76_SMAInverter.pm: contrib 2.12.0

git-svn-id: https://svn.fhem.de/fhem/trunk@20013 2b470e98-0d58-463d-a4d8-8e2adae1ed80
This commit is contained in:
nasseeder1 2019-08-18 16:21:59 +00:00
parent 896cbf52ad
commit 76d2264f67

View File

@ -28,7 +28,9 @@
#################################################################################################################
# Versions History by DS_Starter
#
# 2.11.0 17.08.2019 attr target-serial, target-susyid are set automatically if not defined
#
# 2.12.0 18.08.2019 set warning to log if SPOT_ETODAY, SPOT_ETOTAL was not delivered (SMA_command), Forum: https://forum.fhem.de/index.php/topic,56080.msg967823.html#msg967823
# 2.11.0 17.08.2019 attr target-serial, target-susyid are set automatically if not defined, commandref revised
# 2.10.2 14.08.2019 new types to %SMAInverter_devtypes
# 2.10.1 28.04.2019 fix perl warnings, Forum:#56080.msg933276.html#msg933276
# 2.10.0 29.06.2018 Internal MODEL added
@ -85,7 +87,7 @@ use Time::HiRes qw(gettimeofday tv_interval);
use Blocking;
use Time::Local;
my $SMAInverterVersion = "2.10.2";
my $SMAInverterVersion = "2.12.0";
# Inverter Data fields and supported commands flags.
# $inv_SPOT_ETODAY # Today yield
@ -1117,8 +1119,16 @@ sub SMA_command($$$$$) {
Log3 $name, 5, "$name - Data identifier $data_ID";
if($data_ID eq 0x2601) {
$inv_SPOT_ETOTAL = unpack("V*", substr($data, 62, 4));
$inv_SPOT_ETODAY = unpack("V*", substr $data, 78, 4);
eval { $inv_SPOT_ETOTAL = unpack("V*", substr($data, 62, 4)); };
if ($@) {
Log3 $name, 3, "$name - WARNING - SPOT_ETOTAL wasn't deliverd ... set it to \"0\" !";
$inv_SPOT_ETOTAL = 0;
}
eval { $inv_SPOT_ETODAY = unpack("V*", substr $data, 78, 4); };
if ($@) {
Log3 $name, 3, "$name - WARNING - SPOT_ETODAY wasn't deliverd ... set it to \"0\" !";
$inv_SPOT_ETODAY = 0;
}
Log3 $name, 5, "$name - Found Data SPOT_ETOTAL=$inv_SPOT_ETOTAL and SPOT_ETODAY=$inv_SPOT_ETODAY";
return (1,$inv_SPOT_ETODAY,$inv_SPOT_ETOTAL,$inv_susyid,$inv_serial);
}
@ -1629,31 +1639,113 @@ The retrieval of the inverter will be executed non-blocking. You can adjust the
<b>Get</b>
<br>
<ul>
<code>get &lt;name&gt; data</code>
<br><br>
The request of the inverter will be executed. Those possibility is especifically created for the "manual" operation mode (see attribute "mode").
<li><b> get &lt;name&gt; data </b>
<br><br>
The request of the inverter will be executed. Those possibility is especifically created for the "manual" operation
mode (see attribute "mode").
<br>
</li>
<br>
</ul>
<b>Attributes</b>
<ul>
<li><b>interval</b> : Queryintreval in seconds </li>
<li><b>detail-level</b> : "0" - Only Power and Energy / "1" - Including Voltage and Current / "2" - All values </li>
<li><b>disable</b> : 1 = the module is disabled </li>
<li><b>mode</b> : automatic = the inverter will be polled by preset interval, manual = query only by command "get &lt;name&gt; data" </li>
<li><b>offset</b> : time in seconds to prefer the sunrise respectively defer the sunset virtualy (0 ... 7200). You will be able to extend the working
period of the module. </li>
<li><b>SBFSpotComp</b> : 1 = the readings are created like SBFSpot-style </li>
<li><b>suppressSleep</b> : the sleep mode (after sunset, before sunrise) is deactivated and the inverter will be polled continuously. </li>
<li><b>showproctime</b> : shows processing time in background and wasted time to retrieve inverter data </li>
<li><b>target-susyid</b> : In case of a Multigate the target SUSyID can be defined. If more than one inverter is installed you have to
set the inverter-SUSyID to assign the inverter to the device definition.
Default is 0xFFFF, means any SUSyID</li>
<li><b>target-serial</b> : In case of a Multigate the target Serialnumber can be defined. If more than one inverter is installed you have to
set the inverter-Serialnumber to assign the inverter to the device definition.
