76_SMAInverter.pm:fix STP X Bug

git-svn-id: https://svn.fhem.de/fhem/trunk@29472 2b470e98-0d58-463d-a4d8-8e2adae1ed80
This commit is contained in:
MadMax 2025-01-02 13:24:13 +00:00
parent d0e1a736a6
commit 44816a370c

View File

@ -33,6 +33,9 @@ eval "use FHEM::Meta;1" or my $modMetaAbsent = 1;
# Versions History by DS_Starter
our %SMAInverter_vNotesIntern = (
"2.29.2" => "31.12.2024 fix Bug STP X, fix STP TypeName",
"2.29.1" => "14.12.2024 bat_pwr whith detail-level 0, fix detail-level 0 bug",
"2.29.0" => "09.12.2024 get Data detail-level",
"2.28.3" => "01.12.2024 code optimized, remove given",
"2.28.2" => "16.11.2024 code optimized, remove switch",
"2.28.1" => "15.11.2024 code optimized",
@ -332,9 +335,10 @@ my %SMAInverter_devtypes = (
19049 => "STP6.0SE (SUNNY TRIPOWER 6.0 SE)",
19050 => "STP8.0SE (SUNNY TRIPOWER 8.0 SE)",
19051 => "STP10.0SE (SUNNY TRIPOWER 10.0 SE)",
9490 => "STP X 50-12 (SUNNY TRIPOWER X 50-12)",
9492 => "STP X 50-12 (SUNNY TRIPOWER X 50-12)",
9491 => "STP X 50-15 (SUNNY TRIPOWER X 50-15)",
9492 => "STP X 50-20 (SUNNY TRIPOWER X 50-20)",
9490 => "STP X 50-17 (SUNNY TRIPOWER X 50-17)",
9489 => "STP X 50-20 (SUNNY TRIPOWER X 50-20)",
9488 => "STP X 50-25 (SUNNY TRIPOWER X 50-25)",
);
@ -475,14 +479,16 @@ sub SMAInverter_Get($$) {
return "\"get X\" needs at least an argument" if ( @a < 2 );
my $name = shift @a;
my $opt = shift @a;
my $vel_1 = shift @a;
my $timeout = AttrVal($name, "timeout", 60);
my $getlist = "Unknown argument $opt, choose one of ".
"data:noArg ";
"data:-,0,1,2 ";
return "module is disabled" if(IsDisabled($name));
if ($opt eq "data") {
$hash->{detailLevel} = $vel_1;
SMAInverter_GetData($hash);
} else {
return "$getlist";
@ -914,7 +920,12 @@ sub SMAInverter_getstatusDoParse($) {
$ist = [gettimeofday];
# Get the current attributes
my $detail_level = AttrVal($name, "detail-level", 0);
my $detail_level = InternalVal($name, "detailLevel", "");
$detail_level = AttrVal($name, "detail-level", 0) if ($detail_level eq "" || $detail_level eq "-");
$hash->{detailLevel} = "";
Log3 $name, 4, "$name - detail-level: ".$detail_level;
my $readEnergyMeter_data = AttrVal($name, "readEnergyMeter-data", 0);
# Aufbau Command-Array
@ -932,6 +943,21 @@ sub SMAInverter_getstatusDoParse($) {
push(@commands, "sup_SpotBatteryUnload"); # Check BatteryUnload
}
if ($INVTYPE_NAME =~ /SBS(6\.0|5\.0|3\.7)/xs)
{
push(@commands, "sup_BatteryInfo_UDC"); # Check BatteryInfo Voltage
push(@commands, "sup_BatteryInfo_IDC"); # Check BatteryInfo current
}
elsif ($INVTYPE_NAME =~ /SBS(1\.5|2\.0|2\.5)/xs || $INVCLASS eq "8009")
{
push(@commands, "sup_BatteryInfo_2"); # Check BatteryInfo Voltage
push(@commands, "sup_BatteryInfo_Charge");
}
elsif($INVCLASS eq "8009" || $INVCLASS eq "8007")
{
push(@commands, "sup_BatteryInfo"); # Check BatteryInfo
}
push(@commands, "sup_PVEnergyProduction") if($INVCLASS eq "8009"); # Check PV-EnergyProduction (Hybrid Inverter)
