76_SolarForecast.pm: contrib 0.55.3

git-svn-id: https://svn.fhem.de/fhem/trunk@24936 2b470e98-0d58-463d-a4d8-8e2adae1ed80
This commit is contained in:
nasseeder1 2021-09-08 19:47:11 +00:00
parent 89d43b69d9
commit 61fe5e72d8

View File

@ -120,6 +120,7 @@ BEGIN {
# Versions History intern
my %vNotesIntern = (
"0.55.3" => "08.09.2021 add powerthreshold to etotal key ",
"0.55.2" => "08.09.2021 minor fixes, use Color ",
"0.55.1" => "05.09.2021 delete invalid consumer index, Forum: https://forum.fhem.de/index.php/topic,117864.msg1173219.html#msg1173219 ",
"0.55.0" => "04.09.2021 new key pcurr for attr customerXX ",
@ -2633,11 +2634,12 @@ sub _manageConsumerData {
my $enread = $acref->{$c}{retotal};
my $u = $acref->{$c}{uetotal};
if($enread) {
my $eu = $u =~ /^kWh$/xi ? 1000 : 1;
my $etot = ReadingsNum ($consumer, $enread, 0) * $eu; # Summe Energieverbrauch des Verbrauchers
my $ehist = HistoryVal ($hash, $day, sprintf("%02d",$nhour), "csmt${c}", undef); # gespeicherter Totalverbrauch
my $eu = $u =~ /^kWh$/xi ? 1000 : 1;
my $etot = ReadingsNum ($consumer, $enread, 0) * $eu; # Summe Energieverbrauch des Verbrauchers
my $ehist = HistoryVal ($hash, $day, sprintf("%02d",$nhour), "csmt${c}", undef); # gespeicherter Totalverbrauch
my $pthreshold = ConsumerVal ($hash, $c, "powerthreshold", 0); # Schwellenwert (Wh pro Stunde) ab der ein Verbraucher als aktiv gewertet wird
if(defined $ehist && $etot >= $ehist) {
if(defined $ehist && $etot >= $ehist && ($etot - $ehist) >= $pthreshold) {
my $consumerco = $etot - $ehist;
$consumerco += HistoryVal ($hash, $day, sprintf("%02d",$nhour), "csme${c}", 0);
@ -3678,10 +3680,10 @@ sub collectAllRegConsumers {
my $alias = AttrVal ($consumer, "alias", $consumer);
my ($rtot,$utot);
my ($rtot,$utot,$pthreshold);
if(exists $hc->{etotal}) {
my $etotal = $hc->{etotal};
($rtot,$utot) = split ":",$etotal;
my $etotal = $hc->{etotal};
($rtot,$utot,$pthreshold) = split ":",$etotal;
}
my ($rpcurr,$upcurr);
@ -3697,24 +3699,25 @@ sub collectAllRegConsumers {
my $auto = 1;
$auto = ReadingsVal ($consumer, $rauto, 1) if($rauto); # Reading für Ready-Bit -> Einschalten möglich ?