Default is 0xFFFFFFFF, means any Serialnumber</li>
<li><b>timeout</b> : setup timeout of inverter data request (default 60s) </li>
<a name="detail-level"></a>
<li><b>detail-level [0|1|2] </b><br>
Defines the complexity of the generated readings. <br><br>
<ul>
<table>
<colgroup> <col width=10%> <col width=90%> </colgroup>
<tr><td> 0 </td><td>- only Power and Energy </td></tr>
<tr><td> 1 </td><td>- as 0, additional voltage and current </td></tr>
<tr><td> 2 </td><td>- all values </td></tr>
</table>
</ul>
</li>
<br>
<a name="disable"></a>
<li><b>disable [1|0]</b><br>
Deactivate/activate the module.
</li>
<br>
<a name="interval"></a>
<li><b>interval </b><br>
Request cycle in seconds. (default: 60)
</li>
<br>
<a name="mode"></a>
<li><b>mode [automatic|manual] </b><br>
The request mode of the inverter. (default: automatic) <br><br>
<ul>
<table>
<colgroup> <col width=10%> <col width=90%> </colgroup>
<tr><td> automatic </td><td>- the inverter will be polled regularly as defined by attribute "interval" </td></tr>
<tr><td> manual </td><td>- query only by command "get &lt;name&gt; data" </td></tr>
</table>
</ul>
</li>
<br>
<a name="offset"></a>
<li><b>offset &lt;0 - 7200&gt; </b><br>
Time in seconds to forward the real sunrise respectively defer the real sunset.
You will be able to extend the working period of the module.
</li>
<br>
<a name="SBFSpotComp"></a>
<li><b>SBFSpotComp [1|0]</b><br>
The reading names are created like the SBFSpot-style. (default: 0)
</li>
<br>
<a name="showproctime"></a>
<li><b>showproctime [1|0]</b><br>
Shows the processing time in background and the wasted time to retrieve inverter data. (default: 0)
</li>
<br>
<a name="suppressSleep"></a>
<li><b>suppressSleep [1|0]</b><br>
The sleep mode (after sunset and before sunrise) is deactivated and the inverter will be polled continuously. (default: 0)
</li>
<br>
<a name="target-serial"></a>
<li><b>target-serial </b><br>
In case of a Multigate the target serial number has to be defined. If more than one inverter is installed,
you have to set the inverter serial number to assign the inverter to the device definition.
If only one inverter available, the attribut is set automatically once the serial number of the inverter was detected.
(default: 0xFFFFFFFF = means any serial number)
</li>
<br>
<a name="target-susyid"></a>
<li><b>target-susyid </b><br>
In case of a Multigate the target SUSyID has to be defined. If more than one inverter is installed,
you have to set the inverter-SUSyID to assign the inverter to the device definition.
If only one inverter available, the attribut is set automatically once the SUSyID of the inverter was detected.
(default: 0xFFFF = means any SUSyID)
</li>
<br>
<a name="timeout"></a>
<li><b>timeout </b><br>
Setup timeout of inverter data request in seconds. (default 60)
</li>
<br>
</ul>
<b>Readings</b>
@ -1778,31 +1870,115 @@ Die Abfrage des Wechselrichters wird non-blocking ausgeführt. Der Timeoutwert f
<b>Get</b>
<br>
<ul>
<code>get &lt;name&gt; data</code>
<br><br>
Die Datenabfrage des Wechselrichters wird ausgeführt. Diese Möglichkeit ist speziell für den Betriebsmodus "manual" vorgesehen (siehe Attribut "mode").
<li><b> get &lt;name&gt; data </b>
<br><br>
Die Datenabfrage des Wechselrichters wird ausgeführt. Diese Möglichkeit ist speziell für den Betriebsmodus "manual"
vorgesehen (siehe Attribut "mode").
<br>
</li>
<br>
</ul>
<b>Attribute</b>
<br<br>
<ul>
<li><b>interval</b> : Abfrageinterval in Sekunden </li>
<li><b>detail-level</b> : "0" - Nur Leistung und Energie / "1" - zusätzlich Strom und Spannung / "2" - Alle Werte </li>
<li><b>disable</b> : 1 = das Modul ist disabled </li>
<li><b>mode</b> : automatic = die Wechselrichterwerte werden im eingestellten Interval abgefragt, manual = Abfrage nur mit "get &lt;name&gt; data" </li>
<li><b>offset</b> : Zeit in Sekunden um die der Sonnenaufgang vorgezogen bzw. Sonnenuntergang verzögert wird (0 ... 7200). Dadurch wird die
effektive Aktivzeit des Moduls erweitert. </li>
<li><b>suppressSleep</b> : der Schlafmodus (nach Sonnenuntergang, vor Sonnenaufgang) wird ausgeschaltet und der WR abgefragt. </li>
<li><b>showproctime</b> : zeigt die für den Hintergrundprozess und die Abfrage des Wechselrichter verbrauchte Zeit. </li>
<li><b>SBFSpotComp</b> : 1 = die Readings werden kompatibel zu SBFSpot-Ausgaben erzeugt </li>
<li><b>target-susyid</b> : Im Falle eines Multigate kann die Ziel-SUSyID definiert werden. Ist mehr als ein Wechselrichter installiert,
muß die Wechselreichter-SUSyID gesetzt werden um den Wechselrichter der Device-Definition eindeutig zuzuweisen.
