10_EIB.pm: ABU 20160122 fixed doku, changed return value for EIB_Set from undef to "", reintegrated multiple group sending

git-svn-id: https://svn.fhem.de/fhem/trunk@10599 2b470e98-0d58-463d-a4d8-8e2adae1ed80
This commit is contained in:
andi291 2016-01-22 19:44:10 +00:00
parent 93d7ead5ce
commit 5ac737d0a4

View File

@ -20,6 +20,9 @@
# ABU 20151207 added dpt3, fixed doku-section myDimmer
# ABU 20151213 added dpt13
# ABU 20151221 added multiple group support for get according thread 45954
# ABU 20160111 added feature EIBreadingRegex, EIBwritingRegex, Fixed some doku
# ABU 20160116 fixed motd-error due to debug-mode
# ABU 20160122 fixed doku, changed return value for EIB_Set from undef to "", reintegrated multiple group sending
package main;
@ -144,6 +147,8 @@ EIB_Initialize($) {
"EIBreadingX:1,0 " .
"EIBreadingSender:1,0 " .
"EIBanswerReading:1,0 " .
"EIBreadingRegex " .
"EIBwritingRegex " .
"$readingFnAttributes " .
"model:".join(",", keys %eib_dpttypes);
}
@ -270,7 +275,8 @@ EIB_Get($@) {
sub
EIB_Set($@) {
my ($hash, @a, $str) = @_;
my $ret = undef;
#my $ret = undef;
my $ret = "";
my $na = int(@a);
#return, if no set value specified
@ -300,6 +306,19 @@ EIB_Set($@) {
my $groupnr = 1;
# the command can be send to any of the defined groups indexed starting by 1
# optional last argument starting with g indicates the group
# execute only for non-strings. Otherwise a "g" is interpreted to execute this group-send-mechanism...
if ($value ne "string")
{
$groupnr = $1 if($na>2 && $a[$na-1]=~ m/g([0-9]*)/);
#return, if unknown group
return "groupnr $groupnr not known." if(!$hash->{CODE}{$groupnr});
}
my $v = join(" ", @a);
Log3 $name, 5, "EIB set $v";
(undef, $v) = split(" ", $v, 2); # Not interested in the name...
# the command can be send to any of the defined groups indexed starting by 1
# optional last argument starting with g indicates the group
# execute only for non-strings. Otherwise a "g" is interpreted to execute this group-send-mechanism...
@ -420,10 +439,38 @@ EIB_Set($@) {
my $defptr = $modules{EIB}{defptr}{$code};
foreach my $n (keys %{ $defptr })
{
my $regAttr = $attr{$n}{"EIBwritingRegex"};
if ($regAttr)
{
#substitute contents of state, if desired
#
#get array of given attributes
my @reg = split("[ ]", $regAttr);
#format reading as input for regex
my $tempVal = "setG$groupnr:$v";
#loop over all regex
for (my $i = 0; $i < int(@reg); $i++)
{
#get search / replaye parts
my @regInner = split("\/", $reg[$i]);
$tempVal =~ s/$regInner[0]/$regInner[1]/g;
#log it
Log (5, "modified set with regex s/$regInner[0]/$regInner[1]/g to value $tempVal");
print ("modified set with regex s/$regInner[0]/$regInner[1]/g to value $tempVal\n") if ($debug eq 1);
}
#process result
readingsSingleUpdate($defptr->{$n},"state",$tempVal,1);
} else
{
#process regular reading
readingsSingleUpdate($defptr->{$n},"state",$v,1);
}
#debug
print "setg = $defptr->{$n}{NAME} , $groupnr , attr = AttrVal($defptr->{$n}{NAME},'EIBreadingX',0)n" if ($debug eq 1);
#process regular reading
readingsSingleUpdate($defptr->{$n}, "state", $v, 1);
#process extended reading - mark as set
readingsSingleUpdate($defptr->{$n},"setG" . $groupnr,$v,1) if (AttrVal($defptr->{$n}{NAME},'EIBreadingX',0) == 1);
}
@ -483,8 +530,36 @@ EIB_Parse($$) {
$lh->{RAWSTATE} = $rawv;
$lh->{LASTGROUP} = $dev;
my $regAttr = $attr{$n}{"EIBreadingRegex"};
if ($regAttr)
{
#substitute contents of state, if desired
#
#get array of given attributes
my @reg = split("[ ]", $regAttr);
#format reading as input for regex
my $tempVal = "getG$gnr:$v";
#loop over all regex
for (my $i = 0; $i < int(@reg); $i++)
{
#get search / replaye parts
my @regInner = split("\/", $reg[$i]);
$tempVal =~ s/$regInner[0]/$regInner[1]/g;
