrscheinlichkeit beachten
|
||||
#######################################
|
||||
my $pvfctm = ReadingsNum ($name, 'Tomorrow_PVforecast', 0); # PV Prognose morgen
|
||||
my $pvfctd = ReadingsNum ($name, 'RestOfDayPVforecast', 0); # PV Prognose Rest heute
|
||||
my $csopt = ReadingsNum ($name, 'Battery_OptimumTargetSoC', $lowSoc); # aktuelles SoC Optimum
|
||||
|
||||
my $pvexpect = $pvfctm > $pvfctd ? $pvfctm : $pvfctd;
|
||||
my $cantarget = 100 - (100 / $batinstcap) * $pvexpect; # berechneter möglicher Min SOC nach Berücksichtigung Ladewahrscheinlichkeit
|
||||
|
||||
my $newtarget = sprintf "%.0f", ($cantarget < $target ? $cantarget : $target); # Abgleich möglicher Min SOC gg. berechneten Min SOC
|
||||
my $csopt = ReadingsNum ($name, 'Battery_OptimumTargetSoC', $lowSoc); # aktuelles SoC Optimum
|
||||
my $cantarget = sprintf "%.0f", (100 - (100 / $batinstcap * $pvexpect)); # berechneter max. möglicher SOC nach Berücksichtigung Ladewahrscheinlichkeit
|
||||
my $newtarget = sprintf "%.0f", ($cantarget < $target ? $cantarget : $target); # Abgleich möglicher Min SOC gg. berechneten Min SOC
|
||||
|
||||
debugLog ($paref, 'batteryManagement', "SoC calc Step3 - basics -> cantarget: $cantarget %, newtarget: $newtarget %");
|
||||
|
||||
if ($newtarget > $careSoc) {
|
||||
$docare = 0; # keine Zwangsanwendung care SoC
|
||||
}
|
||||
else {
|
||||
$newtarget = $careSoc;
|
||||
}
|
||||
|
||||
my $logadd = '';
|
||||
|
||||
if ($newtarget > $csopt && $t > $delayts) { # Erhöhung des SoC (wird ab Sonnenuntergang angewendet)
|
||||
$target = $newtarget;
|
||||
$logadd = "(new target > $csopt % and Sunset has passed)";
|
||||
}
|
||||
elsif ($newtarget > $csopt && $t <= $delayts) { # bisheriges Optimum bleibt vorerst
|
||||
elsif ($newtarget > $csopt && $t <= $delayts && !$docare) { # bisheriges Optimum bleibt vorerst
|
||||
$target = $csopt;
|
||||
$nt = (timestampToTimestring ($delayts, $paref->{lang}))[0];
|
||||
$logadd = "(new target $newtarget % is activated after $nt)";
|
||||
@ -9448,19 +9487,16 @@ sub _batSocTarget {
|
||||
$logadd = "(no change)";
|
||||
}
|
||||
|
||||
debugLog ($paref, 'batteryManagement', "SoC calc Step3 - charging probability -> Target: $target % ".$logadd);
|
||||
debugLog ($paref, 'batteryManagement', "SoC calc Step3 - charging probability -> docare: $docare, Target: $target % ".$logadd);
|
||||
|
||||
## low/up-Grenzen beachten
|
||||
############################
|
||||
$target = $target > $upSoc ? $upSoc :
|
||||
$target = $docare ? $target :
|
||||
$target > $upSoc ? $upSoc :
|
||||
$target < $lowSoc ? $lowSoc :
|
||||
$target;
|
||||
|
||||
if ($t > $delayts) { # evtl. Aktivierung Pflegesock nach Sonnenuntergang
|
||||
$target = $careSoc > $target ? $careSoc : $target;
|
||||
}
|
||||
|
||||
debugLog ($paref, 'batteryManagement', "SoC calc Step4 - observe low/up limits -> Target: $target %".($careSoc > $target ? " (activation of care SoC $careSoc % is postponed)" : ''));
|
||||
debugLog ($paref, 'batteryManagement', "SoC calc Step4 - observe low/up limits -> docare: $docare, Target: $target %");
