2
0
mirror of https://github.com/fhem/fhem-mirror.git synced 2025-03-10 09:16:53 +00:00

cb power infos

git-svn-id: https://svn.fhem.de/fhem/trunk@6381 2b470e98-0d58-463d-a4d8-8e2adae1ed80
This commit is contained in:
hexenmeister 2014-08-08 21:57:26 +00:00
parent 92624bcd5f
commit 4b2b488a2e

View File

@ -30,7 +30,7 @@ package main;
use strict;
use warnings;
my $VERSION = "1.6.0";
my $VERSION = "1.6.1";
use constant {
DATE => "date",
@ -2018,7 +2018,7 @@ sub SYSMON_PowerAcInfo($$)
#$map->{"power_".$type."_current"}=$d_current;
#$map->{"power_".$type."_voltage"}=$d_voltage;
$map->{"power_".$type."_stat"}="$d_online $d_present $d_voltage $d_current";
$map->{"power_".$type."_text"}=$type.": ".(($d_present eq "1") ? "present" : "absent")." / ".($d_online eq "1" ? "online" : "offline").", Voltage: ".$d_voltage." V, Current: ".$d_current." mA";
$map->{"power_".$type."_text"}=$type.": ".(($d_present eq "1") ? "present" : "absent")." / ".($d_online eq "1" ? "online" : "offline").", voltage: ".$d_voltage." V, current: ".$d_current." mA";
return $map;
}
@ -2042,7 +2042,7 @@ sub SYSMON_PowerUsbInfo($$)
#$map->{"power_".$type."_current"}=$d_current;
#$map->{"power_".$type."_voltage"}=$d_voltage;
$map->{"power_".$type."_stat"}="$d_online $d_present $d_voltage $d_current";
$map->{"power_".$type."_text"}=$type.": ".(($d_present eq "1") ? "present" : "absent")." / ".($d_online eq "1" ? "online" : "offline").", Voltage: ".$d_voltage." V, Current: ".$d_current." mA";
$map->{"power_".$type."_text"}=$type.": ".(($d_present eq "1") ? "present" : "absent")." / ".($d_online eq "1" ? "online" : "offline").", voltage: ".$d_voltage." V, current: ".$d_current." mA";
return $map;
}
@ -2061,18 +2061,20 @@ sub SYSMON_PowerBatInfo($$)
my $d_voltage = SYSMON_execute($hash, $base."voltage_now");
if(defined $d_voltage) {$d_voltage/=1000000;}
my $d_capacity = trim(SYSMON_execute($hash, $base."capacity"));
if($d_present ne "1") {
$d_capacity = "0";
}
#$map->{"power_".$type."_online"}=$d_online;
#$map->{"power_".$type."_present"}=$d_present;
#$map->{"power_".$type."_current"}=$d_current;
#$map->{"power_".$type."_voltage"}=$d_voltage;
$map->{"power_".$type."_stat"}="$d_online $d_present $d_voltage $d_current";
$map->{"power_".$type."_text"}=$type.": ".(($d_present eq "1") ? "present" : "absent")." / ".($d_online eq "1" ? "online" : "offline").", Voltage: ".$d_voltage." V, Current: ".$d_current." mA";
$map->{"power_".$type."_stat"}="$d_online $d_present $d_voltage $d_current $d_capacity";
$map->{"power_".$type."_text"}=$type.": ".(($d_present eq "1") ? "present" : "absent")." / ".($d_online eq "1" ? "online" : "offline").", voltage: ".$d_voltage." V, current: ".$d_current." mA, capacity: ".$d_capacity." %";
# TODO
if($d_present eq "1") {
# Zusaetzlich: technology, capacity, status, health, temp (/10 => °C)
my $d_technology = trim(SYSMON_execute($hash, $base."technology"));
my $d_capacity = trim(SYSMON_execute($hash, $base."capacity"));
my $d_status = trim(SYSMON_execute($hash, $base."status"));
my $d_health = trim(SYSMON_execute($hash, $base."health"));
my $d_energy_full_design = trim(SYSMON_execute($hash, $base."energy_full_design"));
@ -2291,7 +2293,7 @@ If one (or more) of the multiplier is set to zero, the corresponding readings is
<br>
<b>Power Supply Readings</b>
<li>power_ac_stat<br>
status information to the AC socket: present (0|1), online (0|1), voltage, current
status information to the AC socket: present (0|1), online (0|1), voltage, current<br>
Example:<br>
<code>power_ac_stat: 1 1 4.807 264</code><br>
</li>
@ -2299,7 +2301,7 @@ If one (or more) of the multiplier is set to zero, the corresponding readings is
<li>power_ac_text<br>
human readable status information to the AC socket<br>