push(@commands, "sup_SpotDCPower_3") if($INVCLASS eq "8009" || $INVCLASS eq "8001"); # SpotDCPower summary
@ -948,21 +974,6 @@ sub SMAInverter_getstatusDoParse($) {
{
push(@commands, "sup_SpotACCurrentBackup"); # Check BatteryInfo
}
if ($INVTYPE_NAME =~ /SBS(6\.0|5\.0|3\.7)/xs)
{
push(@commands, "sup_BatteryInfo_UDC"); # Check BatteryInfo Voltage
push(@commands, "sup_BatteryInfo_IDC"); # Check BatteryInfo current
}
elsif ($INVTYPE_NAME =~ /SBS(1\.5|2\.0|2\.5)/xs || $INVCLASS eq "8009")
{
push(@commands, "sup_BatteryInfo_2"); # Check BatteryInfo Voltage
push(@commands, "sup_BatteryInfo_Charge");
}
elsif($INVCLASS eq "8009" || $INVCLASS eq "8007")
{
push(@commands, "sup_BatteryInfo"); # Check BatteryInfo
}
}
if($detail_level > 1) {
@ -992,7 +1003,7 @@ sub SMAInverter_getstatusDoParse($) {
#push(@commands, "sup_BatteryInfo_5");
}
push(@commands, "sup_lower_discharge_limit"); #if($readParameter == 1 && $INVCLASS eq "8009");
push(@commands, "sup_lower_discharge_limit") if($readParameter == 1 && $INVCLASS eq "8009");
push(@commands, "sup_Insulation") if($installer == 1); # Isolationsüberwachung
@ -1276,7 +1287,10 @@ sub SMAInverter_getstatusDoParse($) {
use warnings;
}
# SBFSpot Kompatibilitätsmodus
if($sup_TypeLabel) {
push(@row_array, ($sc?"device_type ":"INV_TYPE ").SMAInverter_devtype($inv_TYPE)."\n");
push(@row_array, ($sc?"device_class ":"INV_CLASS ").SMAInverter_classtype($inv_CLASS)."\n");
}
if($sup_EM_1) {
push(@row_array, ($sc?"Meter_TOTAL_FeedIn ".($Meter_Total_Yield/1000):"Meter_TOTAL_FeedIn ".($Meter_Total_Yield))."\n") if ($Meter_Total_Yield ne "-");
@ -1352,6 +1366,18 @@ sub SMAInverter_getstatusDoParse($) {
push(@row_array, ($sc?"bat_unloadtotal ".($inv_BAT_UNLOADTOTAL/1000):"BAT_UNLOADTOTAL ".$inv_BAT_UNLOADTOTAL)."\n") if ($inv_BAT_UNLOADTOTAL ne "-");
push(@row_array, ($sc?"bat_unloadtoday ".($inv_BAT_UNLOADTODAY/1000):"BAT_UNLOADTODAY ".$inv_BAT_UNLOADTODAY)."\n") if ($inv_BAT_UNLOADTODAY ne "-");
}
if($sup_BatteryInfo || $sup_BatteryInfo_2) {
if($INVTYPE_NAME =~ /STP(5\.0|6\.0|8\.0|10\.0)SE/xs)
{
push(@row_array, ($sc?"bat_pdc ".(sprintf("%.0f",($inv_BAT_UDC * $inv_BAT_IDC))/1000):"BAT_PDC ".sprintf("%.0f",($inv_BAT_UDC * $inv_BAT_IDC)))."\n") if ($inv_BAT_UNLOADTOTAL ne "-");
}
}
if($sup_BatteryInfo_Charge) {
push(@row_array, ($sc?"bat_p_charge ".($inv_BAT_P_Charge/1000):"BAT_P_CHARGE ".($inv_BAT_P_Charge))."\n"); #TTT
push(@row_array, ($sc?"bat_p_discharge ".($inv_BAT_P_Discharge/1000):"BAT_P_DISCHARGE ".($inv_BAT_P_Discharge))."\n"); #TTT
}
if($detail_level > 0) {
# For Detail Level 1
@ -1382,17 +1408,13 @@ sub SMAInverter_getstatusDoParse($) {
push(@row_array, ($sc?"phase_backup_2_iac ":"SPOT_Backup_IAC2 ").sprintf("%.2f",$inv_SPOT_IAC2_Backup)."\n") if ($inv_SPOT_IAC2_Backup ne "-");
push(@row_array, ($sc?"phase_backup_3_iac ":"SPOT_Backup_IAC3 ").sprintf("%.2f",$inv_SPOT_IAC3_Backup)."\n") if ($inv_SPOT_IAC3_Backup ne "-");