#log it
Log (5, "modified set with regex s/$regInner[0]/$regInner[1]/g to value $tempVal");
print ("modified set with regex s/$regInner[0]/$regInner[1]/g to value $tempVal\n") if ($debug eq 1);
}
#process result
readingsSingleUpdate($lh,"state",$tempVal,1);
}
else
{
#process regular reading
readingsSingleUpdate($lh,"state",$v,1);
}
#debug
print "getg = $n , group= $gnr , EIBreadingX = AttrVal($def->{$n}{NAME},'EIBreadingX',0)\n" if ($debug eq 1);
@ -1214,14 +1289,12 @@ eib_name2hex($)
<div style="margin-left: 2em">
<code>set &lt;name&gt; &lt;value&gt; [&lt;time&gt; g&lt;groupnr&gt;]</code>
<p>where value one of:</p>
<ul>
<li><b>on</b> switch on device</li>
<li><b>off</b> switch off device</li>
<li><b>on-for-timer</b> &lt;secs&gt; switch on the device for the given time. After the specified seconds a switch off command is sent.</li>
<li><b>on-till</b> &lt;time spec&gt; switches the device on. The device will be switched off at the given time.</li>
<li><b>raw</b> &lt;hexvalue&gt; sends the given value as raw data to the device.</li>
<li><b>value</b> &lt;decimal value&gt; transforms the value according to the chosen model and send the result to the device.</li>
</ul>
<p>Example:</p>
<pre>
set lamp1 on
@ -1249,12 +1322,12 @@ eib_name2hex($)
<p>The current date and time can be sent to the bus by the following settings:</p>
<pre>
define timedev EIB 0/0/7
attr timedev model dpt10
attr timedev model time
attr timedev eventMap /value now:now/
attr timedev webCmd now
define datedev EIB 0/0/8
attr datedev model dpt11
attr datedev model date
attr datedev eventMap /value now:now/
attr datedev webCmd now
@ -1269,91 +1342,40 @@ eib_name2hex($)
<p><a name="EIBget"></a> <b>Get</b></p>
<div style="margin-left: 2em">
<p>If you execute get for a EIB/KNX-Element there will be requested a state from the device. The device has to be able to respond to a read - this is not given for all devices.<br>
This function is not available for dummies.<br>
The answer from the bus-device is not shown in the toolbox, but is treated like a regular telegram.</p>
</div>
<p><a name="EIBattr"></a> <b>Attributes</b></p>
<div style="margin-left: 2em">
<ul>
<li><a href="#IODev">IODev</a></li>
<li><a href="#alias">alias</a></li>
<li><a href="#comment">comment</a></li>
<li><a href="#devStateIcon">devStateIcon</a></li>
<li><a href="#devStateStyle">devStateStyle</a></li>
<!-- <li><a href="#do_not_notify">do_not_notify</a></li> -->
<li><a href="#dummy">dummy</a></li>
<li><a href="#readingFnAttributes">readingFnAttributes</a></li>
<!-- <li><a href="#event-aggregator">event-aggregator</a></li>
<li><a href="#event-min-interval">event-min-interval</a></li>
<li><a href="#event-on-change-reading">event-on-change-reading</a></li>
<li><a href="#event-on-update-reading">event-on-update-reading</a></li>
-->
<li><a href="#eventMap">eventMap</a></li>
<li><a href="#group">group</a></li>
<li><a href="#icon">icon</a></li>
<li><a href="#ignore">ignore</a></li>
<!-- <li><a href="#loglevel">loglevel</a></li> -->
<li><a href="#room">room</a></li>
<li><a href="#showtime">showtime</a></li>
<li><a href="#sortby">sortby</a></li>
<!-- <li><a href="#stateFormat">stateFormat</a></li>
<li><a href="#userReadings">userReadings</a></li>
-->
<li><a href="#userattr">userattr</a></li>
<li><a href="#verbose">verbose</a></li>
<li><a href="#webCmd">webCmd</a></li>
<li><a href="#widgetOverride">widgetOverride</a></li>
<li><b>model</b> -
set the model according to the datapoint types defined by the (<a href="http://www.sti.uniurb.it/romanell/110504-Lez10a-KNX-Datapoint%20Types%20v1.5.00%20AS.pdf" target="_blank">EIB / KNX specifications</a>). The device state in FHEM is interpreted and shown according to the specification.
