94_PWM.pm : support of maxOffTime to prevent floor from cooling out

git-svn-id: https://svn.fhem.de/fhem/trunk@18631 2b470e98-0d58-463d-a4d8-8e2adae1ed80
This commit is contained in:
jamesgo 2019-02-18 13:14:35 +00:00
parent d55b2e623a
commit 4890a724fb

View File

@ -32,6 +32,7 @@
# 13.12.17 GA fix consider $roomsWaitOffset{$wkey} in oldpulse set for each room
# 31.01.18 GA add support for stateFormat
# 05.02.18 GA fix typo overallHeatingSwitchThresholdTemup
# 19.11.18 GA add support for attribute maxOffTime
##############################################
# $Id$
@ -99,19 +100,22 @@ PWM_Calculate($)
my ($hash) = @_;
my $name = $hash->{NAME};
my %RoomsToSwitchOn = ();
my %RoomsToSwitchOff = ();
my %RoomsToStayOn = ();
my %RoomsToStayOff = ();
my %RoomsValveProtect = ();
my %RoomsPulses = ();
my $roomsActive = 0;
my $newpulseMax = 0;
my $newpulseSum = 0;
my $newpulseAvg = 0;
my $newpulseAvg2 = 0;
my $newpulseAvg3 = 0;
my $wkey = "";
my %RoomsToSwitchOn = ();
my %RoomsToSwitchOff = ();
my %RoomsToStayOn = ();
my %RoomsToStayOff = ();
my %RoomsValveProtect = ();
my %RoomsMaxOffTimeProtect = ();
my %RoomsPulses = ();
my $roomsActive = 0;
my $newpulseMax = 0;
my $newpulseSum = 0;
my $newpulseAvg = 0;
my $newpulseAvg2 = 0;
my $newpulseAvg3 = 0;
my $RoomsMaxOffTimeProtect_on = 0;
my $wkey = "";
if($hash->{INTERVAL} > 0) {
InternalTimer(gettimeofday() + $hash->{INTERVAL}, "PWM_Calculate", $hash, 0);
@ -132,7 +136,6 @@ PWM_Calculate($)
readingsBeginUpdate ($hash);
readingsBulkUpdate ($hash, "lastrun", "calculating");
#$hash->{STATE} = "lastrun: ".$hash->{READINGS}{lastrun}{TIME};
readingsBulkUpdate ($hash, "state", "lastrun: ".$hash->{READINGS}{lastrun}{TIME});
# loop over all devices
@ -146,12 +149,15 @@ PWM_Calculate($)
if ($hash->{NAME} eq $defs{$d}{IODev}->{NAME}) { # referencing to this fb
Log3 ($hash, 4, "PWM_Calculate calc $name, room $d");
$roomsActive++;
########################
# calculate room
# $newstate is "" if state is unchanged
# $newstate is "on" or "off" if state changes
# $newstate may be "on_vp" or "off_vp" if valve protection is active
# $newstate may be "off_mop" if maxOffTime protection has ended
# $newstate may be "on_mop" or "on_mop_stay" or "on_mop_maybe" if maxOffTime protection is active stays active or may become active
my ($newstate, $newpulse, $cycletime, $oldstate) = PWM_CalcRoom($hash, $defs{$d});
my $onoff = $newpulse * $cycletime;
@ -159,67 +165,93 @@ PWM_Calculate($)
$onoff = (1 - $newpulse) * $cycletime
}
##############################
##### Valve Protect
if ($newstate eq "on_vp") {
$RoomsValveProtect{$d} = "on";
} elsif ($newstate eq "off_vp") {
$RoomsValveProtect{$d} = "off";
}
$wkey = $name."_".$d;
if (defined ($roomsWaitOffset{$wkey})) {
$hash->{helper}{pulses}{$d} = $newpulse." / ".$roomsWaitOffset{$wkey};
$newpulse += $roomsWaitOffset{$wkey};
} else {
$roomsWaitOffset{$wkey} = 0;
$hash->{helper}{pulses}{$d} = $newpulse." / ".$roomsWaitOffset{$wkey};
}
$defs{$d}->{READINGS}{oldpulse}{TIME} = TimeNow();
$defs{$d}->{READINGS}{oldpulse}{VAL} = $newpulse;
##############################
##### maxOffTimeProtect
$roomsActive++;
$RoomsPulses{$d} = $newpulse;
$newpulseSum += $newpulse;
$newpulseMax = max($newpulseMax, $newpulse);
# $newstate ne "" -> state changed "on" -> "off" or "off" -> "on"
if ((int($hash->{MINONOFFTIME}) > 0) &&
(($newstate eq "on") or ($newstate eq "off")) &&
($onoff < int($hash->{MINONOFFTIME}))
) {
#######################
# actor devices take 3 minutes for an open/close cycle
# this is handled by MINONOFFTIME
Log3 ($hash, 3, "PWM_Calculate $d: F0 stay unchanged $oldstate: ".
