98_ModbusAttr.pm: updated documentation for new features of the base module 98_Modbus.pm
git-svn-id: https://svn.fhem.de/fhem/trunk@11817 2b470e98-0d58-463d-a4d8-8e2adae1ed80
This commit is contained in:
parent
ce92d6678f
commit
6888733daf
@ -26,6 +26,10 @@
|
|||||||
# 2015-03-09 initial release
|
# 2015-03-09 initial release
|
||||||
# 2015-07-22 added documentation for new features introduced in the base module 98_Modbus.pm
|
# 2015-07-22 added documentation for new features introduced in the base module 98_Modbus.pm
|
||||||
# that can be used here.
|
# that can be used here.
|
||||||
|
# 2016-04-16 Load Modbus base module instead of require - avoids messages when fhem reloads Modbus
|
||||||
|
# because a serial Modbus device is defined afterwards
|
||||||
|
# 2016-06-18 added documentation for alignTime and enableControlSet (implemented in the base module 98_Modbus.pm)
|
||||||
|
# 2016-07-07 added documentatoin for nextOpenDelay
|
||||||
#
|
#
|
||||||
|
|
||||||
package main;
|
package main;
|
||||||
@ -39,7 +43,8 @@ ModbusAttr_Initialize($)
|
|||||||
{
|
{
|
||||||
my ($modHash) = @_;
|
my ($modHash) = @_;
|
||||||
|
|
||||||
require "$attr{global}{modpath}/FHEM/98_Modbus.pm";
|
#require "$attr{global}{modpath}/FHEM/98_Modbus.pm";
|
||||||
|
LoadModule "Modbus";
|
||||||
require "$attr{global}{modpath}/FHEM/DevIo.pm";
|
require "$attr{global}{modpath}/FHEM/DevIo.pm";
|
||||||
|
|
||||||
ModbusLD_Initialize($modHash); # Generic function of the Modbus module does the rest
|
ModbusLD_Initialize($modHash); # Generic function of the Modbus module does the rest
|
||||||
@ -94,7 +99,8 @@ ModbusAttr_Initialize($)
|
|||||||
<a name="ModbusAttrConfiguration"></a>
|
<a name="ModbusAttrConfiguration"></a>
|
||||||
<b>Configuration of the module</b><br><br>
|
<b>Configuration of the module</b><br><br>
|
||||||
<ul>
|
<ul>
|
||||||
The data objects (holding registers, input registers, coils or discrete inputs) of the device to be queried are defined using attributes. The attributes assign objects with their address to readings inside fhem and control
|
The data objects (holding registers, input registers, coils or discrete inputs) of the device to be queried are defined using attributes.
|
||||||
|
The attributes assign objects with their address to readings inside fhem and control
|
||||||
how these readings are calculated from the raw values and how they are formatted.<br>
|
how these readings are calculated from the raw values and how they are formatted.<br>
|
||||||
Objects can also be written to the device and attributes define how this is done.<br><br>
|
Objects can also be written to the device and attributes define how this is done.<br><br>
|
||||||
|
|
||||||
@ -128,17 +134,31 @@ ModbusAttr_Initialize($)
|
|||||||
|
|
||||||
Attributes to define data objects start with obj- followed by a code that identifies the type and address
|
Attributes to define data objects start with obj- followed by a code that identifies the type and address
|
||||||
of the data object. <br>
|
of the data object. <br>
|
||||||
Modbus devices offer the following types of data objects: holding registers (16 bit objects that can be read and written), input registers (16 bit objects that can only be read), coils (single bit objects that can be read and written) or discrete inputs (single bit objects that can only be read). <br>
|
Modbus devices offer the following types of data objects: holding registers (16 bit objects that can be read and written),
|
||||||
The module uses the first character of these data object types to define attributes. Thus h770 refers to a holding register with the decimal address 770 and c120 refers to a coil with address 120. The address has to be specified as pure decimal number without any leading zeros or spaces.<br><br>
|
input registers (16 bit objects that can only be read), coils (single bit objects that can be read and written)
|
||||||
|
or discrete inputs (single bit objects that can only be read).
|
||||||
|
<br>
|
||||||
|
The module uses the first character of these data object types to define attributes.
|
||||||
|
Thus h770 refers to a holding register with the decimal address 770 and c120 refers to a coil with address 120.