|
||||
|
||||
## auf 5er Schritte anpassen (40,45,50,...)
|
||||
#############################################
|
||||
@ -9469,7 +9505,7 @@ sub _batSocTarget {
|
||||
my $add = $rmn <= 2.5 ? 0 : 5;
|
||||
$target = ($flo * 5) + $add;
|
||||
|
||||
debugLog ($paref, 'batteryManagement', "SoC calc Step5 - rounding the SoC to steps of 5 -> Target: $target %");
|
||||
debugLog ($paref, 'batteryManagement', "SoC calc Step5 - rounding the SoC to steps of 5 % -> Target: $target %");
|
||||
|
||||
## Zwangsladeanforderung
|
||||
##########################
|
||||
@ -9512,7 +9548,7 @@ sub __batSaveSocKeyFigures {
|
||||
my $paref = shift;
|
||||
my $name = $paref->{name};
|
||||
my $type = $paref->{type};
|
||||
my $t = $paref->{t}; # aktuelle Zeit
|
||||
my $t = $paref->{t}; # aktuelle Zeit
|
||||
my $careCycle = $paref->{careCycle} // $carecycledef;
|
||||
|
||||
if (defined $paref->{days2care}) {
|
||||
@ -10802,12 +10838,8 @@ sub __setConsRcmdState {
|
||||
my $ccr = AttrVal ($name, 'ctrlConsRecommendReadings', ''); # Liste der Consumer für die ConsumptionRecommended-Readings erstellt werden sollen
|
||||
my $rescons = isConsumerPhysOn ($hash, $c) ? 0 : $nompower; # resultierender Verbauch nach Einschaltung Consumer
|
||||
|
||||
my $method = 'Median';
|
||||
my $splref = CurrentVal ($hash, 'surplusslidereg', '');
|
||||
|
||||
# $surplusval kann undef sein! -> dann letzten Wert isConsumptionRecommended behalten
|
||||
my $surplusval = $method eq 'Median' ? medianArray ($splref) : # Median des Energieüberschußes
|
||||
avgArray ($splref, 6); # Durchschnitt Energieüberschuß der letzten X Messungen
|
||||
my ($method, $surplusval) = determSurplus ($hash, $c); # Consumer spezifische Ermittlung des Energieüberschußes
|
||||
|
||||
if ($debug =~ /consumerSwitching${c}/x) {
|
||||
Log3 ($name, 1, qq{$name DEBUG> ############### consumerSwitching consumer "$c" ###############});
|
||||
@ -10815,11 +10847,11 @@ sub __setConsRcmdState {
|
||||
(defined $surplusval ? $surplusval : 'undef'));
|
||||
}
|
||||
|
||||
my ($spignore, $info, $err) = isSurplusIgnoCond ($hash, $c, $debug); # Vorhandensein PV Überschuß ignorieren ?
|
||||
my ($spignore, $info, $err) = isSurplusIgnoCond ($hash, $c, $debug); # PV Überschuß ignorieren?
|
||||
Log3 ($name, 1, "$name - $err") if($err);
|
||||
|
||||
if (!$nompower || $surplus - $rescons > 0 || $spignore) {
|
||||
$data{$name}{consumers}{$c}{isConsumptionRecommended} = 1; # Einschalten des Consumers günstig bzw. Freigabe für "on" von Überschußseite erteilt
|
||||
$data{$name}{consumers}{$c}{isConsumptionRecommended} = 1; # Einschalten des Consumers günstig bzw. Freigabe für "on" von Überschußseite erteilt
|
||||
}
|
||||
else {
|
||||
$data{$name}{consumers}{$c}{isConsumptionRecommended} = 0;
|
||||
@ -17640,6 +17672,65 @@ sub checkPlantConfig {
|
||||
return $out;
