@ -28,7 +28,9 @@
|
||||
#################################################################################################################
|
||||
# Versions History by DS_Starter
|
||||
#
|
||||
# 2.11.0 17.08.2019 attr target-serial, target-susyid are set automatically if not defined
|
||||
#
|
||||
# 2.12.0 18.08.2019 set warning to log if SPOT_ETODAY, SPOT_ETOTAL was not delivered (SMA_command), Forum: https://forum.fhem.de/index.php/topic,56080.msg967823.html#msg967823
|
||||
# 2.11.0 17.08.2019 attr target-serial, target-susyid are set automatically if not defined, commandref revised
|
||||
# 2.10.2 14.08.2019 new types to %SMAInverter_devtypes
|
||||
# 2.10.1 28.04.2019 fix perl warnings, Forum:#56080.msg933276.html#msg933276
|
||||
# 2.10.0 29.06.2018 Internal MODEL added
|
||||
@ -85,7 +87,7 @@ use Time::HiRes qw(gettimeofday tv_interval);
|
||||
use Blocking;
|
||||
use Time::Local;
|
||||
|
||||
my $SMAInverterVersion = "2.10.2";
|
||||
my $SMAInverterVersion = "2.12.0";
|
||||
|
||||
# Inverter Data fields and supported commands flags.
|
||||
# $inv_SPOT_ETODAY # Today yield
|
||||
@ -1117,8 +1119,16 @@ sub SMA_command($$$$$) {
|
||||
Log3 $name, 5, "$name - Data identifier $data_ID";
|
||||
|
||||
if($data_ID eq 0x2601) {
|
||||
$inv_SPOT_ETOTAL = unpack("V*", substr($data, 62, 4));
|
||||
$inv_SPOT_ETODAY = unpack("V*", substr $data, 78, 4);
|
||||
eval { $inv_SPOT_ETOTAL = unpack("V*", substr($data, 62, 4)); };
|
||||
if ($@) {
|
||||
Log3 $name, 3, "$name - WARNING - SPOT_ETOTAL wasn't deliverd ... set it to \"0\" !";
|
||||
$inv_SPOT_ETOTAL = 0;
|
||||
}
|
||||
eval { $inv_SPOT_ETODAY = unpack("V*", substr $data, 78, 4); };
|
||||
if ($@) {
|
||||
Log3 $name, 3, "$name - WARNING - SPOT_ETODAY wasn't deliverd ... set it to \"0\" !";
|
||||
$inv_SPOT_ETODAY = 0;
|
||||
}
|
||||
Log3 $name, 5, "$name - Found Data SPOT_ETOTAL=$inv_SPOT_ETOTAL and SPOT_ETODAY=$inv_SPOT_ETODAY";
|
||||
return (1,$inv_SPOT_ETODAY,$inv_SPOT_ETOTAL,$inv_susyid,$inv_serial);
|
||||
}
|
||||
@ -1629,31 +1639,113 @@ The retrieval of the inverter will be executed non-blocking. You can adjust the
|
||||
<b>Get</b>
|
||||
<br>
|
||||
<ul>
|
||||
<code>get <name> data</code>
|
||||
<br><br>
|
||||
|
||||
The request of the inverter will be executed. Those possibility is especifically created for the "manual" operation mode (see attribute "mode").
|
||||
<li><b> get <name> data </b>
|
||||
<br><br>
|
||||
|
||||
The request of the inverter will be executed. Those possibility is especifically created for the "manual" operation
|
||||
mode (see attribute "mode").
|
||||
<br>
|
||||
</li>
|
||||
|
||||
<br>
|
||||
</ul>
|
||||
|
||||
<b>Attributes</b>
|
||||
<ul>
|
||||
<li><b>interval</b> : Queryintreval in seconds </li>
|
||||
<li><b>detail-level</b> : "0" - Only Power and Energy / "1" - Including Voltage and Current / "2" - All values </li>
|
||||
<li><b>disable</b> : 1 = the module is disabled </li>
|
||||
<li><b>mode</b> : automatic = the inverter will be polled by preset interval, manual = query only by command "get <name> data" </li>
|
||||
<li><b>offset</b> : time in seconds to prefer the sunrise respectively defer the sunset virtualy (0 ... 7200). You will be able to extend the working
|
||||
period of the module. </li>
|
||||
<li><b>SBFSpotComp</b> : 1 = the readings are created like SBFSpot-style </li>
|
||||
<li><b>suppressSleep</b> : the sleep mode (after sunset, before sunrise) is deactivated and the inverter will be polled continuously. </li>
|
||||
<li><b>showproctime</b> : shows processing time in background and wasted time to retrieve inverter data </li>
|
||||
<li><b>target-susyid</b> : In case of a Multigate the target SUSyID can be defined. If more than one inverter is installed you have to
|
||||
set the inverter-SUSyID to assign the inverter to the device definition.