|
||||||
|
The address has to be specified as pure decimal number without any leading zeros or spaces.<br><br>
|
||||||
|
|
||||||
<code>attr PWP obj-h258-reading Temp_Wasser_Aus</code> defines a reading with the name Temp_Wasser_Aus that is read from the Modbus holding register at address 258.<br>
|
<code>attr PWP obj-h258-reading Temp_Wasser_Aus</code> defines a reading with the name Temp_Wasser_Aus that is read from the Modbus holding register at address 258.<br>
|
||||||
With the attribute ending on <code>-expr</code> you can define a perl expression to do some conversion or calculation on the raw value read from the device. In the above example the raw value has to be devided by 10 to get the real value.<br><br>
|
With the attribute ending on <code>-expr</code> you can define a perl expression to do some conversion or calculation on the raw value read from the device.
|
||||||
|
In the above example the raw value has to be devided by 10 to get the real value.<br><br>
|
||||||
|
|
||||||
An object attribute ending on <code>-set</code> creates a fhem set option. In the above example the reading Temp_Soll can be changed to 12 degrees by the user with the fhem command <code>set PWP Temp_Soll 12</code><br>
|
An object attribute ending on <code>-set</code> creates a fhem set option.
|
||||||
The object attributes ending on <code>-min</code> and <code>-max</code> define min and max values for input validation and the attribute ending on <code>-hint</code> will tell fhem to create a selection list so the user can graphically select the defined values.<br><br>
|
In the above example the reading Temp_Soll can be changed to 12 degrees by the user with the fhem command <code>set PWP Temp_Soll 12</code><br>
|
||||||
|
The object attributes ending on <code>-min</code> and <code>-max</code> define min and max values for input validation
|
||||||
|
and the attribute ending on <code>-hint</code> will tell fhem to create a selection list so the user can graphically select the defined values.<br><br>
|
||||||
|
|
||||||
To define general properties of the device you can specify attributes starting with <code>dev-</code>. E.g. with <code>dev-timing-timeout</code> you can specify the timeout when waiting for a response from the device. With <code>dev-h-</code> you can specify several default values or general settings for all holding registers like the function code to be used when reading or writing holding registers. These attributes are optional and the module will use defaults that work in most cases. <br>
|
To define general properties of the device you can specify attributes starting with <code>dev-</code>.
|
||||||
<code>dev-h-combine 5</code> for example allows the module to combine read requests to objects having an address that differs 5 or less into one read request. Without setting this attribute the module will start individual read requests for each object. Typically the documentation for the modbus interface of a given device states the maximum number of objects that can be read in one function code 3 request.
|
E.g. with <code>dev-timing-timeout</code> you can specify the timeout when waiting for a response from the device.
|
||||||
|
With <code>dev-h-</code> you can specify several default values or general settings for all holding registers
|
||||||
|
like the function code to be used when reading or writing holding registers.
|
||||||
|
These attributes are optional and the module will use defaults that work in most cases. <br>
|
||||||
|
<code>dev-h-combine 5</code> for example allows the module to combine read requests to objects having an address that differs 5 or less into one read request.
|
||||||
|
Without setting this attribute the module will start individual read requests for each object.
|
||||||
|
Typically the documentation for the modbus interface of a given device states the maximum number of objects that can be read in one function code 3 request.
|
||||||
</ul>
|
</ul>
|
||||||
|
|
||||||
<a name="ModbusAttrSet"></a>
|
<a name="ModbusAttrSet"></a>
|
||||||
@ -152,7 +172,8 @@ ModbusAttr_Initialize($)
|
|||||||
<b>Get-Commands</b><br>
|
<b>Get-Commands</b><br>
|
||||||
<ul>
|
<ul>
|
||||||
All readings are also available as Get commands. Internally a Get command triggers the corresponding
|
All readings are also available as Get commands. Internally a Get command triggers the corresponding
|
||||||
request to the device and then interprets the data and returns the right field value. To avoid huge option lists in FHEMWEB, the objects visible as Get in FHEMWEB can be defined by setting an attribute <code>obj-xy-showget</code> to 1.
|
request to the device and then interprets the data and returns the right field value.
|
||||||
|
To avoid huge option lists in FHEMWEB, the objects visible as Get in FHEMWEB can be defined by setting an attribute <code>obj-xy-showget</code> to 1.