|
||||
}
|
||||
|
||||
################################################################
|
||||
# Ermittelt den PV Überschuß nach verschiedenen Verfahren
|
||||
# ($surpmeth). Auswertung des Schieberegisters surplusslidereg.
|
||||
#
|
||||
# $surpmeth = 1 - der aktuell gemessene Überschuß
|
||||
# $surpmeth = 2 .. 20 - Durchschnitt der letzten X Messungen
|
||||
# $surpmeth = median - Median der vorhandenen Überschußwerte
|
||||
#
|
||||
# Rückgabe: PV Überschuß oder undef
|
||||
#
|
||||
################################################################
|
||||
sub determSurplus {
|
||||
my $hash = shift;
|
||||
my $c = shift;
|
||||
|
||||
my $surpmeth = ConsumerVal ($hash, $c, 'surpmeth', 1);
|
||||
my $splref = CurrentVal ($hash, 'surplusslidereg', '');
|
||||
my $name = $hash->{NAME};
|
||||
my $method = 'default';
|
||||
my $surplus;
|
||||
|
||||
if ($surpmeth eq 'median') { # Median der Werte in surplusslidereg
|
||||
$surplus = medianArray ($splref);
|
||||
$method = 'median';
|
||||
}
|
||||
elsif ($surpmeth =~ /^[1-9]$|^1[0-9]$|^20$/xs) {
|
||||
if ($surpmeth == 1) {
|
||||
$surplus = CurrentVal ($hash, 'surplus', 0); # aktueller Energieüberschuß
|
||||
$method = 'median';
|
||||
}
|
||||
else { # Average Ermittlung, kann undef sein
|
||||
$surplus = avgArray ($splref, $surpmeth);
|
||||
$method = "average:$surpmeth";
|
||||
}
|
||||
}
|
||||
elsif ($surpmeth =~ /.*:.*/xs) {
|
||||
my ($dv, $rd) = split ':', $surpmeth;
|
||||
my ($err) = isDeviceValid ( { name => $name, obj => $dv, method => 'string' } );
|
||||
|
||||
if ($err) {
|
||||
Log3 ($name, 1, qq{$name - ERROR of consumer $c key 'surpmeth': $err (fall back to default Surplus determination)});
|
||||
$surplus = CurrentVal ($hash, 'surplus', 0); # aktueller Energieüberschuß
|
||||
$method = 'default';
|
||||
}
|
||||
else {
|
||||
$surplus = ReadingsNum ($dv, $rd, '');
|
||||
$method = "$dv:$rd";
|
||||
|
||||
if (!isNumeric ($surplus)) {
|
||||
Log3 ($name, 1, qq{$name - ERROR of consumer $c key 'surpmeth': Device $dv / Reading $rd is not numeric (fall back to default Surplus determination)});
|
||||
$surplus = CurrentVal ($hash, 'surplus', 0); # aktueller Energieüberschuß
|
||||
$method = 'default';
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
return ($method, $surplus);
|
||||
}
|
||||
|
||||
################################################################
|
||||
# Array auf eine festgelegte Anzahl Elemente beschränken,
|
||||
# Das älteste Element wird entfernt
|
||||
@ -21478,15 +21569,15 @@ to ensure that the system configuration is correct.
|
||||
|
||||
<table>
|
||||
<colgroup> <col width="2%"> <col width="98%"> </colgroup>
|
||||
<tr><td> 1. </td><td>Starting from 'lowSoc', the minimum SoC is increased by 5% on the following day but not higher than </td></tr>
|
||||
<tr><td> </td><td>'upSoC', if 'maxSoC' has not been reached on the current day. </td></tr>
|
||||
<tr><td> 2. </td><td>If 'maxSoC' is reached (again) on the current day, the minimum SoC is reduced by 5%, but not lower than 'lowSoc'. </td></tr>
|
||||
<tr><td> 3. </td><td>Minimum SoC is reduced so that the predicted PV energy of the current or following day </td></tr>
|
||||
<tr><td> </td><td>can be absorbed by the battery. Minimum SoC is not reduced lower than 'lowSoc'. </td></tr>
|
||||
<tr><td> 4. </td><td>The module records the last point in time at the 'maxSoC' level in order to ensure a charge to 'maxSoC' </td></tr>
|
||||
<tr><td> </td><td>at least every 'careCycle' days. For this purpose, the optimized SoC is changed depending on the remaining days </td></tr>
|
||||
<tr><td> </td><td>until the next 'careCycle' point in such a way that 'maxSoC' is mathematically achieved by a daily 5% SoC increase </td></tr>
|
||||
<tr><td> </td><td>at the 'careCycle' time point. If 'maxSoC' is reached in the meantime, the 'careCycle' period starts again. </td></tr>
|
||||
<tr><td> 1. </td><td>Starting from 'lowSoc', the minimum SoC is increased by 5% on the following day but not higher than </td></tr>
|
||||
<tr><td> </td><td>'upSoC', if 'maxSoC' has not been reached on the current day. </td></tr>
|
||||
<tr><td> 2. </td><td>If 'maxSoC' is reached (again), the minimum SoC is reduced by 5%, but not lower than 'lowSoc'. </td></tr>
|
||||
<tr><td> 3. </td><td>Minimum SoC is reduced to the extent that the predicted PV energy for the current or following </td></tr>
|
||||
<tr><td> </td><td>day can be absorbed by the battery. Minimum SoC is typically reduced to 'upSoc' and not lower than 'lowSoc'. </td></tr>
|
||||
<tr><td> 4. </td><td>The module records the last point in time at the 'maxSoC' level in order to ensure a charge to 'maxSoC' </td></tr>
|
||||
<tr><td> </td><td>at least every 'careCycle' days. For this purpose, the optimized SoC is changed depending on the remaining days </td></tr>
|
||||
<tr><td> </td><td>until the next 'careCycle' point in such a way that 'maxSoC' is mathematically achieved by a daily 5% SoC increase </td></tr>
|
||||
<tr><td> </td><td>at the 'careCycle' time point. If 'maxSoC' is reached in the meantime, the 'careCycle' period starts again. </td></tr>
|
||||
</table>
|
||||
<br>
|
||||
|
||||
@ -23903,15 +23994,15 @@ die ordnungsgemäße Anlagenkonfiguration geprüft werden.