Default ist 0xFFFF (=keine Einschränkung)</li>
<li><b>target-serial</b> : Im Falle eines Multigate kann die Ziel-Seriennummer definiert werden. Ist mehr als ein Wechselrichter installiert,
muß die Wechselreichter-Seriennummer gesetzt werden um den Wechselrichter der Device-Definition eindeutig zuzuweisen.
Default ist 0xFFFFFFFF (=keine Einschränkung)</li>
<li><b>timeout</b> : Einstellung des timeout für die Wechselrichterabfrage (default 60s) </li>
<a name="detail-level"></a>
<li><b>detail-level [0|1|2] </b><br>
Legt den Umfang der ausgegebenen Readings fest. <br><br>
<ul>
<table>
<colgroup> <col width=10%> <col width=90%> </colgroup>
<tr><td> 0 </td><td>- nur Leistung und Energie </td></tr>
<tr><td> 1 </td><td>- wie 0, zusätzlich Strom und Spannung </td></tr>
<tr><td> 2 </td><td>- alle Werte </td></tr>
</table>
</ul>
</li>
<br>
<a name="disable"></a>
<li><b>disable [1|0]</b><br>
Deaktiviert/aktiviert das Modul.
</li>
<br>
<a name="interval"></a>
<li><b>interval </b><br>
Abfrageinterval in Sekunden. (default: 60)
</li>
<br>
<a name="mode"></a>
<li><b>mode [automatic|manual] </b><br>
Abfragemodus des Wechselrichters. (default: automatic) <br><br>
<ul>
<table>
<colgroup> <col width=10%> <col width=90%> </colgroup>
<tr><td> automatic </td><td>- die Wechselrichterwerte werden im eingestellten Interval abgefragt (Attribut "interval") </td></tr>
<tr><td> manual </td><td>- Abfrage nur mit "get &lt;name&gt; data" </td></tr>
</table>
</ul>
</li>
<br>
<a name="offset"></a>
<li><b>offset &lt;0 - 7200&gt; </b><br>
Zeit in Sekunden, um die der reale Sonnenaufgang vorgezogen bzw. reale Sonnenuntergang verzögert wird.
Dadurch wird die effektive Aktivzeit des Moduls erweitert.
</li>
<br>
<a name="SBFSpotComp"></a>
<li><b>SBFSpotComp [1|0]</b><br>
Die Readingnamen werden kompatibel zu SBFSpot-Ausgaben erzeugt. (default: 0)
</li>
<br>
<a name="showproctime"></a>
<li><b>showproctime [1|0]</b><br>
Zeigt die für den Hintergrundprozess und die Abfrage des Wechselrichter verbrauchte Zeit. (default: 0)
</li>
<br>
<a name="suppressSleep"></a>
<li><b>suppressSleep [1|0]</b><br>
Der Schlafmodus (nach Sonnenuntergang und vor Sonnenaufgang) wird ausgeschaltet und der WR abgefragt. (default: 0)
</li>
<br>
<a name="target-serial"></a>
<li><b>target-serial </b><br>
Im Falle eines Multigate muss die Ziel-Seriennummer definiert werden. Ist mehr als ein Wechselrichter installiert,
muß die Wechselreichter-Seriennummer gesetzt werden um den Wechselrichter der Device-Definition eindeutig zuzuweisen.
Ist nur ein Wechselrichter vorhanden und das Attribut nicht gesetzt, wird es automatisch definiert sobald die
Seriennummer des Wechselrichters erkannt wurde.
(default: 0xFFFFFFFF = keine Einschränkung)
</li>
<br>
<a name="target-susyid"></a>
<li><b>target-susyid </b><br>
Im Falle eines Multigate muss die Ziel-SUSyID definiert werden. Ist mehr als ein Wechselrichter installiert,
muß die Wechselreichter-SUSyID gesetzt werden um den Wechselrichter der Device-Definition eindeutig zuzuweisen.
Ist nur ein Wechselrichter vorhanden und das Attribut nicht gesetzt, wird es automatisch definiert sobald die
SUSyID des Wechselrichters erkannt wurde.
(default: 0xFFFF = keine Einschränkung)
</li>
<br>
<a name="timeout"></a>
<li><b>timeout </b><br>
Einstellung des timeout für die Wechselrichterabfrage in Sekunden. (default 60)
</li>
<br>
</ul>
<b>Readings</b>