<ul>
<li>dpt1 -> will be interpreted as on/off</li>
<li>dpt5</li>
<li>dpt5.003</li>
<li>angle</li>
<li>percent</li>
<li>dpt3 -> usage: set value to +/-0..100. -54 means dim down by 50%</li>
<li>dpt5.004</li>
<li>percent255</li>
<li>dpt6</li>
<li>dpt6.001</li>
<li>dpt6.010</li>
<li>dpt7</li>
<li>length-mm</li>
<li>current-mA</li>
<li>brightness</li>
<li>timeperiod-ms</li>
<li>timeperiod-min</li>
<li>timeperiod-h</li>
<li>dpt9</li>
<li>tempsensor</li>
<li>lightsensor</li>
<li>speedsensor</li>
<li>speedsensor-km/h</li>
<li>pressuresensor</li>
<li>rainsensor</li>
<li>time1sensor</li>
<li>time2sensor</li>
<li>humiditysensor</li>
<li>airqualitysensor</li>
<li>voltage-mV</li>
<li>current-mA2</li>
<li>current-mA2</li>
<li>power</li>
<li>powerdensity</li>
<li>dpt10 -> transferred from and to state, format hh:mm:ss</li>
<li>dpt10_ns -> same as DPT10, seconds always 0</li>
<li>time -> receiving has no effect, sending any value contains actual system time</li>
<li>dpt11 -> transferred from and to state, format hh:mm:ss</li>
<li>date -> receiving has no effect, sending any value contains actual system date</li>
<li>dpt12</li>
<li>dpt13</li>
<li>dpt14</li>
<li>dpt16 -> has to be used with "set string"</li>
</ul>
</li>
<div style="margin-left: 2em"><br>
<a href="#IODev">IODev</a><br>
<a href="#alias">alias</a><br>
<a href="#comment">comment</a><br>
<a href="#devStateIcon">devStateIcon</a><br>
<a href="#devStateStyle">devStateStyle</a><br>
<a href="#do_not_notify">do_not_notify</a><br>
<a href="#dummy">dummy</a><br>
<a href="#readingFnAttributes">readingFnAttributes</a><br>
<a href="#event-aggregator">event-aggregator</a><br>
<a href="#event-min-interval">event-min-interval</a><br>
<a href="#event-on-change-reading">event-on-change-reading</a><br>
<a href="#event-on-update-reading">event-on-update-reading</a><br>
<a href="#eventMap">eventMap</a><br>
<a href="#group">group</a><br>
<a href="#icon">icon</a><br>
<a href="#ignore">ignore</a><br>
<a href="#room">room</a><br>
<a href="#showtime">showtime</a><br>
<a href="#sortby">sortby</a><br>
<a href="#stateFormat">stateFormat</a><br>
<a href="#userReadings">userReadings</a><br>
<a href="#userattr">userattr</a><br>
<a href="#verbose">verbose</a><br>
<a href="#webCmd">webCmd</a><br>
<a href="#widgetOverride">widgetOverride</a><br>
<br>
<li><b>EIBreadingX</b> -
<p><a name="EIBreadingX"></a> <b>EIBreadingX</b></p>
<div style="margin-left: 2em">
Enable additional readings for this EIB-device. With this Attribute set, a reading setG&lt;x&gt; will be updated when a set command is issued from FHEM, a reading getG&lt;x&gt; will be updated as soon a Value is received from EIB-Bus (&lt;x&gt; stands for the groupnr. - see define statement). The logic for the state reading remains unchanged. This is especially useful when the define statement contains more than one group parameter.
<p>If set to 1, the following additional readings will be available:</p>
<pre>
@ -1364,43 +1386,124 @@ eib_name2hex($)
<pre>
define myDimmer EIB 0/1/1 0/1/2
attr myDimmer EIBreadingX 1
attr myDimmer model dpt1 dpt5.Slider # GA 0/1/1 will be interpreted as on/off, GA 0/1/2 will be handled as dpt5 and show a slider on FHEMWEB
attr myDimmer eventMap /on:An/off:Aus/value g2:dim/
attr myDimmer webCmd on:off:dim
attr myDimmer stateFormat getG2 % # copies actual dim-level (as sent/received to/from dimmer) into STATE
attr myDimmer model dpt1 dpt5 # GA 0/1/1 will be interpreted as on/off, GA 0/1/2 will be handled as dpt5
attr myDimmer stateFormat getG2 % # copies actual dim-level (as received from dimmer) into STATE
</pre>
</li>
<p>If the EIBreadingX is set, you can specify multiple blank separated models to cope with multiple groups in the define statement. The setting cannot be done thru the pulldown-menu, you have to specify them with <code>attr &lt;device&gt; model &lt;dpt1&gt; &lt;dpt2&gt; &lt;dpt3&gt;</code></p>
</div>
<li><b>EIBreadingSender</b> -
<p><a name="EIBreadingSender"></a> <b>EIBreadingSender</b></p>
<div style="margin-left: 2em">
Enable an additional reading for this EIB-device. With this Attribute set, a reading sender will be updated any time a new telegram arrives.
