10_IT.pm: Update english docu. Return undef if message is not for IT
git-svn-id: https://svn.fhem.de/fhem/trunk@8100 2b470e98-0d58-463d-a4d8-8e2adae1ed80
This commit is contained in:
parent
97473538ba
commit
6c7a28f35d
@ -356,9 +356,13 @@ IT_Parse($$)
|
||||
my $def;
|
||||
my $newstate;
|
||||
my @list;
|
||||
if ((substr($msg, 0, 1)) ne 'i') {
|
||||
Log3 undef,4,"message not supported by IT \"$msg\"!";
|
||||
return undef;
|
||||
}
|
||||
if (length($msg) != 7 && length($msg) != 17) {
|
||||
Log3 undef,3,"message \"$msg\" to short!";
|
||||
return "message \"$msg\" to short!";
|
||||
Log3 undef,3,"message \"$msg\" too short!";
|
||||
return undef;
|
||||
}
|
||||
my $bin = undef;
|
||||
if ( length($msg) == 17 ) {
|
||||
@ -464,13 +468,13 @@ IT_Parse($$)
|
||||
<h3>IT - InterTechno</h3>
|
||||
<ul>
|
||||
The InterTechno 433MHZ protocol is used by a wide range of devices, which are either of
|
||||
the sender/sensor category or the receiver/actuator category. As we right now
|
||||
able to SEND and RECEIVE InterTechno commands
|
||||
supports just devices like switches, dimmers, etc. through an <a href="#CUL">CUL</a> device, so this must be defined first.
|
||||
the sender/sensor or the receiver/actuator category.
|
||||
Right now, we are able to SEND and RECEIVE InterTechno commands.
|
||||
Supported are devices like switches, dimmers, etc. through an <a href="#CUL">CUL</a> device, this must be defined first.
|
||||
<br>
|
||||
This module supports Intertechno protocol version 1 and version 3.
|
||||
New received device packages are add in fhem category IT with autocreate.
|
||||
Hint: IT protocol 1 devices are only created at pressed on button.
|
||||
Newly found devices are added into the category "IT" by autocreate.
|
||||
Hint: IT protocol 1 devices are created on pressing the on-button.
|
||||
|
||||
<br><br>
|
||||
|
||||
@ -486,19 +490,19 @@ IT_Parse($$)
|
||||
<br><br>
|
||||
|
||||
The value of housecode is a 10-digit InterTechno Code, consisting of 0/1/F as it is
|
||||
defined as a tri-state protocol. These digits depend on your device you are using.
|
||||
defined as a tri-state protocol. These digits depend on the device you are using.
|
||||
<br>
|
||||
Bit 11/12 are used for switching/dimming. As different manufacturers are using
|
||||
Bit 11 and 12 are used for switching/dimming. As different manufacturers are using
|
||||
different bit-codes you can specifiy here the 2-digit code for off/on/dimup/dimdown
|
||||
in the same form: 0/1/F.
|
||||
<br>
|
||||
The value of ITRotarySwitches consist of the value of the alpha switch A-P and
|
||||
The value of ITRotarySwitches consists of the value of the alpha switch A-P and
|
||||
the numeric switch 1-16 as set on the intertechno device. E.g. A1 or G12.
|
||||
<br>
|
||||
The value of FLS100RotarySwitches consist of the value of the I,II,II,IV switch
|
||||
and the numeric 1,2,3,4 swicht. E.g. I2 or IV4.
|
||||
<br>
|
||||
The value of ITRotarySwitches and FLS100RotarySwitches is internaly translated
|
||||
The value of ITRotarySwitches and FLS100RotarySwitches are internaly translated
|
||||
into a houscode value.
|
||||
|
||||
<ul>
|
||||
@ -526,7 +530,8 @@ Examples:
|
||||
<code>define lamp IT II2</code><br>
|
||||
</ul>
|
||||
<br>
|
||||
For Intertechno protocol 3 is the <housecode> a 26-digits number. Additionaly there are a 4-digits unit code and a 1-digit group code used.
|
||||
For Intertechno protocol 3 the <housecode> is a 26-digits number.
|
||||
Additionaly there are a 4-digits unit code and a 1-digit group code used.
|
||||
<ul>
|
||||
<li><code><address></code> is a 26 digit number (0/1)</li>
|
||||
<li><code><group></code> is a 1 digit number (0/1)</li>
|
||||
@ -566,9 +571,8 @@ Examples:
|
||||
Notes:
|
||||
<ul>
|
||||
<li>on-till requires an absolute time in the "at" format (HH:MM:SS, HH:MM
|
||||
or { <perl code> }, where the perl-code returns a time
|
||||
specification).