|
||||||
</ul>
|
</ul>
|
||||||
<br>
|
<br>
|
||||||
<a name="ModbusAttrattr"></a>
|
<a name="ModbusAttrattr"></a>
|
||||||
@ -161,8 +182,18 @@ ModbusAttr_Initialize($)
|
|||||||
<li><a href="#do_not_notify">do_not_notify</a></li>
|
<li><a href="#do_not_notify">do_not_notify</a></li>
|
||||||
<li><a href="#readingFnAttributes">readingFnAttributes</a></li>
|
<li><a href="#readingFnAttributes">readingFnAttributes</a></li>
|
||||||
<br>
|
<br>
|
||||||
|
<li><b>alignTime</b></li>
|
||||||
|
Aligns each periodic read request for the defined interval to this base time. This is typcally something like 00:00 (see the Fhem at command)
|
||||||
|
<li><b>enableControlSet</b></li>
|
||||||
|
enables the built in set commands interval, stop, start and reread
|
||||||
|
|
||||||
|
<br>
|
||||||
|
please also notice the attributes for the physical modbus interface as documented in 98_Modbus.pm
|
||||||
|
<br>
|
||||||
|
|
||||||
the following list of attributes can be applied to any data object by specifying the objects type and address in the variable part.
|
the following list of attributes can be applied to any data object by specifying the objects type and address in the variable part.
|
||||||
For many attributes you can also specify default values per object type (see dev- attributes later) or you can specify an object attribute without type and address (e.g. obj-len) which then applies as default for all objects:
|
For many attributes you can also specify default values per object type (see dev- attributes later) or you can specify an object attribute without type and address
|
||||||
|
(e.g. obj-len) which then applies as default for all objects:
|
||||||
<li><b>obj-[cdih][1-9][0-9]*-reading</b></li>
|
<li><b>obj-[cdih][1-9][0-9]*-reading</b></li>
|
||||||
define the name of a reading that corresponds to the modbus data object of type c,d,i or h and a decimal address (e.g. obj-h225-reading).
|
define the name of a reading that corresponds to the modbus data object of type c,d,i or h and a decimal address (e.g. obj-h225-reading).
|
||||||
<br>
|
<br>
|
||||||
@ -185,19 +216,28 @@ ModbusAttr_Initialize($)
|
|||||||
defines a perl expression that converts the raw value read from the device.
|
defines a perl expression that converts the raw value read from the device.
|
||||||
<br>
|
<br>
|
||||||
<li><b>obj-[cdih][1-9][0-9]*-map</b></li>
|
<li><b>obj-[cdih][1-9][0-9]*-map</b></li>
|
||||||
defines a map to convert values read from the device to more convenient values when the raw value is read from the device or back when the value to write has to be converted from the user value to a raw value that can be written. Example: 0:mittig, 1:oberhalb, 2:unterhalb
|
defines a map to convert values read from the device to more convenient values when the raw value is read from the device
|
||||||
|
or back when the value to write has to be converted from the user value to a raw value that can be written.
|
||||||
|
Example: 0:mittig, 1:oberhalb, 2:unterhalb
|
||||||
<br>
|
<br>
|
||||||
<li><b>obj-[cdih][1-9][0-9]*-setexpr</b></li>
|
<li><b>obj-[cdih][1-9][0-9]*-setexpr</b></li>
|
||||||
defines a perl expression that converts the user specified value in a set to a raw value that can be sent to the device. This is typically the inversion of -expr above.
|
defines a perl expression that converts the user specified value in a set to a raw value that can be sent to the device.
|
||||||
|
This is typically the inversion of -expr above.
|
||||||
<br>
|
<br>
|
||||||
<li><b>obj-[cdih][1-9][0-9]*-format</b></li>
|
<li><b>obj-[cdih][1-9][0-9]*-format</b></li>
|
||||||
defines a format string to format the value read e.g. %.1f
|
defines a format string to format the value read e.g. %.1f
|
||||||
<br>
|
<br>
|
||||||
<li><b>obj-[cdih][1-9][0-9]*-len</b></li>
|
<li><b>obj-[cdih][1-9][0-9]*-len</b></li>
|
||||||
defines the length of the data object in registers. It defaults to 1. Some devices store 32 bit floating point values in two registers. In this case you can set this attribute to two.
|
defines the length of the data object in registers. It defaults to 1.
|
||||||
|
Some devices store 32 bit floating point values in two registers. In this case you should set this attribute to two.
|
||||||
<br>
|
<br>
|
||||||
<li><b>obj-[cdih][1-9][0-9]*-unpack</b></li>
|
<li><b>obj-[cdih][1-9][0-9]*-unpack</b></li>
|
||||||
defines the unpack code to convert the raw data string read from the device to a reading. For an unsigned integer in big endian format this would be "n", for a signed 16 bit integer in big endian format this would be "s>" and for a 32 bit big endian float value this would be "f>". (see the perl documentation of the pack function).