"($onoff < $hash->{MINONOFFTIME} sec)");
if ($oldstate eq "off") {
$RoomsToStayOff{$d} = $newpulse;
} else {
$RoomsToStayOn{$d} = $newpulse;
}
} else {
# state changed and it is worth to move the device
if ($newstate eq "on") {
$RoomsToSwitchOn{$d} = $newpulse;
} elsif ($newstate eq "off") {
$RoomsToSwitchOff{$d} = $newpulse;
} elsif ($newstate eq "") {
if ($oldstate eq "on") {
$RoomsToStayOn{$d} = $newpulse;
} else {
$RoomsToStayOff{$d} = $newpulse;
}
if ($newstate eq "on_mop") {
$RoomsMaxOffTimeProtect_on++;
$RoomsMaxOffTimeProtect{$d} = $newstate;
$newstate = "on";
} elsif ($newstate eq "on_mop_stay") {
$RoomsMaxOffTimeProtect_on++;
$RoomsMaxOffTimeProtect{$d} = $newstate;
$newstate = "";
} elsif ($newstate eq "on_mop_maybe") {
$RoomsMaxOffTimeProtect{$d} = $newstate;
$newstate = "";
} elsif ($newstate eq "off_mop") {
$RoomsMaxOffTimeProtect{$d} = $newstate;
$newstate = "off";
}
##############################
##### regular calculation
$wkey = $name."_".$d;
if (defined ($roomsWaitOffset{$wkey})) {
$hash->{helper}{pulses}{$d} = $newpulse." / ".$roomsWaitOffset{$wkey};
$newpulse += $roomsWaitOffset{$wkey};
} else {
$roomsWaitOffset{$wkey} = 0;
$hash->{helper}{pulses}{$d} = $newpulse." / ".$roomsWaitOffset{$wkey};
}
$defs{$d}->{READINGS}{oldpulse}{TIME} = TimeNow();
$defs{$d}->{READINGS}{oldpulse}{VAL} = $newpulse;
$RoomsPulses{$d} = $newpulse;
$newpulseSum += $newpulse;
$newpulseMax = max($newpulseMax, $newpulse);
# $newstate ne "" -> state changed "on" -> "off" or "off" -> "on"
if ((int($hash->{MINONOFFTIME}) > 0) &&
(($newstate eq "on") or ($newstate eq "off")) &&
($onoff < int($hash->{MINONOFFTIME}))
) {
#######################
# actor devices take 3 minutes for an open/close cycle
# this is handled by MINONOFFTIME
Log3 ($hash, 3, "PWM_Calculate $d: F0 stay unchanged $oldstate: ".