<p>If set to 1, the following additional reading will be available:</p>
<p>If set to 1, the following additional reading will be available: <pre>sender</pre></p>
<pre>
sender will be updated any time a new telegram arrives at this group-adress
</pre>
<p>Example:</p>
<pre>
define myDimmer EIB 0/1/1 0/1/2
define myDimmer EIB 0/1/1
attr myDimmer EIBreadingSender 1
</pre>
</li>
</div>
<li><b>EIBreadOnStart</b> -
<p><a name="EIBanswerReading"></a> <b>EIBanswerReading</b></p>
<div style="margin-left: 2em">
If enabled, FHEM answers on read requests. The content of state is send to the bus as answer.
<p>If set to 1, read-requests are answered</p>
<pre>
FHEM will respond
</pre>
<p>Example:</p>
<pre>
define myDimmer EIB 0/1/1 0/1/2
attr myDimmer EIBanswerReading 1
define myValue EIB 0/1/1
attr myValue EIBanswerReading 1
</pre>
</li>
</div>
</ul>
<p><a name="EIBreadingRegex"></a> <b>EIBreadingRegex</b></p>
<div style="margin-left: 2em">
You can pass n pairs of regex-pattern and string to replace, seperated by a slash. Internally the "new" state is always in the format getG[n]:[state]. The substitution is done every time, a new object is received. You can use this function for converting, adding units, having more fun with icons, ...
This function has only an impact on the content of state - no other functions are disturbed.
<p>Example:</p>
<pre>
define myLamp EIB 0/1/1 0/1/2 0/1/2
attr myLamp EIBreadingRegex getG[1]:/steuern: getG[2]:/status: getG[3]:/sperre:
attr myLamp EIBreadingRegex devStateIcon status.on:general_an status.off:general_aus sperre.on:lock
</pre>
</div>
<p><a name="EIBwritingRegex"></a> <b>EIBwritingRegex</b></p>
<div style="margin-left: 2em">
You can pass n pairs of regex-pattern and string to replace, seperated by a slash. Internally the "new" state is always in the format setG1:[state]. The substitution is done every time, after an object is send. You can use this function for converting, adding units, having more fun with icons, ...
This function has only an impact on the content of state - no other functions are disturbed.
<p>Example:</p>
<pre>
define myLockObject EIB 0/1/1
attr myLamp EIBwritingRegex setG1:on/LOCKED setG1:/UNLOCKED
</pre>
</div>
<p><a name="model"></a> <b>model</b></p>
<div style="margin-left: 2em">
<p>This attribute is mandatory!</p>
Set the model according to the datapoint types defined by the (<a href="http://www.sti.uniurb.it/romanell/110504-Lez10a-KNX-Datapoint%20Types%20v1.5.00%20AS.pdf" target="_blank">EIB / KNX specifications</a>). The device state in FHEM is interpreted and shown according to the specification.<br>
<br>
<U>dpt1</U> - 1 bit<br>
Will be interpreted as on/off, 1=on 0=off and vice versa<br>
<br>
<U>dpt3</U> - Discrete Dim-Message<br>
Usage: set value to +/-0..100. -54 means dim down by 50%<br>
<br>
<U>dpt5</U> - 1 byte unsigned<br>
dpt5.003 - angle in degrees<br>
angle - same as dpt5.003<br>
dpt5.004 - percent<br>
percent - same as above<br>
percent255 - scaled percentage: 255=100%<br>
<br>
<U>dpt6</U> - 1 byte signed <br>
dpt6.001 - percent<br>
dpt6.010<br>
<br>
<U>dpt7</U> - 2 byte unsigned<br>
length - mm<br>
current - mA<br>
brightness<br>
timeperiod - ms<br>
timeperiod - min<br>
timeperiod - h<br>
<br>
<U>dpt9</U> - 2 byte float<br>
tempsensor<br>
lightsensor<br>
speedsensor<br>
speedsensor-km/h<br>
pressuresensor<br>
rainsensor<br>
time1sensor<br>
time2sensor<br>
humiditysensor<br>
airqualitysensor<br>
voltage-mV<br>
current-mA2<br>
current-mA2<br>
power<br>
powerdensity<br>
<br>
<U>dpt10</U> - time hh:mm:ss<br>
dpt10_ns - same as DPT10, seconds always 0<br>
time - receiving has no effect, sending any value contains actual system time. For examle use set timedev value now<br>
<br>
<U>dpt11</U> - date dd.mm.yyyy<br>
date - receiving has no effect, sending any value contains actual system date. For examle use set timedev value now<br>
<br>
<U>dpt12</U> - 4 byte unsigned<br>
<br>
<U>dpt13</U> - 4 byte signed<br>
<br>
<U>dpt14</U> - 4 byte float<br>
<br>
<U>dpt16</U> - text, use with "string": set textdev string Hallo Welt<br>
</div>
</div>
=end html
=cut