76_SolarForecast: contrib 1.6.0
git-svn-id: https://svn.fhem.de/fhem/trunk@28287 2b470e98-0d58-463d-a4d8-8e2adae1ed80
This commit is contained in:
parent
b456c75f59
commit
48b3826e18
@ -155,7 +155,7 @@ BEGIN {
|
||||
my %vNotesIntern = (
|
||||
"1.6.0" => "12.12.2023 store daily batmaxsoc in pvHistory, new attr ctrlBatSocManagement, reading Battery_OptimumTargetSoC ".
|
||||
"currentBatteryDev: new optional key 'cap', adapt cloud2bin,temp2bin,rain2bin ".
|
||||
"minor internal changes, isAddSwitchOffCond: change hysteresis algo, ctrlDebug: new entry batterieManagement ",
|
||||
"minor internal changes, isAddSwitchOffCond: change hysteresis algo, ctrlDebug: new entry batteryManagement ",
|
||||
"1.5.1" => "07.12.2023 function _getftui can now process arguments (compatibility to new ftui widgets), plant check ".
|
||||
"reviews SolarForecast widget files ",
|
||||
"1.5.0" => "05.12.2023 new getter ftuiFramefiles ",
|
||||
@ -552,7 +552,7 @@ my @dd = qw( none
|
||||
aiData
|
||||
apiCall
|
||||
apiProcess
|
||||
batterieManagement
|
||||
batteryManagement
|
||||
collectData
|
||||
consumerPlanning
|
||||
consumerSwitching
|
||||
@ -6447,7 +6447,7 @@ sub _batSocTarget {
|
||||
$batymaxsoc >= $maxsoc ? $batysetsoc - $batSocChgDay :
|
||||
$batysetsoc; # neuer Min SOC für den laufenden Tag
|
||||
|
||||
debugLog ($paref, 'batterieManagement', "SoC calc Step1 - compare with SoC history -> Target: $target %");
|
||||
debugLog ($paref, 'batteryManagement', "SoC calc Step1 - compare with SoC history -> Target: $target %");
|
||||
|
||||
## Aufladewahrscheinlichkeit beachten
|
||||
#######################################
|
||||
@ -6462,7 +6462,7 @@ sub _batSocTarget {
|
||||
|
||||
$target = $cantarget < $target ? $cantarget : $target; # Abgleich möglicher Min SOC gg. berechneten Min SOC
|
||||
|
||||
debugLog ($paref, 'batterieManagement', "SoC calc Step2 - note charging probability -> Target: $target %");
|
||||
debugLog ($paref, 'batteryManagement', "SoC calc Step2 - note charging probability -> Target: $target %");
|
||||
|
||||
## low/up-Grenzen beachten
|
||||
############################
|
||||
@ -6470,7 +6470,7 @@ sub _batSocTarget {
|
||||
$target < $lowSoc ? $lowSoc :
|
||||
$target;
|
||||
|
||||
debugLog ($paref, 'batterieManagement', "SoC calc Step3 - observe low/up limits -> Target: $target %");
|
||||
debugLog ($paref, 'batteryManagement', "SoC calc Step3 - observe low/up limits -> Target: $target %");
|
||||
|
||||
## Pflege-SoC (Soll SoC $maxSoCdef bei $batSocChgDay % Steigerung p. Tag)
|
||||
###########################################################################
|
||||
@ -6485,7 +6485,7 @@ sub _batSocTarget {
|
||||
$target = $careSoc < $target ? $target : $careSoc; # resultierender Target-SoC unter Berücksichtigung $caresoc
|
||||
$target = sprintf "%.0f", $target;
|
||||
|
||||
debugLog ($paref, 'batterieManagement', "SoC calc Step4 - note remaining days until care SoC -> Target: $target %");
|
||||
debugLog ($paref, 'batteryManagement', "SoC calc Step4 - note remaining days until care SoC -> Target: $target %");
|
||||
|
||||
## pvHistory/Readings schreiben
|
||||
#################################
|
||||
@ -13323,7 +13323,9 @@ sub checkPlantConfig {
|
||||
$result->{'FTUI Widget Files'}{state} = $warn;
|
||||
$result->{'FTUI Widget Files'}{result} .= $hqtxt{widerr}{$lang}.'<br>';
|
||||
$result->{'FTUI Widget Files'}{result} .= $cmmsg.'<br>';
|
||||
$result->{'FTUI Widget Files'}{note} .= qq{Try the test again later. If the error is permanent, please inform the maintainer.<br>};
|
||||
$result->{'FTUI Widget Files'}{note} .= qq{Update the FHEM Tablet UI Widget Files with the command: <br>};
|
||||
$result->{'FTUI Widget Files'}{note} .= qq{"get $name ftuiFramefiles". <br>};
|
||||
$result->{'FTUI Widget Files'}{note} .= qq{After that do the test again. If the error is permanent, please inform the maintainer.<br>};
|
||||
$result->{'FTUI Widget Files'}{warn} = 1;
|
||||
|
||||
$upd = 0;
|
||||
@ -16528,7 +16530,7 @@ to ensure that the system configuration is correct.
|
||||
<tr><td> <b>aiData</b> </td><td>AI data </td></tr>
|
||||
<tr><td> <b>apiCall</b> </td><td>Retrieval API interface without data output </td></tr>
|
||||
<tr><td> <b>apiProcess</b> </td><td>API data retrieval and processing </td></tr>
|
||||
<tr><td> <b>batterieManagement</b> </td><td>Battery management control values (SoC) </td></tr>
|
||||
<tr><td> <b>batteryManagement</b> </td><td>Battery management control values (SoC) </td></tr>
|
||||
<tr><td> <b>collectData</b> </td><td>detailed data collection </td></tr>
|
||||
<tr><td> <b>consumerPlanning</b> </td><td>Consumer scheduling processes </td></tr>
|
||||
<tr><td> <b>consumerSwitching</b> </td><td>Operations of the internal consumer switching module </td></tr>
|
||||
@ -18557,7 +18559,7 @@ die ordnungsgemäße Anlagenkonfiguration geprüft werden.
|
||||
<tr><td> <b>aiData</b> </td><td>KI Daten </td></tr>
|
||||
<tr><td> <b>apiCall</b> </td><td>Abruf API Schnittstelle ohne Datenausgabe </td></tr>
|
||||
<tr><td> <b>apiProcess</b> </td><td>Abruf und Verarbeitung von API Daten </td></tr>
|
||||
<tr><td> <b>batterieManagement</b> </td><td>Steuerungswerte des Batterie Managements (SoC) </td></tr>
|
||||
<tr><td> <b>batteryManagement</b> </td><td>Steuerungswerte des Batterie Managements (SoC) </td></tr>
|
||||
<tr><td> <b>collectData</b> </td><td>detailliierte Datensammlung </td></tr>
|
||||
<tr><td> <b>consumerPlanning</b> </td><td>Consumer Einplanungsprozesse </td></tr>
|
||||
<tr><td> <b>consumerSwitching</b> </td><td>Operationen des internen Consumer Schaltmodul </td></tr>
|
||||
|