"($onoff < $hash->{MINONOFFTIME} sec)");
if ($oldstate eq "off") {
$RoomsToStayOff{$d} = 1;
} else {
$RoomsToStayOn{$d} = 1;
}
} else {
# state changed and it is worth to move the device
if ($newstate eq "on") {
$RoomsToSwitchOn{$d} = 1;
} elsif ($newstate eq "off") {
$RoomsToSwitchOff{$d} = 1;
} elsif ($newstate eq "") {
if ($oldstate eq "on") {
$RoomsToStayOn{$d} = 1;
} else {
$RoomsToStayOff{$d} = 1;
}
}
}
}
}
@ -228,6 +260,41 @@ PWM_Calculate($)
}
# maxOffTimeProtect handling
foreach my $d (keys %RoomsMaxOffTimeProtect) {
if ($RoomsMaxOffTimeProtect{$d} eq "off_mop") {
$RoomsToSwitchOff{$d} = 1;
$RoomsPulses{$d} = 0;
} elsif ($RoomsMaxOffTimeProtect{$d} eq "on_mop") {
$RoomsToSwitchOn{$d} = 1;
$RoomsPulses{$d} = $hash->{MaxPulse};
} elsif ($RoomsMaxOffTimeProtect{$d} eq "on_mop_stay") {
$RoomsToStayOn{$d} = 1;
$RoomsPulses{$d} = $hash->{MaxPulse};
} elsif ($RoomsMaxOffTimeProtect{$d} eq "on_mop_maybe") {
if ($RoomsMaxOffTimeProtect_on > 0) {
$RoomsToSwitchOn{$d} = 1;
$RoomsPulses{$d} = $hash->{MaxPulse};
} else {
$RoomsToStayOff{$d} = 1;
$RoomsPulses{$d} = 0;
}
}
$defs{$d}->{READINGS}{oldpulse}{TIME} = TimeNow();
$defs{$d}->{READINGS}{oldpulse}{VAL} = $RoomsPulses{$d};
$newpulseSum += $RoomsPulses{$d};
$newpulseMax = max($newpulseMax, $RoomsPulses{$d});
}
# synchronize the heating on the "off" edge of the pulse
# try to minimize the situation where all rooms are "on" at the same time
#
@ -453,6 +520,10 @@ PWM_Calculate($)
PWMR_SetRoom ($defs{$roomOff}, "off");
if (defined($defs{$roomOff}->{helper}{maxOffTimeLastSwitch})) {
delete ($defs{$roomOff}->{helper}{maxOffTimeLastSwitch});
}
$cntRoomsOff++;
$pulseRoomsOff += $RoomsPulses{$roomOff};
}
@ -463,11 +534,37 @@ PWM_Calculate($)
$roomsWaitOffset{$wkey} = 0;
PWMR_SetRoom ($defs{$roomOn}, "on");
if (defined($RoomsMaxOffTimeProtect{$roomOn})) {
$defs{$roomOn}->{helper}{maxOffTimeLastSwitch} = time();
}
$cntRoomsOn++;
$pulseRoomsOn += $RoomsPulses{$roomOn};
}
if (0) {
foreach my $roomMOP (sort keys %RoomsMaxOffTimeProtect) {
my $wkey = $name."-".$roomMOP;
$roomsWaitOffset{$wkey} = 0;
if ( $RoomsMaxOffTimeProtect{$roomMOP} eq "on") {
PWMR_SetRoom ($defs{$roomMOP}, "on");
$cntRoomsOn++;
$pulseRoomsOn += $RoomsPulses{$roomMOP};
} else {
PWMR_SetRoom ($defs{$roomMOP}, "off");
$cntRoomsOff++;
$pulseRoomsOff += $RoomsPulses{$roomMOP};
}
}
}
foreach my $roomVP (sort keys %RoomsValveProtect) {
my $wkey = $name."-".$roomVP;
@ -670,6 +767,7 @@ PWM_Calculate($)
readingsEndUpdate($hash, 1);
Log3 ($hash, 3, "PWM_Calculate $name done");
# if(!$hash->{LOCAL}) {
# DoTrigger($name, undef) if($init_done);
@ -688,7 +786,7 @@ PWM_CalcRoom(@)
my $cycletime = $hash->{CYCLETIME};
my ($temperaturV, $actorV, $factor, $oldpulse, $newpulse, $prevswitchtime, $windowV) =
my ($temperaturV, $actorV, $factor, $oldpulse, $newpulse, $prevswitchtime, $windowV, $maxOffTimeApply, $maxOffTime, $maxOffTimePeriod, $maxOffTimeAct) =
PWMR_ReadRoom($room, $cycletime, $hash->{MaxPulse});
my $nextswitchtime;
@ -702,6 +800,21 @@ PWM_CalcRoom(@)
if ($actorV eq "on") # current state is "on"
{
# ----------------
# check if maxOffTime is active and maxOffTimePeriod is over
if (defined ($room->{helper}{maxOffTimeLastSwitch})) {