|
||||
|
||||
<table>
|
||||
<colgroup> <col width="2%"> <col width="98%"> </colgroup>
|
||||
<tr><td> 1. </td><td>Ausgehend von 'lowSoc' wird der Mindest-SoC am folgenden Tag um 5%, aber nicht höher als </td></tr>
|
||||
<tr><td> </td><td>'upSoC' inkrementiert, sofern am laufenden Tag 'maxSoC' nicht erreicht wurde. </td></tr>
|
||||
<tr><td> 2. </td><td>Wird am laufenden Tag 'maxSoC' (wieder) erreicht, wird Mindest-SoC um 5%, aber nicht tiefer als 'lowSoc', verringert. </td></tr>
|
||||
<tr><td> 3. </td><td>Mindest-SoC wird soweit verringert, dass die prognostizierte PV Energie des aktuellen bzw. des folgenden Tages </td></tr>
|
||||
<tr><td> </td><td>von der Batterie aufgenommen werden kann. Mindest-SoC wird nicht tiefer als 'lowSoc' verringert. </td></tr>
|
||||
<tr><td> 4. </td><td>Das Modul erfasst den letzten Zeitpunkt am 'maxSoC'-Level, um eine Ladung auf 'maxSoC' mindestens alle 'careCycle' </td></tr>
|
||||
<tr><td> </td><td>Tage zu realisieren. Zu diesem Zweck wird der optimierte SoC in Abhängigkeit der Resttage bis zum nächsten </td></tr>
|
||||
<tr><td> </td><td>'careCycle' Zeitpunkt derart verändert, dass durch eine tägliche 5% SoC-Steigerung 'maxSoC' am 'careCycle' Zeitpunkt </td></tr>
|
||||
<tr><td> </td><td>rechnerisch erreicht wird. Wird zwischenzeitlich 'maxSoC' erreicht, beginnt der 'careCycle' Zeitraum erneut. </td></tr>
|
||||
<tr><td> 1. </td><td>Ausgehend von 'lowSoc' wird der Mindest-SoC kurz vor Sonnenuntergang um 5% inkrementiert sofern am laufenden </td></tr>
|
||||
<tr><td> </td><td>Tag 'maxSoC' nicht erreicht wurde und die PV-Prognose keinen hinreichenden Ertrag des kommenden Tages vorhersagt. </td></tr>
|
||||
<tr><td> 2. </td><td>Wird 'maxSoC' (wieder) erreicht, wird Mindest-SoC um 5%, aber nicht tiefer als 'lowSoc', verringert. </td></tr>
|
||||
<tr><td> 3. </td><td>Mindest-SoC wird soweit verringert, dass die prognostizierte PV Energie des aktuellen bzw. des folgenden Tages </td></tr>
|
||||
<tr><td> </td><td>von der Batterie aufgenommen werden kann. Mindest-SoC wird typisch auf 'upSoc' und nicht tiefer als 'lowSoc' verringert. </td></tr>
|
||||
<tr><td> 4. </td><td>Das Modul erfasst den letzten Zeitpunkt am 'maxSoC'-Level, um eine Ladung auf 'maxSoC' mindestens alle 'careCycle' </td></tr>
|
||||
<tr><td> </td><td>Tage zu realisieren. Zu diesem Zweck wird der optimierte SoC in Abhängigkeit der Resttage bis zum nächsten </td></tr>
|
||||
<tr><td> </td><td>'careCycle' Zeitpunkt derart verändert, dass durch eine tägliche 5% SoC-Steigerung 'maxSoC' am 'careCycle' Zeitpunkt </td></tr>
|
||||
<tr><td> </td><td>rechnerisch erreicht wird. Wird zwischenzeitlich 'maxSoC' erreicht, beginnt der 'careCycle' Zeitraum erneut. </td></tr>
|
||||
</table>
|
||||