Example:<br>
<code>power_ac_text ac: present / online, Voltage: 4.807 V, Current: 264 mA</code><br>
<code>power_ac_text ac: present / online, voltage: 4.807 V, current: 264 mA</code><br>
</li>
<br>
<li>power_usb_stat<br>
@ -2311,7 +2313,9 @@ If one (or more) of the multiplier is set to zero, the corresponding readings is
</li>
<br>
<li>power_battery_stat<br>
status information to the battery (if installed)
status information to the battery (if installed): present (0|1), online (0|1), voltage, current, actual capacity<br>
Example:<br>
<code>power_battery_stat: 1 1 4.807 264 100</code><br>
</li>
<br>
<li>power_battery_text<br>
@ -2514,6 +2518,9 @@ If one (or more) of the multiplier is set to zero, the corresponding readings is
SM_CPUStat.gplot<br>
SM_CPUStatSum.gplot<br>
SM_CPUStatTotal.gplot<br>
SM_power_ac.gplot<br>
SM_power_usb.gplot<br>
SM_power_battery.gplot<br>
</code>
DbLog versions:<br>
<code>
@ -2630,6 +2637,17 @@ If one (or more) of the multiplier is set to zero, the corresponding readings is
attr wl_sysmon_cpustatT group RPi<br>
attr wl_sysmon_cpustatT plotsize 840,420<br>
attr wl_sysmon_cpustatT room 9.99_Test<br>
<br>
# Anzeige Stromversorgung AC
define wl_sysmon_power_ac SVG FileLog_sysmon:SM_power_ac:CURRENT
attr wl_sysmon_power_ac label "Stromversorgung (ac) Spannung: $data{min1} - $data{max1} V, Strom: $data{min2} - $data{max2} mA"
attr wl_sysmon_power_ac room Technik
attr wl_sysmon_power_ac group system
# Anzeige Stromversorgung Battery
define wl_sysmon_power_bat SVG FileLog_sysmon:SM_power_battery:CURRENT
attr wl_sysmon_power_bat label "Stromversorgung (bat) Spannung: $data{min1} - $data{max1} V, Strom: $data{min2} - $data{max2} mA"
attr wl_sysmon_power_bat room Technik
attr wl_sysmon_power_bat group system
</code>
</ul>
@ -2801,7 +2819,7 @@ If one (or more) of the multiplier is set to zero, the corresponding readings is
<br>
<b>Readings zur Stromversorgung</b>
<li>power_ac_stat<br>
Statusinformation f&uuml;r die AC-Buchse: present (0|1), online (0|1), voltage, current
Statusinformation f&uuml;r die AC-Buchse: present (0|1), online (0|1), voltage, current<br>
Beispiel:<br>
<code>power_ac_stat: 1 1 4.807 264</code><br>
</li>
@ -2821,7 +2839,9 @@ If one (or more) of the multiplier is set to zero, the corresponding readings is
</li>
<br>
<li>power_battery_stat<br>
Statusinformation f&uuml;r die Batterie (wenn vorhanden)
Statusinformation f&uuml;r die Batterie (wenn vorhanden): present (0|1), online (0|1), voltage, current, actual capacity<br>
Beispiel:<br>
<code>power_battery_stat: 1 1 4.807 264 100</code><br>
</li>
<br>
<li>power_battery_text<br>
@ -3033,6 +3053,9 @@ If one (or more) of the multiplier is set to zero, the corresponding readings is
SM_CPUStat.gplot<br>
SM_CPUStatSum.gplot<br>
SM_CPUStatTotal.gplot<br>
SM_power_ac.gplot<br>
SM_power_usb.gplot<br>
SM_power_battery.gplot<br>
</code>
DbLog-Versionen:<br>
<code>
@ -3152,6 +3175,17 @@ If one (or more) of the multiplier is set to zero, the corresponding readings is
attr wl_sysmon_cpustatT group RPi<br>
attr wl_sysmon_cpustatT plotsize 840,420<br>
attr wl_sysmon_cpustatT room 9.99_Test<br>
<br>
# Anzeige Stromversorgung AC
define wl_sysmon_power_ac SVG FileLog_sysmon:SM_power_ac:CURRENT
attr wl_sysmon_power_ac label "Stromversorgung (ac) Spannung: $data{min1} - $data{max1} V, Strom: $data{min2} - $data{max2} mA"
attr wl_sysmon_power_ac room Technik
attr wl_sysmon_power_ac group system
# Anzeige Stromversorgung Battery
define wl_sysmon_power_bat SVG FileLog_sysmon:SM_power_battery:CURRENT
attr wl_sysmon_power_bat label "Stromversorgung (bat) Spannung: $data{min1} - $data{max1} V, Strom: $data{min2} - $data{max2} mA"
attr wl_sysmon_power_bat room Technik
attr wl_sysmon_power_bat group system
</code>