|
defines the unpack code to convert the raw data string read from the device to a reading.
|
||||||
|
For an unsigned integer in big endian format this would be "n",
|
||||||
|
for a signed 16 bit integer in big endian format this would be "s>"
|
||||||
|
and for a 32 bit big endian float value this would be "f>". (see the perl documentation of the pack function).<br>
|
||||||
|
Please note that you also have to set a -len attribute (for this object or for the device) if you specify an unpack code that consumes data from more than one register.<br>
|
||||||
|
For a 32 bit float len should be at least 2.
|
||||||
<br>
|
<br>
|
||||||
<li><b>obj-[cdih][1-9][0-9]*-revRegs</b></li>
|
<li><b>obj-[cdih][1-9][0-9]*-revRegs</b></li>
|
||||||
this is only applicable to objects that span several input registers or holding registers. <br>
|
this is only applicable to objects that span several input registers or holding registers. <br>
|
||||||
@ -206,33 +246,45 @@ ModbusAttr_Initialize($)
|
|||||||
<br>
|
<br>
|
||||||
<li><b>obj-[cdih][1-9][0-9]*-bswapRegs</b></li>
|
<li><b>obj-[cdih][1-9][0-9]*-bswapRegs</b></li>
|
||||||
this is applicable to objects that span several input or holding registers. <br>
|
this is applicable to objects that span several input or holding registers. <br>
|
||||||
after the registers have been read, all 16-bit values are treated big-endian and are reversed to little-endian by swapping the two 8 bit bytes. This functionality is most likely used for reading (ASCII) strings from the device that are stored as big-endian 16-bit values. <br>
|
after the registers have been read, all 16-bit values are treated big-endian and are reversed to little-endian by swapping the two 8 bit bytes.
|
||||||
|
This functionality is most likely used for reading (ASCII) strings from the device that are stored as big-endian 16-bit values. <br>
|
||||||
example: original reading is "324d3130203a57577361657320722020". After applying bswapRegs, the value will be "4d3230313a2057576173736572202020"
|
example: original reading is "324d3130203a57577361657320722020". After applying bswapRegs, the value will be "4d3230313a2057576173736572202020"
|
||||||
which will result in the ASCII string "M201: WWasser ". Should be used with "(a*)" as -unpack value.
|
which will result in the ASCII string "M201: WWasser ". Should be used with "(a*)" as -unpack value.
|
||||||
<br>
|
<br>
|
||||||
<li><b>obj-[cdih][1-9][0-9]*-decode</b></li>
|
<li><b>obj-[cdih][1-9][0-9]*-decode</b></li>
|
||||||
defines an encoding to be used in a call to the perl function decode to convert the raw data string read from the device to a reading. This can be used if the device delivers strings in an encoding like cp850 instead of utf8.
|
defines an encoding to be used in a call to the perl function decode to convert the raw data string read from the device to a reading.
|
||||||
|
This can be used if the device delivers strings in an encoding like cp850 instead of utf8.
|
||||||
<br>
|
<br>
|
||||||
<li><b>obj-[cdih][1-9][0-9]*-encode</b></li>
|
<li><b>obj-[cdih][1-9][0-9]*-encode</b></li>
|
||||||
defines an encoding to be used in a call to the perl function encode to convert the raw data string read from the device to a reading. This can be used if the device delivers strings in an encoding like cp850 and after decoding it you want to reencode it to e.g. utf8.
|
defines an encoding to be used in a call to the perl function encode to convert the raw data string read from the device to a reading.
|
||||||
|
This can be used if the device delivers strings in an encoding like cp850 and after decoding it you want to reencode it to e.g. utf8.
|
||||||
<br>
|
<br>
|
||||||
|
|
||||||
<li><b>obj-[cdih][1-9][0-9]*-showget</b></li>
|
<li><b>obj-[cdih][1-9][0-9]*-showget</b></li>
|
||||||
every reading can also be requested by a get command. However these get commands are not automatically offered in fhemweb. By specifying this attribute, the get will be visible in fhemweb.
|
every reading can also be requested by a get command. However these get commands are not automatically offered in fhemweb.
|
||||||
|
By specifying this attribute, the get will be visible in fhemweb.