|
||||
Default is 0xFFFF, means any SUSyID</li>
|
||||
<li><b>target-serial</b> : In case of a Multigate the target Serialnumber can be defined. If more than one inverter is installed you have to
|
||||
set the inverter-Serialnumber to assign the inverter to the device definition.
|
||||
Default is 0xFFFFFFFF, means any Serialnumber</li>
|
||||
<li><b>timeout</b> : setup timeout of inverter data request (default 60s) </li>
|
||||
|
||||
<a name="detail-level"></a>
|
||||
<li><b>detail-level [0|1|2] </b><br>
|
||||
Defines the complexity of the generated readings. <br><br>
|
||||
|
||||
<ul>
|
||||
<table>
|
||||
<colgroup> <col width=10%> <col width=90%> </colgroup>
|
||||
<tr><td> 0 </td><td>- only Power and Energy </td></tr>
|
||||
<tr><td> 1 </td><td>- as 0, additional voltage and current </td></tr>
|
||||
<tr><td> 2 </td><td>- all values </td></tr>
|
||||
</table>
|
||||
</ul>
|
||||
|
||||
</li>
|
||||
<br>
|
||||
|
||||
<a name="disable"></a>
|
||||
<li><b>disable [1|0]</b><br>
|
||||
Deactivate/activate the module.
|
||||
</li>
|
||||
<br>
|
||||
|
||||
<a name="interval"></a>
|
||||
<li><b>interval </b><br>
|
||||
Request cycle in seconds. (default: 60)
|
||||
</li>
|
||||
<br>
|
||||
|
||||
<a name="mode"></a>
|
||||
<li><b>mode [automatic|manual] </b><br>
|
||||
The request mode of the inverter. (default: automatic) <br><br>
|
||||
|
||||
<ul>
|
||||
<table>
|
||||
<colgroup> <col width=10%> <col width=90%> </colgroup>
|
||||
<tr><td> automatic </td><td>- the inverter will be polled regularly as defined by attribute "interval" </td></tr>
|
||||
<tr><td> manual </td><td>- query only by command "get <name> data" </td></tr>
|
||||
</table>
|
||||
</ul>
|
||||
|
||||
</li>
|
||||
<br>
|
||||
|
||||
<a name="offset"></a>
|
||||
<li><b>offset <0 - 7200> </b><br>
|
||||
Time in seconds to forward the real sunrise respectively defer the real sunset.
|
||||
You will be able to extend the working period of the module.
|
||||
</li>
|
||||
<br>
|
||||
|
||||
<a name="SBFSpotComp"></a>
|
||||
<li><b>SBFSpotComp [1|0]</b><br>
|
||||
The reading names are created like the SBFSpot-style. (default: 0)
|
||||
</li>
|
||||
<br>
|
||||
|
||||
<a name="showproctime"></a>
|
||||
<li><b>showproctime [1|0]</b><br>
|
||||
Shows the processing time in background and the wasted time to retrieve inverter data. (default: 0)
|
||||
</li>
|
||||
<br>
|
||||
|
||||
<a name="suppressSleep"></a>
|
||||
<li><b>suppressSleep [1|0]</b><br>
|
||||
The sleep mode (after sunset and before sunrise) is deactivated and the inverter will be polled continuously. (default: 0)
|
||||
</li>
|
||||
<br>
|
||||
|
||||
<a name="target-serial"></a>
|
||||
<li><b>target-serial </b><br>
|
||||
In case of a Multigate the target serial number has to be defined. If more than one inverter is installed,
|
||||
you have to set the inverter serial number to assign the inverter to the device definition.
|
||||
If only one inverter available, the attribut is set automatically once the serial number of the inverter was detected.
|
||||
(default: 0xFFFFFFFF = means any serial number)
|
||||
</li>
|
||||
<br>
|
||||
|
||||
<a name="target-susyid"></a>
|
||||
<li><b>target-susyid </b><br>
|
||||
In case of a Multigate the target SUSyID has to be defined. If more than one inverter is installed,
|
||||
you have to set the inverter-SUSyID to assign the inverter to the device definition.