$data{$type}{$name}{consumers}{$c}{name} = $consumer; # Name des Verbrauchers (Device)
$data{$type}{$name}{consumers}{$c}{alias} = $alias; # Alias des Verbrauchers (Device)
$data{$type}{$name}{consumers}{$c}{type} = $hc->{type} // $defctype; # Typ des Verbrauchers
$data{$type}{$name}{consumers}{$c}{power} = $hc->{power}; # Leistungsaufnahme des Verbrauchers in W
$data{$type}{$name}{consumers}{$c}{avgenergy} = $avgenergy; # Initialwert Energieverbrauch (evtl. Überschreiben in manageConsumerData)
$data{$type}{$name}{consumers}{$c}{mintime} = $hc->{mintime} // $hef{$ctype}{mt}; # Initialwert min. Einschalt- bzw. Zykluszeit (evtl. Überschreiben in manageConsumerData)
$data{$type}{$name}{consumers}{$c}{mode} = $hc->{mode} // $defcmode; # Planungsmode des Verbrauchers
$data{$type}{$name}{consumers}{$c}{icon} = $hc->{icon} // q{}; # Icon für den Verbraucher
$data{$type}{$name}{consumers}{$c}{oncom} = $hc->{on} // q{}; # Setter Einschaltkommando
$data{$type}{$name}{consumers}{$c}{offcom} = $hc->{off} // q{}; # Setter Ausschaltkommando
$data{$type}{$name}{consumers}{$c}{autoreading} = $rauto; # Readingname zur Automatiksteuerung
$data{$type}{$name}{consumers}{$c}{auto} = $auto; # Automaticsteuerung: 1 - Automatic ein, 0 - Automatic aus
$data{$type}{$name}{consumers}{$c}{retotal} = $rtot // q{}; # Reading der Leistungsmessung
$data{$type}{$name}{consumers}{$c}{uetotal} = $utot // q{}; # Unit der Leistungsmessung
$data{$type}{$name}{consumers}{$c}{rpcurr} = $rpcurr // q{}; # Reading der aktuellen Leistungsaufnahme
$data{$type}{$name}{consumers}{$c}{upcurr} = $upcurr // q{}; # Unit der aktuellen Leistungsaufnahme
$data{$type}{$name}{consumers}{$c}{notbefore} = $hc->{notbefore} // q{}; # nicht einschalten vor Stunde in 24h Format (00-23)
$data{$type}{$name}{consumers}{$c}{notafter} = $hc->{notafter} // q{}; # nicht einschalten nach Stunde in 24h Format (00-23)
$data{$type}{$name}{consumers}{$c}{name} = $consumer; # Name des Verbrauchers (Device)
$data{$type}{$name}{consumers}{$c}{alias} = $alias; # Alias des Verbrauchers (Device)
$data{$type}{$name}{consumers}{$c}{type} = $hc->{type} // $defctype; # Typ des Verbrauchers
$data{$type}{$name}{consumers}{$c}{power} = $hc->{power}; # Leistungsaufnahme des Verbrauchers in W
$data{$type}{$name}{consumers}{$c}{avgenergy} = $avgenergy; # Initialwert Energieverbrauch (evtl. Überschreiben in manageConsumerData)
$data{$type}{$name}{consumers}{$c}{mintime} = $hc->{mintime} // $hef{$ctype}{mt}; # Initialwert min. Einschalt- bzw. Zykluszeit (evtl. Überschreiben in manageConsumerData)
$data{$type}{$name}{consumers}{$c}{mode} = $hc->{mode} // $defcmode; # Planungsmode des Verbrauchers
$data{$type}{$name}{consumers}{$c}{icon} = $hc->{icon} // q{}; # Icon für den Verbraucher
$data{$type}{$name}{consumers}{$c}{oncom} = $hc->{on} // q{}; # Setter Einschaltkommando
$data{$type}{$name}{consumers}{$c}{offcom} = $hc->{off} // q{}; # Setter Ausschaltkommando
$data{$type}{$name}{consumers}{$c}{autoreading} = $rauto; # Readingname zur Automatiksteuerung
$data{$type}{$name}{consumers}{$c}{auto} = $auto; # Automaticsteuerung: 1 - Automatic ein, 0 - Automatic aus
$data{$type}{$name}{consumers}{$c}{retotal} = $rtot // q{}; # Reading der Leistungsmessung
$data{$type}{$name}{consumers}{$c}{uetotal} = $utot // q{}; # Unit der Leistungsmessung
$data{$type}{$name}{consumers}{$c}{powerthreshold} = $pthreshold // 0; # Schwellenwert (Wh pro Stunde) ab der ein Verbraucher als aktiv gewertet wird