push(@row_array, ($sc?"phase_backup_1_pac ":"SPOT_Backup_PAC1 ").sprintf("%.0f",$inv_SPOT_IAC1_Backup * $inv_SPOT_UAC1)."\n") if ($inv_SPOT_IAC1_Backup ne "-");
push(@row_array, ($sc?"phase_backup_2_pac ":"SPOT_Backup_PAC2 ").sprintf("%.0f",$inv_SPOT_IAC2_Backup * $inv_SPOT_UAC2)."\n") if ($inv_SPOT_IAC2_Backup ne "-");
push(@row_array, ($sc?"phase_backup_3_pac ":"SPOT_Backup_PAC3 ").sprintf("%.0f",$inv_SPOT_IAC3_Backup * $inv_SPOT_UAC3)."\n") if ($inv_SPOT_IAC3_Backup ne "-");
push(@row_array, ($sc?"phase_backup_1_pac ".sprintf("%.3f",$inv_SPOT_IAC1_Backup * $inv_SPOT_UAC1 /1000):"SPOT_Backup_PAC1 ".sprintf("%.0f",$inv_SPOT_IAC1_Backup * $inv_SPOT_UAC1))."\n") if ($inv_SPOT_IAC1_Backup ne "-");
push(@row_array, ($sc?"phase_backup_2_pac ".sprintf("%.3f",$inv_SPOT_IAC2_Backup * $inv_SPOT_UAC2 /1000):"SPOT_Backup_PAC2 ".sprintf("%.0f",$inv_SPOT_IAC2_Backup * $inv_SPOT_UAC2))."\n") if ($inv_SPOT_IAC2_Backup ne "-");
push(@row_array, ($sc?"phase_backup_3_pac ".sprintf("%.3f",$inv_SPOT_IAC3_Backup * $inv_SPOT_UAC3 /1000):"SPOT_Backup_PAC3 ".sprintf("%.0f",$inv_SPOT_IAC3_Backup * $inv_SPOT_UAC3))."\n") if ($inv_SPOT_IAC3_Backup ne "-");
}
if($sup_BatteryInfo || $sup_BatteryInfo_2) {
push(@row_array, ($sc?"bat_udc ":"BAT_UDC ").$inv_BAT_UDC."\n");
push(@row_array, ($sc?"bat_idc ":"BAT_IDC ").$inv_BAT_IDC."\n");
if($INVTYPE_NAME =~ /STP(5\.0|6\.0|8\.0|10\.0)SE/xs)
{
push(@row_array, ($sc?"bat_pdc ":"BAT_PDC ").sprintf("%.0f",($inv_BAT_UDC * $inv_BAT_IDC))."\n");
}
}
if($sup_BatteryInfo_UDC) {
push(@row_array, ($sc?"bat_udc ":"BAT_UDC ").$inv_BAT_UDC."\n");
@ -1409,10 +1431,6 @@ sub SMAInverter_getstatusDoParse($) {
if($sup_BatteryInfo_Capacity) {
push(@row_array, ($sc?"bat_capacity ":"BAT_CAPACITY ").$inv_BAT_CAPACITY."\n"); #TTT
}
if($sup_BatteryInfo_Charge) {
push(@row_array, ($sc?"bat_p_charge ":"BAT_P_CHARGE ").($inv_BAT_P_Charge/1000)."\n"); #TTT
push(@row_array, ($sc?"bat_p_discharge ":"BAT_P_DISCHARGE ").($inv_BAT_P_Discharge/1000)."\n"); #TTT
}
}
if($detail_level > 1) {
@ -1444,8 +1462,6 @@ sub SMAInverter_getstatusDoParse($) {
push(@row_array, ($sc?"grid_freq ":"SPOT_FREQ ").sprintf("%.2f",$inv_SPOT_FREQ)."\n");
}
if($sup_TypeLabel) {
push(@row_array, ($sc?"device_type ":"INV_TYPE ").SMAInverter_devtype($inv_TYPE)."\n");
push(@row_array, ($sc?"device_class ":"INV_CLASS ").SMAInverter_classtype($inv_CLASS)."\n");
push(@row_array, ($sc?"susyid ":"SUSyID ").$inv_susyid." - SN: ".$inv_serial."\n") if($inv_susyid && $inv_serial);
push(@row_array, ($sc?"device_name ":"INV_NAME ")."SN: ".$inv_serial."\n") if($inv_serial);
push(@row_array, ($sc?"serial_number ":"Serialnumber ").$inv_serial."\n") if($inv_serial);
@ -3430,7 +3446,7 @@ Die Abfrage des Wechselrichters wird non-blocking ausgeführt. Der Timeoutwert f
"PV",
"inverter"
],
"version": "v2.28.3",
"version": "v2.29.2",
"release_status": "stable",
"author": [
"Maximilian Paries",