|
||||
If only one inverter available, the attribut is set automatically once the SUSyID of the inverter was detected.
|
||||
(default: 0xFFFF = means any SUSyID)
|
||||
</li>
|
||||
<br>
|
||||
|
||||
<a name="timeout"></a>
|
||||
<li><b>timeout </b><br>
|
||||
Setup timeout of inverter data request in seconds. (default 60)
|
||||
</li>
|
||||
<br>
|
||||
|
||||
</ul>
|
||||
|
||||
<b>Readings</b>
|
||||
@ -1778,31 +1870,115 @@ Die Abfrage des Wechselrichters wird non-blocking ausgeführt. Der Timeoutwert f
|
||||
<b>Get</b>
|
||||
<br>
|
||||
<ul>
|
||||
<code>get <name> data</code>
|
||||
<br><br>
|
||||
|
||||
Die Datenabfrage des Wechselrichters wird ausgeführt. Diese Möglichkeit ist speziell für den Betriebsmodus "manual" vorgesehen (siehe Attribut "mode").
|
||||
|
||||
<li><b> get <name> data </b>
|
||||
<br><br>
|
||||
|
||||
Die Datenabfrage des Wechselrichters wird ausgeführt. Diese Möglichkeit ist speziell für den Betriebsmodus "manual"
|
||||
vorgesehen (siehe Attribut "mode").
|
||||
<br>
|
||||
</li>
|
||||
<br>
|
||||
</ul>
|
||||
|
||||
<b>Attribute</b>
|
||||
<br<br>
|
||||
<ul>
|
||||
<li><b>interval</b> : Abfrageinterval in Sekunden </li>
|
||||
<li><b>detail-level</b> : "0" - Nur Leistung und Energie / "1" - zusätzlich Strom und Spannung / "2" - Alle Werte </li>
|
||||
<li><b>disable</b> : 1 = das Modul ist disabled </li>
|
||||
<li><b>mode</b> : automatic = die Wechselrichterwerte werden im eingestellten Interval abgefragt, manual = Abfrage nur mit "get <name> data" </li>
|
||||
<li><b>offset</b> : Zeit in Sekunden um die der Sonnenaufgang vorgezogen bzw. Sonnenuntergang verzögert wird (0 ... 7200). Dadurch wird die
|
||||
effektive Aktivzeit des Moduls erweitert. </li>
|
||||
<li><b>suppressSleep</b> : der Schlafmodus (nach Sonnenuntergang, vor Sonnenaufgang) wird ausgeschaltet und der WR abgefragt. </li>
|
||||
<li><b>showproctime</b> : zeigt die für den Hintergrundprozess und die Abfrage des Wechselrichter verbrauchte Zeit. </li>
|
||||
<li><b>SBFSpotComp</b> : 1 = die Readings werden kompatibel zu SBFSpot-Ausgaben erzeugt </li>
|
||||
<li><b>target-susyid</b> : Im Falle eines Multigate kann die Ziel-SUSyID definiert werden. Ist mehr als ein Wechselrichter installiert,
|
||||
muß die Wechselreichter-SUSyID gesetzt werden um den Wechselrichter der Device-Definition eindeutig zuzuweisen.
|
||||
Default ist 0xFFFF (=keine Einschränkung)</li>
|
||||
<li><b>target-serial</b> : Im Falle eines Multigate kann die Ziel-Seriennummer definiert werden. Ist mehr als ein Wechselrichter installiert,
|
||||
muß die Wechselreichter-Seriennummer gesetzt werden um den Wechselrichter der Device-Definition eindeutig zuzuweisen.
|
||||
Default ist 0xFFFFFFFF (=keine Einschränkung)</li>
|
||||
<li><b>timeout</b> : Einstellung des timeout für die Wechselrichterabfrage (default 60s) </li>
|
||||
|
||||
<a name="detail-level"></a>
|
||||
<li><b>detail-level [0|1|2] </b><br>
|
||||
Legt den Umfang der ausgegebenen Readings fest. <br><br>
|
||||
|
||||
<ul>
|
||||
<table>
|
||||
<colgroup> <col width=10%> <col width=90%> </colgroup>
|
||||
<tr><td> 0 </td><td>- nur Leistung und Energie </td></tr>
|
||||
<tr><td> 1 </td><td>- wie 0, zusätzlich Strom und Spannung </td></tr>
|
||||
<tr><td> 2 </td><td>- alle Werte </td></tr>
|
||||
</table>
|
||||
</ul>
|
||||
|
||||
</li>
|
||||
<br>
|
||||
|
||||
<a name="disable"></a>
|
||||
<li><b>disable [1|0]</b><br>
|
||||
Deaktiviert/aktiviert das Modul.