$data{$type}{$name}{consumers}{$c}{rpcurr} = $rpcurr // q{}; # Reading der aktuellen Leistungsaufnahme
$data{$type}{$name}{consumers}{$c}{upcurr} = $upcurr // q{}; # Unit der aktuellen Leistungsaufnahme
$data{$type}{$name}{consumers}{$c}{notbefore} = $hc->{notbefore} // q{}; # nicht einschalten vor Stunde in 24h Format (00-23)
$data{$type}{$name}{consumers}{$c}{notafter} = $hc->{notafter} // q{}; # nicht einschalten nach Stunde in 24h Format (00-23)
}
Log3 ($name, 5, "$name - all registered consumers:\n".Dumper $data{$type}{$name}{consumers});
@ -6752,6 +6755,8 @@ return $def;
# retotal - Reading der Leistungsmessung
# uetotal - Unit der Leistungsmessung
# rpcurr - Readingname des aktuellen Verbrauchs
# powerthreshold - Schwellenwert (Wh pro Stunde) ab der ein
# Verbraucher als aktiv gewertet wird
# upcurr - Unit des aktuellen Verbrauchs
# avgenergy - gemessener Durchschnittsverbrauch eines Tages
# epieces - prognostizierte Energiescheiben (Hash)
@ -7494,7 +7499,7 @@ Ein/Ausschaltzeiten sowie deren Ausführung vom SolarForecast Modul übernehmen
<br>
<a id="SolarForecast-attr-consumer" data-pattern="consumer.*"></a>
<li><b>consumerXX &lt;Device Name&gt; type=&lt;type&gt; power=&lt;power&gt; [mode=&lt;mode&gt;] [icon=&lt;Icon&gt;] [mintime=&lt;minutes&gt;] [on=&lt;Kommando&gt;] [off=&lt;Kommando&gt;] [notbefore=&lt;Stunde&gt;] [notafter=&lt;Stunde&gt;] [auto=&lt;Readingname&gt;] [pcurr=&lt;Readingname&gt;:&lt;Einheit&gt;] [etotal=&lt;Readingname&gt;:&lt;Einheit&gt;] </b><br><br>
<li><b>consumerXX &lt;Device Name&gt; type=&lt;type&gt; power=&lt;power&gt; [mode=&lt;mode&gt;] [icon=&lt;Icon&gt;] [mintime=&lt;minutes&gt;] [on=&lt;Kommando&gt;] [off=&lt;Kommando&gt;] [notbefore=&lt;Stunde&gt;] [notafter=&lt;Stunde&gt;] [auto=&lt;Readingname&gt;] [pcurr=&lt;Readingname&gt;:&lt;Einheit&gt;] [etotal=&lt;Readingname&gt;:&lt;Einheit&gt;[:&lt;Schwellenwert&gt]] </b><br><br>
Registriert einen Verbraucher &lt;Device Name&gt; beim SolarForecast Device. Dabei ist &lt;Device Name&gt;
ein in FHEM bereits angelegtes Verbraucher Device, z.B. eine Schaltsteckdose. Die meisten Schlüssel sind optional,
@ -7525,14 +7530,15 @@ Ein/Ausschaltzeiten sowie deren Ausführung vom SolarForecast Modul übernehmen
<tr><td> <b>auto</b> </td><td>Reading im Verbraucherdevice welches das Schalten des Verbrauchers freigibt bzw. blockiert (optional) </td></tr>
<tr><td> </td><td>Readingwert = 1: Schalten freigegeben (default), 0: Schalten blockiert </td></tr>
<tr><td> <b>pcurr</b> </td><td>Reading welches den aktuellen Energieverbrauch (z.B. Schaltdose mit Energiemessung) liefert und Einheit (W/kW) (optional) </td></tr>
<tr><td> <b>etotal</b> </td><td>Reading welches die Summe der verbrauchten Energie liefert und Einheit (Wh/kWh) (optional) </td></tr>
<tr><td> <b>etotal</b> </td><td>Reading / Einheit (Wh/kWh), welches die Summe der verbrauchten Energie liefert (optional) </td></tr>
<tr><td> <b> </td><td>&lt;Schwellenwert&gt (Wh) = optionaler Energieverbrauch pro Stunde ab dem der Verbraucher als aktiv gewertet wird. </td></tr>
</table>
</ul>
<br>
<ul>
<b>Beispiele: </b> <br>
attr &lt;name&gt; consumer01 wallplug icon=scene_dishwasher@orange type=dishwasher mode=can power=2500 on=on off=off notafter=20 etotal=total:kWh <br>
attr &lt;name&gt; consumer01 wallplug icon=scene_dishwasher@orange type=dishwasher mode=can power=2500 on=on off=off notafter=20 etotal=total:kWh:5 <br>
attr &lt;name&gt; consumer02 WPxw type=heater mode=can power=3000 mintime=180 on="on-for-timer 3600" notafter=12
</ul>
</li>