if ( $room->{helper}{maxOffTimeLastSwitch} + ($maxOffTimePeriod * 60) > time()) {
Log3 ($hash, 3, "PWM_CalcRoom $room->{NAME}: F15 maxOffTime continue");
return ("on_mop_stay", $newpulse, $cycletime, $actorV);
} else {
Log3 ($hash, 3, "PWM_CalcRoom $room->{NAME}: F16 maxOffTime off");
#delete ($room->{helper}{maxOffTimeLastSwitch});
return ("off_mop", $newpulse, $cycletime, $actorV);
}
}
# ----------------
# check if valve protection is active, keep this state for 5 minutes
@ -761,6 +874,7 @@ PWM_CalcRoom(@)
}
elsif ($actorV eq "off") # current state is "off"
{
# ----------------
# check if valve protection is activated (attribute valveProtectIdlePeriod is set)
@ -768,9 +882,9 @@ PWM_CalcRoom(@)
# period is defined in days (*86400)
if ($room->{READINGS}{lastswitch}{VAL} + ($attr{$name}{"valveProtectIdlePeriod"} * 86400) < time()) {
$room->{helper}{valveProtectLastSwitch} = time();
Log3 ($hash, 3, "PWM_CalcRoom $room->{NAME}: F12 valve protect");
return ("on_vp", $newpulse, $cycletime, $actorV);
$room->{helper}{valveProtectLastSwitch} = time();
Log3 ($hash, 3, "PWM_CalcRoom $room->{NAME}: F12 valve protect");
return ("on_vp", $newpulse, $cycletime, $actorV);
}
}
@ -778,12 +892,34 @@ PWM_CalcRoom(@)
# decide if to change to "on"
if ($oldpulse == 0 && $newpulse > 0) { # was 0% now heating is required
Log3 ($hash, 3, "PWM_CalcRoom $room->{NAME}: F7 new on");
return ("on", $newpulse, $cycletime, $actorV);
Log3 ($hash, 3, "PWM_CalcRoom $room->{NAME}: F7 new on");
return ("on", $newpulse, $cycletime, $actorV);
}
if ($newpulse == 0) {
Log3 ($hash, 3, "PWM_CalcRoom $room->{NAME}: F11 stay off (0)");
return ("", $newpulse, $cycletime, $actorV);
# ----------------
# check if maxOffTime protection is activated (attribute maxOffTimeIdlePeriod is set)
if ($maxOffTimeApply > 0) {
## wz > 2:00
if ($maxOffTimeAct >= $maxOffTime) {
Log3 ($hash, 3, "PWM_CalcRoom $room->{NAME}: F17 maxOffTime protection");
return ("on_mop", $newpulse, $cycletime, $actorV);
}
## wz > 2:00 / 2
if ($maxOffTimeAct >= $maxOffTime / 2) {
Log3 ($hash, 3, "PWM_CalcRoom $room->{NAME}: F18 maxOffTime protection (possible)");
return ("on_mop_maybe", $newpulse, $cycletime, $actorV);
}
}
Log3 ($hash, 3, "PWM_CalcRoom $room->{NAME}: F11 stay off (0)");
return ("", $newpulse, $cycletime, $actorV);
}
if ($newpulse > $oldpulse) { # was 30% now it is 80%
@ -813,6 +949,7 @@ PWM_CalcRoom(@)
}
}
else # $actorV not "on" of "off"
@ -906,7 +1043,7 @@ PWM_Set($@)
{
my ($hash, @a) = @_;
my $u = "Unknown argument $a[1], choose one of recalc interval cycletime";
my $u = "Unknown argument $a[1], choose one of recalc interval cycletime maxOffTimeCalculation:on,off";
if ( $a[1] =~ /^interval$|^cycletime$/ ) {
@ -922,6 +1059,10 @@ PWM_Set($@)
my $v = PWM_Calculate($hash);
#delete $hash->{LOCAL};
} elsif ( $a[1] =~ /^maxOffTimeCalculation$/ ) {
readingsSingleUpdate ($hash, "maxOffTimeCalculation", $a[2], 1);
} else {
return $u;
@ -1265,6 +1406,10 @@ PWM_Attr(@)
Cause recalculation that normally appeary every <i>interval</i> seconds.
</li><br>
<li>maxOffTimeCalculation<br>
Defines if parameter maxOffTime for rooms (PWMR objects) is evaluated or not. Possible Values are "on" or "off". Sets reading maxOffTimeCalculation.<br>
</li>
</ul>
<b>Get</b>