|
||||
If the current time is greater than the specified time, then the
|
||||
or { <perl code> }, where the perl-code returns a time specification).
|
||||
If the current time is greater than the specified time, the
|
||||
command is ignored, else an "on" command is generated, and for the
|
||||
given "till-time" an off command is scheduleld via the at command.
|
||||
</li>
|
||||
@ -583,18 +587,19 @@ Examples:
|
||||
<ul>
|
||||
<a name="IODev"></a>
|
||||
<li>IODev<br>
|
||||
Set the IO or physical device which should be used for sending signals
|
||||
for this "logical" device. An example for the physical device is a CUL.
|
||||
Note: Upon startup fhem DOES NOT assigns an InterTechno device an
|
||||
IODevice! The attribute IODev needs to be used AT ANY TIME!</li><br>
|
||||
Set the IO device which will be used to send signals
|
||||
for this device. An example for the physical device is a CUL.
|
||||
Note: On startup, fhem DOES NOT assign an InterTechno device to an
|
||||
IODevice! The attribute IODev needs to be used ALWAYS!</li><br>
|
||||
|
||||
<a name="eventMap"></a>
|
||||
<li>eventMap<br>
|
||||
Replace event names and set arguments. The value of this attribute
|
||||
consists of a list of space separated values, each value is a colon
|
||||
consists of a list of space separated values. Each value is a colon
|
||||
separated pair. The first part specifies the "old" value, the second
|
||||
the new/desired value. If the first character is slash(/) or komma(,)
|
||||
then split not by space but by this character, enabling to embed spaces.
|
||||
the new/desired value. If the first character is slash(/) or comma(,)
|
||||
the values are not separated by space but by this character to
|
||||
enable spaces in values.
|
||||
Examples:<ul><code>
|
||||
attr store eventMap on:open off:closed<br>
|
||||
attr store eventMap /on-for-timer 10:open/off:closed/<br>
|
||||
@ -617,16 +622,16 @@ Examples:
|
||||
|
||||
<a name="model"></a>
|
||||
<li>model<br>
|
||||
The model attribute denotes the model type of the device.
|
||||
The attributes will (currently) not be used by the fhem.pl directly.
|
||||
The model attribute denotes the type of the device.
|
||||
This attribute will (currently) not be used by fhem.pl directly.
|
||||
It can be used by e.g. external programs or web interfaces to
|
||||
distinguish classes of devices and send the appropriate commands
|
||||
(e.g. "on" or "off" to a switch, "dim..%" to dimmers etc.).
|
||||
The spelling of the model names are as quoted on the printed
|
||||
documentation which comes which each device. This name is used
|
||||
without blanks in all lower-case letters. Valid characters should be
|
||||
The spelling of the model should match the modelname used in the
|
||||
documentation that comes which the device. The name should consist of
|
||||
lower-case characters without spaces. Valid characters are
|
||||
<code>a-z 0-9</code> and <code>-</code> (dash),
|
||||
other characters should be ommited. Here is a list of "official"
|
||||
other characters should not be used. Here is a list of "official"
|
||||
devices:<br>
|
||||
<b>Sender/Sensor</b>: itremote<br>
|
||||
|
||||
@ -639,11 +644,11 @@ Examples:
|
||||
<a name="ignore"></a>
|
||||
<li>ignore<br>
|
||||
Ignore this device, e.g. if it belongs to your neighbour. The device
|
||||
won't trigger any FileLogs/notifys, issued commands will silently
|
||||
won't trigger any FileLogs/notifys, issued commands will be silently
|
||||
ignored (no RF signal will be sent out, just like for the <a
|
||||
href="#attrdummy">dummy</a> attribute). The device won't appear in the
|
||||
list command (only if it is explicitely asked for it), nor will it
|
||||
appear in commands which use some wildcard/attribute as name specifiers
|
||||
be affected by commands which use wildcards or attributes as name specifiers
|
||||
(see <a href="#devspec">devspec</a>). You still get them with the
|
||||
"ignored=1" special devspec.
|
||||
</li><br>
|
||||
@ -654,7 +659,7 @@ Examples:
|
||||
<a name="ITevents"></a>
|
||||
<b>Generated events:</b>
|
||||
<ul>
|
||||
From an IT device you can receive one of the following events.
|
||||
From an IT device you can receive the following events.
|
||||
<li>on</li>
|
||||
<li>off</li>
|
||||
<li>dimdown</li>
|
||||
|
Loading…