|
||||
</li>
|
||||
<br>
|
||||
|
||||
<a name="interval"></a>
|
||||
<li><b>interval </b><br>
|
||||
Abfrageinterval in Sekunden. (default: 60)
|
||||
</li>
|
||||
<br>
|
||||
|
||||
<a name="mode"></a>
|
||||
<li><b>mode [automatic|manual] </b><br>
|
||||
Abfragemodus des Wechselrichters. (default: automatic) <br><br>
|
||||
|
||||
<ul>
|
||||
<table>
|
||||
<colgroup> <col width=10%> <col width=90%> </colgroup>
|
||||
<tr><td> automatic </td><td>- die Wechselrichterwerte werden im eingestellten Interval abgefragt (Attribut "interval") </td></tr>
|
||||
<tr><td> manual </td><td>- Abfrage nur mit "get <name> data" </td></tr>
|
||||
</table>
|
||||
</ul>
|
||||
|
||||
</li>
|
||||
<br>
|
||||
|
||||
<a name="offset"></a>
|
||||
<li><b>offset <0 - 7200> </b><br>
|
||||
Zeit in Sekunden, um die der reale Sonnenaufgang vorgezogen bzw. reale Sonnenuntergang verzögert wird.
|
||||
Dadurch wird die effektive Aktivzeit des Moduls erweitert.
|
||||
</li>
|
||||
<br>
|
||||
|
||||
<a name="SBFSpotComp"></a>
|
||||
<li><b>SBFSpotComp [1|0]</b><br>
|
||||
Die Readingnamen werden kompatibel zu SBFSpot-Ausgaben erzeugt. (default: 0)
|
||||
</li>
|
||||
<br>
|
||||
|
||||
<a name="showproctime"></a>
|
||||
<li><b>showproctime [1|0]</b><br>
|
||||
Zeigt die für den Hintergrundprozess und die Abfrage des Wechselrichter verbrauchte Zeit. (default: 0)
|
||||
</li>
|
||||
<br>
|
||||
|
||||
<a name="suppressSleep"></a>
|
||||
<li><b>suppressSleep [1|0]</b><br>
|
||||
Der Schlafmodus (nach Sonnenuntergang und vor Sonnenaufgang) wird ausgeschaltet und der WR abgefragt. (default: 0)
|
||||
</li>
|
||||
<br>
|
||||
|
||||
<a name="target-serial"></a>
|
||||
<li><b>target-serial </b><br>
|
||||
Im Falle eines Multigate muss die Ziel-Seriennummer definiert werden. Ist mehr als ein Wechselrichter installiert,
|
||||
muß die Wechselreichter-Seriennummer gesetzt werden um den Wechselrichter der Device-Definition eindeutig zuzuweisen.
|
||||
Ist nur ein Wechselrichter vorhanden und das Attribut nicht gesetzt, wird es automatisch definiert sobald die
|
||||
Seriennummer des Wechselrichters erkannt wurde.
|
||||
(default: 0xFFFFFFFF = keine Einschränkung)
|
||||
</li>
|
||||
<br>
|
||||
|
||||
<a name="target-susyid"></a>
|
||||
<li><b>target-susyid </b><br>
|
||||
Im Falle eines Multigate muss die Ziel-SUSyID definiert werden. Ist mehr als ein Wechselrichter installiert,
|
||||
muß die Wechselreichter-SUSyID gesetzt werden um den Wechselrichter der Device-Definition eindeutig zuzuweisen.
|
||||
Ist nur ein Wechselrichter vorhanden und das Attribut nicht gesetzt, wird es automatisch definiert sobald die
|
||||
SUSyID des Wechselrichters erkannt wurde.
|
||||
(default: 0xFFFF = keine Einschränkung)
|
||||
</li>
|
||||
<br>
|
||||
|
||||
<a name="timeout"></a>
|
||||
<li><b>timeout </b><br>
|
||||
Einstellung des timeout für die Wechselrichterabfrage in Sekunden. (default 60)
|
||||
</li>
|
||||
<br>
|
||||
|
||||
</ul>
|
||||
|
||||