|
||||||
<br>
|
<br>
|
||||||
<li><b>obj-[cdih][1-9][0-9]*-poll</b></li>
|
<li><b>obj-[cdih][1-9][0-9]*-poll</b></li>
|
||||||
if set to 1 then this obeject is included in the cyclic update request as specified in the define command. If not set, then the object can manually be requested with a get command, but it is not automatically updated each interval. Note that this setting can also be specified as default for all objects with the dev- atributes described later.
|
if set to 1 then this obeject is included in the cyclic update request as specified in the define command.
|
||||||
|
If not set, then the object can manually be requested with a get command, but it is not automatically updated each interval.
|
||||||
|
Note that this setting can also be specified as default for all objects with the dev- atributes described later.
|
||||||
<br>
|
<br>
|
||||||
<li><b>obj-[cdih][1-9][0-9]*-polldelay</b></li>
|
<li><b>obj-[cdih][1-9][0-9]*-polldelay</b></li>
|
||||||
this attribute allows to poll objects at a lower rate than the interval specified in the define command. you can either specify a time in seconds or number prefixed by "x" which means a multiple of the interval of the define command.<br>
|
this attribute allows to poll objects at a lower rate than the interval specified in the define command.
|
||||||
if you specify a normal numer then it is interpreted as minimal time between the last read and another automatic read. Please note that this does not create an individual interval timer. Instead the normal interval timer defined by the interval of the define command will check if this reading is due or not yet. So the effective interval will always be a multiple of the interval of the define.
|
You can either specify a time in seconds or number prefixed by "x" which means a multiple of the interval of the define command.<br>
|
||||||
|
If you specify a normal numer then it is interpreted as minimal time between the last read and another automatic read.
|
||||||
|
Please note that this does not create an additional interval timer.
|
||||||
|
Instead the normal interval timer defined by the interval of the define command will check if this reading is due or not yet.
|
||||||
|
So the effective interval will always be a multiple of the interval of the define.
|
||||||
<br>
|
<br>
|
||||||
<br>
|
<br>
|
||||||
<li><b>dev-([cdih]-)*read</b></li>
|
<li><b>dev-([cdih]-)*read</b></li>
|
||||||
specifies the function code to use for reading this type of object. The default is 3 for holding registers, 1 for coils, 2 for discrete inputs and 4 for input registers.
|
specifies the function code to use for reading this type of object.
|
||||||
|
The default is 3 for holding registers, 1 for coils, 2 for discrete inputs and 4 for input registers.
|
||||||
<br>
|
<br>
|
||||||
<li><b>dev-([cdih]-)*write</b></li>
|
<li><b>dev-([cdih]-)*write</b></li>
|
||||||
specifies the function code to use for writing this type of object. The default is 6 for holding registers and 5 for coils. Discrete inputs and input registers can not be written by definition.
|
specifies the function code to use for writing this type of object.
|
||||||
|
The default is 6 for holding registers and 5 for coils. Discrete inputs and input registers can not be written by definition.
|
||||||
<br>
|
<br>
|
||||||
<li><b>dev-([cdih]-)*combine</b></li>
|
<li><b>dev-([cdih]-)*combine</b></li>
|
||||||
defines how many adjacent objects can be read in one request. If not specified, the default is 1
|
defines how many adjacent objects can be read in one request. If not specified, the default is 1
|
||||||
@ -278,6 +330,14 @@ ModbusAttr_Initialize($)
|
|||||||
<li><b>dev-timing-commDelay</b></li>
|
<li><b>dev-timing-commDelay</b></li>
|
||||||
delay between the last read and a next request. Default ist 0.1 seconds.
|
delay between the last read and a next request. Default ist 0.1 seconds.
|
||||||
<br>
|
<br>
|
||||||
|
<li><b>nextOpenDelay</b></li>
|
||||||
|
delay for Modbus-TCP connections. This defines how long the module should wait after a failed TCP connection attempt before the next reconnection attempt. This defaults to 60 seconds.
|
||||||
|
|
||||||
|
<li><b>maxTimeoutsToReconnect</b></li>
|
||||||
|
this attribute is only valid for TCP connected devices. In such cases a disconnected device might stay undetected and lead to timeouts until the TCP connection is reopened. This attribute specifies after how many timeouts an automatic reconnect is tried.
|
||||||
|
<li><b>disable</b></li>
|
||||||
|
stop communication with the device while this attribute is set to 1
|
||||||
|
<br>
|
||||||
</ul>
|
</ul>
|
||||||
<br>
|
<br>
|
||||||
</ul>
|
</ul>
|
||||||
|